REF. <br />GENERAL NOTES <br />1. FURNITURE ON ALL PLANS ARE SHOWN STRICTLY FOR DESIGN CONCEPT. COORDINATE FINAL <br />FURNITURE SELECTIONS AND SPECIFICATIONS WITH FURNITURE VENDORS. <br />2. PER CBC 1010.1.10, DOORS SERVING ROOMS OR SPACES WITH AN OCCUPANT LOAD OF 50 OR <br />MORE ARE REQUIRED TO HAVE PANIC HARDWARE OR FIRE EXIT HARDWARE. <br />3. ROOM OCCUPANT LOAD FACTORS PER CBC 1004, TABLE 1004.1.2. <br />4. REFER TO FOR ALL DOOR MANEUVERING CLEARANCE REQUIREMENTS AND A5.06 FOR <br />THE DOOR SCHEDULE. <br />5. REFER TO CIVIL DRAWINGS FOR ALL GRADING INFORMATION. <br />6. REFER TO A0.00 SITE PLAN FOR GATE INFORMATION. <br />7. 114 TOTAL BUILDING OCCUPANTS < 300 OCCUPANTS, THEREFORE HIGHER RISK CATEGORY IS <br />NOT REQUIRED. <br />SIGNAGE SCHEDULE LEGENDS <br />Room name <br />150 SF <br />100 GROSS <br />10 <br />101 ROOM NUMBER <br />AREA <br />OCCUPANT LOAD FACTOR; GROSS LOAD FACTOR U.N.O.; <br />AU = AUXILIARY USE <br />OCCUPANT LOAD <br />NUMBER & DIRECTION OF OCCUPANTS USING EGRESS <br />NUMBER & DIRECTION OF COMBINED OCCUPANTS USING EGRESS <br />COMMON PATH OF EGRESS TRAVEL DISTANCE -THE MAXIMUM LENGTH OF <br />EXIT ACCESS TRAVEL, MEASURED FROM THE MOST REMOTE POINT WITHIN A <br />STORY TO THE ENTRANCE TO AN EXIT ALONG THE NATURAL AND <br />UNOBSTRUCTED PATH OF EGRESS TRAVEL. <br />EXIT ROUTES -EXIT ROUTES FROM INDIVIDUAL HABITABLE SPACES TO THE <br />NEAREST EXIT ACCESS. <br />RECESSED FIRE EXTINGUISHER <br />REFER TO FOR MOUNTING HEIGHT <br />01 TACTILE EXIT SIGNAGE SHALL BE REQUIRED AT THE FOLLOWING LOCATIONS PER CBC 1013.4: <br />• EACH GRADE LEVEL EXTERIOR EXIT DOOR THAT IS REQUIRED TO COMPLY WITH <br />SECTION 1013.1 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORD "EXIT" <br />• EACH EXIT DOOR THAT IS REQUIRED TO COMPLY WITH CBC 1013.1 THAT LEADS <br />DIRECTLY TO A GRADE-LEVEL EXTERIOR EXIT BY MEANS OF AN EXIT ENCLOSURE THAT <br />DOES NOT UTILIZE A STAIR OR RAMP OR BY MEANS OF AN EXIT PASSAGEWAY, SHALL <br />BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE" <br />• EACH EXIT ACCESS DOOR FROM AN INTERIOR ROOM OR AREA TO A CORRIDOR OR <br />HALLWAY THIS IS REQUIRED TO COMPLY WITH CBC 1013.1 SHALL BE IDENTIFIED BY A <br />TACTILE EXIT SIGN WITH THE WORDS "EXIT ROUTE" <br />• EACH EXIT DOOR THROUGH A HORIZONTAL EXIT THAT IS REQUIRED TO COMPLY WITH <br />CBC 1013.1 SHALL BE IDENTIFIED BY A TACTILE EXIT SIGN WITH THE WORDS "TO EXIT" <br />• REFER TO DETAIL <br />02 MAXIMUM OCCUPANCY SIGN, REFER TO DETAIL <br />FEC <br />CEILING SUSPENDED OR WALL MOUNTED (REFER TO RCP) ILLUMINATED EXIT <br />SIGN (WITH DIRECTIONAL ARROWS AS INDICATED). EXIT SIGNS SHALL BE <br />ILLUMINATED AT ALL TIMES FOR A DURATION OF NOT LESS THAN 90 MINUTES <br />IN CASE OF PRIMARY POWER LOSS. TO ENSURE THIS CONTINUOUS <br />ILLUMINATION, THE EXIT SIGN MUST BE CONNECTED TO AN EMERGENCY <br />POWER SYSTEM PROVIDED FROM STORAGE BATTERIES, UNIT EQUIPMENT OR <br />AN ON-SITE GENERATOR, CBC 1013.6.3. <br />ALL SIGNAGE TO BE MOUNTED PER DETAIL <br />FOR ALL SIGNAGE REQUIREMENTS & SPECIFICATIONS REFER TO DETAIL <br />03 TOILET IDENTIFICATION SIGN, REFER TO DETAIL <br />04 TOILET DOOR SIGN, REFER TO DETAIL <br />20 <br />A5.03 <br />ACCESSIBLE PATH OF TRAVEL <br />PATH OF TRAVEL (P.O.T.) AS INDICATED IS A BARRIER FREE ACCESS ROUTE <br />WITHOUT ANY ABRUPT VERTICAL CHANGES EXCEEDING 1/2" BEVELED AT 1:2 <br />MAXIMUM SLOPE, EXCEPT THAT LEVEL CHANGES DO NOT EXCEED 1/4" VERTICAL <br />AND IS AT LEAST 48" WIDE, UNLESS NOTED OTHERWISE. SURFACE IS SLIP <br />RESISTANT, STABLE, FIRM AND SMOOTH. CROSS-SLOPE DOES NOT EXCEED 2% <br />AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5% UNLESS OTHERWISE <br />INDICTED. (POT) SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS <br />TO 80" MINIMUM AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION <br />FROM WALL AND ABOVE 27" AND LESS THAN 80". ARCHITECT TO VERIFY THAT <br />ALL BARRIERS IN THE PATH OF TRAVEL HAVE BEEN REMOVED OR WILL BE <br />REMOVED UNDER THIS PROJECT, AND PATH OF TRAVEL COMPLIES WITH CBC <br />11B-303 & 11B-304. <br />WALKS, SIDEWALKS, AND PEDESTRIAN WAYS SHALL BE FREE OF GRATINGS <br />WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF <br />THESE AREAS, GRID OPENINGS IN GRATINGS SHALL BE LIMITED TO 1/2" IN THE <br />DIRECTION OF TRAFFIC FLOW. IF GRATINGS HAVE ELONGATED OPENINGS, <br />THEY SHALL BE PLACED SO THAT THE LONG DIMENSION IS PERPENDICULAR <br />TO THE DOMINANT DIRECTION OF TRAVEL (CBC 11B-302.3) <br />19 <br />A5.00 <br />1-HOUR RATED WALL <br />-EXTERIOR WALLS ALONG GRIDS 1 AND 3 ARE TO BE 1-HOUR FIRE- <br />RESISTANCE RATED DUE TO FIRE SEPARATION DISTANCE <br />-EXTERIOR OPENINGS ARE TO BE PROTECTED BY AN EXTERIOR <br />FIRE SPRINKLER SYSTEM PER CHBC 8-402.1 (DEFERRED <br />SUBMITTAL) <br />EXISTING WOOD STUD WALL TO REMAIN <br />-NEW GYP BD SHEATHING ON INTERIOR SIDE(S) OF ALL (E) WALLS, TYP. <br />-ALL EXTERIOR WALLS TO RECEIVE R-19 BATT INSULATION <br />2x WOOD STUDS @ 16" O.C., MATCH ADJACENT WALL ASSEMBLY <br />17 <br />A5.00 <br />14 <br />A5.00 <br />10 <br />A5.00 <br />15 <br />A5.00 <br />11 <br />A5.00 <br />11 <br />A5.00 <br />PLUMBING FIXTURE REQUIREMENTS <br />NO EXISTING PLUMBING FIXUTRES REMAIN ON SITE, ALL FIXTURES ARE NEW. <br />/2 A5.00 <br />1006 SF <br />MULTI-PURPOSE ROOM <br />A <br />7 NET <br />144 <br />02 <br />212 SF <br />ENTRY / CHECK IN <br />OFFICE <br />150 <br />2 <br />01 348 SF <br />TRAINING ROOM B <br />15 NET <br />18 <br />03 <br />375 SF <br />TRAINING ROOM C <br />15 NET <br />25 <br />05 <br />162 SF <br />WOMENS <br />AU <br />- <br />07 <br />139 SF <br />MENS <br />AU <br />- <br />09 <br />273 SF <br />OFFICE AND <br />BREAKROOM <br />15 <br />18 <br />10 <br />56 SF <br />RESTROOM <br />AU <br />- <br />11 <br />15 SF <br />JANITOR <br />AU <br />- <br />12 <br />01 <br />01 01 <br />01 <br />0304 03 04 <br />03 <br />04 <br />FEC <br />EMPLOYEE <br />ONLY GATE <br />97 <br />18 <br />25 <br />18 <br />260 SF NET <br />90 <br />2 <br />144 <br />9292 <br />97 <br />PATH OF TRAVEL TO <br />PUBLIC RIGHT OF WAY <br />EXIT WIDTH <br />= 97 X .2 = 19.4" REQUIRED WIDTH <br />36" PROVIDED > 19.4" REQ'D <br />EXIT WIDTH <br />= 92 X .2 <br />= 18.4" REQUIRED WIDTH <br />36" PROVIDED > 18.4" REQ'D <br />30' - 11" <br />OF AREA PER CBC 1007.1.1 <br />48' - 0" MAXIMUM OVERALL DIAGONAL DIMENSION <br />2 EXITS SEPARATED BY ONE-HALF OF THE MAXIMUM OVERALL DIAGONAL DIMENSION <br />(48'/2) 24' < 30'-11" <br />1005 SF NET <br />7272 <br />02 <br />MIN. <br />3' - 0" <br />WALKWAY DIMENSIONS MATCH THE <br />HISTORIC & (E) LAYOUT. <br />WALKS CAN BE REDUCED FROM 48" <br />MIN. TO 36" WHEN EXISTING <br />CONDITIONS CREATE <br />UNREASONABLE HARDSHIPS, PER <br />CBC 11B-403.5.1 EXCEPTION 3. <br />STRICT COMPLIANCE WITH THE 48" <br />MIN REQUIREMENT WOULD <br />DESTROY THE HISTORICAL <br />SIGNIFICANCE OF THE PROPERTY <br />(CHBC 8-602.1). <br />EMPLOYEE <br />ONLY GATE <br />FRONT SETBACK <br />(E) 24' - 7" <br />SIDE SETBACK <br />(E <br />) <br /> <br />4 <br />' <br /> <br />- <br /> <br />1 <br />0 <br />" <br />SI <br />D <br />E <br /> <br />S <br />E <br />TB <br />A <br />C <br />K <br />(E <br />) <br /> <br />5 <br />' <br /> <br />- <br /> <br />3 <br />" <br />SI <br />D <br />E <br /> <br />S <br />E <br />TB <br />A <br />C <br />K <br />(E <br />) <br /> <br />3 <br />' <br /> <br />- <br /> <br />1 <br />1 <br />" <br />SI <br />D <br />E <br /> <br />S <br />E <br />TB <br />A <br />C <br />K <br />(E <br />) <br /> <br />3 <br />' <br /> <br />- <br /> <br />0 <br />" <br />BACK SETBACK <br />(E) 34' - 2" <br />(E) RESIDENCE <br />(E) RESIDENCE <br />(E) RESIDENCE <br />24" <br />60 <br />" <br /> <br />C <br />L <br />R <br />. <br />4' <br /> <br />- <br /> <br />0 <br />" <br />ACCESSIBLE DOOR ACTUATOR <br />PER CHBC 8-603.4, POWER- <br />ASSISTED DOOR MAY BE <br />CONSIDERED EQUIVALENT <br />ALTERNATIVE TO STRIKESIDE <br />CLEARANCE. <br />30" x 48" CLR <br />FLR SPACE <br />CARD READER <br />ACCESS ONLY <br />01 <br />HALLWAY <br />06 <br />HALLWAY <br />04 <br />PATH OF TRAVEL <br />TO PUBLIC WAY <br />270 NET <br />DOOR HAS LATCH <br />AND NO CLOSER <br />PROVIDE MANEUVERING <br />SPACE AT GATE, 2.083% <br />MAX SLOPE IN ANY <br />DIRECTION <br />4' 0' 4' 8'12' <br />Scale <br />Project number <br />Date <br />Drawn by <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />JD/AP <br />As indicated <br />4/ <br />2 <br />8 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />1 <br />: <br />1 <br />4 <br />: <br />2 <br />8 <br /> <br />A <br />M <br />T2.00 <br />EGRESS PLAN <br />23004 <br />CYPRESS CENTER <br />RESTORATION <br />CITY OF SANTA ANA <br />1/17/2025 <br />625 S. CYPRESS AVE. <br />SANTA ANA, CA 92701 <br />3/16" = 1'-0"T2.00 <br />1 EGRESS PLAN <br />No. Description Date <br />75% CD 3/15/2024 <br />90% CD 5/14/2024 <br />PERMIT SET 5/17/2024 <br />OCFA SUBMITTAL 9/26/2024 <br />BACKCHECK SET 1/17/2024 <br />BACKCHECK SET_V2 4/8/2025