Laserfiche WebLink
16 <br />A5.00 <br />TILE BACKWARD PER FINISH <br />SCHED. <br />SPOUT MUST PROVIDE A FLOW <br />OF WATER AT 4" HIGH. <br />HI / LO DRINKING <br />FOUNTAINS WHERE IT <br />OCCURS <br />TILE BASE PER FINISH <br />SCHEDULE <br />NOTES: <br />1. IF "X" IS GREATER THAN 24" <br />THEN "Y" SHALL BE 18". <br />2. FORCE TO ACTIVATE <br />CONTROLS NOT TO EXCEED 5 lbs. <br />3 1/2 <br />" <br /> <br />MAX. <br />18" MIN.48" MIN. CLR <br />48" MIN.CLRF.F.27 <br />" <br /> <br />M <br />I <br />N <br />. <br />F.F. <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br />38 <br />" <br /> <br />- <br /> <br />4 <br />3 <br />" <br />16" MIN. <br />Y20 <br />A5.00 <br />EQ EQ <br />SEE PLAN FOR WIDTH <br />SE <br />E <br /> <br />R <br />E <br />F <br />L <br />E <br />C <br />T <br />E <br />D <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br /> <br />P <br />L <br />A <br />N <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />A <br />L <br />L <br /> <br />O <br />P <br />E <br />R <br />A <br />B <br />L <br />E <br /> <br />P <br />A <br />R <br />T <br />S <br />36 <br />" <br /> <br />- <br /> <br />4 <br />3 <br />" <br /> <br />T <br />O <br /> <br />B <br />U <br />B <br />B <br />L <br />E <br />R <br />36 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />B <br />U <br />B <br />B <br />L <br />E <br />R <br />27 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />C <br />L <br />E <br />A <br />R <br />16" MIN. <br />FIN. FLR <br />TILE BACK WALL, WHERE <br />OCCURS, FOR MORE <br />INFO, REFER TO INTERIOR <br />ELEVATIONS & FINISH SCHED. <br />OPTIONAL ACCESS PANEL, TOP & <br />BOT. <br />BOTTLE FILLER, WHERE OCCURS <br />PER PLANS <br />DUAL HEIGHT DRINKING <br />FOUNTAIN, FOR ATTACHMENT <br />SEE <br />TILE BASE, FOR MORE INFO REFER <br />TO INTERIOR ELEVATIONS & <br />FINISH SCHED. <br />℄ <br />CEILING LINE <br />2X WOOD STUD FRAMING WALL, <br />SEE PLANS <br />WALL FINISH PER SCHEDULE <br />DRINKING FOUNTAIN & MOUNTING <br />PLATE BY MANUF. <br />3/8" DIA. MACHINE BOLT. TYP. <br />6X WOOD BLOCKING WITH <br />SIMPSON A34 AT TOP & <br />BOT. EA. END TYP. <br />1/4"X2" SQ. WASHER., TYP. <br />℄ <br />27 <br />" <br /> <br />M <br />I <br />N <br />TO <br /> <br />F <br />. <br />F <br />. <br />36 <br />" <br /> <br />M <br />A <br />X <br />TO <br /> <br />B <br />U <br />B <br />B <br />L <br />E <br />R <br />38 <br />" <br /> <br />- <br /> <br />4 <br />3 <br />" <br /> <br />M <br />A <br />X <br />TO <br /> <br />B <br />U <br />B <br />B <br />L <br />E <br />R <br />3 1/2" MAX. <br />1' - 3" MIN. <br />MAXIMUM <br />6" <br />67 <br />OCCUPANCY <br />10" <br />1" <br />1" <br />1/ <br />2 <br />" <br />1" <br />1/ <br />2 <br />" <br />1" <br />1" <br />NOTE: <br />EVERY ROOM OR SPACE THAT IS AN ASSEMBLY OCCUPANCY SHALL HAVE THIS SIGN <br />POSTED IN A CONSPICUOUS PLACE NEAR THE MAIN EXIT OF EXIT ACCESS DOORWAY, <br />PER CBC 10004.3 <br />1" HIGH LETTERS <br />PORCELAIN OR BAKED ON <br />ENAMEL ON STEEL OR 0,050 <br />GA. T-3 ALUMN. <br />LETTERS TO BE WHITE ON <br />CONTRASTING COLOR <br />BACKGROUND, COLOR TBD <br />BY ARCHITECT <br />EQUAL <br />EQ <br />U <br />A <br />L <br />WHITE BORDER <br />BLUE BACKGROUND <br />THE COLOR BLUE SHALL <br />APPROXIMATE FS 15090 IN <br />FEDERAL STANDARD 595C <br />WHITE FIGURE <br />NOTE: <br />1. GRID LINES ARE SHOWN FOR PROPORTION ONLY AND ARE NOT TO APPEAR <br />AS PART OF THE SYMBOL. <br />2. REFER TO CBC 11B-703.7.2.1 <br />48 <br />" <br /> <br />M <br />A <br />X <br />MI <br />N <br />. <br />15 <br />" <br />MAX. <br />10" <br />UNOBSTRUCTED SIDE REACH <br />46 <br />" <br /> <br />M <br />A <br />X <br />TO 24" MAX <br />MORE THAN 10" <br />34 <br />" <br /> <br />M <br />A <br />X <br />48 <br />" <br /> <br />M <br />A <br />X <br />MAX <br />10" <br />34 <br />" <br /> <br />M <br />A <br />X <br />OBSTRUCTED HIGH SIDE REACH OBSTRUCTED HIGH SIDE REACH <br />UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH <br />MI <br />N <br />15 <br />" <br />48 <br />" <br /> <br />M <br />A <br />X <br />20" MAX <br />48 <br />" <br /> <br />M <br />A <br />X <br />OBSTRUCTED HIGH FORWARD REACH <br />TO 25" MAX <br />GREATER THAN 20" <br />44 <br />" <br /> <br />M <br />A <br />X <br />27 <br />" <br /> <br />M <br />I <br />N <br />27 <br />" <br /> <br />M <br />I <br />N <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />24" MIN. @ EXTERIOR <br />18" MIN @ INTERIOR <br />FRONT APPROACH, PULL SIDE <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />FRONT APPROACH, PUSH SIDE <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />36" MIN <br />HINGE APPROACH, PULL SIDE <br />44 <br />" <br /> <br />M <br />I <br />N <br />. <br />* <br />HINGE APPROACH, PUSH SIDE <br />WITH BOTH CLOSER & LATCH <br />12" MIN. IF DOOR PROVIDED <br />MIN <br />22" <br />60 <br />" <br /> <br />M <br />I <br />N <br />. <br />24" MIN <br />LATCH APPROACH, PULL SIDE <br />HINGE APPROACH, PUSH SIDE <br />MIN <br />24" <br />*48" IF DOOR <br />PROVIDED WITH <br />CLOSER & LATCH <br />44 <br />" <br /> <br />M <br />I <br />N <br />* <br />*48" IF DOOR <br />PROVIDED WITH <br />CLOSER & LATCH <br />CLR, TYP <br />32" MIN <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />FRONT APPROACH SIDE APPROACH <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />POCKET OR HINGE APPROACH STOP OR LATCH APPROACH <br />42 <br />" <br /> <br />M <br />I <br />N <br />. <br />MIN. <br />22" <br />MIN. <br />24" <br />10 <br />" <br />80 <br />" <br /> <br />M <br />I <br />N <br />IN GROUP B OCCUPANCIES, KEY-LOCKING <br />HARDWARE MAY BE USED IF SIGN STATING <br />"THIS DOOR TO REMAIN UNLOCKED WHEN <br />THIS SPACE IS OCCUPIED" IS PROVIDED AT <br />INTERIOR SIDE OF DOOR; LETTERS TO BE 1" <br />HIGH <br />CLOSER, WHERE PROVIDED <br />RATED DOOR - 5 LBS MAX PRESSURE <br />FIRE DOOR - 15 LBS MAX PRESSURE <br />NOTES: <br />1. EXIT DOORS SHALL BE OPERABLE FORM THE INSIDE WITHOUT THE USE OF A KEY OR ANY <br />SPECIAL KNOWLEDGE OR EFFORT. <br />2. SURFACE SLOPE OF THE LEVEL AREA TO HAVE A MAX SLOPE OF 1:48. <br />3. DOOR CLOSER, IF PROVIDED, MUST BE SET SO THAT IS TAKES A DOOR AT LEAST 5 <br />SECONDS TO CLOSE FROM A 90 DEGREE POSITION TO A 12 DEGREE POSITION. <br />OPERABLE DOOR HARDWARE: <br />SINGLE EFFORT LEVER TYPE HARDWARE; <br />PANIC BAR; OR PUSH-PULL HARDWARE, <br />PER DOOR HARDWARE SPECIFICATIONS <br />SMOOTH UNINTERRUPTED SURFACE OR <br />SMOOTH PANEL ON PUSH SIDE OF DOOR <br />TO <br /> <br />B <br />O <br />T <br />T <br />O <br />M <br />34 <br />" <br /> <br />M <br />I <br />N <br />TO <br /> <br />T <br />O <br />P <br />44 <br />" <br /> <br />M <br />A <br />X <br />1/4" THK EQUILATERAL <br />TRIANGLE SYMBOL; 1/4" <br />MAX FROM EDGE OF <br />CIRCLE <br />1/4" THK CIRCLE <br />SYMBOL <br />GEOMETRIC DOOR SYMBOL: <br />UNISEX DOOR SYMBOL <br />12" <br />1/4" THK <br />TOILET ROOM TACTILE SIGN: <br />UNISEX TACTILE SIGN <br />NOTES: <br />1. ALL TEXT/GRAPHICS TO BE WHITE ON CONTRASTING BACKGROUND, TYP. BACKGROUND COLOR <br />TBD BY ARCHITECT, TYP. <br />2. THE COLOR OF THE DOOR SYMBOL SHALL CONTRAST WITH THE DOOR OR SURFACE ON WHICH <br />THE SYMBOL IS MOUNTED, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT <br />BACKGROUND. FOR THE UNISEX SYMBOL, THE COLOR OF THE TRIANGLE SYMBOL SHALL <br />CONTRAST WITH THE COLOR OF THE CIRCLE SYMBOL, EITHER LIGHT ON A DARK BACKGROUND <br />OR DARK ON A LIGHT BACKGROUND. THE COLOR OF THE CIRCLE SYMBOL SHALL CONTRAST <br />WITH THE DOOR OR SURFACE ON WHICH THE SYMBOL IS MOUNTED, EITHER LIGHT ON A DARK <br />BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />3. WALL MOUNTED SIGNAGE TO BE LOCATED ON LATCH SIDE OF DOOR CLEAR OF DOOR SWING. <br />LETTERING SHALL BE UPPERCASE CHARACTERS WITH CORRESPONDING CALIFORNIA GRADE II <br />BRAILLE. <br />4. FOR SIGNAGE REQUIREMENTS REFER TO DETAIL 14 <br />A5.00 <br />RESTROOM <br />6" <br />6" <br />1/4" THK <br />EQUILATERAL <br />TRIANGLE SYMBOL <br />MALE DOOR SYMBOL <br />1/4" THK <br />PANEL <br />MALE TACTILE SIGN <br />MEN'S <br />FI <br />E <br />L <br />D <br />6" <br /> <br />M <br />I <br />N <br />PI <br />C <br />T <br />O <br />G <br />R <br />A <br />M <br />6" <br />1/4" THK CIRCLE <br />SYMBOL <br />WOMEN DOOR SYMBOL <br />12" <br />WOMEN TACTILE SIGN <br />WOMEN'S <br />6" <br />9" <br />1/32" RAISED <br />PICTOGRAM <br />5/8" TALL, 1/32" <br />RAISED TEXT <br />CALIFORNIA <br />GRADE II <br />BRAILLE <br />...... <br />1/4" THK <br />PANEL <br />FI <br />E <br />L <br />D <br />6" <br /> <br />M <br />I <br />N <br />PI <br />C <br />T <br />O <br />G <br />R <br />A <br />M <br />9" <br />1/32" RAISED <br />PICTOGRAM <br />5/8" TALL, 1/32" <br />RAISED TEXT <br />CALIFORNIA <br />GRADE II <br />BRAILLE <br />...... <br />1/32" RAISED <br />PICTOGRAM <br />5/8" TALL, 1/32" <br />RAISED TEXT <br />CALIFORNIA <br />GRADE II <br />BRAILLE <br />...... <br /> 12" <br />EDGES AND VERTICES ON GEOMETRIC DOOR SYMBOLS (NTS): <br />RADIUS @ VERTICES EDGES -EASED/ROUNDED OR CHAMFERED <br />1/8" MIN -1/4" MAX <br />EASED EDGE, <br />1/16" MIN <br />CHAMFERED, <br />1/8" MAX <br />ISA <br />ISA <br />ISA <br />VE <br />R <br />T <br />I <br />C <br />A <br />L <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />W/ <br /> <br />B <br />E <br />V <br />E <br />L <br />E <br />D <br /> <br />S <br />L <br />O <br />P <br />E <br />1/ <br />2 <br />" <br /> <br />M <br />A <br />X <br />1/ <br />4 <br />" <br /> <br />M <br />A <br />X <br />1 <br />2 <br />DOOR PER SCHEDULE <br />METAL THRESHOLD SET IN BED <br />OF MASTIC; MECHANICALLY <br />FASTEN PER MANUFACTURER'S <br />RECOMMENDATIONS <br />1:2 MAX. SLOPE <br />FIRE EXTINGUISHER <br />CABINET <br />PA <br />R <br />T <br /> <br />O <br />F <br /> <br />O <br />P <br />E <br />R <br />A <br />T <br />I <br />N <br />G <br /> <br />H <br />A <br />N <br />D <br />L <br />E <br />/ <br />C <br />O <br />N <br />T <br />R <br />O <br />L <br />S <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />H <br />I <br />G <br />H <br />E <br />S <br />T <br /> <br />FIRE ALARM PULL <br />STATION <br />THERMOSTAT LIGHT SWITCH <br />RECEPTACLE <br />18 <br />" <br />15 <br />" <br /> <br />M <br />I <br />N <br />NOTE: LIGHT SWITCHES AND <br />ELECTRICAL RECEPTACLES ON <br />CIRCUITS OF 30 AMP MAX ARE <br />15" MIN TO 48" MAX A.F.F. <br />MEASURED TO THE BOTTOM & <br />TOP OF THE SWITCH OR <br />OUTLET BOX <br />ALL COUNTER LEVEL WALL <br />OUTLETS REFER TO REACH <br />RANGE DETAIL 9/A5.00. <br />SOAP <br />DISPENSER <br />PAPER <br />TOWEL <br />DISPENSER <br />HAND <br />DRYER <br />NAPKIN <br />TAMPON <br />DISPENSER <br />COMBINED PAPER TOWEL <br />DISPENSER / WASTE <br />RECEPTACLE <br />PA <br />R <br />T <br /> <br />O <br />F <br /> <br />O <br />P <br />E <br />R <br />A <br />T <br />I <br />N <br />G <br /> <br />H <br />A <br />N <br />D <br />L <br />E <br />/ <br />C <br />O <br />N <br />T <br />R <br />O <br />L <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br /> <br />T <br />O <br /> <br />H <br />I <br />G <br />H <br />E <br />S <br />T <br />HOOK, TYP <br />HOOK, <br />ACCESSIBLE <br />60 <br />" <br />48 <br />" <br />TOILET ROOM ACCESSORIES MISCELLANEOUS <br />NOTE: <br />1. ALL HEIGHT DIMENSIONS ARE A.F.F. <br />2. CONTRACTOR TO PROVIDE MOUNTING HEIGHTS INDICATED, VERIFY INTENDED USE PRIOR TO ROUGH IN. PROVIDE BACKING AS REQUIRED. <br />3. THE PROJECTION FROM A SURFACE OR SEMI-RECESSED FIXTURE FROM THE FACE OF THE WALL OR PARTITION SHALL BE LIMITED TO 4" <br />OF <br /> <br />R <br />A <br />I <br />S <br />E <br />D <br /> <br />C <br />H <br />A <br />R <br />A <br />C <br />T <br />E <br />R <br />S <br />58 <br />" <br /> <br />M <br />I <br />N <br /> <br />- <br /> <br />6 <br />0 <br />" <br /> <br />M <br />A <br />X <br /> <br />A <br />F <br />F <br />TO <br /> <br />C <br />E <br />N <br />T <br />E <br />R <br />L <br />I <br />N <br />E <br /> <br />O <br />F <br /> <br />H <br />I <br />G <br />H <br />E <br />S <br />T <br /> <br />L <br />I <br />N <br />E <br />EQ EQ <br />MIN <br />9"DOOR SIGNAGE, <br />WHERE OCCURS <br />WALL SIGNAGE <br />11 <br />A5.00 <br />NOTES: <br />1. SIGNS TO BE LOCATED ADJACENT TO LATCH SIDE OF DOOR. WHERE NO SPACE ON LATCH SIDE <br />IS AVAILABLE, SIGNS TO BE LOCATED AT NEAREST ADJACENT WALL. <br />2. SIGNS TO BE LOCATED ON APPROACH SIDE OF DOOR AS ONE ENTERS ROOM OR SPACE. SIGNS <br />THAT IDENTIFY EXISTS ARE TO BE LOCATED ON APPROACH SIDE OF DOOR AS ONE EXISTS <br />ROOM OR SPACE. <br />3. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3" <br />OF SIGNAGE WITHOUT OBSTRUCTION OR STANDING WITHIN THE SWING OF THE DOOR. <br />4. FOR SIGNAGE REQUIREMENTS AND MOUNTING HEIGHTS REFER TO DETAIL 14 <br />A5.00 <br />MO <br />U <br />N <br />T <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />, <br /> <br />R <br />E <br />F <br />E <br />R <br /> <br />T <br />O <br />14 <br />A5 <br />. <br />0 <br />0 <br />SIGN AT WALL <br />MIN <br />9" <br />WALL SIGNAGE <br />MO <br />U <br />N <br />T <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />, <br /> <br />R <br />E <br />F <br />E <br />R <br /> <br />T <br />O <br />14 <br />A5 <br />. <br />0 <br />0 <br />SIGN AT SIDELIGHT <br />MIN <br />9" <br />WALL SIGNAGE <br />MO <br />U <br />N <br />T <br />I <br />N <br />G <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />, <br /> <br />R <br />E <br />F <br />E <br />R <br /> <br />T <br />O <br />14 <br />A5 <br />. <br />0 <br />0 <br />SIGN AT WINDOW <br />+/-1" FROM CL <br />CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM <br />AND SHALL BE SAN SERIF UPPERCASE CHARACTERS ACCOMPANIED BY <br />CONTRACTED GRADE II BRAILLE. <br />CHARACTER SIZE: RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8" AND A <br />MAXIMUM OF 2" HIGH. <br />FINISH AND CONTRAST: CONTRAST BETWEEN CHARACTERS, SYMBOLS AND <br />THEIR BACKGROUNDS MUST BE 70% MINIMUM AND HAVE A NON-GLARE FINISH. <br />PROPORTIONS: VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM <br />FONTS WHERE THE WIDTH OF THE UPPERCASE LETTER "O" IS 60 PERCENT <br />MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE UPPERCASE <br />LETTER "I". STROKE THICKNESS OF THE UPPERCASE LETTER "I" SHALL BE 10 <br />PERCENT MINIMUM AND 20 PERCENT MAXIMUM OF THE HEIGHT OF THE <br />CHARACTER. <br />BRAILLE: CONTRACTED (GRADE 2) CALIFORNIA BRAILLE SHALL BE USED <br />WHENEVER BRAILLE IS REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. <br />DOTS SHALL BE 1/10" ON CENTER IN EACH CELL WITH 2/10" SPACE BETWEEN <br />CELLS MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO <br />THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS SHALL BE RAISED A <br />MINIMUM OF 1/40" ABOVE THE BACKGROUND. <br />MOUNTING HEIGHT: SIGNS WITH RAISED CHARACTERS AND BRAILLE SHALL BE <br />LOCATED 48" MINIMUM ABOVE THE FINISH FLOOR, MEASURED FROM THE <br />BASELINE OF THE LOWEST LINE OF BRAILLE AND 60" MAXIMUM FROM THE <br />BASELINE BRAILLE OF THE HIGHEST LINE OF RAISED CHARACTERS. <br />EXIT <br />ROUTE <br />5/ <br />8 <br />" <br />- <br />2 <br />" <br />3/ <br />8 <br />" <br />- <br />1 <br />/ <br />2 <br />" <br />3/ <br />8 <br />" <br /> <br />M <br />I <br />N <br />EXIT <br />5/ <br />8 <br />" <br />- <br />2 <br />" <br />3/ <br />8 <br />" <br />- <br />1 <br />/ <br />2 <br />" <br />3/ <br />8 <br />" <br /> <br />M <br />I <br />N <br />60 <br />" <br /> <br />M <br />A <br />X <br /> <br />A <br />F <br />F <br /> <br />T <br />O <br /> <br />B <br />A <br />S <br />E <br />L <br />I <br />N <br />E <br /> <br />O <br />F <br /> <br />HI <br />G <br />H <br />E <br />S <br />T <br /> <br />L <br />I <br />N <br />E <br /> <br />O <br />F <br /> <br />R <br />A <br />I <br />S <br />E <br />D <br /> <br />C <br />H <br />A <br />R <br />A <br />C <br />T <br />E <br />R <br />S <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />A <br />F <br />F <br /> <br />T <br />O <br /> <br />B <br />A <br />S <br />E <br />L <br />I <br />N <br />E <br /> <br />O <br />F <br />LO <br />W <br />E <br />S <br />T <br /> <br />L <br />I <br />N <br />E <br /> <br />O <br />F <br /> <br />B <br />R <br />A <br />I <br />L <br />L <br />E <br />CONTRACTED (GRADE 2) <br />CA BRAILLE RAISED .025" <br />MIN TO .037 MAX FROM <br />THE BACKGROUND <br />CHARACTERS SHALL BE RAISED 1/32" MIN FROM BACKGROUND, <br />UPPER CASE, SANS SERIF TYPE AND ACCOMPANIED WITH GRADE <br />2 BRAILLE. RAISED CHARACTERS SHALL BE AT LEAST 5/8" HIGH, <br />BUT NO HIGHER THAN 2". BRAILLE TO BE POSITIONED BELOW THE <br />RAISED CHARACTER TEXT WITH 3/8" MIN TO 1/2" MAX SPACE <br />FROM TEXT. BRAILLE SHALL BE CENTERED DIRECTLY UNDER THE <br />TACTILE LETTERING OR JUSTIFIED LEFT. <br />NOTES: <br />1. FOR SIGNAGE REQUIREMENTS, REFER TO DETAIL 14 <br />A5.00 <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />As indicated <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />2 <br />: <br />2 <br />1 <br /> <br />P <br />M <br />A5.00 <br />ACCESSIBILITY <br />DETAILS <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />1/2" = 1'-0"A5.00 <br />12 ACCESSIBLE HI/LOW D.F. ALCOVE <br />1/2" = 1'-0"A5.00 <br />16 ACCESS. HI/LOW D.F. ELEVATION <br />1 1/2" = 1'-0"A5.00 <br />20 DRINKING FOUNTAIN ATTACHMENT <br />3" = 1'-0"A5.00 <br />19 MAXIMUM OCCUPANCY SIGN <br />No. Description Date <br />75% CD 3/15/2024 <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />ACCESSIBILITY UPDATES 12/13/2024 <br />BACKCHECK SET_V2 4/8/2025 <br />1" = 1'-0"A5.00 <br />1 INTERNATIONAL SYMBOL OF ACCESSIBILITY (ISA) <br />3/8" = 1'-0"A5.00 <br />9 REACH RANGES <br />1/4" = 1'-0"A5.00 <br />2 DOOR APPROACHES & CLEARANCES <br />3/8" = 1'-0"A5.00 <br />4 DOOR REQUIREMENTS <br />1 1/2" = 1'-0"A5.00 <br />11 RESTROOM SIGNAGE <br />6" = 1'-0"A5.00 <br />8 ACCESSIBLE THRESHOLD, TYPICAL <br />1/2" = 1'-0"A5.00 <br />17 MOUNTING HEIGHTS <br />1/2" = 1'-0"A5.00 <br />10 SIGNAGE @ DOOR <br />1" = 1'-0"A5.00 <br />14 SIGNAGE REQUIREMENTS <br />3" = 1'-0"A5.00 <br />15 TACTILE EXIT SIGN