Laserfiche WebLink
E2.12 <br />Scale <br />Jen Dunbar, AIA <br />phone: 310.435.3928 <br />12314 La Maida Street <br />Valley Village, CA 91607 <br />jen@dunbararchitecture.com <br />DUNBAR <br />ARCHITECTURE <br />No.Description Date <br />AS NOTED <br />Engineering Corp <br />Mechanical Electrical Plumbing <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA 92614 <br />TEL: 949.516.6480 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />LEC T R ICAL <br />EXP: 3-31-27 <br />EFORPDERETS <br />I <br />G <br />ER RE <br />EN <br />IGNE <br />LANOISS <br />CA L I FORNIASTATEOF <br />No. E21819 <br />E <br /> <br />ALI S A FAIAN <br />90% CD 5/02/2024 <br />CYPRESS STREET <br />FIRE STATION <br />REHABILITATION <br />CITY OF SANTA ANA <br />625 S. CYPRESS <br />SANTA ANA, CA <br />Project number <br />Date <br />Drawn by TP/HH <br />23004 <br />1/15/2025 <br />PERMIT SET 5/17/2024 <br />BACK CHECK SET 1/15/2025 <br />BACK CHECK SET_V2 4/08/2025 <br />LIGHTING <br />CONTROL <br />DETAILS <br />GENERAL NOTES: <br />1.REFER TO E2.10 FOR LIGHTING CIRCUITS AND CONTROL INTENT. <br />GENERAL NOTES: <br />LMRJ Series <br />Pre-Terminated <br />Cables or CAT5e. <br />LMRJ Series <br />Pre-Terminated <br />Cables or CAT5e. <br />RJ45 DIGITAL BUS CONNECTORS ARE <br />LOCATED ON EVERY DIGITAL DEVICE <br />(DIGITAL DEVICES ARE DEFINED AS: <br />RELAY PANELS, DIGITAL SWITCHES <br />AND ALL DIGITAL ACCESSORIES). <br />1 2 <br />NOTES: <br />1. OPEN TOPOLOGY CAT. 5 PATCH <br />CABLE WITH RJ45 CONNECTORS FROM <br />DIGITAL DEVICE TO DIGITAL DEVICE. <br />2. REFER TO MANUFACTURERS <br />INSTRUCTIONS FOR LONG DISTANCE <br />RUNS BETWEEN DIGITAL DEVICES. <br />RJ45 CONNECTORS USE THE SAME <br />COLOR CODING AS ETHERNET, AND <br />ARE MADE AS STRAIGHT THROUGH <br />CABLES. CROSS OVER CABLES WILL <br />CAUSE SYSTEM FAILURE. ALL CABLES <br />SUPPLIED BY CONTRACTOR. <br />RJ45 CONNECTOR <br />3 WHITE/GREEN <br />2 ORANGE <br />1 WHITE/ORANGE <br />4 BLUE <br />1 <br />8 BROWN <br />6 GREEN <br />5 WHITE/BLUE <br />7 WHITE/BROWN <br />ORANGE 2 <br />WHITE/BROWN 7 <br />BROWN 8 <br />GREEN 6 <br />WHITE/BLUE 5 <br />BLUE 4 <br />WHITE/GREEN 3 <br />WHITE/ORANGE 1 <br />DIGITAL BUS CONNECTORS <br />3 WHITE/GREEN <br />2 ORANGE <br />1 WHITE/ORANGE <br />4 BLUE <br />8 BROWN <br />6 GREEN <br />5 WHITE/BLUE <br />7 WHITE/BROWN <br />2 <br />RJ45 CONNECTOR <br />DIGITAL BUS CONNECTORS <br />2 2 <br />RJ45 CONNECTOR <br />3. UP TO 1,000 FT TOTAL BUS LENGTH. <br />4. CRIMP AND TEST EACH CABLE WITH <br />A LAN CIRCUIT TESTER PRIOR TO <br />INSTALLATION. <br />1 <br />2 3 4 <br />5 6 <br />OCCUPANCY SENSOR FOR AUTO SHUTOFF FOR CORRIDORS/HALLWAYS/STAIRWELLS <br />LMSW-108 <br />8 Button <br />Dimmer/Override Switch <br />Installation Example <br />LMDM-101 LMSW-101 LMSW-102 <br />LMSW-103 LMSW-104 LMSW-105 LMSW-108 <br />RAISE SCENE <br /> 1 <br />LOWER <br />ON/RAISE <br /> A <br />OFF/LOWER <br /> A <br />ON/RAISE <br /> B <br />RAISE <br /> A <br />LOWER <br /> A <br />ON/OFF <br /> A <br />ON <br />OFF <br />OFF/LOWER <br /> B <br />ON/RAISE <br /> A <br />OFF/ LOWER <br /> A <br />RAISE <br /> A <br />LOWER <br /> A <br />RAISE/ <br />ON A <br />LOWER <br />/OFF A <br />RAISE/ <br />ON B <br />LOWER <br />/OFF B <br />RAISE/ <br />ON C <br />LOWER <br />/OFF C <br />RAISE/ <br />ON D <br />LOWER <br />/OFF D <br />SCENE <br /> 2 <br />SCENE <br /> 3 <br />SCENE <br /> 4 <br />DLM SWITCH CONFIGURATION AND <br />TYPICAL BUTTON FUNCTION <br />USE ELCU-200 WITH INVERTER OR GENERATOR POWER <br />DLM 0-10 VOLT DIMMING ROOM CONTROLLER <br />MODEL# LMRC-111 OR LMRC-112 <br />LOW VOLTAGE DIMMER SWITCHES <br />MODEL# LMDM OR LMSW SERIES <br />CEILING OCCUPANCY SENSOR <br />LMDC-100 <br />TYPICAL LOW VOLTAGE NETWORK HOOK UP <br />CAT 5 WITH RJ45 CONNECTORS <br />UL 924 EMERGENCY CONTROL/SHUNT <br />MODEL# ECLU-200 <br />PRESS AND HOLD <br />FOR RAISE AND LOWER <br />TAP FOR ON <br />TAP FOR OFF <br />1A <br />B-PATTERN <br />NOTE:Radial coverage of 16 feet <br />LMRC-11X Series <br />Dimming Controller <br />Wiring Diagram <br />2 <br />DLM SWITCH <br />CAT 5 CABLE <br />W RJ45 CONNECTORS <br />4 <br />OS <br />* CONFIRM TYPE/QTY PER PLANS * <br />* CONFIRM TYPE/QTY PER PLANS * <br />DLM <br />OCCUPANCY SENSOR <br />LMDC-100 <br />2 <br />OS <br />* CONFIRM TYPE/QTY PER PLANS * <br />DLM <br />OCCUPANCY SENSOR <br />LMDC-100 <br />OS <br />* CONFIRM TYPE/QTY PER PLANS * <br />DLM <br />OCCUPANCY SENSOR <br />LMDC-100 <br />1A <br />Timeclock/Zone Controller <br />MODEL# LMZC-301 <br />LMZC-301 Zone Controller <br />GR <br />D <br />NE <br />U <br />11 <br />5 <br />v <br />27 <br />7 <br />v <br />120v or 277v <br />LMCT-100 <br />Wireless Configuration Tool <br />Include at least 1 LMCT <br />on every project. <br />1LMZC-301 <br />TIME CLOCK