Laserfiche WebLink
FINISH FLOOR <br />0" <br />ROOF <br />15' -0" <br />1 <br />A3.00 <br />(E) FOUNDATION <br />-2' -0" <br />2 <br />A3.00 <br />9' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />123 <br />TRAINING ROOM <br />B <br />03 <br />MULTI-PURPOSE <br />ROOM A <br />02 <br />07-09 <br />05-08 <br />07-04 <br />07-04 <br />05-08 <br />07-02 <br />07-09 <br />A5.03 <br />16 <br />A3.10 <br />1 <br />Sim <br />A3.10 <br />2 <br />Sim <br />TYP. <br />03-05 <br />03-04 03-02 <br />2 <br />A5.05 <br />2 <br />A5.05 <br />13 <br />A5.0513 <br />A5.05 <br />1 <br />A5.05 <br />FINISH FLOOR <br />0" <br />ROOF <br />15' -0" <br />1 <br />A3.00 <br />(E) FOUNDATION <br />-2' -0" <br />2 <br />A3.00 <br />123 <br />TYP. <br />07-02 <br />TYP. <br />07-09 <br />05-08 <br />05-08 <br />07-12 <br />A3.10 <br />2 <br />A3.10 <br />3 <br />Sim <br />A5.02 <br />6 <br />23-03 <br />23-07 <br />03-05 03-04 <br />2 <br />A5.05 <br />2 <br />A5.05 <br />1 <br />A5.05 <br />23-08 <br />GENERAL NOTES <br />1. REFER TO ADDITIONAL NOTES ON SHEET T0.001. <br />2. CONTRACTOR SHALL VERIFY THAT (E) CONDITIONS ARE AS INDICATED ON THE DRAWINGS. <br />NOTIFY THE ARCHITECT IMMEDIATELY OF VARIATIONS OR DISCREPANCIES. DO NOT PROCEED <br />WITH AFFECTED WORK UNTIL THE VARIATIONS OR DISCREPANCIES ARE RESOLVED BY THE <br />ARCHITECT. <br />3. RESTORE ALL SURROUNDING AREAS AFFECTED BY THE WORK. PROTECT ALL EXISTING ITEMS <br />THAT ARE TO REMAIN. <br />4. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD. DIMENSIONS ARE TO FACE OF FINISHED WALL, <br />U.O.N. DIMENSIONS OF (E) CONDITIONS ARE FOR REFERENCE ONLY AND SHALL BE VERIFIED BY <br />THE CONTRACTOR IN THE FIELD. WHERE NO DIMENSION IS PROVIDED CONSULT WITH THE <br />ARCHITECT FOR CLARIFICATION BEFORE PROCEEDING WITH AFFECTED WORK. <br />5. WHERE ORIGINAL MATERIALS REMAIN AND ARE SALVAGEABLE, ORIGINAL MATERIALS SHALL BE <br />REPAIRED AS NEEDED. IF DETERIORATION IS BEYOND REPAIR OR ORIGINAL BUILDING FEATURES <br />ARE MISSING, ALL NEW MATERIALS SHALL MATCH ORIGINALS AS CLOSE AS POSSIBLE AND MEET <br />THE SECRETARY OF THE INTERIOR'S STANDARDS FOR REHABILITATION. <br />6. ALL DOORS AND WINDOWS PLACEMENT IS SHOWN PER THE ORIGINAL DRAWINGS AND HAVE NOT <br />BEEN VERIFIED FOR AS-BUILT LOCATIONS DUE TO THE SECURITY MEASURES IN PLACE ON THE <br />EXTERIOR OF THE BUILDING. <br />7. DOORS HAVE BEEN REMOVED AND SOME WINDOW CASING REMAINS IN SOME OF THE WINDOWS. <br />COMPLETE INTACT WINDOWS HAVE NOT BEEN VERIFIED DUE TO SECURITY MEASURES IN PLACE <br />ON SITE. <br />8. WHERE DOORS AND WINDOWS ARE NO LONGER IN PLACE, NEW WOOD DOOR AND WINDOWS ARE <br />TO BE INSTALLED TO MATCH ORIGINAL DRAWINGS. <br />9. PREP AND PAINT ALL PLASTER WALLS. PATCH AND REPAIR AREAS AS REQUIRED, FOR COST <br />ESTIMATE ASSUME 10% OF THE AREA NEEDS PATCHING. REPAIR ANY DAMAGED OR MISSING <br />MOLDINGS TO MATCH ADJACENT PROFILE. <br />10. (E) TRUSSES AND NEW CEILING AND ROOF FRAMING SHOWN FOR REFERENCE ONLY. REFER TO <br />STRUCTURAL DRAWINGS FOR MORE DETAIL INFORMATION. ALL (E) CONDITIONS TO BE FIELD <br />VERIFIED. <br />11. MECHANICAL EQUIPMENT, LIGHT FIXTURES AND UTILITY LOCATIONS TO BE COORDINATED IN THE <br />FIELD WITH (E) TRUSSES AND NEW FRAMING. <br />LEGENDKEYNOTES <br />xx <br />00 <br />WINDOW TAG, REFER TO SHEET A6.02 FOR WINDOW SCHEDULE <br />DOOR TAG, REFER TO SHEET A6.00 FOR DOOR SCHEDULE <br />LIGHT FIXTURE TAG, REFER TO SHEET A1.20 FOR FIXTURE SCHEDULE Fx <br />AREA OF DEMO <br />AREA OF PATCH AND/OR REPAIR, REFER TO KEYNOTE <br />NEW SHEAR WALL SHEATHING, REFER TO STRUCTURAL DRAWINGS <br />2x WOOD STUDS @ 16" O.C., MATCH ADJACENT WALL ASSEMBLY <br />EXISTING WOOD STUD WALL TO REMAIN <br />-NEW GYP BD SHEATHING ON INTERIOR SIDE(S) OF ALL (E) WALLS, TYP. <br />-ALL EXTERIOR WALLS TO RECEIVE R-19 BATT INSULATION <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />1/4" = 1'-0" <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />1 <br />: <br />5 <br />4 <br /> <br />P <br />M <br />A3.01 <br />BUILDING <br />SECTIONS <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />1/4" = 1'-0"A3.01 <br />1 NORTH/ SOUTH SECTION #1 <br />1/4" = 1'-0"A3.01 <br />2 NORTH / SOUTH SECTION #2 <br />03-02 CONCRETE SLAB ON GRADE INFILL OVER VAPOR RETARDER, REFER TO STRUCTURAL DRAWINGS <br />AND GEOTECH REPORT <br />03-04 CLEAN AND POLISH (E) CONCRETE FLOOR. EXISTING SCORING TO REMAIN. <br />03-05 (E) FOOTING TO REMAIN, PROTECT IN PLACE <br />05-08 PARAPET CAP <br />07-02 TPO MEMBRANE ROOFING SYSTEM OVER COVER BOARD OVER PLYWOOD SHEATHING PER <br />STRUCTURAL DWGS, OVER (E) 1X6 SHEATHING; PROVIDE TAPERED INSULATION AS REQUIRED TO <br />MAINTAIN MINIMUM SLOPE REQUIREMENTS <br />07-04 ORIGINAL CLAY TILE ROOF TO BE SALVAGED, CLEANED AND RESTORED, OVER PLYWOOD <br />SHEATHING PER STRUCTURAL DWGS, OVER (E) 1X6 SHEATHING; NEW REPLACEMENT TILE TO BE <br />SOURCED FROM GLADDING MCBEAN AT BROKEN TILES TO MATCH ORIGINAL SHAPE AND COLOR <br />BLEND AND INSTALL NEW BIRD STOPS AT END TILES <br />07-09 EXTERIOR WALLS TO RECEIVE R-19 BATT INSULATION <br />07-12 R-30 BATT INSULATION AT UNDERSIDE OF ROOF DECK <br />23-03 HVAC CONDENSING UNIT, FLOOR MOUNTED TO 6" CONCRETE HOUSEKEEPING PAD, REFER TO <br />MECHANICAL & STRUCTURAL DWGS. <br />23-07 HVAC CONDENSING UNIT, WALL MOUNTED, REFER TO MECHANICAL AND STRUCUTRAL DWGS. <br />23-08 EXHAUST FAN, REFER TO MECHANICAL DRAWINGS <br />No. Description Date <br />DESIGN DEVELOPMENT 1/12/2024 <br />75% CD 3/15/2024 <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025