Laserfiche WebLink
32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />A0.19 <br />DWELLING ADA <br />NOTES DETAILS <br />SCALE: N/A <br />SEC. 1143A SIGNAGE - <br />SECTION 1143A SIGNAGE <br />1143A.1 GENERAL. WHEN SIGNS AND/OR IDENTIFICATION DEVICES ARE PROVIDED THEY SHALL COMPLY WITH THIS <br />SECTION. WHEN BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH <br />VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS ONE WITH VISUAL, AND ONE WITH TACTILE <br />CHARACTERS, SHALL BE PROVIDED. <br />EXCEPTION:SIGNS NEED NOT BE PROVIDED WITHIN DWELLING UNITS. <br />NOTE:SEE SECTION 1127A.7 (see detail XX / XXX) FOR ADDITIONAL SIGNAGE REQUIREMENTS APPLICABLE TO SANITARY <br />FACILITIES, AND SECTION 1124A (see detail XX / XXX) FOR ADDITIONAL SIGNAGE REQUIREMENTS APPLICABLE TO <br />ELEVATORS. <br />1143A.2 IDENTIFICATION SIGNS. WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES OF A BUILDING OR SITE, THEY <br />SHALL COMPLY WITH SECTIONS 1143A.J, JJ43A.5, 1143A.6 AND 1143A.7. <br />EXCEPTION:EXTERIOR SIGNS THAT ARE NOT LOCATED AT THE DOOR TO THE SPACE THEY SERVE SHALL NOT BE REQUIRED <br />TO COMPLY WITH SECTION 1143A.6. <br />1143A.3 DIRECTIONAL AND INFORMATIONAL SIGNS. WHEN SIGNS DIRECT TO OR GIVE INFORMATION ABOUT PERMANENT <br />ROOMS AND SPACES OF A BUILDING OR SITE, THEY SHALL COMPLY WITH SECTIONS 1143A.5. <br />1143A.4 ACCESSIBILITY SIGNS. WHEN SIGNS IDENTIFY, DIRECT OR GIVE INFORMATION ABOUT ACCESSIBLE ELEMENTS <br />AND FEATURES OF A BUILDING OR SITE, THEY SHALL INCLUDE THE APPROPRIATE SYMBOL OF ACCESSIBILITY <br />AND SHALL COMPLY WITH SECTION 1143A.5. <br />1143A.5 VISUAL CHARACTERS. SIGNS WITH VISUAL CHARACTERS SHALL COMPLY WITH THIS SECTION. <br />1. FINISH AND CONTRAST. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. <br />CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT ON A DARK BACKGROUND OR <br />DARK ON A LIGHT BACKGROUND. <br />2. CHARACTER TYPE. CHARACTERS SHALL BE UPPERCASE, LOWERCASE OR A COMBINATION OF BOTH. <br />CHARACTERS SHALL BE CONVENTIONAL IN FORM, AND SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY <br />DECORATIVE, OR OF OTHER UNUSUAL FORMS. <br />3. PROPORTIONS. CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE <br />UPPERCASE LETTER "0" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE <br />UPPERCASE LETTER " I ". <br />4. CHARACTER HEIGHT. VISUAL CHARACTERS SHALL BE SIZED IN ACCORDANCE WITH TABLE 1143A.5. VIEWING <br />DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN <br />OBSTRUCTION PREVENTING FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE <br />BASED ON THE UPPERCASE LETTER " I ". <br />5. HEIGHT FROM FINISH FLR. VISUAL CHARACTERS SHALL BE 40 INCHES (1016 MM) MIN. ABOVE THE FINISH <br />FLOOR. <br />EXCEPTIONS: <br />1. VISUAL CHARACTERS INDICATING ELEVATOR CAR CONTROLS. <br />2. FLOOR-LEVEL EXIT SIGNS COMPLYING WITH CHAPTER 10, SECTION 1011.6. <br />6. STROKE THICKNESS. STROKE THICKNESS OF THE UPPERCASE LETTER " I " SHALL BE 10 PERCENT MINIMUM <br />AND 20 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER. <br />7. CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS <br />OF ADJACENT CHARACTERS,EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL CHARACTERS <br />SHALL BE 10 PERCENT MINIMUM AND 35 PERCENT MAXIMUM OF CHARACTER HEIGHT. <br />8. LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A <br />MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE CHARACTER HEIGHT. <br />9. CHARACTER FORMAT. TEXT SHALL BE IN A HORIZONTAL FORMAT. <br /> 1143A.6 RAISED CHARACTERS AND PICTORIAL SYMBOL SIGNS. WHEN RAISED CHARACTERS ARE REQUIRED OR WHEN <br />PICTORIAL SYMBOLS (PICTOGRAMS) ARE USED ON SUCH SIGNS, THEY SHALL COMPLY WITH THIS SECTION. <br />RAISED CHARACTERS AND PICTORIAL SYMBOLS SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION <br />1143A.7. <br />1. CHARACTER TYPE. RAISED CHARACTERS ON SIGNS SHALL BE 1/32 INCH (0.8 MM) MINIMUM ABOVE THEIR <br />BACKGROUND. CHARACTERS SHALL BE SANS SERIF UPPERCASE, AND SHALL NOT BE ITALIC, OBLIQUE, <br />SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS. <br />2. CHARACTER HEIGHT. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE <br />CHARACTER SHALL BE 5/8 INCH (15.9 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUM BASED ON THE HEIGHT <br />OF THE UPPERCASE LETTER " I ". <br />3. CHARACTER FORMAT. CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT. <br />4. PROPORTIONS. RAISED CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHEN THE WIDTH OF <br />THE UPPERCASE LETTER " O " IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF <br />THE UPPERCASE LETTER " I ". <br />5. STROKE THICKNESS. STROKE THICKNESS OF THE UPPERCASE LETTER " I " SHALL BE 15 PERCENT MAXIMUM <br />OF THE HEIGHT OF THE CHARACTER. <br />6. CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS <br />OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHEN CHARACTERS <br />HAVE RECTANGULAR CROSS SECTIONS,SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8 <br />INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. WHEN <br />CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL <br />BE 1/16 INCH (1.6 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE <br />BASE OF THE CROSS SECTIONS, AND 1/8 INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER <br />STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED <br />FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8 INCH (9.5 MM) MINIMUM. <br />7.LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A <br />MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER <br />HEIGHT. <br />8.LOCATION. WHEN A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE <br />DOOR AT THE LATCH SIDE. WHEN A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF, <br />THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHEN A TACTILE SIGN IS PROVIDED AT DOUBLE <br />DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR. <br />WHEN THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF <br />DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING <br />TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (457 MM) <br />MINIMUM BY 18 INCHES (457 MM) MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED <br />BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. <br />WHEN PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE <br />LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT <br />IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR <br />SPACE. <br />9. HEIGHT. SIGNS WITH RAISED CHARACTERS SHALL BE LOCATED 48 INCHES (1219 MM) MINIMUM ABOVE THE <br />FINISH FLOOR, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES (1524 MM) <br />MAXIMUM ABOVE THE FINISH FLOOR, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED <br />CHARACTERS. <br />EXCEPTION: <br />TACTILE CHARACTERS FOR ELEVATOR CAR CONTROLS SHALL NOT BE REQUIRED TO COMPLY WITH <br />THIS SECTION. <br />10.PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE <br />ACCOMPANIED BY A TEXT DESCRIPTION LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. THE TEXT <br />DESCRIPTION SHALL COMPLY WITH SECTIONS 1143A.6 AND 1143A.7. THE OUTSIDE DIMENSION OF THE <br />PICTOGRAM FIELD SHALL BE A MINIMUM OF 6 INCHES (152 MM) IN HEIGHT. CHARACTERS AND BRAILLE <br />SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. <br />1143A.7 BRAILLE. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER <br />PORTIONS OF THESE STANDARDS. <br />1143A.7.1 DIMENSIONS AND CAPITALIZATION. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL <br />COMPLY WITH TABLE 1143A.7.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED <br />BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE <br />ALPHABET, INITIALS, AND ACRONYMS. <br />1. Measured center to center <br />1143A.7.2 POSITION. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT, <br />FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. <br />BRAILLE SHALL BE SEPARATED 3 INCH (9.5 MM) MINIMUM AND 1/2 INCH (12.7 MM) MAXIMUM FROM ANY OTHER <br />TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS. <br />EXCEPTION:BRAILLE PROVIDED ON ELEVATOR CAR CONTROLS SHALL BE SEPARATED 3116 INCH (4.8 MM) MINIMUM AND <br />SHALL BE LOCATED DIRECTLY BELOW THE CORRESPONDING RAISED CHARACTERS OR SYMBOLS. <br />1143A.8 SYMBOLS OF ACCESSIBILITY. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NON-GLARE <br />FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER A LIGHT <br />SYMBOL ON A DARK BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND. SYMBOLS OF <br />ACCESSIBILITY SHALL COMPLY WITH THE FOLLOWING: <br />1. INTERNATIONAL SYMBOL OF ACCESSIBILITY. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL <br />CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE COLOR NO. 15090 IN FEDERAL <br />STANDARD 595B. (SEE FIGURE 11A-1A.) <br />2. INTERNATIONAL SYMBOL OF TTY. (SEE FIGURE 11A-11C; detail XX this sheet) <br />3. VOLUME CONTROL TELEPHONES. (SEE FIGURE 11A-11D; detail XX this sheet) <br />4. ASSISTIVE LISTENING SYSTEMS. (SEE FIGURE 11A-11E; detail XX this sheet) <br />5. CLEANER AIR SYMBOL. (SEE CHAPTER 11B; see detail X / XXX) <br />6. TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. (SEE SECTION 1127A.7; see detail X / XXX) <br />TABLE 1143A.5 VISUAL CHARACTER HEIGHT <br />HEIGHT TO FINISH FLOOR OR GROUND <br />FROM BASELINE OF CHARACTER <br />HORIZONTAL VIEWING <br />DISTANCE MINIMUM CHARACTER HEIGHT <br />40 INCHES (1016 MM) TO <br />LESS THAN OR EQUAL TO 70 <br />INCHES (1778 MM) <br />LESS THAN 72 INCHES <br />(1829 MM) <br />5 8 INCH (15.9 MM) <br />72 INCHES (1829 MM) AND <br />GREATER <br />5 8 INCH (15.9 MM), PLUS 18 INCH (3.2 MM) PER <br />FOOT (305 MM) OF VIEWING DISTANCE ABOVE <br />72 INCHES (1829 MM) <br />GREATER THAN 70 INCHES (1778 MM) <br />TO LESS THAN OR EQUAL TO 120 <br />INCHES (3048 MM) <br />LESS THAN 180 INCHES <br />(4572 MM) <br />2 INCHES (51 MM) <br />180 INCHES (4572 MM) AND <br />GREATER <br />2 INCHES (51 MM), PLUS 18 INCH (3.2 MM) PER <br />FOOT (305 MM) OF VIEWING DISTANCE ABOVE <br />180 INCHES (4572 MM) <br />GREATER THAN 120 INCHES (3048 MM)LESS THAN 21 FEET (6401 <br />MM) <br />3 INCHES (76 MM) <br />21 FEET (6401 MM) AND <br />GREATER <br />3 INCHES (76 MM), PLUS 18 INCH (3.2 MM) PER <br />FOOT (305 MM) OF VIEWING DISTANCE ABOVE <br />21 FEET (6401 MM) <br />TABLE 1143A.7.1 BRAILLE DIMENSIONS <br />MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES <br />DOT BASE DIAMETER 0.059" (1.5 MM) TO 0.063" (1.6 MM) <br />DISTANCE BETWEEN TWO DOTS IN THE SAME CELLS ¹0.100" (2.5 MM) <br />DISTANCE BETWEEN CORRESPONDING DOTS IN <br />ADJACENT CELLS ¹ <br />0.300" (7.6 MM) <br />DOT HEIGHT 0.025" (0.6 MM) TO 0.037" (0.9 MM) <br />DISTANCE BETWEEN TWO CORRESPONDING DOTS <br />FROM ONE CELL DIRECTLY BELOW ¹ <br />0.395" (10.0 MM) TO 0.400" (10.2 MM) <br />FIGURE 11A-1A <br />INTERNATIONAL ACCESSIBILITY SYMBOL <br />(a) <br />symbol proportions <br />(b) <br />display conditions <br />SEC. 1124A ELEVATORS AND (WHEELCHAIR) PLATFORM LIFTS - <br />SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS <br />1124A.1 GENERAL. ELEVATORS PROVIDED IN COVERED MULTIFAMILY BUILDINGS SHALL BE ACCESSIBLE. ELEVATORS <br />REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THIS CHAPTER, ASME A17.1, SAFETY CODE FOR ELEVATORS <br />AND ESCALATORS, TITLE 8, OF THE CALIFORNIA CODE OF REGULATIONS, UNDER "ELEVATOR SAFETY ORDERS," <br />AND ANY OTHER APPLICABLE SAFETY REGULATIONS OF OTHER ADMINISTRATIVE AUTHORITIES HAVING <br />JURISDICTION. <br />EXCEPTION:PRIVATE ELEVATORS SERVING ONLY ONE DWELLING UNIT. <br />1124A.2 LOCATION. PASSENGER ELEVATORS SHALL BE LOCATED ON A MAJOR ACCESSIBLE ROUTE AND PROVISIONS <br />SHALL BE MADE TO ENSURE THAT THEY REMAIN ACCESSIBLE AND USABLE AT ALL TIMES THAT THE BUILDING IS <br />OCCUPIED. <br />1124A.3 SIZE OF CAB AND CONTROL LOCATIONS. <br />1124A.3.1 GENERAL. ELEVATORS SERVING COVERED MULTIFAMILY BUILDINGS SHALL BE SIZED TO ACCOMMODATE A <br />WHEELCHAIR IN ACCORDANCE WITH THIS SECTION. <br />EXCEPTION:WHEN THE ENFORCING AGENCY DETERMINES THAT COMPLIANCE WITH ANY REQUIREMENT OF THIS SECTION <br />WOULD CREATE AN UNREASONABLE HARDSHIP, AN EXCEPTION TO THE REQUIREMENT SHALL BE GRANTED <br />WHEN EQUIVALENT FACILITATION IS PROVIDED, AND WHERE IT CAN BE DEMONSTRATED THAT A PERSON USING <br />A WHEELCHAIR CAN ENTER AND OPERATE THE ELEVATOR. <br />1124A.3.2 CAR INSIDE. THE CAR INSIDE SHALL ALLOW FOR THE TURNING OF A WHEELCHAIR. THE MINIMUM CLEAR <br />DISTANCE BETWEEN WALLS OR BETWEEN WALL AND DOOR, EXCLUDING RETURN PANELS, SHALL NOT BE LESS <br />THAN 80 INCHES BY 54 INCHES (2032 MM BY 1372 MM) FOR CENTER-OPENING DOORS, AND 68 INCHES BY 54 <br />INCHES (1727 MM BY 1372 MM) FOR SIDE-SLIDE OPENING DOORS. (SEE FIGURE 11A-7A). MINIMUM DISTANCE FROM <br />WALL TO RETURN PANEL SHALL NOT BE LESS THAN 51 INCHES (1295 MM). <br />1124A.3.2.1 DOOR SIZE. ELEVATOR DOORS SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 36 INCHES (914 MM). <br />1124A.3.3 CAR CONTROLS. <br />1124A.3.3.1 CAR CONTROL LOCATION. ELEVATOR FLOOR BUTTONS SHALL BE WITHIN 54 INCHES (1372 MM) ABOVE THE FINISH <br />FLOOR FOR SIDE APPROACH AND 48 INCHES (1219 MM) FOR FRONT APPROACH. EXCEPT FOR PHOTOELECTRIC <br />TUBE BYPASS SWITCHES, EMERGENCY CONTROLS, INCLUDING THE EMERGENCY STOP AND ALARM, SHALL BE <br />GROUPED IN OR ADJACENT TO THE BOTTOM OF THE PANEL AND SHALL BE NO LOWER THAN 35 INCHES (889 MM) <br />FROM THE FLOOR. FOR MULTIPLE CONTROLS ONLY, ONE SET MUST COMPLY WITH THESE HEIGHT <br />REQUIREMENTS. FLOOR BUTTONS SHALL BE PROVIDED WITH VISUAL INDICATORS TO SHOW WHEN EACH CALL IS <br />REGISTERED. THE VISUAL INDICATORS SHALL BE EXTINGUISHED WHEN EACH CALL IS ANSWERED. <br />NOTE:WHERE POSSIBLE, A 48-INCH (1219 MM) MAXIMUM HEIGHT FOR ELEVATOR FLOOR BUTTONS IS <br />PREFERRED. <br />1124A.3.3.2 CAR CONTROL BUTTONS. PASSENGER ELEVATOR CAR CONTROLS SHALL HAVE A MINIMUM DIMENSION OF 3/4 <br />INCH (19.1 MM) AND SHALL BE RAISED 1/8 INCH (3.2 MM) PLUS OR MINUS 1/32 INCH (0.8 MM) ABOVE THE <br />SURROUNDING SURFACE. CONTROL BUTTONS SHALL BE ILLUMINATED, SHALL HAVE SQUARE SHOULDERS AND <br />SHALL BE ACTIVATED BY A MECHANICAL MOTION THAT IS DETECTABLE. ALL CONTROL BUTTONS SHALL BE <br />DESIGNATED BY A 5/8-INCH MINIMUM( 15.9 MM) RAISED CHARACTERS AND STANDARD RAISED SYMBOLS THAT <br />COMPLY WITH SECTIONS 1143A.6 AND 1143A.7 (see detail XX / XXX) IMMEDIATELY TO THE LEFT OF THE CONTROL <br />BUTTON. CONTRACTED GRADE 2 BRAILLE THAT CONFORMS TO SECTION 1143A.7 SHALL BE LOCATED <br />IMMEDIATELY BELOW THE NUMERAL, CHARACTER OR SYMBOL. A MINIMUM CLEAR SPACE OF3/ 8 INCH (9.5 MM) <br />OR OTHER SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF CONTROL BUTTONS. <br />(SEE FIGURE 11A-7B.) THE RAISED CHARACTERS AND SYMBOLS SHALL BE WHITE ON A BLACK BACKGROUND. <br />CONTROLS AND EMERGENCY EQUIPMENT IDENTIFIED BY RAISED SYMBOLS SHALL INCLUDE, BUT NOT BE LIMITED <br />TO, "DOOR OPEN," "DOOR CLOSE," "ALARM BELL," "EMERGENCY STOP" AND "TELEPHONE." THE CALL BUTTON FOR <br />THE MAIN ENTRY FLOOR SHALL BE DESIGNATED BY A RAISED STAR AT THE LEFT OF THE FLOOR DESIGNATION. <br />1124A.3.4 EMERGENCY TELEPHONE. THE EMERGENCY TELEPHONE HANDSET SHALL BE POSITIONED NO HIGHER THAN 48 <br />INCHES (1219 MM) ABOVE THE FLOOR, AND THE HANDSET CORD SHALL BE A MINIMUM OF29 INCHES (737 MM) IN <br />LENGTH. IF THE TELEPHONE SYSTEM IS LOCATED IN A CLOSED COMPARTMENT, THE COMPARTMENT DOOR <br />HARDWARE SHALL CONFORM TO THE PROVISIONS OF SECTION 1138A.4.4 (see detail XX / XXX). EMERGENCY <br />INTERCOMMUNICATION SHALL NOT REQUIRE VOICE COMMUNICATION. <br />1124A.4 HALL CALL BUTTONS. CALL OPERATION BUTTONS SHALL BE CENTERED 42 INCHES (1067 MM) ABOVE THE FLOOR. <br />BUTTONS SHALL BE A MINIMUM OF 3/8 INCH ( 19.1 MM) IN SIZE AND SHALL BE RAISED 1/8-INCH (3.2 MM) PLUS OR <br />MINUS 1/32-INCH (0.8 MM) ABOVE THE SURROUNDING SURFACE. THE BUTTON DESIGNATING THE "UP" DIRECTION <br />SHALL BE ON TOP. VISUAL INDICATION SHALL BE PROVIDED TO SHOW EACH CALL REGISTERED EXTINGUISHED <br />WHEN ANSWERED. OBJECTS ADJACENT TO, AND BELOW, HALL CALL BUTTONS SHALL NOT PROJECT MORE THAN <br />4 INCHES (101.6 MM) FROM THE WALL. HALL CALL BUTTONS SHALL BE INTERNALLY ILLUMINATED WITH A WHITE <br />LIGHT OVER THE ENTIRE SURFACE OF THE BUTTON. <br />1124A.5 MINIMUM ILLUMINATION. THE MINIMUM ILLUMINATION AT THE CAR CONTROLS THRESHOLD AND THE LANDING <br />WHEN THE CAR AND LANDING DOORS ARE OPEN SHALL NOT BE LESS THAN 5 FOOT-CANDLES (54 LX). <br />1124A.6 HALL LANTERN. A VISUAL AND AUDIBLE SIGNAL SHALL BE PROVIDED AT EACH HOISTWAY ENTRANCE INDICATING <br />TO THE PROSPECTIVE PASSENGER THE CAR ANSWERING THE CALL AND ITS DIRECTION OF TRAVEL AS <br />FOLLOWS: <br />1. THE VISUAL SIGNAL FOR EACH DIRECTION SHALL BE A MINIMUM OF 2-1/2 INCHES (63.5 MM) HIGH BY 2-1/2 <br />INCHES (63.5 MM) WIDE, AND VISIBLE FROM THE PROXIMITY OF THE HALL CALL BUTTON. <br />2. THE AUDIBLE SIGNAL SHALL SOUND ONCE FOR THE "UP" DIRECTION AND TWICE FOR THE "DOWN" DIRECTION <br />OR OF A CONFIGURATION WHICH DISTINGUISHES BETWEEN UP AND DOWN ELEVATOR TRAVEL. <br />3. THE CENTER LINE OF THE FIXTURE SHALL BE LOCATED A MINIMUM OF6FEET (1829 MM) IN HEIGHT FROM THE <br />LOBBY FLOOR. <br />4. THE USE OF IN-CAR LANTERNS, LOCATED IN OR ON THE CAR DOORJAMBS, VISIBLE FROM THE PROXIMITY OF <br />THE HALL CALL BUTTONS AND CONFORMING TO THE ABOVE REQUIREMENTS OF THIS SECTION SHALL OR <br />WILL BE ACCEPTABLE. <br />THE USE OF ARROW SHAPES ARE PREFERRED FOR VISIBLE SIGNALS. <br />1124A.7 DOOR DELAY. <br />1124A.7.1 HALL CALL. THE MINIMUM ACCEPTABLE TIME FROM NOTIFICATION THAT A CAR IS ANSWERING A CALL (LANTERN <br />AND AUDIBLE SIGNAL) UNTIL THE DOORS OF THE CAR START TO CLOSE SHALL BE CALCULATED BY THE <br />FOLLOWING EQUATIONS BUT SHALL BE NO LESS THAN 5 SECONDS: <br />T = D / (1.5 ft/s) OR T = D / (445 mm/s) <br />WHERE 'T' IS THE TOTAL TIME IN SECONDS AND 'D' IS THE DISTANCE FROM A POINT IN THE LOBBY OR <br />LANDING AREA 60 INCHES (1524 MM) DIRECTLY IN FRONT OF THE FARTHEST CALL BUTTON CONTROLLING THAT <br />CAR TO THE CENTERLINE OF ITS HOISTWAY DOOR (SEE FIGURE 11A-7D ). FOR CARS WITH IN-CAR LANTERNS, 'T' <br />BEGINS WHEN THE LANTERN IS VISIBLE FROM THE VICINITY OF HALL CALL BUTTONS AND AN AUDIBLE SIGNAL IS <br />SOUNDED. <br />1124A.7.2 DOOR DELAY FOR CAR CALLS. THE MINIMUM ACCEPTABLE TIME FOR THE DOOR TO REMAIN FULLY OPEN AFTER <br />RECEIVING A CALL SHALL NOT BE LESS THAN 5 SECONDS. <br />1124A.8 DOOR JAMB MARKING. THE FLOOR LEVEL AT ALL ELEVATOR HOISTWAY ENTRANCES SHALL BE DESIGNATED BY <br />RAISED CHARACTERS PROVIDED ON BOTH JAMBS. CHARACTERS SHALL BE 2 INCHES (50.8 MM) IN HEIGHT <br />LOCATED WITH THE CENTERLINE 60 INCHES ( 1524 MM) FROM THE FLOOR. ON THE MAIN ENTRY LEVEL, A RAISED <br />FIVE POINTED STAR SHALL BE PLACED TO THE LEFT OF THE RAISED CHARACTER. THE OUTSIDE DIAMETER OF <br />THE STAR SHALL BE 2 INCHES (50.8 MM) AND ALL POINTS SHALL BE OF EQUAL LENGTH. THE RAISED <br />CHARACTERS AND THE STAR SHALL BE WHITE ON A BLACK BACKGROUND. CONTRACTED GRADE 2 BRAILLE, <br />CONFORMING TO SECTION 1143A.7 (see detail XX / XXX), SHALL BE PLACED BELOW THE CORRESPONDING RAISED <br />CHARACTERS AND THE STAR. THE BRAILLE TRANSLATION FOR THE STAR SHALL STATE "MAIN". THE RAISED <br />CHARACTERS SHALL COMPLY WITH SECTION 1143A.6. (SEE FIGURE 11A-7C.) <br />1124A.9 DOOR PROTECTIVE AND REOPENING DEVICES. DOORS CLOSED BY AUTOMATIC MEANS SHALL BE PROVIDED <br />WITH A DOOR REOPENING DEVICE THAT WILL FUNCTION TO STOP AND REOPEN A CAR DOOR AND ADJACENT <br />HOISTWAY DOOR IN CASE THE CAR DOOR IS OBSTRUCTED WHILE CLOSING. THIS REOPENING DEVICE SHALL <br />ALSO BE CAPABLE OF SENSING AN OBJECT OR PERSON IN THE PATH OF A CLOSING DOOR WITHOUT REQUIRING <br />CONTACT FOR ACTIVATION AT A NOMINAL 5 INCHES AND 29 INCHES (127 MM AND 737 MM) ABOVE THE FLOOR. <br />DOOR-REOPENING DEVICES SHALL REMAIN EFFECTIVE FOR A PERIOD OF NOT LESS THAN 20 SECONDS. AFTER <br />SUCH AN INTERVAL, THE DOORS MAY CLOSE IN ACCORDANCE WITH THE REQUIREMENTS OF ASME A17.1. <br />1124A.10 OPERATION AND LEVELING. THE ELEVATOR SHALL BE AUTOMATIC AND BE PROVIDED WITH A SELF-LEVELING <br />FEATURE THAT WILL AUTOMATICALLY BRING THE CAR TO THE FLOOR LANDINGS WITHIN A TOLERANCE OF PLUS <br />OR MINUS 1/2 INCH (12.7 MM) UNDER RATED LOADING TO ZERO LOADING CONDITIONS. THIS SELF-LEVELING <br />SHALL, WITHIN ITS ZONE, BE ENTIRELY AUTOMATIC AND INDEPENDENT OF THE OPERATING DEVICE AND SHALL <br />CORRECT THE OVER TRAVEL OR UNDER TRAVEL. THE CAR SHALL ALSO BE MAINTAINED APPROXIMATELY LEVEL <br />WITH THE LANDING, IRRESPECTIVE OF LOAD. THE CLEARANCE BETWEEN THE CAR PLATFORM SILL AND THE <br />EDGE OF THE HOISTWAY LANDING SHALL BE NO GREATER THAN 1 1/4 INCHES (31.75 MM). <br />1124A.11 PLATFORM (WHEELCHAIR) LIFTS. <br />1124A.11.1 GENERAL. PLATFORM (WHEELCHAIR) LIFTS MAY BE PROVIDED BETWEEN LEVELS, IN LIEU OF PASSENGER <br />ELEVATORS, WHEN THE VERTICAL DISTANCE BETWEEN LANDINGS, AS WELL AS THE STRUCTURAL DESIGN AND <br />SAFEGUARDS ARE AS ALLOWED BY ASME A18.1, "SAFETY STANDARD FOR PLATFORM LIFTS AND STAIRWAY <br />CHAIR LIFTS;" THE STATE OF CALIFORNIA, DEPARTMENT OF INDUSTRIAL RELATIONS, DIVISION OF <br />OCCUPATIONAL SAFETY AND HEALTH (TITLE 8 "ELEVATOR SAFETY ORDERS") AND ANY APPLICABLE SAFETY <br />REGULATIONS OF OTHER ADMINISTRATIVE AUTHORITIES HAVING JURISDICTION. IF LIFTS ARE PROVIDED, THEY <br />SHALL BE DESIGNED AND CONSTRUCTED TO FACILITATE UNASSISTED ENTRY, OPERATION AND EXIT FROM THE <br />LIFT, AND SHALL COMPLY WITH RESTRICTIONS AND ENHANCEMENTS OF THIS SECTION IN CONJUNCTION WITH <br />TITLE 8 OF THE CALIFORNIA CODE OF REGULATIONS. <br />1124A.11.2 SIZE AND CLEAR FLOOR SPACE. PLATFORM (WHEELCHAIR)LIFTS SHALL BE OF SUFFICIENT SIZE TO <br />ACCOMMODATE A WHEELCHAIR IN ACCORDANCE WITH SECTION 1138A.1.4 (see detail XX / XXX). <br />1124A.11.3 LIFT ACCESS. THERE SHALL BE A LEVEL AND CLEAR FLOOR AREA OR LANDING AT EACH FLOOR OR LEVEL <br />SERVED BY PLATFORM(WHEELCHAIR) LIFTS. CLEAR FLOOR AREAS OR LANDINGS SHALL MEET THE APPLICABLE <br />"ACCESSIBLE ROUTE" REQUIREMENTS. <br />1124A.11.4 STANDBY POWER. TO ENSURE CONTINUED OPERATION IN CASE OF PRIMARY POWER LOSS, PLATFORM <br />(WHEELCHAIR) LIFTS SHALL BE PROVIDED WITH STANDBY POWER OR WITH SELF RECHARGEABLE BATTERY <br />POWER THAT PROVIDES SUFFICIENT POWER TO OPERATE ALL PLATFORM LIFT FUNCTIONS FOR A MINIMUM OF <br />FIVE UPWARD AND DOWNWARD TRIPS. <br />1124A.11.5 OPENNESS. PLATFORM (WHEELCHAIR) LIFTS ON AN ACCESSIBLE MEANS OF EGRESS SHALL NOT BE INSTALLED IN <br />A FULLY ENCLOSED HOISTWAY. <br />1124A.11.6 DOORS AND GATES. LIFTS SHALL HAVE LOW ENERGY POWER-OPERATED DOORS OR GATES, WHICH SHALL <br />REMAIN OPEN FOR 20 SECONDS MINIMUM. END DOORS SHALL HAVE 32 INCHES (813 MM) MINIMUM CLEAR <br />OPENING WIDTH. SIDE DOORS CLEAR OPENING WIDTH SHALL BE 42 INCHES (1067 MM) MINIMUM. <br />EXCEPTION:LIFTS HAVING DOORS OR GATES ON OPPOSITE SIDES SHALL BE PERMITTED TO HAVE SELF-CLOSING MANUAL <br />DOORS OR GATES. <br />1124A.11. 7 RESTRICTION SIGN. A SIGN COMPLYING WITH SECTION 1143A (see detail XX / XXX) SHALL BE SECURELY FASTENED <br />IN A CONSPICUOUS PLACE AT EACH LANDING AND ON THE PLATFORM. THE SIGN SHALL STATE "NO FREIGHT" IN <br />LETTERS NOT LESS THAN 5/8 INCH (16 MM) HIGH AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY. <br />5'-8" MIN <br />3'-0" MIN <br />4' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />(b) <br />side opening door <br />6'-8" MIN <br />3'-6" MIN <br />(a) <br />center opening door FIGURE 11A-7A <br />MINIMUM DIMENSIONS FOR ELEVATOR CARS <br />4' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />4' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />4' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />65 <br />43 <br />21 <br />BS <br />X <br />5/ <br />8 <br />" <br />MI <br />N <br />3/4" <br />MIN button diameter <br />min separation <br />characters and <br />symbols height <br />place star <br />alongside main <br />exit floor number <br />3/ <br />8 <br />" <br />MI <br />N <br />℄ <br />35 <br />" <br /> <br />M <br />I <br />N <br />AB <br />O <br />V <br />E <br /> <br />F <br />L <br />O <br />O <br />R <br />CLOSEOPEN <br />STOPALARM <br />FIGURE 11A-7A <br />MINIMUM DIMENSIONS FOR ELEVATOR CARS <br />(b) <br />maximum installation heights above cab floor <br />(a) <br />elevator control panel detail <br />2' <br />- <br />1 <br />1 <br />" <br /> <br />M <br />I <br />N <br />48 <br />" <br /> <br />M <br />A <br />X <br /> <br />F <br />O <br />R <br /> <br />F <br />R <br />O <br />N <br />T <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />54 <br />" <br /> <br />M <br />A <br />X <br /> <br />F <br />O <br />R <br /> <br />S <br />I <br />D <br />E <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />2' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />℄ <br />℄ <br />℄ <br />rail <br />control panel <br />see (a) <br />1 1/2" <br />MIN <br />FIGURE 11A-7D <br />GRAPH OF TIMING EQUATION <br />DISTANCE IN FEET <br />ACCEPTABLE <br />'T <br />' <br /> <br />T <br />I <br />M <br />E <br /> <br />I <br />N <br /> <br />S <br />E <br />C <br />O <br />N <br />D <br />S <br />UN <br />A <br />C <br />C <br />E <br />P <br />T <br />A <br />B <br />L <br />E <br />5 6 8 10 12 14 16 18 <br />6 <br />5 <br />4 <br />3 <br />2 <br />1 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />0 <br />FIGURE 11A-7C <br />HOISTWAY AND ELEVATOR ENTRANCES <br />1 <br />3'-6 <br />" <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />5 <br />' <br />- <br />0 <br />" <br />6'-0 <br />" <br />℄ <br />℄ <br />℄ <br /> <br /> <br />2 <br />' <br />- <br />5 <br />" <br /> <br />5 <br />" <br />B <br />A <br />floor landing <br />numbers on both <br />sides of door jamb <br />call button <br />hall lantern <br />NOTE: The automatic door reopening device is activated if an object passes through either line A or line B. Line A and line <br />B represent the vertical location of the door reopening devise not requiring contact. <br />1«2" <br /> <br />M <br />I <br />N <br />2" MIN <br />SECTION 3002.4 ELEVATOR CAR TO ACCOMMODATE AMBULANCE STRETCHER <br />3002.4a GENERAL STRETCHER REQUIREMENTS. ALL BUILDINGS AND STRUCTURES WITH ONE OR MORE PASSENGER ELEVATORS SHALL BE <br />PROVIDED WITH NOT LESS THAN ONE MEDICAL EMERGENCY SERVICE ELEVATOR TO ALL LANDINGS MEETING THE PROVISIONS OF <br />SECTION 3002.4a. <br />EXCEPTIONS: <br />1.ELEVATORS IN STRUCTURES USED ONLY BY MAINTENANCE AND OPERATION PERSONNEL. <br />2.ELEVATORS IN JAILS AND PENAL INSTITUTIONS. <br />3.ELEVATORS IN BUILDINGS OR STRUCTURES WHERE EACH LANDING IS AT GROUND LEVEL OR IS ACCESSIBLE AT GRADE LEVEL OR <br />BY A RAMP. <br />4.ELEVATOR(S) IN TWO-STORY BUILDINGS OR STRUCTURES EQUIPPED WITH STAIRS OF A CONFIGURATION THAT WILL <br />ACCOMMODATE THE CARRYING OF THE GURNEY OR STRETCHER AS PERMITTED BY THE LOCAL JURISDICTIONAL AUTHORITY. <br />5.ELEVATORS IN BUILDING OR STRUCTURES LESS THEN FOUR STORIES IN HEIGHT FOR WHICH THE THE LOCAL JURISDICTIONAL <br />AUTHORITY HAS GRANTED AN EXCEPTION IN THE FORM OF A WRITTEN DOCUMENT. <br />3002.4.1a GURNEY SIZE. THE MEDICAL EMERGENCY SERVICE ELEVATOR SHALL ACCOMMODATE THE LOADING AND TRANSPORT OF AN <br />AMBULANCE GURNEY OR STRETCHER [MAXIMUM SIZE 24 INCHES BY 84 INCHES (610 MM BY 2134 MM) WITH NOT LESS THAN 5-INCH <br />(127MM) RADIUS CORNERS] IN THE HORIZONTAL POSITION. <br />3002.4.2a HOISTWAY DOORS, THE HOISTWAY LANDING OPENINGS SHALL BE PROVIDED WITH POWER-OPERATED DOORS. <br />3002.4.3a ELEVATOR ENTRANCE OPENING AND CAR SIZE. THE ELEVATOR CAR SHALL BE OF SUCH A SIZE AND ARRANGEMENT TO <br />ACCOMMODATE A 24 INCHES BY 84 INCHES (610 MM BY 2134 MM)AMBULANCE GURNEY OR STRETCHER WITH NOT LESS THAN <br />5-INCH (127MM) RADIUS CORNERS, IN THE HORIZONTAL, OPEN POSITION, SHALL BE PROVIDED WITH A MINIMUM CLEAR DISTANCE <br />BETWEEN WALLS OR BETWEEN WALLS AND DOOR EXCLUDING RETURN PANELS NOT LESS THAN 80INCHES BY 54 INCHES (2032 MM <br />BY 1372 MM), AND A MINIMUM DISTANCE FROM WALL AND RETURN PANEL NOT LESS THAN 51 INCHES(1295 MM) WITH A 42 INCH <br />(1067 MM) SIDE SLIDE DOOR. <br />EXCEPTION:THE ELEVATOR CAR DIMENSIONS AND/OR THE CLEAR ENTRANCE OPENING DIMENSIONS MAY BE ALTERED WHERE IT CAN BE <br />DEMONSTRATED TO THE LOCAL JURISDICTIONAL AUTHORITY'S SATISFACTION THAT THE PROPOSED CONFIGURATION WILL <br />HANDEL THE DESIGNATED GURNEY OR STRETCHER WITH EQUIVALENT EASE. DOCUMENTATION FROM THE LOCAL AUTHORITY <br />SHALL BE PROVIDED TO THE OCCUPATIONAL SAFETY AND HEALTH STANDARDS BOARD. <br />3002.4.4a ELEVATOR RECALL. THE ELEVATOR(S) DESIGNATED THE MEDICAL EMERGENCY ELEVATOR SHALL BE EQUIPPED WITH A KEY <br />SWITCH TO RECALL THE ELEVATOR NONSTOP TO THE MAIN FLOOR. FOR THE PURPOSE OF THIS SECTION, ELEVATORS IN <br />COMPLIANCE WITH SECTION 3002.2 SHALL BE ACCEPTABLE. <br />3002.4.5a DESIGNATION. MEDICAL EMERGENCY ELEVATORS SHALL BE IDENTIFIED BY THE INTERNATIONAL (STAR OR LIFE) FOR EMERGENCY <br />MEDICAL SERVICES. <br />3002.4.6a SYMBOL SIZE. THE SYMBOL SHALL NOT BE LESS THAN 3 INCHES (76 MM) IN SIZE. <br />3002.4.7a SYMBOL LOCATION. A SYMBOL SHALL BE PERMANENTLY ATTACHED TO EACH SIDE OF THE HOISTWAY DOOR FRAME ON THE <br />PORTION OF THE FRAME AT RIGHT ANGLES TO THE HALLWAY OR LANDING AREA. EACH SYMBOL SHALL NOT BE LESS THAN 78 <br />INCHES (1981 MM) AND NOT MORE THAN 84 INCHES (2134 MM) ABOVE THE FLOOR LEVEL AT THE THRESHOLD. <br />SEE CBC CHAPTER 30, ELEVATORS AND CONVEYING SYSTEMS, FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE. <br />SEC. 1125A HAZARDS ON ACCESSIBLE ROUTES - <br />SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES <br />1125A.1 WARNING CURBS. ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES (101.6 MM) IN VERTICAL DIMENSION, <br />SUCH AS CHANGES IN LEVEL AT PLANTERS OR FOUNTAINS LOCATED IN OR ADJACENT TO WALKS, HALLS, <br />CORRIDORS, PASSAGEWAYS, AISLES, PEDESTRIAN WAYS AND OTHER CIRCULATION SPACES SHALL BE <br />IDENTIFIED BY CURBS PROJECTING AT LEAST 6 INCHES (152.4 MM) IN HEIGHT ABOVE THE WALK OR <br />SIDEWALK SURFACE TO WARN THE BLIND OF A POTENTIAL DROP-OFF <br />EXCEPTION:WHEN A GUARDRAIL OR HANDRAIL IS PROVIDED WITH EDGE PROTECTION IN ACCORDANCE WITH CBC <br />SECTION 1010.10.1. <br />1125A.2 HEADROOM CLEARANCE. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES, PEDESTRIAN WAYS AND <br />OTHER CIRCULATION SPACES WHICH ARE PART OF THE REQUIRED EGRESS SYSTEM SHALL HAVE A <br />MINIMUM CLEAR HEADROOM AS REQUIRED IN CBC SECTION 1003.2. OTHER WALKS, PEDESTRIAN WAYS <br />AND CIRCULATION SPACES SHALL HAVE A MINIMUM CLEAR HEADROOM OF 80 INCHES (2032 MM). IF THE <br />VERTICAL CLEARANCE OF AN AREA ADJOINING AN ACCESSIBLE ROUTE IS REDUCED TO LESS THAN 80 <br />INCHES (2032 MM) NOMINAL DIMENSION, A GUARDRAIL OR OTHER BARRIER HAVING ITS LEADING EDGE AT <br />OR BELOW 27 INCHES (686 MM) ABOVE THE FINISHED FLOOR SHALL BE PROVIDED. <br />6" <br />MI <br />N <br />HI <br />G <br />H <br />to suit <br />design <br />GUIDE CURB DETAIL <br />> <br />4 <br />" <br />abrupt change in level <br />EGRESS HEADROOM CLEARANCE <br />2' <br />- <br />3 <br />" <br /> <br />M <br />A <br />X <br />X <br />< <br /> <br />6 <br />' <br />- <br />8 <br />" <br />guard or barrier <br />rail <br />FIGURE 11A-1B <br />HEADROOM CLEARANCE AND OVERHANGING PROJECTION <br />6' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />ov <br />e <br />r <br />h <br />a <br />n <br />g <br />i <br />n <br />g <br /> <br />o <br />b <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br />7' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />he <br />a <br />d <br />r <br />o <br />o <br />m <br /> <br />c <br />l <br />e <br />a <br />r <br />a <br />n <br />c <br />e <br />3 1 <br />2