Laserfiche WebLink
A0.1 <br />ARCHITECTURAL <br />SITE PLAN <br />SCALE: 1/8" = 1'-0" <br />ARCHITECTURAL SITE PLAN <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />LEGEND <br />N. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br />B <br />L <br />V <br />D <br />. <br />5' <br />- <br />6 <br />" <br />88 <br />' <br />- <br />6 <br />" <br />6' <br />- <br />0 <br />" <br />12'-0" <br />DEDICATION <br />129'-11"6'-4" <br />28 <br />' <br />- <br />0 <br />" <br />5' <br />- <br />6 <br />" <br />PROPOSED TRANSFORMER <br />150' FIRE DEPT. HOSE PULL <br />EXISTING FIRE HYDRANT <br />COLORED STAMPED <br />CONCRETE DRIVE <br />RESCUE WINDOW LOCATIONS <br />±148'-3" <br />±1 <br />0 <br />0 <br />' <br />- <br />0 <br />" <br />9' <br />- <br />0 <br />" <br />NOTE <br />1.ANY PROPOSED FENCING WITHIN THE FRONT <br />YARD AREA (E.G., TUBULAR FENCING SHOWN <br />ON LANDSCAPE PLANS) WOULD BE LIMITED <br />TO THREE FEET IN HEIGHT. PURSUANT TO SEC. <br />41-610 OF THE SAMC, FENCING IS PERMITTED <br />TO EXCEED THREE FEET, UP TO EIGHT FEET IN <br />HEIGHT, AFTER THE REQUIRED FRONT YARD <br />AREA. <br />2.PROPOSED SIX-FOOT TALL PERIMETER WALL <br />(SHOWN ON THE LANDSCAPE PLAN) BE OF A <br />DECORATIVE SPLIT-FACE WITH ANTI- GRAFFITI <br />COATING. <br />3.PEDESTRIAN-SCALED LIGHTING SHOULD BE <br />LOCATED ALONG ALL WALKWAYS WITHIN THE <br />DEVELOPMENT. WHERE APPROPRIATE, <br />WALL-MOUNTED LIGHTING MAY BE <br />INCORPORATED. THESE WALL-MOUNTED <br />LIGHTS SHOULD BE ARCHITECTURALLY <br />COMPATIBLE AND PEDESTRIAN SCALED <br />(CHAPTER 7 OF THE CITY DESIGN GUIDELINES). <br />4.LIGHTING LEVELS SHOULD BE SUFFICIENT TO <br />CREATE A PERCEIVED SENSE OF SECURITY <br />AND SAFETY, AND FOR SIDEWALK AND <br />STREET ILLUMINATION (SEE CHAPTER 7 OF <br />THE CITY DESIGN GUIDELINES). <br />5.GRIND AND CAP OF 2”-3” OF THE EXISTING AC <br />PAVEMENT FROM THE GUTTER LIP EDGE <br />ALONG THE MEDIAN TO THE GUTTER LIP EDGE <br />AT THE PROPERTY, ALONG THE ENTIRE <br />PROPERTY FRONTAGE. <br />6.EXISTING SIDEWALK ALONG THE ENTIRE <br />PROPERTY FRONTAGE SHALL BE REMOVED, <br />AND RECONSTRUCTED WITH A NEW 12' FULL <br />WIDTH SIDEWALK WITH TREE WELLS, ALONG <br />THE PROPERTY FRONTAGE ON HARBOR <br />BOULEVARD. <br />7.THIS SITE WILL BE DESIGNED AND <br />CONSTRUCTED IN ACCORDANCE WITH THE <br />CALIFORNIA REGIONAL WATER QUALITY <br />CONTROL BOARD SANTA ANA REGION ORDER <br />NO. R8-2009-0030 DISCHARGE REQUIREMENTS <br />(MS4 PERMIT). <br />8.PROJECT SHALL INSTALL OF TWO 24” BOX <br />STREET TREES ON HARBOR BOULEVARD, <br />INCLUDING DEEP ROOT IRRIGATION SYSTEMS, <br />PER CITY STANDARDS. CONTACT THE TREE <br />SECTION SUPERVISOR AT (714) 647-3337 FOR <br />TREE SPECIES AND SIZE OF REQUIRED TREES. <br />9.THE EXISTING SIDEWALK ALONG THE ENTIRE <br />PROPERTY FRONTAGE SHALL BE REMOVED <br />AND RECONSTRUCTED WITH A NEW 12’ FULL <br />WIDTH SIDEWALK WITH TREE WELLS, ALONG <br />THE PROPERTY FRONTAGE ON HARBOR <br />BOULEVARD. <br />10.TRASH ENCLOSURE AREA TO BE FULLY <br />ROOFED OR TO DRAIN INTO A WATER QUALITY <br />INLET TO PREVENT DISCHARGE OF SPILLED <br />CONTAMINANTS INTO THE STORM DRAIN <br />SYSTEM. <br />11.APPROPRIATE PRIVATE BACK FLOW <br />PREVENTER REQUIRED FOR ALL FIRE SERVICE, <br />DOMESTIC AND LANDSCAPE WATER METER <br />PER GRADING AND STREET IMPROVEMENT <br />PLANS (AS APPLICABLE) <br />12.ALL EXTERIOR BLOCK WALL FENCING OF <br />MULTIPLE-FAMILY DWELLING COMPLEXES <br />SHALL HAVE INTERVALS PROVIDING VISIBILITY <br />CORRIDORS, WHICH WILL ALLOW VISIBILITY <br />OF THE INTERIOR FROM OUTSIDE THE WALL, <br />AND THESE VISIBILITY CORRIDORS SHALL BE <br />PLACED AT REGULAR INTERVALS. THESE WILL <br />BE REQUIRED ON THE SIDE FACING THE <br />STREET ONLY. <br />4'-0" RIGHT- OF-WAY DEDICATION <br />TO THE CITY OF SANTA ANA <br />FOR STREET PURPOSES <br />8'-0" RIGHT-OF-WAY IRREVOCABLE <br />OFFER TO BE DEDICATED TO <br />THE CITY OF SANTA ANA FOR <br />FUTURE STREET PURPOSES <br />” <br />10 <br />' <br />- <br />0 <br />" <br />MI <br />N <br />. <br />46 <br />' <br />- <br />0 <br />" <br />9'-0" <br />EXISTING SIDE <br />WALK TO BE <br />REMOVED IN <br />FUTURE STREET <br />WIDENING <br />9' <br />- <br />0 <br />" <br />38 <br />' <br />- <br />0 <br />" <br />28 <br />' <br />- <br />0 <br />" <br />8'-0" <br />20'-0" <br />NO <br />R <br />T <br />H <br />1