1' - 0" <br />EQ. <br />EQ. <br />EQ. <br />TYP. <br />1' - 0" <br />EQ. <br />ATTACHMENT OF LIGHT FIXTURES AND AIR TERMINALS TO CEILING GRID <br />(SEE NOTE NO. 23 ABOVE) <br />2 EACH SIDE <br />4 EACH SIDE <br />#8 SELF-TAPPING <br />SHEET METAL <br />SCREWS <br />24" LONG FIXTURE <br />OR AIR TERMINAL <br />48" LONG FIXTURE <br />OR AIR TERMINAL <br />FIXED END <br />FREE END <br />FR <br />E <br />E <br /> <br />E <br />N <br />D <br /> <br />FI <br />X <br />E <br />D <br /> <br />E <br />N <br />D <br /> <br />12 GA. HANGER WIRE <br />8" OR 1/4 LENGTH OF <br />END TEE FROM WALL. <br />SEE NOTE 3 OF THE <br />CEILING GENERAL <br />NOTES. <br />CEILING GRID MEMBER <br />ATTACHED TO TWO <br />ADJACENT WALLS <br />ONLY. SEE NOTE 5 OF <br />THE CEILING GENERAL <br />NOTES AND DETAIL <br />8 / A0.4.4 <br />CEILING GRID MEMBER ATTACHED TO <br />TWO ADJACENT WALLS ONLY. SEE NOTE 5 <br />OF THE CEILING GENERAL NOTES AND <br />DETAIL 8 / A0.4.4 <br />12 GA. HANGER WIRES <br />@48" 0.C. MAXIMUM - <br />SEE NOTES 1, 2, & 3 <br />OF THE CEILING <br />GENERAL NOTES <br />CROSS RUNNERS @ <br />24" O.C. MAXIMUM <br />MAIN RUNNER @ <br />48" O.C. <br />MAXIMUM <br />LIGHT FIXTURES & HVAC <br />GRILLES - SEE NOTE <br />19, 20, & 21 OF THE <br />CEILING GENERAL <br />NOTES. <br />SEE NOTES 10A & 10B OF <br />THE CEILING GENERAL <br />NOTES DETAIL 1 / A0.4.4 <br />AND FOR SPACING OF <br />BRACING ASSEMBLIES <br />SEE NOTES 10A & 10B <br />OF THE CEILING <br />GENERAL NOTES <br />DETAIL 1 / A0.4.4 <br />AND FOR SPACING OF <br />BRACING ASSEMBLIES <br />SEE NOTES 10A & 10B OF THE CEILING <br />GENERAL NOTES DETAIL 1 /A0.4.4 <br />AND FOR SPACING OF BRACING <br />ASSEMBLIES <br />TYP. 12 GA SPLAYED BRACING WIRES & <br />COMPRESSION POST. <br />SEE NOTES 9 & 10 OF THE CEILING GENERAL <br />NOTES AND DETAIL 1 / A0.4.4 <br />CEILING GRID MEMBERS NOT <br />ATTACHED TO ADJACENT WALLS. SEE <br />NOTE 7 OF THE CEILING GENERAL <br />NOTES AND DETAIL 8 / A0.4.4 <br />SAME CRITERIA AS <br />NOTED ABOVE ARE <br />APPLICABLE AT 24" X <br />24" GRID. <br />12 GA SPLAYED <br />BRACING WIRES & <br />COMPRESSION POST. <br />SEE NOTES 9 & 10 OF <br />THE CEILING GENERAL <br />NOTES AND DETAIL <br />1 / A0.4.4 <br />TYP. 12 GA. HANGER <br />WIRE 8" OR 1/4 <br />LENGTH OF END TEE <br />FROM WALL. <br />SEE NOTE 3 OF THE <br />CEILING GENERAL <br />NOTES. <br />12 GA. HANGER <br />WIRES @48" 0.C. <br />MAXIMUM - <br />SEE NOTES 1, 2, & 3 <br />OF THE CEILING <br />GENERAL NOTES <br />TYP. HANGER WIRE AND <br />BRACING WIRE <br />ATTACHMENT TO <br />STRUCTURE. SEE NOTE 16 <br />OF THE CEILING GENERAL <br />NOTES <br />SEE NOTES 10A & 10B <br />OF THE CEILING <br />GENERAL NOTES DETAIL <br />1 / A0.4.4 <br />AND FOR SPACING OF <br />BRACING ASSEMBLIES <br />PLAN <br />SECTION <br />1 1/2" <br />1/2" MIN <br />1 1/2" <br />MAXIMUM LENGTH: SEE CHART <br />1 1/4" <br />1 1/4" <br />6" MINIMUM <br />6" MINIMUM <br />3/4" MIN. <br />#12 X 1" SELF-TAPPING SCREWS INTO STEEL DECK, <br />OR TWO 3/8" DIA. EXPANSION ANCHORS 2" <br />MINIMUM <br />EMBED INTO CONCRETE, SEE DETAILS <br />1/8" X 2" WIDE X 3" X 3" BENT STEEL PLATE <br />TWO 1/4" DIA. MACHINE BOLTS WITH FLAT WASHER <br />AT NUTS, AND TWO NUTS EACH. DO NOT CRUSH <br />EMT. <br />ELECTRICAL CONDUIT (EMT) <br />COMPRESSION POST - SEE CHART BELOW FOR SIZE <br />TWO #12 SHEET METAL SCREWS THROUGH <br />BOTH SIDES OF SLEEVE & POST <br />ELECTRICAL CONDUIT (EMT) SLEEVE ONE SIZE <br />LARGE THAN COMPRESSION POST <br />ONE 1/4" DIA. MACHINE BOLT WITH FLAT WASHER <br />AT HEAD AND AT NUTS, AND TWO NUTS, <br />THROUGHBOTH SIDES OF SLEEVE AND THROUGH <br />MAIN RUNNER. DO NOT CRUSH MAIN RUNNER. <br />MAIN RUNNER (TYP.) <br />ELECTRICAL CONDUIT (EMT) POST <br />METAL STUD POST <br />MIN <br />1 1/4" <br />MAXIMUM LENGTH: SEE CHART <br />(TYP.) <br />6" MINIMUM <br />2 #10 SHEET METAL SCREWS EACH SIDE OF <br />TRACK (TYP.) <br />BOTTOM OF STRUCTURE <br />1 5/8" X 20 GAUGE METAL STUD TRACK <br />SPANNING 2 FLUTES W/ FOUR #8 X 1/2" <br />SELF-TAPPING SCREWS INTO STEEL DECK, <br />OR TWO 3/8" DIA. EXPANSION ANCHORS <br />[ICC-ER 1917], 2" MINIMUM EMBED INTO <br />CONCRETE, SEE DETAILS <br />1-5/8" X 20 GAUGE METAL STUD COMPRESSION <br />POST <br />ATTACH STUD TO MAIN RUNNER W/ ONE 1/4" <br />DIA. MACHINE BOLT WITH FLAT WASHER AT HEAD <br />AND TWO NUTS, THROUGH STUD AND MAIN <br />RUNNER. DO NOT CRUSH MAIN RUNNER. <br />COMPRESSION POST CHART <br />COMPRESSION POST MINIMUM <br />CROSS <br />SECTIONAL <br />AREA "A" <br />MINIMUM <br />RADIUS OF <br />GYRATION <br />"R" OR "Ry" <br />CEILING TO <br />STRUCTURE <br />MAXIMUM LENGTH <br />OF COMPRESSION <br />POST <br />1/2" DIA. EMT <br />3/4" DIA. EMT <br />1" DIA. EMT <br />1 5/8" X 20 GAUGE <br />METAL STUD <br />(2) 2 1/2" X 20 <br />GAUGE METAL <br />"T" STUDS <br />0.088 IN.2 <br />0.134 IN.2 <br />0.198 IN.2 <br />0.155 IN.2 <br />0.348 IN.2 <br />0.238 IN. <br />0.309 IN. <br />0.392 IN. <br />0.454 IN. <br />0.71 IN. <br />3'-10" <br />5'-0" <br />6'-6" <br />7'-6" <br />15'-0" <br />NOTE: USE EMT OR METAL STUD COMPRESSION POST WITH ACCEPTABLE CEILING TO STRUCTURE <br />LENGTH LISTED IN CHART. <br />OR 8" MAX (TYP) <br /> LESSER OF 1/4 <br />LENGTH OF RUNNER, <br />LINE OF WALL (TYP). <br />MFR'S. APPROVED PERIMETER CLIP @ <br />EACH RUNNER <br />FIRST RUNNER PARALLEL TO WALL (TYP.) <br />WALL MOLDING W/ SHEET METAL SCREW INTO EACH STL STUD OR <br />1/4" EXPANSION ANCHOR, 1 1/4" MINIMUM EMBED, @ 24" O.C. <br />MAX. AT CONC.WALL (TYP.) <br />ATTACHED TO WALL <br />(AT TWO ADJACENT WALLS ONLY - SEE <br />NOTE 4 OF THE CEILING GENERAL NOTES) <br />2" <br />MIN. <br />3/4" CLR. <br />8" MAX (TYP) <br />LESSER OF 1/4 LENGTH <br />OR RUNNER, OR <br />NOT ATTACHED TO WALL <br />(AT OPPOSITE WALLS) <br />HANGER WIRE - SEE NOTE 1 OF THE <br />CEILING GENERAL NOTES (TYP.) <br />A.) 3/4" COLD ROLLED STEEL STABILIZER <br />CHANNEL <br />OR <br />B.) SLOTTED ANGLE INTERLOCKING STRUT - <br />SEE NOTE 6 OF THE CEILING GENERAL NOTES <br />A. <br />B. <br />(OMIT IF FIRST RUNNER PARALLEL TO WALL IS <br />WITHIN 12" OF WALL) [REF. DSA IR25-2.10, FIG <br />2.] <br />(TYP) <br />45.00° MAX <br />(TYP) <br />45.00° MAX. <br />12 GA. VERTICAL HANGER WIRES <br />AT 4' - 0" ON CENTER EACH WAY. <br />SEE NOTES 1,2, & 3 OF THE <br />CEILING GENERAL NOTES <br />FOUR 12 GA, SPLAYED <br />BRACING WIRES, TWO <br />PARALLEL TO AND TWO <br />PERPENDICULAR TO MAIN <br />RUNNERS. (4 TURNS MIN IN <br />1-1/2" @ BOTH ENDS) SEE <br />NOTES 9 & 10 OF THE <br />CEILING GENERAL NOTES <br />FOR ATTACHMENT TO STRUCTURE <br />ABOVE SEE DETAILS: <br />7 / A0.4.4 <br />5 / A0.4.4 <br />6 / A0.4.4 <br />MAIN RUNNERS <br />CROSS RUNNERS <br />2" MAXIMUM FROM BRACING WIRES <br />TO COMPRESSION STRUT (TYPICAL) <br />(COMPRESSION POST SHALL <br />NOT REPLACE HANGER WIRE) <br />VERTICAL COMPRESSION POST <br />AT EACH SET OF BRACING <br />WIRES - <br />SEE DETAIL 3 / A0.4.4 <br />NOTE: <br />WHEN MULTIPLE SADDLY <br />TIES ARE REQ'D, THEY <br />SHALL <br />ALTERNATE BACK AND <br />FORTH, SEE NOTE 7 OF <br />THE CEILING GENERAL <br />NOTES. <br />TRAPEZE <br />SADDLE TIE W/ <br />DOUBLE LOOP SUPPORT <br />HANGER WIRES W/ MIN. <br />3 TIGHT TURNS, SEE OF THE <br />CEILING GENERAL NOTES <br />SADDLE TIE <br />REQ'D FOR ALL <br />WIDTHS <br />GREATER THAN <br />1/4" <br />HANGER WIRE <br />BRACING WIRE <br />MAX <br />5/8" <br />STRUCTURAL STEEL <br />12 GA. X 3/4" WIDE (MINIMUM) STEEL STRAP W/ <br />POWDER <br />ACTUATED FASTENER (3/4" MIN PENETRATION) <br />HILTI X-AL-H, 0.177 , 1 1/2" MIN. EMBED [ICC <br />ESR-1663], TYP. <br />HANGER WIRE WITH MINIMUM 3 TIGHT TURNS IN <br />1 1/2" - SEE NOTES 1 & 16 OF THE CEILING <br />GENERAL NOTES <br />MAX <br />45.00° <br />MAX <br />5/8" <br />STRUCTURAL STEEL <br />12 GA. X 1" WIDE X 2" LONG (MINIMUM) STEEL <br />STRAP W/ POWDER ACTUATED FASTENER (3/4" <br />MIN PENETRATION) <br />BRACING WIRE WITH MINIMUM 4 TIGHT TURNS <br />IN 1 1/2" - SEE NOTES 10 & 16 OF THE CEILING <br />GENERAL NOTES <br />WIRE ATTACHMENT WITH EXPANSION ANCHOR <br />1" MIN. <br />EQ EQ MINIMUM 20 GA. STEEL DECK (WITH <br />CONCRETE FILL) <br />HILTI HLC-T 1/4" X 1-3/8" EXPANSION ANCHOR <br />WITH TIE-WIRE HEAD (OR APPROVED EQUAL) <br />BRACING WIRE WITH MINIMUM 4 TIGHT TURNS IN 1 <br />1/2" - SEE NOTES 10 & 16 OF THE CEILING <br />GENERAL NOTES <br />HANGER WIRE <br />BRACING WIRE <br />#3 X 12" LONG REBAR <br />MINIMUM 20 GA. STEEL DECK <br />(WITH NO CONCRETE FILL) <br />HANGER WIRE TIED TO #3 REBAR WITH <br />THREE WRAPS AROUND REBAR AND ONE <br />WRAP AROUND WIRE -SEE NOTES 1 & 16 OF <br />THE CEILING GENERAL NOTES. <br />MAX <br />45.00° <br />MINIMUM 20 GA. STEEL DECK ( WITH NO <br />CONCRETE FILL) <br />MINIMUM 12 GA. X 3" WIDE X 4" LONG STEEL <br />STRAP W/ TWO #8 X 1/2" SELF TAPPING SCREWS <br />BRACING WIRE WITH MINIMUM 4 TIGHT TURNS <br />IN 1 1/2" - SEE NOTES 10 & 16 OF THE CEILING <br />GENERAL NOTES <br />ARMSTRONG CROSS TEE <br />6 <br />1 <br />6 <br />1 <br />#12 HANGER WIRE ANCHORED <br />TO STRUCTURE ABOVE OR TO <br />THE WALL ABOVE THE CEILING <br />ARMSTRONG STABILIZER BAR, OR <br />OTHER SUITABLE SYSTEM, TO <br />KEEP PERIMETER COMPONENTS <br />FROM SPREADING APART <br />3/8" <br />7" MAX. <br />. <br />IF-01. <br />PROJECT <br />COPYRIGHT LOC, INC <br />ORIGINAL SHEET SIZE: 42" X 30" <br />LOC <br />CLIENT: <br />ARCHITECT: <br />CONSULTANTS: <br />PREPARED UNDER THE SUPERVISION OF: <br />ALI JEEVANJEE <br />LOC ARCHITECTS DATE <br />REVIEWED FOR CONSTRUCTABILITY: <br />SEAN THOMAS <br />PRINCIPAL CIVIL ENGINEER <br />RCE NO.: 80470 <br />DATE <br />RECOMMENDED FOR CONSTRUCTION: <br />JASON GABRIEL <br />PRINCIPAL CIVIL ENGINEER <br />RCE NO.: 62968 <br />DATE <br />3/28/2025 6:04:37 PM <br />2308 <br />TYP CEILING <br />DETAILS <br />MARCH 28, 2025 <br />PLAN CHECK <br />SUBMITTAL 02 <br />G0.6 <br />SANTA ANA ZOO <br />1821 & 1823 E CHESTNUT AVE, SANTA <br />ANA, CA 92701 <br />KPFF <br />STRUCTURAL ENGINEER <br />LOC ARCHITECTS <br />KPFF <br />CIVIL ENGINEER <br />BORDER <br />LANDSCAPE ARCHITECT <br />ABRARI AND ASSOCIATES <br />MEP ENGINEER <br />ASSOCIATED SOILS ENGINEERING <br />GEOTECHNICAL ENGINEER <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Ramzi.hodali@kpff.com <br />700 S. FLOWER, SUITE 2100 <br />LOS ANGELES, CA 90017 <br />213 372 5111 <br />Sharad.Ganju@kpff.com <br />724 S. SPRING ST, SUITE 701 <br />LOS ANGELES, CA 90014 <br />213 372 5111 <br />Darren@border-la.com <br />1713 S. STANDARD AVE <br />GLENDALE, CA 91201 <br />818 956 1900 <br />Telma@abrari.com <br />2860 WALNUT AVE. <br />SIGNAL HILL, CA 90755 <br />562 897 2749 <br />Ted@associatedsoils.com <br />3203 E. 4TH ST <br />LOS ANGELES, CA 90063 <br />213 537 0480 <br />Office@loc-arch.com <br />1801 E. CHESTNUT AVE. <br />SANTA ANA, CA 92701 <br />714 647 6575 <br />Efisher@santa-ana.org <br />SANTA ANA ZOO <br />EDUCATION HUB <br />MARCH 28, 2025 <br />SUSPENDED LAY-IN PANEL ACOUSTIC <br />CEILING GENERAL NOTES <br />THE DESIGN AND INSTALLATION OF SUSPENDED ACOUSTIC CEILING SYSTEMS SHALL COMPLY WITH THE REQUIREMENTS CONTAINED IN TITLE 24, PART 2 - CALIFORNIA BUILDING CODE 2022 (CBC <br />CHAP 25 AND ASTM C635 AND 636), AND WITH THE FOLLOWING ADDITIONAL REQUIREMENTS AS NOTED: <br />2019 CITY OF LOS ANGELES BUILDING CODE (CHAPTER 8 AND ASTM C635 AND 636) FOR SUSPENDED CEILING SYSTEMS. <br />THE FOLLOWING REQUIREMENTS APPLY TO CEILING SYSTEMS WHOSE TOTAL WEIGHT, INCLUDING CEILING MOUNTED AIR TERMINALS, SERVICES AND LIGHT FIXTURES, DOES NOT EXCEED FOUR (4) <br />PSF. HEAVIER SYSTEMS, AND THOSE SUPPORTING LATERAL LOADS FROM PARTITIONS, WILL REQUIRE SPECIAL DESIGN DETAILS. SEE SPECIFICATIONS SECTION 09510 FOR ADDITIONAL INFORMATION <br />REGARDING THE SUSPENDED ACOUSTICAL CEILING SYSTEM. <br />1. THE CEILING GRID SYSTEM MUST BE RATED HEAVY DUTY AS DEFINED BY ASTM C635. <br />2. #12 GAGE WIRE SHALL BE 0.106 INCHES IN DIAMETER CONFORMING TO ASTM A641. #12 GAGE WIRE SHALL BE SOFT ANNEALED, GALVANIZED STEEL WIRE WITH A CLASS 1 COATING. <br />3. MAIN RUNNERS, CROSS RUNNERS, SPLICES, EXPANSION DEVICES, INTERSECTION CONNECTORS SHALL BE DESIGNED TO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 180 LBS. <br />IN COMPRESSION AND TENSION PER ASTM E58 - SECTION 5.1.2. <br />4. #12 GAGE HANGER WIRES MAY BE USED FOR UP TO AND INCLUDING 4 FT. BY. 4 FT. GRID SPACING AND SHALL BE ATTACHED TO MAIN RUNNERS. <br />5. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAIN AND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE <br />END TEE, WHICHEVER IS LEAST FOR THE PERIMETER OF THE CEILING AREA. THE LENGTH OF THE END TEE IS EIGHT (8) INCHES OR LESS. <br />6. PROVIDE TRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT OBSTRUCTIONS TO TYPICAL HANGER SPACING (HANGERS, STRUTS OR BRACES AS REQUIRED AT ALL CEILING BREAKS, <br />SOFFITS, OR DISCONTINUOUS, AREAS. HANGER WIRES THAT ARE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB ARE TO HAVE COUNTER-SLOPING WIRES. PERIMETER HANGER WIRES <br />AT MAIN RUNNERS THAT ARE POSITIVELY ATTACHED TO THE PERIMETER CLOSURE ANGLE, COUNTER-SLOPING IS OPTIONAL. <br />NOTE: SEE ASTM C-636 FIGURE 1 FOR COUNTER-SLOPING METHODS. <br />7. CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS PER ASTM E580 SECTION 5.2.3 CEILING GRID MEMBERS SHALL BE AT LEAST 3/4 INCH CLEAR OF OTHER WALLS. IF <br />WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE, AND A MINIMUM OF 3/4" INCH CLEAR OF WALL. <br />8. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL NOT BE LESS THAN TWO (2) INCHES. <br />9. AT THE PERIMETER OF THE CEILING AREA WHERE MAIN OR CROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL, PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AND THE <br />FREE END TO PREVENT LATERAL SPREADING. A METAL STRUT OR A #16 GAGE WIRE WITH A POSITIVE MECHANICAL CONNECTION TO THE RUNNER MAY BE USED. WHERE THE PERPENDICULAR <br />DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER IS 12 INCHES OR LESS, THIS INTERLOCK IS NOT REQUIRED. <br />10. EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS. - N/A <br />11. PROVIDE LATERAL-FORCE BRACING ASSEMBLIES CONSISTING OF A COMPRESSION STRUT AND FOUR (4) #12 GAGE SPLAYED BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER. -SEE <br />DETAIL 3 / A0.4.4 <br />EXCEPTION: LATERAL BRACING MAY BE OMITTED FOR SUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING AREA OF 144 SQUARE FEET OR LESS, AND FIRE RATED SUSPENDED ACOUSTICAL <br />CEILING SYSTEMS WITH A CEILING AREA OF 96 SQUARE FEET OR LESS, WHEN PERIMETER SUPPORT IN ACCORDANCE WITH DSA IR 25-2.10 AND ASTM E580 SECTIONS 5.2.2 AND 5.2.3 ARE PROVIDED <br />AND PERIMETER WALLS ARE DESIGNED TO CARRY THE CEILING LATERAL FORCES. <br />12. THE SPACING OF THE BRACING ASSEMBLIES ARE SHOWN ON THE CONSTRUCTION DOCUMENTS. PROVIDE BRACING ASSEMBLIES AT LOCATIONS NOT MORE THAN ONE HALF (1/2) THE <br />CALCULATED SPACING IN EACH DIRECTION FROM EACH PERIMETER WALL AND AT THE EDGES OF ANY CHANGE IN ELEVATION OF THE CEILING. SUBSTANTIATING CALCULATIONS OR TEST REPORTS <br />FOR THE BRACING ASSEMBLIES ARE WAIVED IF THE FOLLOWING REQUIREMENTS ARE MET: <br />A. BRACING ASSEMBLIES SPACED AT A MAXIMUM OF 12 FEET BY 12 FEET ON CENTERS FOR SCHOOL BUILDINGS AND 8 FEET BY 12 FEET ON CENTERS FOR ESSENTIAL SERVICES BUILDINGS. <br />B. THE MAXIMUM SLENDERNESS RATIO (KL/R) OF THE COMPRESSION STRUT IS 200 OR LESS. <br />13. THE SLOPE OF BRACING WIRES SHALL NOT EXCEED 45 DEGREES FROM THE PLANE OF THE CEILING AND WIRES SHALL BE TAUT. SPLICES IN WIRES ARE NOT PERMITTED WITHOUT SPECIAL DSA <br />APPROVAL. <br />14. COMPRESSION STRUTS SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB. <br />15. FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET A SEISMIC SEPARATION JOINT SHALL BE PROVIDED IN ACCORDANCE WITH DETAIL TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING <br />2500 SQUARE FEET. ALTERNATIVELY, STRUCTURAL ANALYSIS SHALL BE PERFORMED TO DEMONSTRATE COMPLIANCE WITH ASTM E580-08 SECTION 5.2.9. <br />16. PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL <br />HAVE A TWO (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF ONE (1) INCH IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, SWING <br />JOINTS MAY BE PROVIDED PER ASTM E580 SECTION 5.2.8.8, A FLEXIBLE HOSE FITTING THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT SHALL BE PERMITTED TO BE USED IN LIEU OF THE <br />OVERSIZED RING, SLEEVE OR ADAPTER. <br />17. FASTEN #12 HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT TURNS IN 3 INCHES. HANGER WIRE LOOP SHALL BE TIGHTLY WRAPPED AND SHARPLY BENT TO PREVENT ANY VERTICAL <br />MOVEMENT OR ROTATION OF THE MEMBER WITHIN THE LOOPS (SEE ASTM E580, SECTION 5.2.7.2). <br />18. FASTEN #10 GAGE OR #12 GAGE BRACING WIRES WITH FOUR (4) TIGHT TURNS. MAKE ALL TIGHT TURNS WITHIN A DISTANCE OF 1-1/2 INCHES. HANGER OR BRACING WIRE <br />ANCHORS TO THE STRUCTURE SHOULD BE INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHOR ALIGNS AS CLOSELY AS POSSIBLE WITH THE DIRECTION OF THE WIRE. <br />19. SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST SIX (6) INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC. HANGER WIRES SHALL NOT ATTACH TO OR BEND <br />AROUND INTERFERING MATERIAL OR EQUIPMENT. <br />20. WHEN DRILLED-IN CONCRETE ANCHORS OR SHOT-IN ANCHORS ARE USED IN REINFORCED CONCRETE FOR HANGER WIRES, 1 OUT OF 10 WIRE/ANCHOR ASSEMBLIES MUST BE FIELD <br />TESTED FOR 200 LBS. IN TENSION. WHEN DRILLED-IN CONCRETE ANCHORS ARE USED FOR BRACING WIRES, 1 OUT 2 WIRE/ ANCHOR ASSEMBLIES MUST BE FIELD TESTED FOR 440 LBS. IN TENSION IN <br />THE DIRECTION OF THE WIRE. SHOT-IN ANCHORS IN CONCRETE ARE NOT PERMITTED FOR BRACING WIRES. <br />NOTE: DRILLED-IN OR SHOT-IN ANCHORS REQUIRE SPECIAL DSA APPROVAL PRIOR TO USE IN PRESTRESSED CONCRETE. <br />21. ALL FIXTURES, TERMINALS, AND OTHER DEVICES SHALL BE MOUNTED IN A MANNER THAT WILL NOT COMPROMISE CEILING PERFORMANCE IN ACCORDANCE WITH SECTION 13.5.6.2.2 (5) OF <br />ASCE 7-05 AS AMENDED BY 2010 CBC SECTION 1615A.1.16 (1615.10.13*) AND ASTM E580 SECTIONS 5.3 AND 5.4. <br />22. CEILING PANELS SHALL NOT SUPPORT ANY LIGHT FIXTURES, AIR TERMINALS OR DEVICES. <br />23. ATTACH ALL LIGHT FIXTURES AND CEILING MOUNTED AIR TERMINALS, TO THE CEILING GRID RUNNERS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE FIXTURES. SCREWS <br />OR APPROVED FASTENERS ARE REQUIRED. MINIMUM OF TWO ATTACHMENTS ARE REQUIRED AT EACH LIGHT FIXTURE PER ASTM E580 SECTION 5.3.1. <br />24. RECESSED OR DROP-IN LIGHT FIXTURES, GRILLES, MECHANICAL TERMINALS, AND FLEXIBLE SPRINKLER HOSE FITTINGS OR OTHER SERVICES BE SUPPORTED DIRECTLY ON RUNNERS <br />CLASSIFIED AS ASTM HEAVY DUTY, BUT THEY MUST ALSO HAVE A MINIMUM OF TWO (2) #12 GAGE SLACK SAFETY WIRES ATTACHED TO THE FIXTURE AT DIAGONAL CORNERS AND ANCHORED TO THE <br />STRUCTURE ABOVE. <br />25. ALL FLUSH OR RECESSED LIGHT FIXTURES, MECHANICAL TERMINALS, AND FLEXIBLE SPRINKLER HOSE FITTINGS OR OTHER SERVICES WEIGHING 56 LBS OR MORE MUST BE INDEPENDENTLY <br />SUPPORTED BY NOT LESS THAN FOUR (4) TAUT #12 GAGE WIRES ATTACHED TO THE HOUSING AND TO THE STRUCTURE ABOVE. THE FOUR (4) TAUT #12 GAGE WIRES, INCLUDING THEIR <br />ATTACHMENT TO THE STRUCTURE ABOVE, MUST BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT. ALL 4FT. X 4FT. LIGHT FIXTURES MUST HAVE SLACK SAFETY WIRES AT EACH <br />CORNER. <br />26. SURFACE-MOUNTED FIXTURES SHALL BE ATTACHED TO THE MAIN RUNNER WITH AT LEAST TWO POSITIVE CLAMPING DEVICES MADE OF MATERIAL WITH A MINIMUM #14 GAGE. ROTATIONAL <br />SPRING CATCHES DO NOT COMPLY. A #12 GAGE SUSPENSION WIRE SHALL BE ATTACHED TO EACH CLAMPING DEVICE TO THE STRUCTURE ABOVE. PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT <br />FIXTURES ARE 8FT. OR LONGER. MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED 8 FEET. <br />27. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF <br />SUPPORTING TWO (2) TIMES THE WEIGHT OF THE FIXTURE. A BRACING ASSEMBLY, PER DETAIL 16/A5-73, IS REQUIRED WHERE THE PENDANT HANGER PENETRATES THE CEILING. SPECIAL DETAILS ARE <br />REQUIRED TO ATTACH THE PENDANT HANGER TO THE BRACING ASSEMBLY TO TRANSMIT HORIZONTAL FORCE. IF THE PENDANT MOUNTED LIGHT FIXTURE IS DIRECTLY AND INDEPENDENTLY BRACED <br />BELOW THE CEILING, I.E. AIRCRAFT CABLES TO WALLS, THEN BRACE ASSEMBLY IS NOT REQUIRED ABOVE THE CEILING. SEE IR 16-9 FOR ADDITIONAL REQUIREMENT FOR PENDANT MOUNTED FIXTURES. <br />28. ALL LIGHT-WEIGHT MISCELLANEOUS DEVICES, SUCH AS STROBE LIGHTS, SPEAKERS, ETC., SHALL BE ATTACHED TO THE CEILING GRID PER SECTION 7.1 OR IR 25-2.10. IN ADDITION, DEVICES <br />WEIGHING MORE THAN 10 LBS SHALL HAVE A #12 SLACK SAFETY WIRE ANCHORED TO THE STRUCTURE ABOVE. DEVICES WEIGHING 20 LBS OR MORE SHALL BE SUPPORTED FROM THE STRUCTURE <br />ABOVE PER SECTION 7.3 OR IR 25-2.10. <br />29. FIRE RATED CEILINGS: THE COMPONENTS AND INSTALLATION SHALL CONFORM IN EVERY RESPECT WITH U.L. LISTED DETAILS. POP RIVETS, SCREWS, OR OTHER ATTACHMENTS ARE NOT <br />ACCEPTABLE UNLESS SPECIFICALLY DETAILED AND APPROVED BY U.L. AND STATE FIRE MARSHALL RECOGNIZED LABORATORIES. <br />30. METAL PANELS AND PALELS WEIGHING MORE THAN 1/2 PSF, OTHER THAN MINERAL FIBER ACOUSTICAL TILE, ARE TO BE POSITIVELY ATTACHED TO THE CEILING SUSPENSION RUNNERS. <br />31. THE CEILING GRID SYSTEM MUST BE RATED AS HEAVY DUTY AS DEFINED BY ASTM C635. A LIST OF ACCEPTABLE GRID SYSTEMS SHOWN BELOW. THE GRID SYSTEMS SPECIFIED MUST BE <br />ACCEPTABLE IN ACCORDANCE WITH IR A-5. THE FOLLOWING INFORMATION MUST BE INCLUDED ON THE DRAWINGS FOR EACH ACCEPTABLE GRID SYSTEM SPECIFIED: <br />CLASSIFICATION OF CEILING GRID IS HEAVY DUTY. <br />MANUFACTURER'S CATALOG NUMBER - MAIN RUNNER (1) (2) <br />MANUFACTURER'S CATALOG NUMBER - CROSS RUNNER (2) <br />MANUFACTURER'S CATALOG NUMBER OF DETAIL FOR RUNNER SPLICE (2) <br />(1) RUNNERS MUST BE RATED AS HEAVY DUTY. <br />(2) SHOW MANUFACTURER, DUTY CLASSIFICATION AND CATALOG NUMBERS. <br />CLASSIFICATION OF CEILING GRID: HEAVY DUTY <br />CEILING GRID MANUFACTURERS AND PRODUCT SYSTEMS: <br />NOTE: SYSTEM COMPONENTS, MATERIALS, RUNNER SPLICES, AND <br />INSTALLATION SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS <br />OF THE CALIFORNIA BUILDING CODE, THE RESPECTIVE I.C.C. EVALUATION <br />REPORT, AND THE DSA PRODUCT APPROVAL (PA) LISTED BELOW FOR EACH <br />MANUFACTURER AND SYSTEM. <br />USG INTERIORS, INC. <br />DONN DX SYSTEM (NON-RATED) <br />DONN DXL SYSTEM (FIRE-RATED) <br />ICC EVALUATION SERVICE REPORT NO. ER-2244 <br />DSA PA-030 <br />1/4" = 1'-0"3SUSPENDED CEILING SCHEMATIC PLAN1 <br />3" = 1'-0"5COMPRESSION POST1 <br />3" = 1'-0"9WALL/SUSPENDED CEILING INTERSECTION1 <br />1/8" = 1'-0"2ISOMETRIC OF SUSPENDED CEILING BRACING ASSEMBLY1 <br />3" = 1'-0"4TYP. SADDLE TIE @ TRAPEZE1 <br />3" = 1'-0"8WIRE ATTACHMENT AT STRUCTURAL STEEL1 <br />3" = 1'-0"7WIRE ATTACHMENT AT COMPOSITE DECK1 <br />3" = 1'-0"6WIRE ATTACHMENT AT STEEL DECK1 <br />3" = 1'-0"1TYP. PERIMETER CEILING TILE1 <br />25 <br />No.Description Date