Laserfiche WebLink
E0.00 <br />Scale <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />No.Description Date <br />AS NOTED <br />Engineering Corp <br />Mechanical Electrical Plumbing <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA 92614 <br />TEL: 949.516.6480 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />LEC T R ICAL <br />EXP: 3-31-27 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />No. E21819 <br />E <br /> <br />ALI S A FAIAN <br />90% CD 5/02/2024 <br />CYPRESS STREET <br />FIRE STATION <br />REHABILITATION <br />CITY OF SANTA ANA <br />625 S. CYPRESS <br />SANTA ANA, CA <br />Project number <br />Date <br />Drawn by TP/HH <br />23004 <br />1/15/2025 <br />PERMIT SET 5/17/2024 <br />BACK CHECK SET 1/15/2025 <br />BACK CHECK SET_V2 4/08/2025 <br />GENERAL NOTES, <br />ABBREVIATIONS <br />AND SYMBOLS <br />UON UNLESS OTHERWISE NOTED <br />XFMR <br />WP <br />VL <br />WEATHERPROOF <br />TRANSFORMER <br />WATTS <br />VERIFY LOCATION <br />VOLTAGE <br />UL <br />U/G <br />TYP <br />TVSS <br />TS <br />TBB <br />SIM <br />SWB <br />SW <br />R <br />SCA <br />RGC <br />UNDER GROUND <br />UNDERWRITER'S LABORATORIES <br />TYPICAL <br />TELEPHONE BACKBOARD <br />TIME SWITCH <br />SIMILAR <br />SWITCHBOARD <br />SWITCH <br />EXISTING, TO BE REMOVED <br />RIGID GALVANIZED CONDUIT <br />SHORT CIRCUIT AMPERE <br />P <br />PL <br />PNL <br />(NR) <br />NIC <br />NL <br />NTS <br />N <br />MIN <br />NA <br />POLE <br />PROPERTY LINE <br />PANEL <br />NOT IN CONTRACT <br />NIGHT LIGHT <br />NOT TO SCALE <br />NOT APPLICABLE <br />NEW <br />MINIMUM <br />EWH ELECTRIC WATER HEATER <br />MC <br />MAX <br />MFR <br />IG <br />LTG <br />LTA <br />GND <br />IC <br />HP <br />GFCI <br />F <br />MECHANICAL CONTRACTOR <br />MANUFACTURERS <br />MAXIMUM <br />ISOLATED GROUND <br />LET-THRU AMPS FOR FUSES <br />LIGHTING <br />GROUND <br />HORSEPOWER <br />FUSE <br />EQ <br />EQP <br />(ER) <br />EA <br />EC <br />CO <br />(E) <br />(D) <br />CONN <br />CLG <br />CL <br />EXISTING, TO REMAIN <br />EQUIVALENT <br />EQUIPMENT <br />ELECTRICAL CONTRACTOR <br />EACH <br />CONDUIT ONLY <br />DEMOLISH <br />CONNECTED <br />CEILING <br />CENTER LINE <br />ABBREVIATIONS <br />CB <br />CKT <br />CATV <br />C <br />BR <br />BCW <br />AIC <br />AFF <br />A <br />COMMUNITY ANTENNA TELEVISION <br />CIRCUIT BREAKER <br />CIRCUIT <br />BARE COPPER WIRE <br />CONDUIT <br />BRANCH <br />AMPS INTERRUPTING CAPACITY <br />ABOVE FINISHED FLOOR <br />AMPERE <br />NEW FIRE STATION RENOVATION IN EXISTING CONSTRUCTION. ADDING NEW 400A, 120/240V, 1-PHASE, <br />3-WIRE SERVICE (NEW SCE METER). PROVIDE POWER (GENERAL AND MECHANICAL), LIGHTING AND <br />LIGHTING CONTROL. <br />SCOPE OF WORK: <br />-2022 CALIFORNIA ELECTRICAL CODE. <br />-2022CALIFORNIA MECHANICAL CODE. <br />-2022 CALIFORNIA ENERGY CODE. <br />-2022 CALIFORNIA FIRE CODE. <br />-2022 CALIFORNIA PLUMBING CODE. <br />-NFPA 99 STANDARDS APPLICABLE TO PROJECT. <br />-CITY OF SANTA ANA AMENDMENTS <br />EXISTING, TO BE <br />RELOCATED AS <br />SHOWN <br />GROUND FAULT <br />CIRCUIT INTERRUPTER <br />INTERRUPTING <br />CAPACITY (RMS SYM.) <br />APPLICABLE CODES: <br />INDICATES NEW LOCATION OF <br />RELOCATED DEVICE. PROVIDE <br />ADDITIONAL CONDUITS, WIRES, <br />BOXES, ETC. TO RE-ESTABLISH <br />CIRCUITRY AS BEFORE. <br />TRANSIENT VOLTAGE <br />SURGE SUPPRESSOR <br />OPEN STRIP FLUCRESCENT <br />EMERGENCY LIGHT FIXTURE WITH BATTERY PACK <br />FLUORESCENT LIGHT FIXTURE AS SPECIFIED <br />WALL WASHER LIGHT FIXTURE, ARROW DENOTES AIMING DIRECTION <br />JUNCTION BOX, SIZE AS NOTED AND PER CODE. <br />JUNCTION BOX WITH FLEXIBLE CONDUIT CONNECTED TO DEVICE OR EQUIPMENT. <br />DISCONNECT SWITCH, 30A, 3-POLE, NON-FUSED <br />WITH 1-1/4" C.O. AND PULL ROPE STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. <br />CONDUIT TURNING UP <br />CONDUIT TURNING DOWN <br />DISCONNECT SWITCH, 60A, W/45A FUSE, 3-POLE (UON) <br />HOMERUN TO PANEL A CIRCUITS 1&3 <br />CONDUIT EXPOSED <br />CONDUIT CONCEALED IN FLOOR SLAB OR UNDERGROUND <br />GROUND, PER CODE AND AS SPECIFIED <br />UTILITY METERING <br />CIRCUIT BREAKER, 150A, 3-POLE <br />TELEPHONE CONDUIT/HOMERUN, SIZE AS NOTED <br />SWITCH & FUSE, 100AS, 75 AF, TYPE AS NOTED, 3-POLE (UON) <br />SWITCHBOARD <br />LIGHT FIXTURE TYPE F1, 40W EACH, TYPICAL IN A ROOM OR AREA <br />FLUSH MOUNTED PANEL BOARD, B INDICATES NAME <br />SURFACE MOUNTED PANEL BOARD, A INDICATES NAME <br />REFERENCE NOTE #1 <br />REFERENCE TO DETAIL #2 ON SHEET E2.0 <br />OUTLET FOR TELEPHONE/DATA ONLY @+18" (UON) PROVIDE A 5S J-BOX WITH MUD RING AND <br />FLUSH MOUNTED DUPLEX RECEPTACLE OUTLET 250V 2P, 3W, 20A (NEMA 6-20R) <br />SYMBOLS <br />WALLFLOOR CEILING <br />DM a <br />OUTLET FOR WAP <br />HOMERUN TO PANEL A CIRCUITS 1&3 WITH GRAND WIRE <br />EXIT SIGN, SINGLE FACE, ARROW IF INDICATED DENOTES DIRECTION <br />SINGLE POLE TOGGLE SWITCH @+48"(UON), SUBSCRIPTS INDICATE THE FOLLOWING: <br />A - OUTLET 'A' CONTROLLED <br />DM - DIMMER, <br />RATING AS NOTED <br />M - MANUAL MOTOR STARTER <br />P - PILOT ON LIGHT <br />PULL ROPE STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. <br />OUTLET FOR DATA ONLY @+18" (UON) PROVIDE A J-BOX WITH 1-1/4" C.O. AND <br />OUTLET FOR TELEPHONE ONLY @+18" (UON) PROVIDE A J-BOX WITH 1-1/4" C.O. AND <br />PULL ROPE STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. <br />OUTLET FOR DATA ONLY PROVIDE A J-BOX, NUMBER INDICATES QUANTITY <br />OF THE JACKS IN THE SAME DATA OUTLET <br />REPRESENTS WITH SINGLE SWITCH; a,b REPRESENTS WITH DUAL SWITCHES <br />COMBINATION OF MOTOR STARTER AND CIRCUIT BREAKER, NEMA SIZE '1' (UON) <br />CONDUIT CONCEALED IN CEILING OR WALL, 3/4" CONDUIT, 2#12 WIRES (UON) <br />1 <br />2 <br />E2.0 <br />OS <br />1.INFORMATION GIVEN ON THE DRAWINGS REGARDING EXISTING INSTALLATION HAS BEEN OBTAINED <br />FROM THE BEST SOURCES AVAILABLE. HOWEVER IT CANNOT BE GUARANTEED IN ALL RESPECTS. <br />VERIFY ALL SUCH INFORMATION BEFORE PROCEEDING WITH THE NEW WORK THAT MAY BE AFFECTED <br />UPON. INCLUDE AS A PART OF THE CONTRACT ALL WORK THAT ARE REQUIRED TO PRODUCE <br />INDICATED RESULT BEFORE SUBMITTING THE BID PROPOSAL. <br />2.THE SCOPE OF WORK SHALL INCLUDE THE FURNISHING OF ALL MATERIALS, EQUIPMENT, SUPPLIES AND <br />LABOR AND THE PERFORMANCE OF ALL OPERATIONS NECESSARY FOR THE INSTALLATION OF ALL <br />ELECTRICAL WORK, COMPLETE AND IN OPERATING CONDITION, ALL TO THE SATISFACTION OF <br />UNIVERSITY'S REPRESENTATIVE. THE ENTIRE INSTALLATION SHALL BE READY IN EVERY RESPECT FOR <br />SATISFACTORY AND EFFICIENT OPERATION WHEN COMPLETED. <br />3.PROVIDE ALL MATERIALS AND EQUIPMENT TO MAKE FINAL CONNECTIONS TO ALL EQUIPMENT AND <br />APPLIANCES. <br />4.NOTHING DESCRIBED HEREIN OR INDICATED ON THE DRAWINGS SHALL BE CONSTRUED TO PERMIT <br />WORK NOT CONFORMING TO THE MOST STRINGENT OF THE APPLICABLE CODES AND REGULATIONS. <br />5.ALL WORK SHALL BE DONE IN FULL COMPLIANCE WITH THE CALIFORNIA ELECTRICAL CODE, 2022 <br />EDITION AND 2022 CALIFORNIA TITLE-24 ENERGY STANDARDS AND IN ACCORDANCE WITH THE <br />REQUIREMENTS OF THE LOCAL AUTHORITIES HAVING JURISDICTION. <br />6.ALL EQUIPMENT AND MATERIALS SHALL BE NEW AND SHALL BE LISTED BY THE UNDERWRITER'S <br />LABORATORIES, MANUFACTURED IN FULL COMPLIANCE WITH ASME, ANSI, IEEE AND NEMA. <br />7.ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. SIZES, LOCATION OF EQUIPMENT, AND WIRING ARE <br />SHOWN TO SCALE WHERE POSSIBLE, BUT MAY BE DISTORTED FOR CLARITY. FINAL LOCATIONS OF <br />OUTLETS AND EQUIPMENT SHALL BE ADJUSTED AS DICTATED BY EXISTING CONDITIONS. IT IS NOT <br />WITHIN THE SCOPE OF DRAWINGS TO SHOW ALL NECESSARY BENDS, OFFSETS, AND PULLBOXES. IT <br />SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL HIS WORK TO CONFORM TO THE <br />STRUCTURE. CONDUIT RUNS ARE INDICATED DIAGRAMMATICALLY, DETERMINE EXACT LOCATION IN THE <br />FIELD. <br />8.DURING THE PROGRESS OF THE WORK, MAKE A CAREFUL RECORD OF ALL CHANGES BY WHICH THE <br />ACTUAL INSTALLATION DIFFERS FROM THAT INDICATED ON THE CONTRACT DRAWINGS AND <br />DOCUMENTS. <br />9.ANY ERROR, OMISSION OR DESIGN DISCREPANCY ON THE CONSTRUCTION DOCUMENTS SHALL BE <br />BROUGHT TO THE ATTENTION OF UNIVERSITY'S REPRESENTATIVE FOR CLARIFICATION OR CORRECTION <br />PRIOR TO INSTALLATION. <br />10.THE WORD "VERIFY LOCATION" ABBREVIATED AS "V.L." SHALL MEAN TO COORDINATE THE EXACT <br />LOCATION OF THE DEVICE AND/OR EQUIPMENT BEING REFERRED TO WITH UNIVERSITY'S <br />REPRESENTATIVE AND TO PROVIDE NECESSARY ADJUSTMENT WITHOUT ANY EXTRA COST TO THE <br />UNIVERSITY. <br />11.CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP, EQUIPMENT AND MATERIALS FOR A PERIOD OF <br />NOT LESS THAN ONE(1) YEAR FOR THE UNIVERSITY. SHOULD ANY DEFECTS OCCUR DURING THIS <br />PERIOD, THE CONTRACTOR SHALL PROMPTLY REPAIR OR REPLACE THE DEFECTIVE ITEMS AT NO <br />ADDITIONAL COSTS TO THE UNIVERSITY, INCLUDING COST OF LABOR AND MATERIALS. <br />12.ARCHITECTURAL SPECIFICATIONS, GENERAL, SPECIAL AND SUPPLEMENTAL CONDITIONS SHALL FORM A <br />PART OF THIS CONSTRUCTION DOCUMENT. <br />13.UPON COMPLETION OF THE WORK, CONDUCT AN OPERATING TEST AND DEMONSTRATE TO THE <br />UNIVERSITY'S REPRESENTATIVE THAT ALL EQUIPMENT ARE OPERATING IN A SATISFACTORY MANNER <br />AND IN ACCORDANCE TO THE REQUIREMENTS OF DRAWINGS. <br />14.USE ELECTRICAL METALLIC TUBING FOR TRADE SIZES OF 3/4 TO 2 INCHES INCLUSIVE IN DRY <br />LOCATIONS, USE RIGID METALLIC CONDUIT IN EXTERIOR INSTALLATION. USE RIGID METALLIC CONDUIT <br />FOR ANY FEEDERS. <br />15.USE FLEXIBLE STEEL CONDUITS FOR SHORT CONNECTIONS TO MOTORS AND IN DRY LOCATIONS I.E. <br />ABOVE ACCESSIBLE CEILING FOR LIGHTING AND CONVENIENT OUTLETS BRANCH CIRCUITING, AND IN <br />STUD WALLS WHERE ALLOWED BY THE LOCAL CODE. USE LIQUID TIGHT FLEXIBLE CONDUITS IN AREAS <br />EXPOSED TO WEATHER. PROVIDE INTEGRAL GROUNDING CONDUCTOR FOR LENGTHS EXCEEDING 6 <br />FEET. FLEXIBLE CONDUITS FOR CONNECTION TO THE ROOF TOP AIR CONDITIONERS SHALL BE <br />PROVIDED WITH INTEGRAL GROUND WIRE REGARDLESS OF THE LENGTH. <br />16.OUTLET AND JUNCTION BOXES SHALL BE GALVANIZED PRESSED STEEL WITH PLUGGED HOLES. ALL <br />BOXES SHALL BE OF CEC CODE SIZE FOR THE NUMBER OF WIRES OR CONDUITS PASSING THROUGH OR <br />TERMINATING THEREIN BUT IN NO CASE SHALL ANY BOX BE LESS THAN 4 INCHES SQUARE BY 2-1/8 <br />INCHES DEEP. NO PLASTIC BOXES SHALL BE ALLOWED. <br />17.SINGLE CONDUCTOR COPPER WIRE WITH 600 VOLTS INSULATION SHALL BE USED FOR GENERAL WIRING <br />IN CONDUIT UNLESS OTHERWISE SHOWN. ALL CONTACTS, GROUNDING AND NEUTRAL BUS BARS SHALL <br />BE COPPER. <br />18.CONDUCTORS 8-AWG AND LARGER SHALL BE STRANDED TYPE. CONDUCTORS 10-AWG AND SMALLER <br />SHALL BE SOLID WITH COLOR CODED INSULATION. <br />19.PROVIDE CONDUCTORS TYPE THW OR THWN FOR DRY AND WET LOCATIONS AND THHN FOR DRY <br />LOCATIONS ONLY. <br />20.MINIMUM SIZE CONDUCTOR FOR USE IN LIGHTING AND POWER BRANCH CIRCUITS SHALL BE 12-AWG. <br />21.NO WIRE AMPACITY REDUCTION SHALL BE ALLOWED ON THE FEEDERS AND BRANCH CIRCUIT WIRING <br />INCLUDING NEUTRALS UNLESS APPROVED BY THE UNIVERSITY'S REPRESENTATIVE. <br />22.LABEL ALL CONDUIT, JUNCTION BOXES, PANELS AND TRANSFORMERS WITH THE VOLTAGE AND CIRCUIT <br />NUMBER(S). <br />23.ENGRAVE ALL SWITCHES AND OUTLETS WITH PANEL AND CIRCUIT NUMBER. <br />24.WIRES AND CONDUITS SIZES INDICATED THROUGHOUT THE DRAWINGS ARE BASED ON COPPER <br />CONDUCTORS. <br />25.MINIMUM SIZE OF CONDUIT FOR POWER, LIGHTING, AND MECHANICAL EQUIPMENT SHALL BE 3/4" (UON). <br />26.SHOP DRAWING SUBMITTALS ARE REQUIRED FOR THE FOLLOWING MATERIAL/EQUIPMENT: <br />A.LIGHTING FIXTURES. <br />B.SPECIAL OR BUILT-TO-ORDER EQUIPMENT. <br />26.LIGHTING FIXTURES SHALL BE COMPLETE WITH ALL GLASSWARE, FITTERS, CANOPIES, SOCKETS, <br />MOUNTING BRACKETS, REFLECTORS, LAMPS AND ALL ACCESSORIES AS REQUIRED. <br />27.FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING FIXTURES AND MANUFACTURER'S <br />CATALOG NUMBERS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO STUDY THE SCHEDULE AND <br />CAREFULLY REVIEW ELECTRICAL AND ARCHITECTURAL PLANS AND SPECIFICATIONS TO DETERMINE <br />THE CORRECT CEILING CONFIGURATION AND FIXTURES TO BE FURNISHED SO THAT BOTH CEILING <br />SYSTEM AND LIGHT FIXTURE CONSTRUCTION MATCHES. <br />28.COORDINATE EXACT LOCATION OF THE LIGHTING FIXTURES WITH THE ARCHITECTURAL DRAWINGS. IF <br />ANY DISCREPANCIES EXIST, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE UNIVERSITY'S <br />REPRESENTATIVE FOR CLARIFICATION PRIOR TO INSTALLATION. <br />29.LIGHTING FIXTURES FINISHES WHETHER OR NOT SHOWN ON THE DRAWINGS SHALL BE APPROVED BY <br />UNIVERSITY'S REPRESENTATIVE. <br />30.PROVIDE GROUNDING SYSTEM PER 2022 CEC AND AS INDICATED. <br />31.ALL METAL AND NON-CURRENT CARRYING PART OF THE ELECTRICAL EQUIPMENT SHALL BE BONDED TO <br />GROUND PER CEC CODE ARTICLE 250. <br />32.PROVIDE A TYPE-WRITTEN INDEX CARD FOR EACH PANEL BOARD INDICATING NAME OR NUMBER OF THE <br />ROOM, AREA, OR EQUIPMENT USED BY EACH BRANCH CIRCUIT. USE ROOM NUMBERS AND NAMES <br />VERIFIED IN THE FIELD AND NOT NECESSARILY THOSE SHOWN ON THE DRAWINGS. <br />33.PROVIDE FIREPROOFING FOR RECESS MOUNTED FIXTURES. RECEPTACLES, AND CONDUIT IN FIRE <br />RATED AREAS. SEE ARCHITECTURAL PLANS FOR DETAIL AND LOCATION. <br />34.ALL SHUTDOWN SHALL BE COORDINATED WITH THE UNIVERSITY'S REPRESENTATIVE. <br />35.TEMPORARY MATERIALS MUST BE REMOVED WITHOUT SHUTDOWN AS CONSTRUCTION PROGRESSES. <br />36.RESTORE PERMANENT FACILITIES TO THEIR FORMER OR NEWLY SPECIFIED CONDITION. <br />GENERAL NOTES <br />DESCRIPTION <br />W <br />V <br />LIGHT FIXTURE AS SPECIFIED, SUBSCRIPTS WHEN INDICATED DENOTE BRANCH <br />CIRCUIT/SWITCH LEG <br />CROSS LINES DENOTE NUMBER OF #12 WIRE, SIZE CONDUIT PER CODE AND AS NOTED ON <br />PLANS, NOT INCLUDING EQUIPMENT GROUND WIRE <br />FLUSH MOUNTED DOUBLE DUPLEX RECEPTACLE OUTLET @ +18" U.O.N. 125V 2P, 3W, 20A <br />(NEMA 5-20R) <br />FLUSH MOUNTED GFCI DUPLEX RECEPTACLE OUTLET @ +18" UON 125V 2P, 3W, 20A (NEMA 5-20R) <br />WHITE COLOR <br />FLUSH MOUNTED DUPLEX RECEPTACLE OUTLET @ +18" UON 125V 2P, 3W, 20A (NEMA 5-20R) <br />WHITE COLOR <br />E0.00:GENERAL NOTES, ABBREVIATIONS AND SYMBOLS <br />E0.10:SINGLE LINE DIAGRAM, AND PANEL SCHEDULES <br />E0.11:LIGHTING FIXTURE SCHEDULES <br />E1.00:ELECTRICAL SITE PLAN <br />E1.01:METER /MAIN LOCATION ELEVATION <br />E1.10:POWER PLAN <br />E1.11:MECHANICAL POWER PLAN <br />E1.12:ELECTRICAL ROOF PLAN <br />E2.10:LIGHTING PLAN <br />E2.11:EMERGENCY LIGHTING PHOTOMETRIC PLAN <br />E2.12:LIGHTING CONTROL DETAILS <br />E3.01:INDOOR LIGHTING TITLE 24 COMPLIANCE FORMS <br />E3.02:OUTDOOR LIGHTING TITLE 24 COMPLIANCE FORMS <br />E3.03:ELECTRICAL POWER DISTRIBUTION TITLE 24 COMPLIANCE FORMS <br />E4.01:ELECTRICAL DETAILS <br />ED1.10:ELECTRICAL DEMOLITION PLAN <br />DRAWING LIST: