Laserfiche WebLink
32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />A0.17 <br />DWELLING ADA <br />NOTES DETAILS <br />SCALE: N/A <br />SEC. 1127A.5 BATHING FACILITIES - <br />1127 A.5 BATHING FACILITIES <br />1127A.5.1 GENERAL. WHEN COMMON USE BATHING FACILITIES ARE PROVIDED FOR RESIDENTS OR GUESTS, <br />INCLUDING SHOWERS, BATHTUBS OR LOCKERS, AT LEAST ONE OF EACH TYPE OF FIXTURE IN EACH <br />FACILITY, AND NOT LESS THAN 1 PERCENT OF ALL FIXTURES, SHALL COMPLY WITH THIS SECTION. <br />1127A.5.2 BATHTUBS. BATHTUBS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING: <br />1127A.5.2.1 FLOOR SPACE. CLEARANCE IN FRONT OF BATHTUBS SHALL EXTEND THE LENGTH OF THE BATHTUB AND <br />SHALL BE 48 INCHES (1219 MM) WIDE MINIMUM FOR FORWARD APPROACH AND 30 INCHES (762 MM) WIDE <br />MINIMUM FOR PARALLEL APPROACH. A LAVATORY COMPLYING WITH SECTION 1127 A.3 (see detail XX this <br />sheet) SHALL BE PERMITTED AT THE CONTROL END OF THE CLEARANCE. WHEN A PERMANENT SEAT IS <br />PROVIDED AT THE HEAD END OF THE BATHTUB, THE CLEARANCE SHALL EXTEND 12 INCHES (305 MM) <br />MINIMUM BEYOND THE WALL AT THE HEAD END OF THE BATHTUB. (SEE FIGURE 11A-9E) <br />1127A.5.2.2 SEAT. A REMOVABLE IN-TUB SEAT OR A PERMANENT SEAT AT THE HEAD END OF THE TUB SHALL BE <br />PROVIDED. THE STRUCTURAL STRENGTH OF SEATS AND THEIR ATTACHMENTS SHALL COMPLY WITH <br />SECTION 1127A. 4.4 (see detail XX this sheet). SEATS SHALL BE MOUNTED SECURELY AND SHALL NOT SLIP <br />DURING USE. THE TOP OF BATHTUB SEATS SHALL BE 17 INCHES (432 MM) MINIMUM AND 19 INCHES (483 <br />MM) MAXIMUM ABOVE THE BATHROOM FINISH FLOOR. THE DEPTH OF A REMOVABLE IN-TUB SEAT SHALL <br />BE 15 INCHES (381 MM) MINIMUM AND 16 INCHES (406 MM) MAXIMUM. PERMANENT SEATS AT THE HEAD <br />END OF THE BATHTUB SHALL BE 15 INCHES (381 MM) DEEP MINIMUM AND SHALL EXTEND FROM THE BACK <br />WALL TO OR BEYOND THE OUTER EDGE OF THE BATHTUB. (SEE FIGURE 11A-9E). <br />1127A.5.2.3 GRAB BARS. GRAB BARS COMPLYING WITH SECTION 1127A.4 (see detail XX this sheet) SHALL BE PROVIDED <br />IN ACCORDANCE WITH THIS SECTION. (SEE FIGURE 11A-9F) WHEN SEPARATE GRAB BARS ARE REQUIRED <br />ON ADJACENT WALLS AT A COMMON MOUNTING HEIGHT, AN L-SHAPED OR U-SHAPED GRAB BAR MEETING <br />THE DIMENSIONAL REQUIREMENTS OF THIS SECTION SHALL BE PERMITTED. <br />1. BATHTUBS WITH PERMANENT SEATS. TWO HORIZONTAL GRAB BARS SHALL BE INSTALLED ON THE <br />BACK WALL. ONE SHALL BE LOCATED 33 INCHES (838 MM) MINIMUM AND 36 INCHES (914 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, AND THE OTHER <br />SHALL BE LOCATED 8 INCHES (203 MM) MINIMUM AND 10 INCHES (254 MM) MAXIMUM ABOVE THE RIM <br />OF THE BATHTUB. EACH GRAB BAR SHALL BE 48 INCHES (1219 MM) LONG MINIMUM, AND SHALL BE <br />INSTALLED 15 INCHES (381 MM) MAXIMUM FROM THE HEAD END WALL AND 12 INCHES (305 MM) <br />MAXIMUM FROM THE CONTROL END WALL. A GRAB BAR 24 INCHES (610 MM) LONG MINIMUM SHALL BE <br />INSTALLED ON THE CONTROL END WALL AT THE FRONT EDGE OF THE BATHTUB. <br />2. BATHTUBS WITH REMOVABLE SEATS. TWO HORIZONTAL GRAB BARS SHALL BE INSTALLED ON THE <br />BACK WALL. ONE SHALL BE LOCATED 33 INCHES (838 MM) MINIMUM AND 36 INCHES (914 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING SURFACE, AND THE OTHER <br />SHALL BE LOCATED 8 INCHES (203 MM) MINIMUM AND 10 INCHES (254 MM) MAXIMUM ABOVE THE RIM <br />OF THE BATHTUB. EACH GRAB BAR SHALL BE 24 INCHES (610 MM) LONG MINIMUM AND SHALL BE <br />INSTALLED 24 INCHES (610 MM) MAXIMUM FROM THE HEAD END WALL AND 12 INCHES (305 MM) <br />MAXIMUM FROM THE CONTROL END WALL. A GRAB BAR 24 INCHES (610 MM) LONG MINIMUM SHALL BE <br />INSTALLED ON THE CONTROL END WALL AT THE FRONT EDGE OF THE BATHTUB. A GRAB BAR 12 <br />INCHES (305 MM) LONG MINIMUM SHALL BE INSTALLED ON THE HEAD END WALL AT THE FRONT EDGE <br />OF THE BATHTUB. <br />1127A.5.2.4 CONTROLS. FAUCETS AND CONTROLS (OTHER THAN DRAIN STOPPERS) SHALL BE LOCATED ON AN END <br />WALL BETWEEN THE BATHTUB RIM AND GRAB BAR, AND BETWEEN THE OPEN SIDE OF THE BATHTUB AND <br />THE CENTERLINE OF THE WIDTH OF THE BATHTUB. (SEE FIGURE 11A-9F.) CONTROLS SHALL BE OPERABLE <br />WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. THE <br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS (22.2 N).1127 A.5.2.5 <br />SHOWER SPRAY UNIT. A SHOWER SPRAY UNIT WITH A HOSE AT LEAST 59 INCHES (1524 MM) LONG <br />THAT CAN BE USED BOTH AS A FIXED SHOWER HEAD AND AS A HAND-HELD SHOWER SHALL BE <br />PROVIDED. THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL WITH A NON-POSITIVE SHUT-OFF <br />IF AN ADJUSTABLE-HEIGHT SHOWER HEAD ON A VERTICAL BAR IS USED, THE BAR SHALL BE INSTALLED <br />SO AS NOT TO OBSTRUCT THE USE OF THE GRAB BARS. <br />1127 A.5.2.6 BATHTUB ENCLOSURES. WHEN PROVIDED, ENCLOSURES FOR BATHTUBS SHALL NOT OBSTRUCT <br />CONTROLS, FAUCETS, SHOWER AND SPRAY UNITS, OR OBSTRUCT TRANSFER FROM WHEELCHAIRS ONTO <br />BATHTUB SEATS OR INTO BATHTUBS. ENCLOSURES ON BATHTUBS SHALL NOT HAVE TRACKS INSTALLED <br />ON THE RIM OF THE OPEN FACE OF THE BATHTUB. <br />1127A.5.3 SHOWER COMPARTMENTS. SHOWER COMPARTMENTS REQUIRED TO BE ACCESSIBLE SHALL COMPLY <br />WITH THIS SECTION. (SEE FIGURES 11A-9H, 11A-9I, 11A-9J AND 11A-9K) 1127A.5.3.1 SIZE AND <br />CLEARANCE. <br />1. STANDARD ROLL-IN SHOWER COMPARTMENTS. STANDARD ROLL-IN SHOWER COMPARTMENTS SHALL <br />MEET ONE OF THE FOLLOWING: <br />1.1 30 INCHES (762 MM) MINIMUM IN DEPTH AND 60 INCHES (1524 MM) MINIMUM IN WIDTH BETWEEN WALL <br />SURFACES MEASURED AT CENTER POINTS OF OPPOSING SIDES, WITH A FULL OPENING WIDTH ON <br />THE LONG SIDE. A CLEAR FLOOR SPACE 30 INCHES (914 MM) MINIMUM BY 60 INCHES (1524 MM) <br />MINIMUM SHALL BE PROVIDED ADJACENT TO THE OPEN FACE OF THE SHOWER COMPARTMENT. <br />1.2 42 INCHES (1067 MM) IN WIDTH BETWEEN WALL SURFACES, AND 48 INCHES (1219 MM) MINIMUM IN <br />DEPTH WITH AN ENTRANCE OPENING OF 42 INCHES (1067 MM). <br />2. ALTERNATE ROLL-IN SHOWER COMPARTMENTS. ALTERNATE ROLL-IN SHOWER COMPARTMENTS <br />SHALL BE 36 INCHES (914 MM) MINIMUM IN DEPTH AND 60 INCHES (1524 MM) MINIMUM IN WIDTH <br />BETWEEN WALL SURFACES MEASURED AT CENTER POINTS OF OPPOSING SIDES. A 36-INCH (914 MM) <br />WIDE MINIMUM ENTRY SHALL BE PROVIDED AT ONE END OF THE LONG SIDE OF THE COMPARTMENT. <br />1127A.5.3.2 THRESHOLDS. THRESHOLDS IN ROLL-IN SHOWER COMPARTMENTS SHALL BE 1/2 INCH (12.7 MM) MAXIMUM <br />IN HEIGHT AND SHALL BE BEVELED WITH A SLOPE NO GREATER THAN ONE UNIT VERTICAL IN TWO UNITS <br />HORIZONTAL (50-PERCENTSLOPE). (SEE FIGURE 11A-1F.) <br />EXCEPTION:CHANGES IN LEVEL NOT EXCEEDING 1/4 INCH (6.35 MM) SHALL BE PERMITTED TO BE VERTICAL <br />1127A.5.3.3 ENCLOSURES. ENCLOSURES, WHEN PROVIDED FOR SHOWER COMPARTMENTS, SHALL NOT OBSTRUCT <br />CONTROLS, FAUCETS, SHOWER SPRAY UNITS, AND TRANSFER FROM WHEELCHAIRS ONTO SHOWER <br />SEATS. <br />1127 A.5.3.4 FLOOR. SHOWER COMPARTMENT FLOOR SURFACES SHALL BE STABLE, FIRM AND SLIP RESISTANT. THE <br />MAXIMUM SLOPE OF THE FLOOR SHALL BE 1/4 INCH (6.35 MM) PER FOOT (2.083 PERCENT SLOPE) IN ANY <br />DIRECTION. WHEN DRAINS ARE PROVIDED, GRATE OPENINGS SHALL BE 1/4 INCH (6.35 MM) MAXIMUM AND <br />LOCATED FLUSH WITH THE FLOOR SURFACE. <br />1127 A.5.3.5 CONTROLS. CONTROLS, FAUCETS AND SHOWER SPRAY UNITS IN SHOWER COMPARTMENTS SHALL BE <br />OPERABLE WITH ONE HAND, AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE <br />WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2 N) MAXIMUM. <br />ALL CONTROLS AND FAUCETS SHALL BE OF A SINGLE-LEVER DESIGN. <br />1127A.5.3.5.1 STANDARD ROLL-IN SHOWER COMPARTMENTS. IN STANDARD ROLL-IN SHOWER COMPARTMENTS, <br />OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE INSTALLED ON THE BACK WALL OF THE <br />COMPARTMENT ADJACENT TO THE SEAT WALL, 19 INCHES (483 MM) MINIMUM AND 27 INCHES (686 MM) <br />MAXIMUM FROM THE SEAT WALL. OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE LOCATED <br />ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES ( 1219 MM) ABOVE THE SHOWER FLOOR, WITH <br />THEIR CENTERLINE AT 39 INCHES (991 MM) MINIMUM AND 41 INCHES ( 1041 MM) MAXIMUM ABOVE THE <br />SHOWER FLOOR. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INCLUDING THE HANDLE, SHALL BE <br />INSTALLED ON THE BACK WALL ADJACENT TO THE SEAT WALL, 19 INCHES (483 MM) MINIMUM AND 27 <br />INCHES (686 MM) MAXIMUM FROM THE SEAT WALL. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, <br />INCLUDING THE HANDLE, SHALL BE LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES <br />(1219 MM) ABOVE THE SHOWER FLOOR (MEASURED TO THE TOP OF THE MOUNTING BRACKET). <br />1127 A.5.3.5.2 ALTERNATE ROLL-IN SHOWER COMPARTMENTS. IN ALTERNATE ROLL-IN SHOWER COMPARTMENTS, <br />OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE INSTALLED ON THE SIDE WALL OF THE <br />COMPARTMENT ADJACENT TO THE SEAT WALL, 19 INCHES (483 MM) MINIMUM AND 27 INCHES ( 686 MM) <br />MAXIMUM FROM THE SEAT WALL. OPERABLE PARTS OF CONTROLS AND FAUCETS SHALL BE LOCATED <br />ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES (1219 MM) ABOVE THE SHOWER FLOOR, WITH <br />THEIR CENTERLINE AT 39 INCHES (991 MM) MINIMUM AND 41 INCHES (1041 MM) MAXIMUM ABOVE THE <br />SHOWER FLOOR. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INCLUDING THE HANDLE, SHALL BE <br />INSTALLED ON THE FOLLOWING LOCATIONS: <br />1. ON THE SIDE WALL OF THE COMPARTMENT ADJACENT TO THE SEAT WALL, 17 INCHES (432 MM) <br />MINIMUM AND 19 INCHES (483 MM) MAXIMUM FROM THE SEAT WALL; OR <br />2. ON THE BACK WALL OPPOSITE THE SEAT, 15 INCHES (381 MM) MAXIMUM, LEFT OR RIGHT, OF THE <br />CENTERLINE OF THE SEAT. OPERABLE PARTS OF THE SHOWER SPRAY UNIT, INCLUDING THE HANDLE, <br />SHALL BE LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 INCHES (1219 MM) ABOVE THE <br />SHOWER FLOOR. <br />1127 A.5.3.6 HAND-HELD SHOWER SPRAYER UNIT. A FLEXIBLE HAND-HELD SHOWER SPRAY UNIT WITH A HOSE AT <br />LEAST 59 INCHES (1524 MM) LONG THAT CAN BE USED BOTH AS A FIXED SHOWER HEAD AND AS A <br />HAND-HELD SHOWER SHALL BE PROVIDED. THE SHOWER SPRAY UNIT SHALL HAVE AN ON/OFF CONTROL <br />WITH A NON-POSITIVE SHUT-OFF IF AN ADJUSTABLE-HEIGHT SHOWER HEAD ON A VERTICAL BAR IS USED, <br />THE BAR SHALL BE INSTALLED SO AS NOT TO OBSTRUCT THE USE OF GRAB BARS. <br />1127A.5.3.6.1 SPRAYER UNIT ALTERNATIVE. WHEN ACCESSIBLE SHOWER FACILITIES ARE PROVIDED IN AREAS SUBJECT <br />TO EXCESSIVE VANDALISM, IN LIEU OF PROVIDING THE FIXED FLEXIBLE HOSE, TWO WALL-MOUNTED <br />SHOWER HEADS SHALL BE INSTALLED. EACH SHOWER HEAD SHALL BE INSTALLED SO THAT IT CAN BE <br />OPERATED INDEPENDENTLY OF THE OTHER AND SHALL HAVE SWIVEL ANGLE ADJUSTMENTS, BOTH <br />VERTICALLY AND HORIZONTALLY. ONE SHOWER HEAD SHALL BE LOCATED AT A HEIGHT OF 48 INCHES <br />(1219 MM) MAXIMUM ABOVE THE FLOOR. <br />1127 A.5.3. 7 SHOWER COMPARTMENT SEATS. A SEAT IN A STANDARD ROLL-IN SHOWER COMPARTMENT SHALL BE A <br />FOLDING TYPE, INSTALLED ON THE SIDE WALL ADJACENT TO THE CONTROLS. THE SEAT SHALL EXTEND <br />FROM THE BACK WALL TO A POINT WITHIN 3 INCHES (76 MM) OF THE COMPARTMENT ENTRY. A SEAT IN AN <br />ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SHALL BE A FOLDING TYPE, INSTALLED ON THE <br />FRONT WALL OPPOSITE THE BACK WALL, AND SHALL EXTEND FROM THE ADJACENT SIDE WALL TO A <br />POINT WITHIN 3 INCHES (76 MM) OF THE COMPARTMENT ENTRY. SHOWER COMPARTMENT SEATS SHALL <br />COMPLY WITH SECTION 1127 A.4.4 (see detail XX this sheet) AND SHALL BE LOCATED WITHIN 27 INCHES (686 <br />MM) OF THE SHOWER CONTROLS. THE TOP OF THE SEAT SHALL BE 17 INCHES (432 MM) MINIMUM AND 19 <br />INCHES (483 MM) MAXIMUM ABOVE THE BATHROOM FINISH FLOOR. WHEN FOLDED, THE SEAT SHALL NOT <br />EXTEND MORE THAN 6 INCHES (152 MM) FROM THE MOUNTING WALL. <br />1127A.5.3.7.1 RECTANGULAR SEATS. THE REAR EDGE OF A RECTANGULAR SEAT SHALL BE 2-1/2 INCHES (64 MM) <br />MAXIMUM FROM THE SEAT WALL THE FRONT EDGE OF A RECTANGULAR SEAT SHALL BE 15 INCHES (381 <br />MM) MINIMUM AND 16 INCHES (406 MM) MAXIMUM FROM THE SEAT WALL. THE SIDE EDGE OF THE SEAT <br />SHALL BE 1-1/2 INCHES (38 MM) MAXIMUM FROM THE ADJACENT WALL. 1127A.5.3.7.2 L-SHAPED SEATS. THE <br />REAR EDGE OF AN L-SHAPED SEAT SHALL BE 2 1/ 2 INCHES (64 MM) MAXIMUM FROM THE SEAT WALL. THE <br />FRONT EDGE OF AN L-SHAPED SEAT SHALL BE 15 INCHES (381 MM) MINIMUM AND 16 INCHES (406 MM) <br />MAXIMUM FROM THE SEAT WALL. THE REAR EDGE OF THE "L" PORTION OF THE SEAT SHALL BE 1-1/2 <br />INCHES (38 MM) MAXIMUM FROM THE WALL. THE FRONT EDGE SHALL BE 14 INCHES (356 MM) MINIMUM <br />AND 15 INCHES (381 MM) MAXIMUM FROM THE WALL. THE END OF THE "L" SHALL BE 22 INCHES (559 MM) <br />MINIMUM AND 23 INCHES (584 MM) MAXIMUM FROM THE MAIN SEAT WALL. <br />1127A.5.3.8 GRAB BARS. ACCESSIBLE SHOWER COMPARTMENTS SHALL BE PROVIDED WITH GRAB BARS, INSTALLED <br />IN ACCORDANCE WITH SECTION 1127A.5.3.8.1 OR SECTION 1127 A.5.3.8.2. GRAB BARS SHALL ALSO <br />COMPLY WITH SECTION 1127A.4 (see detail XX this sheet). WHEN MULTIPLE GRAB BARS ARE USED, <br />REQUIRED HORIZONTAL GRAB BARS SHALL BE INSTALLED AT THE SAME HEIGHT ABOVE THE FINISH <br />FLOOR. WHEN SEPARATE GRAB BARS ARE REQUIRED ON ADJACENT WALLS AT A COMMON MOUNTING <br />HEIGHT, L-SHAPED OR U-SHAPED GRAB BARS MEETING THE DIMENSIONAL REQUIREMENTS OF SECTION <br />1127A.5.3.8.1 OR SECTION 1127A.5.3.8.2 SHALL BE PERMITTED. (SEE FIGURE 11A-9H OR FIGURE 11A-9I.) <br />1127A.5.3.8.1 STANDARD ROLL-IN SHOWER COMPARTMENTS. GRAB BARS SHALL BE INSTALLED ON THE BACK WALL <br />AND ON THE SIDE WALL OPPOSITE THE SEAT. GRAB BARS ABOVE THE SEAT ARE NOT PERMITTED. GRAB <br />BARS SHALL BE INSTALLED 6 INCHES (152 MM) MAXIMUM FROM ADJACENT WALLS. <br />1127A.5.3.8.2 ALTERNATE ROLL-IN SHOWER COMPARTMENTS. GRAB BARS SHALL BE INSTALLED ON THE BACK WALL <br />AND THE SIDE WALL FARTHEST FROM THE COMPARTMENT ENTRY. GRAB BARS ABOVE THE SEAT ARE NOT <br />PERMITTED. GRAB BARS SHALL BE INSTALLED 6 INCHES (152 MM) MAXIMUM FROM ADJACENT WALLS. <br />1127A.5.3.9 SOAP DISH. WHEN A SOAP DISH IS PROVIDED, IT SHALL BE LOCATED ON THE CONTROL WALL AT A <br />MAXIMUM HEIGHT OF 40 INCHES (1016 MM) ABOVE THE SHOWER FLOOR, AND WITHIN THE REACH LIMITS <br />FROM THE SEAT. <br />1127A.5.3.10 OPEN SHOWERS. WHEN NO SEPARATE SHOWER COMPARTMENTS ARE PROVIDED, THE SHOWER FOR <br />PERSONS WITH DISABILITIES SHALL BE LOCATED IN A CORNER WITH L-SHAPED GRAB BARS EXTENDING <br />ALONG TWO ADJACENT WALLS WITH A FOLDING SEAT ADJACENT TO THE SHOWER CONTROLS. (SEE <br />FIGURE 11A-9I) <br />1127A.5.3.11 MULTIPLE SHOWERS. WHEN TWO OR MORE ACCESSIBLE SHOWERS ARE PROVIDED WITHIN THE SAME <br />FUNCTIONAL AREA, THERE SHALL BE AT LEAST ONE SHOWER CONSTRUCTED OPPOSITE HAND FROM THE <br />OTHER OR OTHERS (I.E., ONE LEFT-HAND CONTROL VERSUS RIGHT-HAND CONTROLS). <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />4 <br />" <br />MA <br />X <br />1/ <br />2 <br />" <br />MA <br />X <br />(a) <br />vertical change in level <br />(b) <br />beveled change in level <br />2 <br />1 <br />FIGURE 11A-1F <br />CHANGE IN LEVEL <br />FIGURE 11A-9E <br />CLEAR FLOOR SPACE AT BATHTUBS <br />(see figure 11A-9F for size of grab bars) <br />(b) <br />removable in-tub seat parallel approach <br />(d) <br />permanent seat parallel approach <br />co <br />n <br />t <br />r <br />o <br />l <br /> <br />e <br />n <br />d <br />wa <br />l <br />l <br />back wall <br />he <br />a <br />d <br /> <br />e <br />n <br />d <br /> <br />w <br />a <br />l <br />l <br />(a) <br />removable in-tub seat forward approach <br />(c) <br />permanent seat forward approach <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />length of bathtub <br />length of bathtub <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />1'-0" <br />MIN <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />length of bathtub <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />length of bathtub <br />1'-0" <br />MIN <br />co <br />n <br />t <br />r <br />o <br />l <br /> <br />e <br />n <br />d <br />wa <br />l <br />l <br />back wall <br />he <br />a <br />d <br /> <br />e <br />n <br />d <br />wa <br />l <br />l <br />co <br />n <br />t <br />r <br />o <br />l <br /> <br />e <br />n <br />d <br />wa <br />l <br />l <br />back wall <br />he <br />a <br />d <br /> <br />e <br />n <br />d <br /> <br />w <br />a <br />l <br />l <br />co <br />n <br />t <br />r <br />o <br />l <br /> <br />e <br />n <br />d <br />wa <br />l <br />l <br />back wall <br />he <br />a <br />d <br /> <br />e <br />n <br />d <br />wa <br />l <br />l <br />FIGURE 11A-9F <br />GRAB BARS AT BATHTUBS <br />(a) <br />Removable In-Tub Seat <br />(b) <br />Permanent Seat <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />15" - 16"15" - 16" <br />1'-3" <br />MIN <br />1'-3" <br />MIN <br />2'-0" <br />MIN1'-0" <br />MAX <br />2'-0" <br />MAX <br />4'-0" <br />MIN1'-0" <br />MAX <br />1'-3" <br />MAX <br />℄ <br />control end (foot) <br />wall <br />back wall head end wall <br />1'-0" <br />MIN <br />℄ <br />control end (foot) <br />wall <br />2'-0" <br />MIN <br />head end wallback wall <br />6' <br />- <br />0 <br />" <br />8" <br /> <br />- <br /> <br />1 <br />0 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />8" <br /> <br />- <br /> <br />1 <br />0 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />39 <br />" <br /> <br />- <br /> <br />4 <br />1 <br />" <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />5'-0" MIN CLEAR <br />FINISH TO FINISH <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />5'-0" MIN CLEAR <br />FINISH TO FINISH <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />. <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br />FI <br />N <br />I <br />S <br />H <br />TO <br /> <br /> <br />F <br />I <br />N <br />I <br />S <br />H <br />5'-0" MIN. <br />℄ <br />19" - 27" <br />location of single <br />lever controls <br />1/2" max beveled <br />threshold <br />top of mounting <br />bracket <br />4' <br />- <br />0 <br />" <br />top of <br />mounting <br />brackets <br />2'-0" <br />MIN <br />6' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />top of <br />mounting <br />brackets <br />clear floor area <br />3'-6" MIN CLEAR <br />FINISH TO FINISH <br />4' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br /> <br />CL <br />E <br />A <br />R <br />FI <br />N <br />I <br />S <br />H <br /> <br />T <br />O <br /> <br /> <br />F <br />I <br />N <br />I <br />S <br />H <br />19" - 27" <br />1/2" max beveled <br />threshold <br />location of single <br />lever controls <br />FIGURE 11A-9H <br />STANDARD ROLL-IN SHOWERS <br />folding seat <br />folding seat <br />seat extension <br />over 36" deep <br />3" <br />MA <br />X <br />3" <br />MA <br />X <br />standard fixed <br />showerhead on the <br />opposite wall <br />(a) <br />30" x 60" Roll-in Shower <br />(b) <br />42" x 48" Roll-in Shower <br />handheld <br />showerhead shall <br />have a diverter from <br />fixed head <br />39 <br />" <br /> <br />- <br /> <br />4 <br />1 <br />" <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />℄ <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />FIGURE 11A-9I <br />SHOWER SEATS AND GRAB BARS <br />(b1) <br />rectangular <br />(b2) <br />L - shaped <br />2 <br />1 <br />/ <br />2 <br />" <br />MA <br />X <br />1 1/2" <br />MAX <br />15 <br />" <br /> <br />- <br /> <br />1 <br />6 <br />" <br />seat wall <br />1 1/2" <br />MAX <br />seat wall <br />2 <br />1 <br />/ <br />2 <br />" <br />MA <br />X <br />co <br />m <br />p <br />a <br />r <br />t <br />m <br />e <br />n <br />t <br />en <br />t <br />r <br />y <br />15 <br />" <br /> <br />- <br /> <br />1 <br />6 <br />" <br />14" - 15" <br />22 <br />" <br /> <br />- <br /> <br />2 <br />3 <br />" <br />3" <br />MAX <br />co <br />m <br />p <br />a <br />r <br />t <br />m <br />e <br />n <br />t <br />en <br />t <br />r <br />y <br />3" <br />MAX <br />back wall <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />6" <br />6" <br />(a2) <br />standard roll-in shower <br />(b) <br />shower seats <br />compartment entry <br />(a) <br />grab bars <br />(a1) <br />alternate roll-in shower <br />back wall <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />front wall <br />compartment entry <br />6" <br />6" <br />6" <br />FIGURE 11A-9J <br />OPEN SHOWER <br />FIGURE 11A-9K <br />ALTERNATE ROLL-IN SHOWER <br />back wall <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />si <br />d <br />e <br /> <br />w <br />a <br />l <br />l <br />front wall compartment <br />entry <br />5'-0" MIN CLEAR <br />FINISH TO FINISH <br />19 <br />" <br /> <br />- <br /> <br />2 <br />7 <br />" <br />location of single <br />lever controls <br />1/2" max beveled <br />threshold <br />folding seat <br />3' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br />FI <br />N <br />I <br />S <br />H <br />TO <br /> <br /> <br />F <br />I <br />N <br />I <br />S <br />H <br />2'-0" <br />MIN <br />3'-0" MIN <br />39 <br />" <br /> <br />- <br /> <br />4 <br />1 <br />" <br />4' <br />- <br />0 <br />" <br />17 <br />" <br /> <br />- <br /> <br />1 <br />9 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />℄ <br />top of mounting <br />bracket <br />2'-1" <br />35 <br />" <br /> <br />- <br /> <br />3 <br />7 <br />" <br />3' <br />- <br />2 <br />" <br />19" - 27" <br />℄ <br />location of single <br />lever controls <br />folding seat <br />19" - 27" <br />2'-0" <br />℄ <br />℄ <br />6' <br />- <br />0 <br />" <br />36" grab bar <br />24" grab bar <br />SEC. 1127A.10 ACCESSIBLE LAUNDRY ROOMS - <br />1127A.10 COMMON ACCESSIBLE LAUNDRY ROOMS <br />1127A.10.1 GENERAL. WHERE COMMON USE LAUNDRY ROOMS ARE PROVIDED, AT LEAST ONE OF EACH TYPE OF <br />APPLIANCE PROVIDED IN EACH LAUNDRY AREA SHALL BE ACCESSIBLE, SHALL BE ON AN ACCESSIBLE <br />ROUTE AND SHALL COMPLY WITH THIS SECTION. SUCH APPLIANCES INCLUDE CLOTHES WASHING <br />MACHINES, DRYERS, SOAP DISPENSERS AND ANY RELATED FEATURES SUCH AS WASH SINKS, TABLES <br />AND STORAGE AREAS. WHERE LAUNDRY ROOMS ARE PROVIDED ON FLOORS OF AN ELEVATOR BUILDING, <br />EACH LAUNDRY ROOM SHALL BE ACCESSIBLE. WHERE THERE IS ONE LAUNDRY ROOM ON A GROUND <br />FLOOR IN EACH BUILDING, EACH LAUNDRY ROOM SHALL BE ACCESSIBLE. WHERE THERE IS A LAUNDRY <br />ROOM ON THE GROUND FLOOR OF A BUILDING AND ANOTHER LOCATED IN THE BASEMENT, IT IS <br />ACCEPTABLE TO HAVE ONLY THE GROUND FLOOR LAUNDRY ROOM ACCESSIBLE. <br />1127A.10.2 CLEAR FLOOR SPACE. THERE SHALL BE A MINIMUM CLEAR SPACE 30 INCHES PERPENDICULAR BY 48 <br />INCHES PARALLEL (762 MM BY 1219 MM) IN FRONT OF CLOTHES WASHERS AND DRYERS REQUIRED TO BE <br />ACCESSIBLE. THERE SHALL BE A MINIMUM CLEAR SPACE 30 INCHES BY 48 INCHES (762 MM BY 1219 MM) <br />PROVIDED FOR AT LEAST ONE OF EACH TYPE OF FIXTURE OR APPLIANCE PROVIDED IN THE LAUNDRY <br />ROOM (E.G., SOAP DISPENSERS, WASH SINKS, TABLES, STORAGE AREAS). <br />1127A.10.3 CONTROLS AND OPERATING MECHANISMS. CLOTHES WASHERS AND DRYERS INCLUDING STACKED <br />CLOTHES WASHERS AND DRYERS REQUIRED TO BE ACCESSIBLE SHALL HAVE CONTROLS AND OPERATING <br />MECHANISMS (INCLUDING DOORS, COIN SLOTS, LINT SCREENS, DETERGENT AND BLEACH <br />COMPARTMENTS) WITHIN THE REACH RANGE OF A SEATED USER. CONTROLS AND OPERATING <br />MECHANISMS SHALL BE LOCATED NO HIGHER THAN 48 INCHES (1219 MM), AND NO LOWER THAN 15 INCHES <br />(381 MM), ABOVE THE FINISHED FLOOR MEASURED TO THE CENTER OF THE GRIP. IF THE REACH IS OVER <br />AN OBSTRUCTION (FOR EXAMPLE, WASHER OR DRYER), OPERATING MECHANISMS SHALL BE LOCATED <br />WITHIN THE REACH RANGES SPECIFIED IN SECTION 1138A.3 (see detail XX / XXX). CONTROLS AND <br />OPERATING MECHANISMS THAT DO NOT SATISFY THESE SPECIFICATIONS ARE ACCEPTABLE, PROVIDED <br />THAT COMPARABLE MECHANISMS, CONTROLS OR OUTLETS THAT PERFORM THE SAME FUNCTIONS ARE <br />PROVIDED WITHIN THE SAME AREA AND ARE ACCESSIBLE. CONTROLS AND OPERATING MECHANISMS <br />SHALL BE OPERABLE WITH ONE HAND AND NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF <br />THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS AND OPERATING MECHANISMS SHALL BE NO <br />GREATER THAN 5 POUNDS (22.2N). <br />1127A.10.4 WASHING MACHINES AND CLOTHES DRYERS. WASHING MACHINES AND CLOTHES DRYERS IN ACCESSIBLE <br />COMMON USE LAUNDRY ROOMS SHALL BE FRONT LOADING. THE BOTTOM OF THE OPENING TO THE <br />LAUNDRY COMPARTMENT SHALL BE LOCATED 15 INCHES ( 381 MM) MINIMUM AND 36 INCHES (914 MM) <br />MAXIMUM ABOVE THE FINISH DOOR. <br />HEIGHT OF FRONT LOADING LAUNDRY <br />COMPARTMENT OPENING AND CONTROLS <br />15 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />4' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />fr <br />o <br />n <br />t <br /> <br />m <br />o <br />u <br />n <br />t <br />e <br />d <br /> <br />c <br />o <br />n <br />t <br />r <br />o <br />l <br />s <br />see 1138A.3 for obstructed <br />high reach when controls are <br />not front mounted <br />CLEAR FLOOR AREA AT LAUNDRY EQUIPMENT <br />2'-0" MIN ℄2'-0" MIN <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />SEC. 1135A LAUNDRY ROOMS - <br />SECTION 1135A LAUNDRY ROOMS <br />1135A.1 GENERAL. IF CLOTHES WASHING MACHINES AND CLOTHES DRYERS ARE PROVIDED IN COVERED <br />MULTIFAMILY DWELLING UNITS, ONE OF EACH TYPE OF APPLIANCE SHALL BE PROVIDED. WHERE FRONT <br />LOADING CLOTHES WASHERS ARE NOT PROVIDED, MANAGEMENT SHALL PROVIDE ASSISTIVE DEVICES, ON <br />REQUEST OF THE OCCUPANT, TO PERMIT THE USE OF TOP-LOADING CLOTHES WASHERS. <br />12 <br />3 <br />4 <br />4 <br />A0.17 <br />4 <br />A0.17 <br />4 <br />A0.17