My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
322 N Harbor Blvd - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Harbor Blvd
>
322 N Harbor Blvd
>
322 N Harbor Blvd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2026 11:14:40 AM
Creation date
2/24/2026 11:13:50 AM
Metadata
Fields
Template:
Plan
Permit Number
20183983
20183984
20183985
30147771
30147772
30147773
40139523
40139524
101120841
101120842
Full Address
322 N Harbor Blvd
Street Number
322
Street Direction
N
Street Name
Harbor
Street Suffix
Blvd
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
714
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
i - <br />Planning a y <br />Ap o w <br />FOR PER <br />ENGINEERING <br />DONG ENGINEERING, INC. <br />FITNESS ROOM ON 2ND FLOOR ., <br />(TOTAL OF 1 UNIT) HOA-1 F2 (TOTAL OF 1 UNIT) Master ID: GARDEN GROVE, CA 92841 <br />TEL- 714-617-5979 <br />O b Oa O b HOA-1 F4 Date: INFO@DONGENGINEERING.COM <br />RESTRICTIVE NOTICE <br />HOA-1 F6 SPECIFICATIONS ARE THE EXCLUSIVE <br />PROPERTY OF DONG ENGINEERING. <br />THESE DRAWINGS CANNOT BE COPIED, <br />TRANSFERRED, OR REPRODUCED NOR <br />CAN ANY OTHER STRUCTURES BE BUILT <br />FROM THEM WITHOUT WRITTEN CONSENT. <br />REVISIONS <br />�a b Oa O b <br />DATE REVISIONS <br />HOA-1 F14 <br />�b Oa CSC Oa Ob Oa <br />HOA-1 F8,10 <br />PROJECT OWNER <br />FAN COIL 0 <br />PROJECT ADDRESS <br />0 a HOA-1 F1 O <br />a HOA-1 F1 � <br />M b <br />Z 0 O <br />w J CV <br />m O <br />~ � Q <br />Q p U <br />LIGHTING PLAN POWER PLAN m <br />Q Of z <br />SCALE: 3 8" = 1 '-O" SCALE: 3 8" = 1 '-O" = Q <br />z z �- <br />ZD N Z <br />ELECTRICAL NOTES: (E.V. CHARGING) LEGEND N co < <br />CV <br />1. NEW ONE -AND TWO FAMILY DWELLINGS AND TOWNHOUSES, WITH <br />ATTACHED PRIVATE GARAGES, ARE REQUIRED TO CONTAIN A DUPLEX OUTLET <br />LISTED RACEWAY TO ACCOMMODATED A DEDICATED 208/240 VOLT <br />BRANCH CIRCUIT. THE RACEWAY SHALL NOT BE LESS THAN TRADE <br />SIZE 1 (NORMINAL 1-INCH INSIDE DIAMETER). THE RACEWAY SHALL <br />ORIGINATE AT THE MAIN SERVICE OR SUBPANEL AND SHALL BE <br />TERMINATED INTO A LISTED CABINET, BOX OR OTHER ENCLOSURE <br />IN CLOSE PROXIMITY TO THE PROPOSED LOCATION OF AN E.V. <br />CHARGER. THE SERVICE PANEL AND/OR SUBPANEL SHALL PROVIDE <br />CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED BRANCH <br />CIRCUIT AND SPACE(S) RESERVED TO PERMIT INSTALLATION OF A <br />BRANCH CIRCUIT OVER CURRENT PROTECTIVE DEVICE. <br />(CGBSC 4.106.4.1) <br />2. THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL <br />IDENTIFIED THE OVER CURRENT PROTECTIVE DEVICE SPACE(S) <br />RESERVED FOR FUTURE E.V. CHARGING AS "E.V. CAPABLE". THE <br />RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND <br />VISIBLE MAKED AS "E.V. CAPABLE:. (CGBSC 4.106.4.1.1) <br />ELECTRICAL NOTES: <br />1. ALL EQUIPMENT TO BE LISTED BY A RECOGNIZED TESTING LAB (I.E. U.L., <br />ETC.). <br />2. LIGHT FIXTURE IN CONTACT WITH INSULATION TO BE U.L. LISTED FOR <br />THERMAL BARRIER OR PROVIDE 3" MIN. CLEARANCE. <br />3. LIGHTS AND PANELS SHALL NOT BE RECESSED IN FIRE RATED <br />ASSEMBLIES UNLESS BOXED WITH EQUIVALENT CONSTRUCTION. <br />LIGHT FIXTURE SCHEDULE <br />SYMBOL <br />DESCRIPTION <br />MODEL NO. <br />MANUFACT. <br />0 <br />LED STRIP LIGHT, 2"x48", CEILING <br />MODEL LED SINGLE PART # <br />LITHONIA OR EQUAL <br />MOUNT, 120V, 64W <br />27072H <br />O <br />RECESSED MOUNTED LED LIGHT, <br />STYLE IV27A <br />LAMP PLUS OR <br />120V, 14W <br />EQUAL <br />PARKING LIGHT, TOP TIER 6500 <br />COPPER LIGHTING <br />Q <br />LUMENS, SURFACE MOUNT, <br />TT-D3-740-U-WD-NW <br />SOLUTION OR <br />WHITE, 120V, 47.2 W <br />EQUAL <br />eMS <br />WALL -MOUNT SECURITY LIGHT <br />W/ MOTION SENSOR PHOTOCELL, <br />AC106/35/1-OL <br />AC ELECTRONIC OR <br />EQUAL <br />120V, 37W <br />HARDWIRE SMOKE ALARM W/ <br />KIDDE SAFETY OR <br />LSD <br />• <br />BATTERY BACKUP 9V BATTERY <br />PART # 2129730 <br />EQUAL <br />INCLUDED, 120V, 20W <br />�. DUPLEX OUTLET (GFI) <br />PC PHOTO SENSOR <br />( EXHAUST FAN <br />STAMP <br />O SD SMOKE DETECTOR <br />. hu.;? <br />SWITCH <br />M SWITCH W/ MOTION DETECTOR <br />3 3-WAY SWITCH <br />(c <br />D SWITCH WITH DIMMER <br />DArrw:r:0*4r- W21, <br />1 <br />T> CIRCUIT BREAKER <br />DATE SIGNED: 12/24/24 <br />4. MOUNT THE FOLLOWING ABOVE FINISH FLOOR: <br />SHEET DESCRIPTION <br />OUTLETS - 15" TO 48" <br />SWITCHES -36"TO48" <br />1- <br />DISCONNECT SWITCH <br />THERMOSTATS - 36" TO 48" <br />I{ <br />MEASURED FROM BOTTOM AND TOP OF BOXES RESPECTIVELY <br />O ELECTRIC METER <br />5. PANEL CIRCUIT DIRECTORY TO COMPLY WITH SECT.408.4, CEC. <br />6. W.P. COVER OF OUTLETS TO COMPLY WITH SECT. 406.9(B)(1), CEC. <br />7. SEAL PENETRATIONS THROUGH FIRE RESISTIVE ASSEMBLY PER <br />LIGHTING PLAN <br />SECTION 714, CBC. <br />8. OUTDOOR LIGHTING SHOULD BE CUT-OFF LIGHTING AND FURNISHED W/ <br />POWER PLAN <br />PHOTOCELL LITHONIA MODEL OVWP OR EQUAL <br />FITNESS ROOM <br />(2ND FLOOR) <br />DE#: 230198 <br />SHEET <br />OS-E-109 <br />
The URL can be used to link to this page
Your browser does not support the video tag.