|
32
<br />2
<br />
<br />N
<br />.
<br />
<br />H
<br />A
<br />R
<br />B
<br />O
<br />R
<br />
<br />
<br />B
<br />L
<br />V
<br />D
<br />.
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />SHEET NUMBER
<br />2 0 2 4 0 1 0
<br />SHEET TITLE
<br />PROJECT NUMBER
<br />REVISIONS
<br />NO.DATE NO.DATE
<br />HANNOUCHE ARCHITECTS
<br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT
<br />AND OTHER PROPERTY RIGHTS INHERENT IN
<br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES,
<br />FIELD NOTES AND ASSOCIATED DOCUMENTS
<br />ARE INSTRUMENTS OF SERVICE AND ARE THE
<br />PROPERTY OF HANNOUCHE ARCHITECTS.
<br />ALL INFORMATION CONTAINED IN THESE DRAWINGS,
<br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED
<br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT
<br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED,
<br />OR USED OTHERWISE IN ANY FORM OR MANNER
<br />WHATSOEVER, WITHOUT FIRST OBTAINING THE
<br />EXPRESSED WRITTEN PERMISSION AND CONSENT
<br />OF HANNOUCHE ARCHITECTS.
<br />HANNOUCHE ARCHITECT c 2021
<br />HANNOUCHE
<br />ARCHITECTS
<br />949.261.2070
<br />SAMIR HANNOUCHE, ARCHITECT
<br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660
<br />May 9, 2025
<br />1 CORR
<br />12/10/24
<br />BLDG
<br />A CORR
<br />3/18/25
<br />OCFA
<br />2 CORR
<br />4/09/25
<br />BLDG
<br />DATE SIGNED2
<br />3 CORR
<br />5/09/25
<br />BLDG
<br />A0.17
<br />DWELLING ADA
<br />NOTES DETAILS
<br />SCALE: N/A
<br />SEC. 1127A.5 BATHING FACILITIES -
<br />1127 A.5 BATHING FACILITIES
<br />1127A.5.1 GENERAL. WHEN COMMON USE BATHING FACILITIES ARE PROVIDED FOR RESIDENTS OR GUESTS,
<br />INCLUDING SHOWERS, BATHTUBS OR LOCKERS, AT LEAST ONE OF EACH TYPE OF FIXTURE IN EACH
<br />FACILITY, AND NOT LESS THAN 1 PERCENT OF ALL FIXTURES, SHALL COMPLY WITH THIS SECTION.
<br />1127A.5.2 BATHTUBS. BATHTUBS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING:
<br />1127A.5.2.1 FLOOR SPACE. CLEARANCE IN FRONT OF BATHTUBS SHALL EXTEND THE LENGTH OF THE BATHTUB AND
<br />SHALL BE 48 INCHES (1219 MM) WIDE MINIMUM FOR FORWARD APPROACH AND 30 INCHES (762 MM) WIDE
<br />MINIMUM FOR PARALLEL APPROACH. A LAVATORY COMPLYING WITH SECTION 1127 A.3 (see detail XX this
<br />sheet) SHALL BE PERMITTED AT THE CONTROL END OF THE CLEARANCE. WHEN A PERMANENT SEAT IS
<br />PROVIDED AT THE HEAD END OF THE BATHTUB, THE CLEARANCE SHALL EXTEND 12 INCHES (305 MM)
<br />MINIMUM BEYOND THE WALL AT THE HEAD END OF THE BATHTUB. (SEE FIGURE 11A-9E)
<br />1127A.5.2.2 SEAT. A REMOVABLE IN-TUB SEAT OR A PERMANENT SEAT AT THE HEAD END OF THE TUB SHALL BE
<br />PROVIDED. THE STRUCTURAL STRENGTH OF SEATS AND THEIR ATTACHMENTS SHALL COMPLY WITH
<br />SECTION 1127A. 4.4 (see detail XX this sheet). SEATS SHALL BE MOUNTED SECURELY AND SHALL NOT SLIP
<br />DURING USE. THE TOP OF BATHTUB SEATS SHALL BE 17 INCHES (432 MM) MINIMUM AND 19 INCHES (483
<br />MM) MAXIMUM ABOVE THE BATHROOM FINISH FLOOR. THE DEPTH OF A REMOVABLE IN-TUB SEAT SHALL
<br />BE 15 INCHES (381 MM) MINIMUM AND 16 INCHES (406 MM) MAXIMUM. PERMANENT SEATS AT THE HEAD
<br />END OF THE BATHTUB SHALL BE 15 INCHES (381 MM) DEEP MINIMUM AND SHALL EXTEND FROM THE BACK
<br />WALL TO OR BEYOND THE OUTER EDGE OF THE BATHTUB. (SEE FIGURE 11A-9E).
<br />1127A.5.2.3 GRAB BARS. GRAB BARS COMPLYING WITH SECTION 1127A.4 (see detail XX this sheet) SHALL BE PROVIDED
<br />IN ACCORDANCE WITH THIS SECTION. (SEE FIGURE 11A-9F) WHEN SEPARATE GRAB BARS ARE REQUIRED
<br />ON ADJACENT WALLS AT A COMMON MOUNTING HEIGHT, AN L-SHAPED OR U-SHAPED GRAB BAR MEETING
<br />THE DIMENSIONAL REQUIREMENTS OF THIS SECTION SHALL BE PERMITTED.
<br />1. BATHTUBS WITH PERMANENT SEATS. TWO HORIZONTAL GRAB BARS SHALL BE INSTALLED ON THE
<br />BACK WALL. ONE SHALL BE LOCATED 33 INCHES (838 MM) MINIMUM AND 36 INCHES (914 MM) MAXIMUM
<br />ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, AND THE OTHER
<br />SHALL BE LOCATED 8 INCHES (203 MM) MINIMUM AND 10 INCHES (254 MM) MAXIMUM ABOVE THE RIM
<br />OF THE BATHTUB. EACH GRAB BAR SHALL BE 48 INCHES (1219 MM) LONG MINIMUM, AND SHALL BE
<br />INSTALLED 15 INCHES (381 MM) MAXIMUM FROM THE HEAD END WALL AND 12 INCHES (305 MM)
<br />MAXIMUM FROM THE CONTROL END WALL. A GRAB BAR 24 INCHES (610 MM) LONG MINIMUM SHALL BE
<br />INSTALLED ON THE CONTROL END WALL AT THE FRONT EDGE OF THE BATHTUB.
<br />2. BATHTUBS WITH REMOVABLE SEATS. TWO HORIZONTAL GRAB BARS SHALL BE INSTALLED ON THE
<br />BACK WALL. ONE SHALL BE LOCATED 33 INCHES (838 MM) MINIMUM AND 36 INCHES (914 MM) MAXIMUM
<br />ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, AND THE OTHER
<br />SHALL BE LOCATED 8 INCHES (203 MM) MINIMUM AND 10 INCHES (254 MM) MAXIMUM ABOVE THE RIM
<br />OF THE BATHTUB. EACH GRAB BAR SHALL BE 24 INCHES (610 MM) LONG MINIMUM AND SHALL BE
<br />INSTALLED 24 INCHES (610 MM) MAXIMUM FROM THE HEAD END WALL AND 12 INCHES (305 MM)
<br />MAXIMUM FROM THE CONTROL END WALL. A GRAB BAR 24 INCHES (610 MM) LONG MINIMUM SHALL BE
<br />INSTALLED ON THE CONTROL END WALL AT THE FRONT EDGE OF THE BATHTUB. A GRAB BAR 12
<br />INCHES (305 MM) LONG MINIMUM SHALL BE INSTALLED ON THE HEAD END WALL AT THE FRONT EDGE
<br />OF THE BATHTUB.
<br />1127A.5.2.4 CONTROLS. FAUCETS AND CONTROLS (OTHER THAN DRAIN STOPPERS) SHALL BE LOCATED ON AN END
<br />WALL BETWEEN THE BATHTUB RIM AND GRAB BAR, AND BETWEEN THE OPEN SIDE OF THE BATHTUB AND
<br />THE CENTERLINE OF THE WIDTH OF THE BATHTUB. (SEE FIGURE 11A-9F.) CONTROLS SHALL BE OPERABLE
<br />WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE
<br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS (22.2 N).1127 A.5.2.5
<br />SHOWER SPRAY UNIT. A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 59 INCHES (1524 MM) LONG
<br />THAT CAN BE USED BOTH AS A FIXED SHOWER HEAD AND AS A HAND-HELD SHOWER SHALL BE
<br />PROVIDED. THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL WITH A NON-POSITIVE SHUT-OFF
<br />IF AN ADJUSTABLE-HEIGHT SHOWER HEAD ON A VERTICAL BAR IS USED, THE BAR SHALL BE INSTALLED
<br />SO AS NOT TO OBSTRUCT THE USE OF THE GRAB BARS.
<br />1127 A.5.2.6 BATHTUB ENCLOSURES. WHEN PROVIDED, ENCLOSURES FOR BATHTUBS SHALL NOT OBSTRUCT
<br />CONTROLS, FAUCETS, SHOWER AND SPRAY UNITS, OR OBSTRUCT TRANSFER FROM WHEELCHAIRS ONTO
<br />BATHTUB SEATS OR INTO BATHTUBS. ENCLOSURES ON BATHTUBS SHALL NOT HAVE TRACKS INSTALLED
<br />ON THE RIM OF THE OPEN FACE OF THE BATHTUB.
<br />1127A.5.3 SHOWER COMPARTMENTS. SHOWER COMPARTMENTS REQUIRED TO BE ACCESSIBLE SHALL COMPLY
<br />WITH THIS SECTION. (SEE FIGURES 11A-9H, 11A-9I, 11A-9J AND 11A-9K) 1127A.5.3.1 SIZE AND
<br />CLEARANCE.
<br />1. STANDARD ROLL-IN SHOWER COMPARTMENTS. STANDARD ROLL-IN SHOWER COMPARTMENTS SHALL
<br />MEET ONE OF THE FOLLOWING:
<br />1.1 30 INCHES (762 MM) MINIMUM IN DEPTH AND 60 INCHES (1524 MM) MINIMUM IN WIDTH BETWEEN WALL
<br />SURFACES MEASURED AT CENTER POINTS OF OPPOSING SIDES, WITH A FULL OPENING WIDTH ON
<br />THE LONG SIDE. A CLEAR FLOOR SPACE 30 INCHES (914 MM) MINIMUM BY 60 INCHES (1524 MM)
<br />MINIMUM SHALL BE PROVIDED ADJACENT TO THE OPEN FACE OF THE SHOWER COMPARTMENT.
<br />1.2 42 INCHES (1067 MM) IN WIDTH BETWEEN WALL SURFACES, AND 48 INCHES (1219 MM) MINIMUM IN
<br />DEPTH WITH AN ENTRANCE OPENING OF 42 INCHES (1067 MM).
<br />2. ALTERNATE ROLL-IN SHOWER COMPARTMENTS. ALTERNATE ROLL-IN SHOWER COMPARTMENTS
<br />SHALL BE 36 INCHES (914 MM) MINIMUM IN DEPTH AND 60 INCHES (1524 MM) MINIMUM IN WIDTH
<br />BETWEEN WALL SURFACES MEASURED AT CENTER POINTS OF OPPOSING SIDES. A 36-INCH (914 MM)
<br />WIDE MINIMUM ENTRY SHALL BE PROVIDED AT ONE END OF THE LONG SIDE OF THE COMPARTMENT.
<br />1127A.5.3.2 THRESHOLDS. THRESHOLDS IN ROLL-IN SHOWER COMPARTMENTS SHALL BE 1/2 INCH (12.7 MM) MAXIMUM
<br />IN HEIGHT AND SHALL BE BEVELED WITH A SLOPE NO GREATER THAN ONE UNIT VERTICAL IN TWO UNITS
<br />HORIZONTAL (50-PERCENTSLOPE). (SEE FIGURE 11A-1F.)
<br />EXCEPTION:CHANGES IN LEVEL NOT EXCEEDING 1/4 INCH (6.35 MM) SHALL BE PERMITTED TO BE VERTICAL
<br />1127A.5.3.3 ENCLOSURES. ENCLOSURES, WHEN PROVIDED FOR SHOWER COMPARTMENTS, SHALL NOT OBSTRUCT
<br />CONTROLS, FAUCETS, SHOWER SPRAY UNITS, AND TRANSFER FROM WHEELCHAIRS ONTO SHOWER
<br />SEATS.
<br />1127 A.5.3.4 FLOOR. SHOWER COMPARTMENT FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. THE
<br />MAXIMUM SLOPE OF THE FLOOR SHALL BE 1/4 INCH (6.35 MM) PER FOOT (2.083 PERCENT SLOPE) IN ANY
<br />DIRECTION. WHEN DRAINS ARE PROVIDED, GRATE OPENINGS SHALL BE 1/4 INCH (6.35 MM) MAXIMUM AND
<br />LOCATED FLUSH WITH THE FLOOR SURFACE.
<br />1127 A.5.3.5 CONTROLS. CONTROLS, FAUCETS AND SHOWER SPRAY UNITS IN SHOWER COMPARTMENTS SHALL BE
<br />OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE
<br />WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) MAXIMUM.
<br />ALL CONTROLS AND FAUCETS SHALL BE OF A SINGLE-LEVER DESIGN.
<br />1127A.5.3.5.1 STANDARD ROLL-IN SHOWER COMPARTMENTS. IN STANDARD ROLL-IN SHOWER COMPARTMENTS,
<br />OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE INSTALLED ON THE BACK WALL OF THE
<br />COMPARTMENT ADJACENT TO THE SEAT WALL, 19 INCHES (483 MM) MINIMUM AND 27 INCHES (686 MM)
<br />MAXIMUM FROM THE SEAT WALL. OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE LOCATED
<br />ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES ( 1219 MM) ABOVE THE SHOWER FLOOR, WITH
<br />THEIR CENTERLINE AT 39 INCHES (991 MM) MINIMUM AND 41 INCHES ( 1041 MM) MAXIMUM ABOVE THE
<br />SHOWER FLOOR. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INCLUDING THE HANDLE, SHALL BE
<br />INSTALLED ON THE BACK WALL ADJACENT TO THE SEAT WALL, 19 INCHES (483 MM) MINIMUM AND 27
<br />INCHES (686 MM) MAXIMUM FROM THE SEAT WALL. OPERABLE PARTS OF THE SHOWER SPRAY UNIT,
<br />INCLUDING THE HANDLE, SHALL BE LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES
<br />(1219 MM) ABOVE THE SHOWER FLOOR (MEASURED TO THE TOP OF THE MOUNTING BRACKET).
<br />1127 A.5.3.5.2 ALTERNATE ROLL-IN SHOWER COMPARTMENTS. IN ALTERNATE ROLL-IN SHOWER COMPARTMENTS,
<br />OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE INSTALLED ON THE SIDE WALL OF THE
<br />COMPARTMENT ADJACENT TO THE SEAT WALL, 19 INCHES (483 MM) MINIMUM AND 27 INCHES ( 686 MM)
<br />MAXIMUM FROM THE SEAT WALL. OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE LOCATED
<br />ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES (1219 MM) ABOVE THE SHOWER FLOOR, WITH
<br />THEIR CENTERLINE AT 39 INCHES (991 MM) MINIMUM AND 41 INCHES (1041 MM) MAXIMUM ABOVE THE
<br />SHOWER FLOOR. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INCLUDING THE HANDLE, SHALL BE
<br />INSTALLED ON THE FOLLOWING LOCATIONS:
<br />1. ON THE SIDE WALL OF THE COMPARTMENT ADJACENT TO THE SEAT WALL, 17 INCHES (432 MM)
<br />MINIMUM AND 19 INCHES (483 MM) MAXIMUM FROM THE SEAT WALL; OR
<br />2. ON THE BACK WALL OPPOSITE THE SEAT, 15 INCHES (381 MM) MAXIMUM, LEFT OR RIGHT, OF THE
<br />CENTERLINE OF THE SEAT. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INCLUDING THE HANDLE,
<br />SHALL BE LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES (1219 MM) ABOVE THE
<br />SHOWER FLOOR.
<br />1127 A.5.3.6 HAND-HELD SHOWER SPRAYER UNIT. A FLEXIBLE HAND-HELD SHOWER SPRAY UNIT WITH A HOSE AT
<br />LEAST 59 INCHES (1524 MM) LONG THAT CAN BE USED BOTH AS A FIXED SHOWER HEAD AND AS A
<br />HAND-HELD SHOWER SHALL BE PROVIDED. THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL
<br />WITH A NON-POSITIVE SHUT-OFF IF AN ADJUSTABLE-HEIGHT SHOWER HEAD ON A VERTICAL BAR IS USED,
<br />THE BAR SHALL BE INSTALLED SO AS NOT TO OBSTRUCT THE USE OF GRAB BARS.
<br />1127A.5.3.6.1 SPRAYER UNIT ALTERNATIVE. WHEN ACCESSIBLE SHOWER FACILITIES ARE PROVIDED IN AREAS SUBJECT
<br />TO EXCESSIVE VANDALISM, IN LIEU OF PROVIDING THE FIXED FLEXIBLE HOSE, TWO WALL-MOUNTED
<br />SHOWER HEADS SHALL BE INSTALLED. EACH SHOWER HEAD SHALL BE INSTALLED SO THAT IT CAN BE
<br />OPERATED INDEPENDENTLY OF THE OTHER AND SHALL HAVE SWIVEL ANGLE ADJUSTMENTS, BOTH
<br />VERTICALLY AND HORIZONTALLY. ONE SHOWER HEAD SHALL BE LOCATED AT A HEIGHT OF 48 INCHES
<br />(1219 MM) MAXIMUM ABOVE THE FLOOR.
<br />1127 A.5.3. 7 SHOWER COMPARTMENT SEATS. A SEAT IN A STANDARD ROLL-IN SHOWER COMPARTMENT SHALL BE A
<br />FOLDING TYPE, INSTALLED ON THE SIDE WALL ADJACENT TO THE CONTROLS. THE SEAT SHALL EXTEND
<br />FROM THE BACK WALL TO A POINT WITHIN 3 INCHES (76 MM) OF THE COMPARTMENT ENTRY. A SEAT IN AN
<br />ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SHALL BE A FOLDING TYPE, INSTALLED ON THE
<br />FRONT WALL OPPOSITE THE BACK WALL, AND SHALL EXTEND FROM THE ADJACENT SIDE WALL TO A
<br />POINT WITHIN 3 INCHES (76 MM) OF THE COMPARTMENT ENTRY. SHOWER COMPARTMENT SEATS SHALL
<br />COMPLY WITH SECTION 1127 A.4.4 (see detail XX this sheet) AND SHALL BE LOCATED WITHIN 27 INCHES (686
<br />MM) OF THE SHOWER CONTROLS. THE TOP OF THE SEAT SHALL BE 17 INCHES (432 MM) MINIMUM AND 19
<br />INCHES (483 MM) MAXIMUM ABOVE THE BATHROOM FINISH FLOOR. WHEN FOLDED, THE SEAT SHALL NOT
<br />EXTEND MORE THAN 6 INCHES (152 MM) FROM THE MOUNTING WALL.
<br />1127A.5.3.7.1 RECTANGULAR SEATS. THE REAR EDGE OF A RECTANGULAR SEAT SHALL BE 2-1/2 INCHES (64 MM)
<br />MAXIMUM FROM THE SEAT WALL THE FRONT EDGE OF A RECTANGULAR SEAT SHALL BE 15 INCHES (381
<br />MM) MINIMUM AND 16 INCHES (406 MM) MAXIMUM FROM THE SEAT WALL. THE SIDE EDGE OF THE SEAT
<br />SHALL BE 1-1/2 INCHES (38 MM) MAXIMUM FROM THE ADJACENT WALL. 1127A.5.3.7.2 L-SHAPED SEATS. THE
<br />REAR EDGE OF AN L-SHAPED SEAT SHALL BE 2 1/ 2 INCHES (64 MM) MAXIMUM FROM THE SEAT WALL. THE
<br />FRONT EDGE OF AN L-SHAPED SEAT SHALL BE 15 INCHES (381 MM) MINIMUM AND 16 INCHES (406 MM)
<br />MAXIMUM FROM THE SEAT WALL. THE REAR EDGE OF THE "L" PORTION OF THE SEAT SHALL BE 1-1/2
<br />INCHES (38 MM) MAXIMUM FROM THE WALL. THE FRONT EDGE SHALL BE 14 INCHES (356 MM) MINIMUM
<br />AND 15 INCHES (381 MM) MAXIMUM FROM THE WALL. THE END OF THE "L" SHALL BE 22 INCHES (559 MM)
<br />MINIMUM AND 23 INCHES (584 MM) MAXIMUM FROM THE MAIN SEAT WALL.
<br />1127A.5.3.8 GRAB BARS. ACCESSIBLE SHOWER COMPARTMENTS SHALL BE PROVIDED WITH GRAB BARS, INSTALLED
<br />IN ACCORDANCE WITH SECTION 1127A.5.3.8.1 OR SECTION 1127 A.5.3.8.2. GRAB BARS SHALL ALSO
<br />COMPLY WITH SECTION 1127A.4 (see detail XX this sheet). WHEN MULTIPLE GRAB BARS ARE USED,
<br />REQUIRED HORIZONTAL GRAB BARS SHALL BE INSTALLED AT THE SAME HEIGHT ABOVE THE FINISH
<br />FLOOR. WHEN SEPARATE GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A COMMON MOUNTING
<br />HEIGHT, L-SHAPED OR U-SHAPED GRAB BARS MEETING THE DIMENSIONAL REQUIREMENTS OF SECTION
<br />1127A.5.3.8.1 OR SECTION 1127A.5.3.8.2 SHALL BE PERMITTED. (SEE FIGURE 11A-9H OR FIGURE 11A-9I.)
<br />1127A.5.3.8.1 STANDARD ROLL-IN SHOWER COMPARTMENTS. GRAB BARS SHALL BE INSTALLED ON THE BACK WALL
<br />AND ON THE SIDE WALL OPPOSITE THE SEAT. GRAB BARS ABOVE THE SEAT ARE NOT PERMITTED. GRAB
<br />BARS SHALL BE INSTALLED 6 INCHES (152 MM) MAXIMUM FROM ADJACENT WALLS.
<br />1127A.5.3.8.2 ALTERNATE ROLL-IN SHOWER COMPARTMENTS. GRAB BARS SHALL BE INSTALLED ON THE BACK WALL
<br />AND THE SIDE WALL FARTHEST FROM THE COMPARTMENT ENTRY. GRAB BARS ABOVE THE SEAT ARE NOT
<br />PERMITTED. GRAB BARS SHALL BE INSTALLED 6 INCHES (152 MM) MAXIMUM FROM ADJACENT WALLS.
<br />1127A.5.3.9 SOAP DISH. WHEN A SOAP DISH IS PROVIDED, IT SHALL BE LOCATED ON THE CONTROL WALL AT A
<br />MAXIMUM HEIGHT OF 40 INCHES (1016 MM) ABOVE THE SHOWER FLOOR, AND WITHIN THE REACH LIMITS
<br />FROM THE SEAT.
<br />1127A.5.3.10 OPEN SHOWERS. WHEN NO SEPARATE SHOWER COMPARTMENTS ARE PROVIDED, THE SHOWER FOR
<br />PERSONS WITH DISABILITIES SHALL BE LOCATED IN A CORNER WITH L-SHAPED GRAB BARS EXTENDING
<br />ALONG TWO ADJACENT WALLS WITH A FOLDING SEAT ADJACENT TO THE SHOWER CONTROLS. (SEE
<br />FIGURE 11A-9I)
<br />1127A.5.3.11 MULTIPLE SHOWERS. WHEN TWO OR MORE ACCESSIBLE SHOWERS ARE PROVIDED WITHIN THE SAME
<br />FUNCTIONAL AREA, THERE SHALL BE AT LEAST ONE SHOWER CONSTRUCTED OPPOSITE HAND FROM THE
<br />OTHER OR OTHERS (I.E., ONE LEFT-HAND CONTROL VERSUS RIGHT-HAND CONTROLS).
<br />1/
<br />4
<br />"
<br />MA
<br />X
<br />1/
<br />4
<br />"
<br />MA
<br />X
<br />1/
<br />4
<br />"
<br />MA
<br />X
<br />1/
<br />2
<br />"
<br />MA
<br />X
<br />(a)
<br />vertical change in level
<br />(b)
<br />beveled change in level
<br />2
<br />1
<br />FIGURE 11A-1F
<br />CHANGE IN LEVEL
<br />FIGURE 11A-9E
<br />CLEAR FLOOR SPACE AT BATHTUBS
<br />(see figure 11A-9F for size of grab bars)
<br />(b)
<br />removable in-tub seat parallel approach
<br />(d)
<br />permanent seat parallel approach
<br />co
<br />n
<br />t
<br />r
<br />o
<br />l
<br />
<br />e
<br />n
<br />d
<br />wa
<br />l
<br />l
<br />back wall
<br />he
<br />a
<br />d
<br />
<br />e
<br />n
<br />d
<br />
<br />w
<br />a
<br />l
<br />l
<br />(a)
<br />removable in-tub seat forward approach
<br />(c)
<br />permanent seat forward approach
<br />2'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />length of bathtub
<br />length of bathtub
<br />2'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />1'-0"
<br />MIN
<br />4'
<br />-
<br />0
<br />"
<br />
<br />M
<br />I
<br />N
<br />length of bathtub
<br />4'
<br />-
<br />0
<br />"
<br />
<br />M
<br />I
<br />N
<br />length of bathtub
<br />1'-0"
<br />MIN
<br />co
<br />n
<br />t
<br />r
<br />o
<br />l
<br />
<br />e
<br />n
<br />d
<br />wa
<br />l
<br />l
<br />back wall
<br />he
<br />a
<br />d
<br />
<br />e
<br />n
<br />d
<br />wa
<br />l
<br />l
<br />co
<br />n
<br />t
<br />r
<br />o
<br />l
<br />
<br />e
<br />n
<br />d
<br />wa
<br />l
<br />l
<br />back wall
<br />he
<br />a
<br />d
<br />
<br />e
<br />n
<br />d
<br />
<br />w
<br />a
<br />l
<br />l
<br />co
<br />n
<br />t
<br />r
<br />o
<br />l
<br />
<br />e
<br />n
<br />d
<br />wa
<br />l
<br />l
<br />back wall
<br />he
<br />a
<br />d
<br />
<br />e
<br />n
<br />d
<br />wa
<br />l
<br />l
<br />FIGURE 11A-9F
<br />GRAB BARS AT BATHTUBS
<br />(a)
<br />Removable In-Tub Seat
<br />(b)
<br />Permanent Seat
<br />17
<br />"
<br />
<br />-
<br />
<br />1
<br />9
<br />"
<br />17
<br />"
<br />
<br />-
<br />
<br />1
<br />9
<br />"
<br />15" - 16"15" - 16"
<br />1'-3"
<br />MIN
<br />1'-3"
<br />MIN
<br />2'-0"
<br />MIN1'-0"
<br />MAX
<br />2'-0"
<br />MAX
<br />4'-0"
<br />MIN1'-0"
<br />MAX
<br />1'-3"
<br />MAX
<br />℄
<br />control end (foot)
<br />wall
<br />back wall head end wall
<br />1'-0"
<br />MIN
<br />℄
<br />control end (foot)
<br />wall
<br />2'-0"
<br />MIN
<br />head end wallback wall
<br />6'
<br />-
<br />0
<br />"
<br />8"
<br />
<br />-
<br />
<br />1
<br />0
<br />"
<br />33
<br />"
<br />
<br />-
<br />
<br />3
<br />6
<br />"
<br />8"
<br />
<br />-
<br />
<br />1
<br />0
<br />"
<br />33
<br />"
<br />
<br />-
<br />
<br />3
<br />6
<br />"
<br />39
<br />"
<br />
<br />-
<br />
<br />4
<br />1
<br />"
<br />4'
<br />-
<br />0
<br />"
<br />
<br />M
<br />A
<br />X
<br />17
<br />"
<br />
<br />-
<br />
<br />1
<br />9
<br />"
<br />5'-0" MIN CLEAR
<br />FINISH TO FINISH
<br />33
<br />"
<br />
<br />-
<br />
<br />3
<br />6
<br />"
<br />5'-0" MIN CLEAR
<br />FINISH TO FINISH
<br />2'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />2'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />CL
<br />E
<br />A
<br />R
<br />FI
<br />N
<br />I
<br />S
<br />H
<br />TO
<br />
<br />
<br />F
<br />I
<br />N
<br />I
<br />S
<br />H
<br />5'-0" MIN.
<br />℄
<br />19" - 27"
<br />location of single
<br />lever controls
<br />1/2" max beveled
<br />threshold
<br />top of mounting
<br />bracket
<br />4'
<br />-
<br />0
<br />"
<br />top of
<br />mounting
<br />brackets
<br />2'-0"
<br />MIN
<br />6'
<br />-
<br />0
<br />"
<br />4'
<br />-
<br />0
<br />"
<br />top of
<br />mounting
<br />brackets
<br />clear floor area
<br />3'-6" MIN CLEAR
<br />FINISH TO FINISH
<br />4'
<br />-
<br />0
<br />"
<br />
<br />M
<br />I
<br />N
<br />
<br />CL
<br />E
<br />A
<br />R
<br />FI
<br />N
<br />I
<br />S
<br />H
<br />
<br />T
<br />O
<br />
<br />
<br />F
<br />I
<br />N
<br />I
<br />S
<br />H
<br />19" - 27"
<br />1/2" max beveled
<br />threshold
<br />location of single
<br />lever controls
<br />FIGURE 11A-9H
<br />STANDARD ROLL-IN SHOWERS
<br />folding seat
<br />folding seat
<br />seat extension
<br />over 36" deep
<br />3"
<br />MA
<br />X
<br />3"
<br />MA
<br />X
<br />standard fixed
<br />showerhead on the
<br />opposite wall
<br />(a)
<br />30" x 60" Roll-in Shower
<br />(b)
<br />42" x 48" Roll-in Shower
<br />handheld
<br />showerhead shall
<br />have a diverter from
<br />fixed head
<br />39
<br />"
<br />
<br />-
<br />
<br />4
<br />1
<br />"
<br />17
<br />"
<br />
<br />-
<br />
<br />1
<br />9
<br />"
<br />33
<br />"
<br />
<br />-
<br />
<br />3
<br />6
<br />"
<br />℄
<br />4'
<br />-
<br />0
<br />"
<br />
<br />M
<br />A
<br />X
<br />FIGURE 11A-9I
<br />SHOWER SEATS AND GRAB BARS
<br />(b1)
<br />rectangular
<br />(b2)
<br />L - shaped
<br />2
<br />1
<br />/
<br />2
<br />"
<br />MA
<br />X
<br />1 1/2"
<br />MAX
<br />15
<br />"
<br />
<br />-
<br />
<br />1
<br />6
<br />"
<br />seat wall
<br />1 1/2"
<br />MAX
<br />seat wall
<br />2
<br />1
<br />/
<br />2
<br />"
<br />MA
<br />X
<br />co
<br />m
<br />p
<br />a
<br />r
<br />t
<br />m
<br />e
<br />n
<br />t
<br />en
<br />t
<br />r
<br />y
<br />15
<br />"
<br />
<br />-
<br />
<br />1
<br />6
<br />"
<br />14" - 15"
<br />22
<br />"
<br />
<br />-
<br />
<br />2
<br />3
<br />"
<br />3"
<br />MAX
<br />co
<br />m
<br />p
<br />a
<br />r
<br />t
<br />m
<br />e
<br />n
<br />t
<br />en
<br />t
<br />r
<br />y
<br />3"
<br />MAX
<br />back wall
<br />si
<br />d
<br />e
<br />
<br />w
<br />a
<br />l
<br />l
<br />si
<br />d
<br />e
<br />
<br />w
<br />a
<br />l
<br />l
<br />6"
<br />6"
<br />(a2)
<br />standard roll-in shower
<br />(b)
<br />shower seats
<br />compartment entry
<br />(a)
<br />grab bars
<br />(a1)
<br />alternate roll-in shower
<br />back wall
<br />si
<br />d
<br />e
<br />
<br />w
<br />a
<br />l
<br />l
<br />si
<br />d
<br />e
<br />
<br />w
<br />a
<br />l
<br />l
<br />front wall
<br />compartment entry
<br />6"
<br />6"
<br />6"
<br />FIGURE 11A-9J
<br />OPEN SHOWER
<br />FIGURE 11A-9K
<br />ALTERNATE ROLL-IN SHOWER
<br />back wall
<br />si
<br />d
<br />e
<br />
<br />w
<br />a
<br />l
<br />l
<br />si
<br />d
<br />e
<br />
<br />w
<br />a
<br />l
<br />l
<br />front wall compartment
<br />entry
<br />5'-0" MIN CLEAR
<br />FINISH TO FINISH
<br />19
<br />"
<br />
<br />-
<br />
<br />2
<br />7
<br />"
<br />location of single
<br />lever controls
<br />1/2" max beveled
<br />threshold
<br />folding seat
<br />3'
<br />-
<br />0
<br />"
<br />
<br />M
<br />I
<br />N
<br />CL
<br />E
<br />A
<br />R
<br />FI
<br />N
<br />I
<br />S
<br />H
<br />TO
<br />
<br />
<br />F
<br />I
<br />N
<br />I
<br />S
<br />H
<br />2'-0"
<br />MIN
<br />3'-0" MIN
<br />39
<br />"
<br />
<br />-
<br />
<br />4
<br />1
<br />"
<br />4'
<br />-
<br />0
<br />"
<br />17
<br />"
<br />
<br />-
<br />
<br />1
<br />9
<br />"
<br />33
<br />"
<br />
<br />-
<br />
<br />3
<br />6
<br />"
<br />℄
<br />top of mounting
<br />bracket
<br />2'-1"
<br />35
<br />"
<br />
<br />-
<br />
<br />3
<br />7
<br />"
<br />3'
<br />-
<br />2
<br />"
<br />19" - 27"
<br />℄
<br />location of single
<br />lever controls
<br />folding seat
<br />19" - 27"
<br />2'-0"
<br />℄
<br />℄
<br />6'
<br />-
<br />0
<br />"
<br />36" grab bar
<br />24" grab bar
<br />SEC. 1127A.10 ACCESSIBLE LAUNDRY ROOMS -
<br />1127A.10 COMMON ACCESSIBLE LAUNDRY ROOMS
<br />1127A.10.1 GENERAL. WHERE COMMON USE LAUNDRY ROOMS ARE PROVIDED, AT LEAST ONE OF EACH TYPE OF
<br />APPLIANCE PROVIDED IN EACH LAUNDRY AREA SHALL BE ACCESSIBLE, SHALL BE ON AN ACCESSIBLE
<br />ROUTE AND SHALL COMPLY WITH THIS SECTION. SUCH APPLIANCES INCLUDE CLOTHES WASHING
<br />MACHINES, DRYERS, SOAP DISPENSERS AND ANY RELATED FEATURES SUCH AS WASH SINKS, TABLES
<br />AND STORAGE AREAS. WHERE LAUNDRY ROOMS ARE PROVIDED ON FLOORS OF AN ELEVATOR BUILDING,
<br />EACH LAUNDRY ROOM SHALL BE ACCESSIBLE. WHERE THERE IS ONE LAUNDRY ROOM ON A GROUND
<br />FLOOR IN EACH BUILDING, EACH LAUNDRY ROOM SHALL BE ACCESSIBLE. WHERE THERE IS A LAUNDRY
<br />ROOM ON THE GROUND FLOOR OF A BUILDING AND ANOTHER LOCATED IN THE BASEMENT, IT IS
<br />ACCEPTABLE TO HAVE ONLY THE GROUND FLOOR LAUNDRY ROOM ACCESSIBLE.
<br />1127A.10.2 CLEAR FLOOR SPACE. THERE SHALL BE A MINIMUM CLEAR SPACE 30 INCHES PERPENDICULAR BY 48
<br />INCHES PARALLEL (762 MM BY 1219 MM) IN FRONT OF CLOTHES WASHERS AND DRYERS REQUIRED TO BE
<br />ACCESSIBLE. THERE SHALL BE A MINIMUM CLEAR SPACE 30 INCHES BY 48 INCHES (762 MM BY 1219 MM)
<br />PROVIDED FOR AT LEAST ONE OF EACH TYPE OF FIXTURE OR APPLIANCE PROVIDED IN THE LAUNDRY
<br />ROOM (E.G., SOAP DISPENSERS, WASH SINKS, TABLES, STORAGE AREAS).
<br />1127A.10.3 CONTROLS AND OPERATING MECHANISMS. CLOTHES WASHERS AND DRYERS INCLUDING STACKED
<br />CLOTHES WASHERS AND DRYERS REQUIRED TO BE ACCESSIBLE SHALL HAVE CONTROLS AND OPERATING
<br />MECHANISMS (INCLUDING DOORS, COIN SLOTS, LINT SCREENS, DETERGENT AND BLEACH
<br />COMPARTMENTS) WITHIN THE REACH RANGE OF A SEATED USER. CONTROLS AND OPERATING
<br />MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48 INCHES (1219 MM), AND NO LOWER THAN 15 INCHES
<br />(381 MM), ABOVE THE FINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. IF THE REACH IS OVER
<br />AN OBSTRUCTION (FOR EXAMPLE, WASHER OR DRYER), OPERATING MECHANISMS SHALL BE LOCATED
<br />WITHIN THE REACH RANGES SPECIFIED IN SECTION 1138A.3 (see detail XX / XXX). CONTROLS AND
<br />OPERATING MECHANISMS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, PROVIDED
<br />THAT COMPARABLE MECHANISMS, CONTROLS OR OUTLETS THAT PERFORM THE SAME FUNCTIONS ARE
<br />PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. CONTROLS AND OPERATING MECHANISMS
<br />SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF
<br />THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS AND OPERATING MECHANISMS SHALL BE NO
<br />GREATER THAN 5 POUNDS (22.2N).
<br />1127A.10.4 WASHING MACHINES AND CLOTHES DRYERS. WASHING MACHINES AND CLOTHES DRYERS IN ACCESSIBLE
<br />COMMON USE LAUNDRY ROOMS SHALL BE FRONT LOADING. THE BOTTOM OF THE OPENING TO THE
<br />LAUNDRY COMPARTMENT SHALL BE LOCATED 15 INCHES ( 381 MM) MINIMUM AND 36 INCHES (914 MM)
<br />MAXIMUM ABOVE THE FINISH DOOR.
<br />HEIGHT OF FRONT LOADING LAUNDRY
<br />COMPARTMENT OPENING AND CONTROLS
<br />15
<br />"
<br />
<br />-
<br />
<br />3
<br />6
<br />"
<br />4'
<br />-
<br />0
<br />"
<br />
<br />M
<br />A
<br />X
<br />fr
<br />o
<br />n
<br />t
<br />
<br />m
<br />o
<br />u
<br />n
<br />t
<br />e
<br />d
<br />
<br />c
<br />o
<br />n
<br />t
<br />r
<br />o
<br />l
<br />s
<br />see 1138A.3 for obstructed
<br />high reach when controls are
<br />not front mounted
<br />CLEAR FLOOR AREA AT LAUNDRY EQUIPMENT
<br />2'-0" MIN ℄2'-0" MIN
<br />2'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />SEC. 1135A LAUNDRY ROOMS -
<br />SECTION 1135A LAUNDRY ROOMS
<br />1135A.1 GENERAL. IF CLOTHES WASHING MACHINES AND CLOTHES DRYERS ARE PROVIDED IN COVERED
<br />MULTIFAMILY DWELLING UNITS, ONE OF EACH TYPE OF APPLIANCE SHALL BE PROVIDED. WHERE FRONT
<br />LOADING CLOTHES WASHERS ARE NOT PROVIDED, MANAGEMENT SHALL PROVIDE ASSISTIVE DEVICES, ON
<br />REQUEST OF THE OCCUPANT, TO PERMIT THE USE OF TOP-LOADING CLOTHES WASHERS.
<br />12
<br />3
<br />4
<br />4
<br />A0.17
<br />4
<br />A0.17
<br />4
<br />A0.17
|