Laserfiche WebLink
TYPE B1 <br />INTERIOR <br />SINGLE SWING DOOR <br />FLAT 2 PANEL <br />TYPE C1 <br />INTERIOR <br />DOUBLE SWING DOOR <br />TWO LITE <br />REMARKS <br />TYPE A1 <br />INTERIOR <br />OPENING <br />TYPE D1 <br />EXTERIOR <br />SINGLE SWING DOOR <br />WOOD PANEL, UPPER LITE <br />TYPE E <br />EXTERIOR <br />SINGLE SWING DOOR <br />WOOD PANEL <br />TYPE F <br />EXTERIOR <br />DOUBLE SWING DOOR <br />A. WHERE ORIGINAL MATERIALS REMAIN AND ARE SALVAGEABLE, ORIGINAL <br />MATERIALS SHALL BE REPAIRED AS NEEDED. IF DETERIORATION IS BEYOND <br />REPAIR OR ORIGINAL BUILDING FEATURES ARE MISSING, ALL NEW <br />MATERIALS SHALL MATCH ORIGINALS AS CLOSE AS POSSIBLE AND MEET <br />THE SECRETARY OF THE INTERIOR'S STANDARDS FOR REHABILITIATION. <br />B. ANY EXISTING DETAIL OR FEATURE INCLUDING PROFILES, WINDOW LUGS, <br />HARDWARE, ETC IS TO BE RESTORED AND REUSED IF INTACT OR <br />RECREATED TO MATCH ORIGINAL IF MISSING. <br />C. GLAZING AT DOORS AND WINDOWS TO BE TRUE DIVIDED LITES WHERE <br />OCCURS AND TEMPERED GLASS PER GALZING NOTES ON A6.02. <br />D. LABEL, BUNDLE, & BAG ALL SALVAGED HARDWARE TO CORRESPOND TO <br />DOOR SCHEDULE. STRIP & CLEAN SALVAGED HARDWARE AS NEEDED FOR <br />REUSE. <br />E. INSTALL EXTERIOR FLASHING INTEGRATED WITH THE DRAINAGE PLANE <br />(CAL GREEN 5.407.2.2.2) <br />F. ALL DOOR THRESHOLDS TO BE ACCESSIBLE. REFER TO DETAIL <br />TYPE B2 <br />INTERIOR <br />SINGLE SWING DOOR <br />TWO LITE <br />TYPE B3 <br />INTERIOR <br />SINGLE SWING DOOR <br />SINGLE LITE <br />FLAT BOTTOM PANEL <br />TYPE A2 <br />INTERIOR <br />OPENING <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />11. <br />12. <br />13. <br />DOOR FRAME DAMAGED BEYOND REPAIR. REBUILD NEW TO MATCH (E) <br />OPENING. <br />CASING DAMAGED BEYOND REPAIR. REBUILD TO MATCH ORIGINAL. <br />SALVAGE & REUSE (E) HARDWARE. MATCH ORIGINAL WHERE MISSING. <br />ORIGINAL DOOR NO LONGER IN PLACE. REBUILD NEW TO MATCH <br />HISTORICAL DRAWINGS IN (E) OPENING. <br />IF MATERIAL IS SALVAGEABLE. RELOCATE AS NOTED ON PLANS & <br />ELEVATIONS. NOTIFY ARCHITECT AND OWNER IF FRAMES OR CASING <br />CANNOT BE REUSED. <br />SALVAGE AND RESTORE INTACT ORIGINAL MATERIAL. NOTIFY ARCHITECT <br />IF SPECIFIC COMPONENTS CANNOT BE REUSED. <br />INSTALL NEW CROWN CASING TO MATCH ORIGINAL WHERE MISSING. <br />INSTALL NEW APRON TO MATCH ORIGINAL WHERE MISSING. <br />REMOVE ALL BROKEN GLASS AND INSTALL NEW. <br />REPAIR CASING TO MATCH ORIGINAL. <br />INSTALL NEW CASING & CROWN TO MATCH ORIGINAL. <br />CARD READER ACCESS <br />LOW-ENERGY POWER-OPERATED DOOR. PROVIDE POLE MOUNTED PUSH <br />BOTTONS AT EXTERIOR OF DOOR PER PLAN. <br />TYPE D2 <br />EXTERIOR <br />SINGLE SWING DOOR <br />WOOD PANEL, UPPER LITE <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />DO <br />O <br />R <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />1' <br /> <br />- <br /> <br />5 <br />" <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />U <br />D <br />L <br />E <br />DO <br />O <br />R <br /> <br />H <br />E <br />I <br />G <br />H <br />T <br />1' <br /> <br />- <br /> <br />3 <br />" <br />9" <br />9" <br />1' <br /> <br />- <br /> <br />4 <br />" <br />9"9"9"9" <br />3' <br /> <br />- <br /> <br />5 <br />" <br />6" <br />6" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />6" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />6" <br />NOTE: TYP DIMENSIONS <br />FOR PANEL DOOR <br />TYPES B, C & D <br />LO <br />C <br />A <br />T <br />E <br />D <br /> <br />B <br />E <br />T <br />W <br />E <br />E <br />N <br /> <br />3 <br />4 <br />" <br /> <br />- <br /> <br />4 <br />4 <br />" <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br /> <br />D <br />O <br />O <br />R <br /> <br />H <br />A <br />R <br />D <br />W <br />A <br />R <br />E <br />9"9" <br />9" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />7 <br />" <br />9" <br />6' <br /> <br />- <br /> <br />8 <br />" <br /> <br />M <br />I <br />N <br />. <br />DOOR GENERAL NOTES <br />8 <br />A5.00 <br />HW #1 (LARGE DOUBLE DOORS) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />6 HINGE CUSTOM HEAVY DUTY METAL T HINGE - TBD <br />TO MATCH HISTORIC PHOTO <br />2 PULL PLATE - INSIDE TBD <br />1 DEADBOLT TBD <br />1 SET SEALS TBD <br />1 MEETING STILE SEAL TBD <br />1 KICKPLATE - INSIDE TBD <br />1 CANE BOLTS TBD <br />1 THRESHOLD AS DETAILED <br />NOTE: <br />1. CONTRACTOR TO SUBMIT DOOR HARDWARE THAT IS APPRPRIATE FOR THE SCALE OF THESE DOORS. <br />PROVIDE SHOP DRAWINGS AND HARDWARE SPCIFICATIONS PRIOR TO FABRICATION. <br />2. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD WITH ARCHITECT PRIOR TO INSTALLATION. <br />3. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #2 (MAIN ENTRY DOOR - LOW ENERGY POWER OPERATED) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LOCKSET / PANIC BAR 5575-L06 ELECTRIFIED 613 VON <br />1 POWER OPERATOR 4642 LCN <br />1 ACTUATOR BUTTON HI/LOW POST MOUNTED - TBD <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 DOOR BOTTOM 364LS Z49 AA ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. PROVIDE LOW VOLTAGE AND HARDWARE REQUIRED FOR LOW-ENERGY POWER OPERATOR. HI/LOW <br />PUSH BUTTON OPERATOR POST MOUNTED PER PLAN. <br />2. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD WITH ARCHITECT PRIOR TO INSTALLATION. <br />3. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #3 (EXTERIOR - STAFF) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET ND50 RHO 613 SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 DOOR BOTTOM 364LS Z49 AA ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD WITH ARCHITECT PRIOR TO INSTALLATION. <br />2. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #4 (EXTERIOR EXIT DOOR) PH <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LOCKSET 5575-L06 613 VON <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 DOOR BOTTOM 364LS Z49 AA ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD WITH ARCHITECT PRIOR TO INSTALLATION. <br />2. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />MANUFACTURERS ABBREVIATIONS: <br />ARC = ARCADIA ALUMINUM STOREFRONT DOOR HARDWARE <br />IVE = IVES HINGES & DOOR STOPS <br />LCN = LCN DOOR CLOSER <br />TRI=TRIMCO PUSH/PULL <br />SCH = SCHLAGE LOCK CO. LOCKS, LATCHES AND CYLINDERS <br />ZER = ZERO INTERNATIONAL THRESHOLDS, SET SEALS AND DOOR SWEEPS <br />HARDWARE GROUPS <br />HW #5 (EXTERIOR - STAFF, CARD READER) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET AD-400 RHO 643e SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 DOOR BOTTOM 364LS Z49 AA ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. PROVIDE LOW VOLTAGE TO THIS DOOR FOR CARD READER ACCESS CONTROL. CONFIRM ACCESS <br />CONTROL SYSTEM CONNECTS TO EXISTING ACCESS CONTROL SYSTEM. <br />2. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />3. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #6 (INTERIOR - MULTI-PURPOSE DOUBLE DOOR) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />6 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET ND70 RHO 613 SCH <br />2 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />2 FLOOR STOP FS439 704 IVE <br />2 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 MEETING STILE SEAL 56/156 D ZER <br />2 DOOR SHOE 254 A ZER <br />2 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />2. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #7 (INTERIOR - MULTI-PURPOSE SINGLE DOOR) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET ND70 RHO 613 SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 DOOR SHOE 254 A ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />2. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #8 (PUBLIC RESTROOM) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 PUSH PLATE 8200 613 IVE <br />1 PULL PLATE 8302 613 IVE <br />1 DEADBOLT B561 613 SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />1 THRESHOLD AS DETAILED <br />NOTE: <br />1. COORDINATED MOUNTING HEIGHTS OF PUSH/PULL PLATE AND CYLINDER WITH REQUIRED <br />ACCESSIBILITY MOUNTING HEIGHTS, PROVIDE SHOP DRAWINGS PRIOR TO FABRICATION. <br />2. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />3. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #9 (INTERIOR - STAFF, CARD READER) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET AD-400 RHO 643e SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. PROVIDE LOW VOLTAGE TO THIS DOOR FOR CARD READER ACCESS CONTROL. CONFIRM ACCESS <br />CONTROL SYSTEM CONNECTS TO EXISTING ACCESS CONTROL SYSTEM. <br />2. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />3. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />HW #10 (JANITOR) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET ND80 RHO 613 SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />NOTE: <br />1. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />2. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />HW #11 (STAFF RESTROOM) <br />QTY DESCRIPTION CATALOG NUMBER FINISH MFR <br />3 HINGE 5BB1 640 IVE <br />1 LEVER LOCKSET ND40 RHO W/ INDICATOR 613 SCH <br />1 CLOSER 4110-3049EDA-72MC, DEL, AVB 616 LCN <br />1 FLOOR STOP FS439 704 IVE <br />1 SET SEALS 488-S x 3M x MITRED TBD ZER <br />1 KICKPLATE 8400 12" X FULL DOOR B-CS 613 IVE <br />1 THRESHOLD AS DETAILED <br />NOTE: <br />1. COORDINATE LOCATION OF FLOOR STOP IN THE FIELD W ITH ARCHITECT PRIOR TO INSTALLATION. <br />2. COORDINATE KEYING WITH BUILDING OWNERS' MASTER KEY SYSTEM. <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />3/8" = 1'-0" <br />4/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />9 <br />: <br />2 <br />2 <br />: <br />3 <br />2 <br /> <br />P <br />M <br />A6.00 <br />DOOR & WINDOW <br />SCHEDULE <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />DOOR SCHEDULE <br />DO <br />O <br />R <br /> <br /># <br />LOCATION <br />SCOPE / PHASE TY <br />P <br />E <br />DOOR MEASUREMENTS <br />HA <br />R <br />D <br />W <br />A <br />R <br />E <br /> <br />G <br />R <br />O <br />U <br />P <br />PA <br />N <br />I <br />C <br /> <br />H <br />A <br />R <br />D <br />W <br />A <br />R <br />E <br />DOOR FRAME DETAIL <br />REMARKSRO <br />O <br />M <br /> <br /># <br />NAME WI <br />D <br />T <br />H <br />HE <br />I <br />G <br />H <br />T <br />TH <br />I <br />C <br />K <br />N <br />E <br />S <br />S <br />MATERIAL FRAME GL <br />A <br />Z <br />I <br />N <br />G <br />MATERIAL FINISH HE <br />A <br />D <br />JA <br />M <br />B <br />TH <br />R <br />E <br />S <br />H <br />O <br />L <br />D <br />01 02 MULTI-PURPOSE ROOM A (N) EXTERIOR DOOR / (E) <br />OPENING <br />F 10' - 6" 10' - 6" 2" WD PT GL-1 WD PT 13C/A5.06 CUSTOM DOOR TO MATCH HISTORIC. TRUE DIVIDED LITES. DECORATIVE IRON BARN DOOR <br />HINGES. REFER TO REMARK # 4,6 <br />02 02 MULTI-PURPOSE ROOM A (N) EXTERIOR DOOR / (E) <br />OPENING <br />F 10' - 6" 10' - 6" 2" WD PT GL-1 WD PT 13C/A5.06 CUSTOM DOOR TO MATCH HISTORIC. TRUE DIVIDED LITES. DECORATIVE IRON BARN DOOR <br />HINGES. REFER TO REMARK # 4,6 <br />03 01 ENTRY / CHECK IN OFFICE (N) EXTERIOR DOOR / (E) <br />OPENING <br />E 3' - 6" 6' - 8" 1 3/4" YES WD PT - WD PT 13D/A5.06 CUSTOM WOOD PANEL + GLASS DOOR TO MATCH HISTORIC. REPAIR CONCRETE <br />THRESHOLD. REFER TO REMARK # 13 <br />04 01 ENTRY / CHECK IN OFFICE (N) EXTERIOR DOOR / (E) <br />OPENING <br />D1 3' - 0" 6' - 8" 1 3/4" WD PT GL-1 WD PT 13D/A5.06 CUSTOM WOOD PANEL + 3 OVER 3 TRUE DIVIDED LITE GLASS DOOR TO MATCH HISTORIC. <br />OVERHEAD OPERABLE TRANSOM. REPAIR CONCRETE THRESHOLD. <br />05 04 HALLWAY (N) EXTERIOR DOOR / (E) <br />OPENING <br />D1 3' - 0" 6' - 8" 1 3/4" YES WD PT GL-1 WD PT 13C/A5.06 CUSTOM WOOD PANEL + 3 OVER 3 TRUE DIVIDED LITE GLASS DOOR TO MATCH HISTORIC. <br />OVERHEAD OPERABLE TRANSOM. REPAIR CONCRETE THRESHOLD. <br />06 05 TRAINING ROOM C DEMO & INFILL - 3' - 0" 6' - 8" 1" - -- - - - - - OPENING NOT ORIGINAL TO BUILDING <br />07 10 OFFICE AND BREAKROOM (N) EXTERIOR DOOR / (E) <br />OPENING <br />D2 3' - 0" 6' - 8" 1 3/4" WD PT GL-1 WD PT 13C/A5.06 CUSTOM WOOD PANEL + 3 OVER 3 TRUE DIVIDED LITE GLASS DOOR TO MATCH HISTORIC. <br />OVERHEAD OPERABLE TRANSOM. DEMO (E) CONCRETE THRESHOLD. REFER TO REMARK <br />#12. <br />08 11 RESTROOM REMOVE & SALVAGE - 3' - 0" 6' - 8" 1 3/4" - -- - - - - - INFILL, REFER TO WINDOW SCHEDULE <br />09 07 WOMENS REMOVE & SALVAGE - 3' - 0" 6' - 8" 1 3/4" - - - -- - - - INFILL, REFER TO WINDOW SCHEDULE <br />11 01 ENTRY / CHECK IN OFFICE NEW - INTERIOR A2 4' - 0" 0" - - - - - 13A/A5.06 ARCHED OPENING, REFER TO INTERIOR ELEVATIONS <br />12 03 TRAINING ROOM B NEW - INTERIOR C1 6' - 0" 6' - 8" 1 3/4" WD PT GL-1 WD PT 10/A5.06 9/A5.06 13A/A5.06 REFER TO REMARKS #11 <br />13 04 HALLWAY NEW - INTERIOR A2 4' - 0" 6' - 8" - - - WD PT - - 13A/A5.06 <br />14 05 TRAINING ROOM C NEW - INTERIOR B2 3' - 0" 6' - 8" 1 3/4" WD PT GL-1 WD PT 10/A5.06 9/A5.06 13A/A5.06 REFER TO REMARKS #11 <br />15 06 HALLWAY NEW - INTERIOR A2 4' - 6" 6' - 8" - - - WD PT - - 13A/A5.06 <br />16 07 WOMENS NEW - INTERIOR B1 3' - 0" 6' - 8" 1 3/4" WD PT -WD PT 10/A5.06 9/A5.06 13B/A5.06 REFER TO REMARKS #11 <br />17 09 MENS NEW - INTERIOR B1 3' - 0" 6' - 8" 1 3/4" WD PT - WD PT 10/A5.06 9/A5.06 13B/A5.06 REFER TO REMARKS #11 <br />18 10 OFFICE AND BREAKROOM NEW - INTERIOR B3 3' - 0" 6' - 8" 1 3/4" WD PT GL-1 WD PT 10/A5.06 9/A5.06 13A/A5.06 REFER TO REMARKS #11, 12 <br />19 10 OFFICE AND BREAKROOM NEW - INTERIOR A1 3' - 0" 6' - 8" - - - - - 13A/A5.06 <br />20 12 JANITOR NEW - INTERIOR B1 3' - 0" 6' - 8" 1 3/4" WD PT - WD PT 10/A5.06 9/A5.06 13A/A5.06 REFER TO REMARKS #11 <br />21 11 RESTROOM NEW - INTERIOR B1 2' - 10" 6' - 8" 1 3/4" WD PT - WD PT 10/A5.06 9/A5.06 13B/A5.06 REFER TO REMARKS #11 <br />DOOR TYPES <br />ARCHED <br />N/A <br />- <br />- <br />- <br />- <br />ARCHED <br />ARCHED <br />No. Description Date <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025 <br />NOTE: WINDOW SCHEDULE MOVED TO SHEET A6.02