32
<br />2
<br />
<br />N
<br />.
<br />
<br />H
<br />A
<br />R
<br />B
<br />O
<br />R
<br />
<br />
<br />B
<br />L
<br />V
<br />D
<br />.
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />3
<br />SHEET NUMBER
<br />2 0 2 4 0 1 0
<br />SHEET TITLE
<br />PROJECT NUMBER
<br />REVISIONS
<br />NO.DATE NO.DATE
<br />HANNOUCHE ARCHITECTS
<br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT
<br />AND OTHER PROPERTY RIGHTS INHERENT IN
<br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES,
<br />FIELD NOTES AND ASSOCIATED DOCUMENTS
<br />ARE INSTRUMENTS OF SERVICE AND ARE THE
<br />PROPERTY OF HANNOUCHE ARCHITECTS.
<br />ALL INFORMATION CONTAINED IN THESE DRAWINGS,
<br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED
<br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT
<br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED,
<br />OR USED OTHERWISE IN ANY FORM OR MANNER
<br />WHATSOEVER, WITHOUT FIRST OBTAINING THE
<br />EXPRESSED WRITTEN PERMISSION AND CONSENT
<br />OF HANNOUCHE ARCHITECTS.
<br />HANNOUCHE ARCHITECT c 2021
<br />HANNOUCHE
<br />ARCHITECTS
<br />949.261.2070
<br />SAMIR HANNOUCHE, ARCHITECT
<br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660
<br />May 9, 2025
<br />1 CORR
<br />12/10/24
<br />BLDG
<br />A CORR
<br />3/18/25
<br />OCFA
<br />2 CORR
<br />4/09/25
<br />BLDG
<br />DATE SIGNED2
<br />3 CORR
<br />5/09/25
<br />BLDG
<br />A0.19
<br />DWELLING ADA
<br />NOTES DETAILS
<br />SCALE: N/A
<br />SEC. 1143A SIGNAGE -
<br />SECTION 1143A SIGNAGE
<br />1143A.1 GENERAL. WHEN SIGNS AND/OR IDENTIFICATION DEVICES ARE PROVIDED THEY SHALL COMPLY WITH THIS
<br />SECTION. WHEN BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED, EITHER ONE SIGN WITH BOTH
<br />VISUAL AND TACTILE CHARACTERS, OR TWO SEPARATE SIGNS ONE WITH VISUAL, AND ONE WITH TACTILE
<br />CHARACTERS, SHALL BE PROVIDED.
<br />EXCEPTION:SIGNS NEED NOT BE PROVIDED WITHIN DWELLING UNITS.
<br />NOTE:SEE SECTION 1127A.7 (see detail XX / XXX) FOR ADDITIONAL SIGNAGE REQUIREMENTS APPLICABLE TO SANITARY
<br />FACILITIES, AND SECTION 1124A (see detail XX / XXX) FOR ADDITIONAL SIGNAGE REQUIREMENTS APPLICABLE TO
<br />ELEVATORS.
<br />1143A.2 IDENTIFICATION SIGNS. WHEN SIGNS IDENTIFY PERMANENT ROOMS AND SPACES OF A BUILDING OR SITE, THEY
<br />SHALL COMPLY WITH SECTIONS 1143A.J, JJ43A.5, 1143A.6 AND 1143A.7.
<br />EXCEPTION:EXTERIOR SIGNS THAT ARE NOT LOCATED AT THE DOOR TO THE SPACE THEY SERVE SHALL NOT BE REQUIRED
<br />TO COMPLY WITH SECTION 1143A.6.
<br />1143A.3 DIRECTIONAL AND INFORMATIONAL SIGNS. WHEN SIGNS DIRECT TO OR GIVE INFORMATION ABOUT PERMANENT
<br />ROOMS AND SPACES OF A BUILDING OR SITE, THEY SHALL COMPLY WITH SECTIONS 1143A.5.
<br />1143A.4 ACCESSIBILITY SIGNS. WHEN SIGNS IDENTIFY, DIRECT OR GIVE INFORMATION ABOUT ACCESSIBLE ELEMENTS
<br />AND FEATURES OF A BUILDING OR SITE, THEY SHALL INCLUDE THE APPROPRIATE SYMBOL OF ACCESSIBILITY
<br />AND SHALL COMPLY WITH SECTION 1143A.5.
<br />1143A.5 VISUAL CHARACTERS. SIGNS WITH VISUAL CHARACTERS SHALL COMPLY WITH THIS SECTION.
<br />1. FINISH AND CONTRAST. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH.
<br />CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT ON A DARK BACKGROUND OR
<br />DARK ON A LIGHT BACKGROUND.
<br />2. CHARACTER TYPE. CHARACTERS SHALL BE UPPERCASE, LOWERCASE OR A COMBINATION OF BOTH.
<br />CHARACTERS SHALL BE CONVENTIONAL IN FORM, AND SHALL NOT BE ITALIC, OBLIQUE, SCRIPT, HIGHLY
<br />DECORATIVE, OR OF OTHER UNUSUAL FORMS.
<br />3. PROPORTIONS. CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE THE WIDTH OF THE
<br />UPPERCASE LETTER "0" IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF THE
<br />UPPERCASE LETTER " I ".
<br />4. CHARACTER HEIGHT. VISUAL CHARACTERS SHALL BE SIZED IN ACCORDANCE WITH TABLE 1143A.5. VIEWING
<br />DISTANCE SHALL BE MEASURED AS THE HORIZONTAL DISTANCE BETWEEN THE CHARACTER AND AN
<br />OBSTRUCTION PREVENTING FURTHER APPROACH TOWARDS THE SIGN. CHARACTER HEIGHT SHALL BE
<br />BASED ON THE UPPERCASE LETTER " I ".
<br />5. HEIGHT FROM FINISH FLR. VISUAL CHARACTERS SHALL BE 40 INCHES (1016 MM) MIN. ABOVE THE FINISH
<br />FLOOR.
<br />EXCEPTIONS:
<br />1. VISUAL CHARACTERS INDICATING ELEVATOR CAR CONTROLS.
<br />2. FLOOR-LEVEL EXIT SIGNS COMPLYING WITH CHAPTER 10, SECTION 1011.6.
<br />6. STROKE THICKNESS. STROKE THICKNESS OF THE UPPERCASE LETTER " I " SHALL BE 10 PERCENT MINIMUM
<br />AND 20 PERCENT MAXIMUM OF THE HEIGHT OF THE CHARACTER.
<br />7. CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS
<br />OF ADJACENT CHARACTERS,EXCLUDING WORD SPACES. SPACING BETWEEN INDIVIDUAL CHARACTERS
<br />SHALL BE 10 PERCENT MINIMUM AND 35 PERCENT MAXIMUM OF CHARACTER HEIGHT.
<br />8. LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF CHARACTERS WITHIN A
<br />MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE CHARACTER HEIGHT.
<br />9. CHARACTER FORMAT. TEXT SHALL BE IN A HORIZONTAL FORMAT.
<br /> 1143A.6 RAISED CHARACTERS AND PICTORIAL SYMBOL SIGNS. WHEN RAISED CHARACTERS ARE REQUIRED OR WHEN
<br />PICTORIAL SYMBOLS (PICTOGRAMS) ARE USED ON SUCH SIGNS, THEY SHALL COMPLY WITH THIS SECTION.
<br />RAISED CHARACTERS AND PICTORIAL SYMBOLS SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION
<br />1143A.7.
<br />1. CHARACTER TYPE. RAISED CHARACTERS ON SIGNS SHALL BE 1/32 INCH (0.8 MM) MINIMUM ABOVE THEIR
<br />BACKGROUND. CHARACTERS SHALL BE SANS SERIF UPPERCASE, AND SHALL NOT BE ITALIC, OBLIQUE,
<br />SCRIPT, HIGHLY DECORATIVE, OR OF OTHER UNUSUAL FORMS.
<br />2. CHARACTER HEIGHT. CHARACTER HEIGHT MEASURED VERTICALLY FROM THE BASELINE OF THE
<br />CHARACTER SHALL BE 5/8 INCH (15.9 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUM BASED ON THE HEIGHT
<br />OF THE UPPERCASE LETTER " I ".
<br />3. CHARACTER FORMAT. CHARACTERS AND BRAILLE SHALL BE IN A HORIZONTAL FORMAT.
<br />4. PROPORTIONS. RAISED CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHEN THE WIDTH OF
<br />THE UPPERCASE LETTER " O " IS 60 PERCENT MINIMUM AND 110 PERCENT MAXIMUM OF THE HEIGHT OF
<br />THE UPPERCASE LETTER " I ".
<br />5. STROKE THICKNESS. STROKE THICKNESS OF THE UPPERCASE LETTER " I " SHALL BE 15 PERCENT MAXIMUM
<br />OF THE HEIGHT OF THE CHARACTER.
<br />6. CHARACTER SPACING. CHARACTER SPACING SHALL BE MEASURED BETWEEN THE TWO CLOSEST POINTS
<br />OF ADJACENT RAISED CHARACTERS WITHIN A MESSAGE, EXCLUDING WORD SPACES. WHEN CHARACTERS
<br />HAVE RECTANGULAR CROSS SECTIONS,SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL BE 1/8
<br />INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM. WHEN
<br />CHARACTERS HAVE OTHER CROSS SECTIONS, SPACING BETWEEN INDIVIDUAL RAISED CHARACTERS SHALL
<br />BE 1/16 INCH (1.6 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER STROKE WIDTH MAXIMUM AT THE
<br />BASE OF THE CROSS SECTIONS, AND 1/8 INCH (3.2 MM) MINIMUM AND 4 TIMES THE RAISED CHARACTER
<br />STROKE WIDTH MAXIMUM AT THE TOP OF THE CROSS SECTIONS. CHARACTERS SHALL BE SEPARATED
<br />FROM RAISED BORDERS AND DECORATIVE ELEMENTS 3/8 INCH (9.5 MM) MINIMUM.
<br />7.LINE SPACING. SPACING BETWEEN THE BASELINES OF SEPARATE LINES OF RAISED CHARACTERS WITHIN A
<br />MESSAGE SHALL BE 135 PERCENT MINIMUM AND 170 PERCENT MAXIMUM OF THE RAISED CHARACTER
<br />HEIGHT.
<br />8.LOCATION. WHEN A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN SHALL BE LOCATED ALONGSIDE THE
<br />DOOR AT THE LATCH SIDE. WHEN A TACTILE SIGN IS PROVIDED AT DOUBLE DOORS WITH ONE ACTIVE LEAF,
<br />THE SIGN SHALL BE LOCATED ON THE INACTIVE LEAF. WHEN A TACTILE SIGN IS PROVIDED AT DOUBLE
<br />DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR.
<br />WHEN THERE IS NO WALL SPACE AT THE LATCH SIDE OF A SINGLE DOOR OR AT THE RIGHT SIDE OF
<br />DOUBLE DOORS, SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT WALL. SIGNS CONTAINING
<br />TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR FLOOR SPACE OF 18 INCHES (457 MM)
<br />MINIMUM BY 18 INCHES (457 MM) MINIMUM, CENTERED ON THE TACTILE CHARACTERS, IS PROVIDED
<br />BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION.
<br />WHEN PERMANENT IDENTIFICATION SIGNAGE IS PROVIDED FOR ROOMS AND SPACES THEY SHALL BE
<br />LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE ENTERS THE ROOM OR SPACE. SIGNS THAT
<br />IDENTIFY EXITS SHALL BE LOCATED ON THE APPROACH SIDE OF THE DOOR AS ONE EXITS THE ROOM OR
<br />SPACE.
<br />9. HEIGHT. SIGNS WITH RAISED CHARACTERS SHALL BE LOCATED 48 INCHES (1219 MM) MINIMUM ABOVE THE
<br />FINISH FLOOR, MEASURED FROM THE BASELINE OF THE LOWEST BRAILLE CELLS AND 60 INCHES (1524 MM)
<br />MAXIMUM ABOVE THE FINISH FLOOR, MEASURED FROM THE BASELINE OF THE HIGHEST LINE OF RAISED
<br />CHARACTERS.
<br />EXCEPTION:
<br />TACTILE CHARACTERS FOR ELEVATOR CAR CONTROLS SHALL NOT BE REQUIRED TO COMPLY WITH
<br />THIS SECTION.
<br />10.PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE
<br />ACCOMPANIED BY A TEXT DESCRIPTION LOCATED DIRECTLY BELOW THE PICTOGRAM FIELD. THE TEXT
<br />DESCRIPTION SHALL COMPLY WITH SECTIONS 1143A.6 AND 1143A.7. THE OUTSIDE DIMENSION OF THE
<br />PICTOGRAM FIELD SHALL BE A MINIMUM OF 6 INCHES (152 MM) IN HEIGHT. CHARACTERS AND BRAILLE
<br />SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD.
<br />1143A.7 BRAILLE. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN OTHER
<br />PORTIONS OF THESE STANDARDS.
<br />1143A.7.1 DIMENSIONS AND CAPITALIZATION. BRAILLE DOTS SHALL HAVE A DOMED OR ROUNDED SHAPE AND SHALL
<br />COMPLY WITH TABLE 1143A.7.1. THE INDICATION OF AN UPPERCASE LETTER OR LETTERS SHALL ONLY BE USED
<br />BEFORE THE FIRST WORD OF SENTENCES, PROPER NOUNS AND NAMES, INDIVIDUAL LETTERS OF THE
<br />ALPHABET, INITIALS, AND ACRONYMS.
<br />1. Measured center to center
<br />1143A.7.2 POSITION. BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT IN A HORIZONTAL FORMAT,
<br />FLUSH LEFT OR CENTERED. IF TEXT IS MULTI-LINED, BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT.
<br />BRAILLE SHALL BE SEPARATED 3 INCH (9.5 MM) MINIMUM AND 1/2 INCH (12.7 MM) MAXIMUM FROM ANY OTHER
<br />TACTILE CHARACTERS AND 3/8 INCH (9.5 MM) MINIMUM FROM RAISED BORDERS AND DECORATIVE ELEMENTS.
<br />EXCEPTION:BRAILLE PROVIDED ON ELEVATOR CAR CONTROLS SHALL BE SEPARATED 3116 INCH (4.8 MM) MINIMUM AND
<br />SHALL BE LOCATED DIRECTLY BELOW THE CORRESPONDING RAISED CHARACTERS OR SYMBOLS.
<br />1143A.8 SYMBOLS OF ACCESSIBILITY. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUND SHALL HAVE A NON-GLARE
<br />FINISH. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUND WITH EITHER A LIGHT
<br />SYMBOL ON A DARK BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND. SYMBOLS OF
<br />ACCESSIBILITY SHALL COMPLY WITH THE FOLLOWING:
<br />1. INTERNATIONAL SYMBOL OF ACCESSIBILITY. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL
<br />CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND. THE BLUE SHALL BE COLOR NO. 15090 IN FEDERAL
<br />STANDARD 595B. (SEE FIGURE 11A-1A.)
<br />2. INTERNATIONAL SYMBOL OF TTY. (SEE FIGURE 11A-11C; detail XX this sheet)
<br />3. VOLUME CONTROL TELEPHONES. (SEE FIGURE 11A-11D; detail XX this sheet)
<br />4. ASSISTIVE LISTENING SYSTEMS. (SEE FIGURE 11A-11E; detail XX this sheet)
<br />5. CLEANER AIR SYMBOL. (SEE CHAPTER 11B; see detail X / XXX)
<br />6. TOILET AND BATHING FACILITIES GEOMETRIC SYMBOLS. (SEE SECTION 1127A.7; see detail X / XXX)
<br />TABLE 1143A.5 VISUAL CHARACTER HEIGHT
<br />HEIGHT TO FINISH FLOOR OR GROUND
<br />FROM BASELINE OF CHARACTER
<br />HORIZONTAL VIEWING
<br />DISTANCE MINIMUM CHARACTER HEIGHT
<br />40 INCHES (1016 MM) TO
<br />LESS THAN OR EQUAL TO 70
<br />INCHES (1778 MM)
<br />LESS THAN 72 INCHES
<br />(1829 MM)
<br />5 8 INCH (15.9 MM)
<br />72 INCHES (1829 MM) AND
<br />GREATER
<br />5 8 INCH (15.9 MM), PLUS 18 INCH (3.2 MM) PER
<br />FOOT (305 MM) OF VIEWING DISTANCE ABOVE
<br />72 INCHES (1829 MM)
<br />GREATER THAN 70 INCHES (1778 MM)
<br />TO LESS THAN OR EQUAL TO 120
<br />INCHES (3048 MM)
<br />LESS THAN 180 INCHES
<br />(4572 MM)
<br />2 INCHES (51 MM)
<br />180 INCHES (4572 MM) AND
<br />GREATER
<br />2 INCHES (51 MM), PLUS 18 INCH (3.2 MM) PER
<br />FOOT (305 MM) OF VIEWING DISTANCE ABOVE
<br />180 INCHES (4572 MM)
<br />GREATER THAN 120 INCHES (3048 MM)LESS THAN 21 FEET (6401
<br />MM)
<br />3 INCHES (76 MM)
<br />21 FEET (6401 MM) AND
<br />GREATER
<br />3 INCHES (76 MM), PLUS 18 INCH (3.2 MM) PER
<br />FOOT (305 MM) OF VIEWING DISTANCE ABOVE
<br />21 FEET (6401 MM)
<br />TABLE 1143A.7.1 BRAILLE DIMENSIONS
<br />MEASUREMENT RANGE MINIMUM IN INCHES MAXIMUM IN INCHES
<br />DOT BASE DIAMETER 0.059" (1.5 MM) TO 0.063" (1.6 MM)
<br />DISTANCE BETWEEN TWO DOTS IN THE SAME CELLS ¹0.100" (2.5 MM)
<br />DISTANCE BETWEEN CORRESPONDING DOTS IN
<br />ADJACENT CELLS ¹
<br />0.300" (7.6 MM)
<br />DOT HEIGHT 0.025" (0.6 MM) TO 0.037" (0.9 MM)
<br />DISTANCE BETWEEN TWO CORRESPONDING DOTS
<br />FROM ONE CELL DIRECTLY BELOW ¹
<br />0.395" (10.0 MM) TO 0.400" (10.2 MM)
<br />FIGURE 11A-1A
<br />INTERNATIONAL ACCESSIBILITY SYMBOL
<br />(a)
<br />symbol proportions
<br />(b)
<br />display conditions
<br />SEC. 1124A ELEVATORS AND (WHEELCHAIR) PLATFORM LIFTS -
<br />SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
<br />1124A.1 GENERAL. ELEVATORS PROVIDED IN COVERED MULTIFAMILY BUILDINGS SHALL BE ACCESSIBLE. ELEVATORS
<br />REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THIS CHAPTER, ASME A17.1, SAFETY CODE FOR ELEVATORS
<br />AND ESCALATORS, TITLE 8, OF THE CALIFORNIA CODE OF REGULATIONS, UNDER "ELEVATOR SAFETY ORDERS,"
<br />AND ANY OTHER APPLICABLE SAFETY REGULATIONS OF OTHER ADMINISTRATIVE AUTHORITIES HAVING
<br />JURISDICTION.
<br />EXCEPTION:PRIVATE ELEVATORS SERVING ONLY ONE DWELLING UNIT.
<br />1124A.2 LOCATION. PASSENGER ELEVATORS SHALL BE LOCATED ON A MAJOR ACCESSIBLE ROUTE AND PROVISIONS
<br />SHALL BE MADE TO ENSURE THAT THEY REMAIN ACCESSIBLE AND USABLE AT ALL TIMES THAT THE BUILDING IS
<br />OCCUPIED.
<br />1124A.3 SIZE OF CAB AND CONTROL LOCATIONS.
<br />1124A.3.1 GENERAL. ELEVATORS SERVING COVERED MULTIFAMILY BUILDINGS SHALL BE SIZED TO ACCOMMODATE A
<br />WHEELCHAIR IN ACCORDANCE WITH THIS SECTION.
<br />EXCEPTION:WHEN THE ENFORCING AGENCY DETERMINES THAT COMPLIANCE WITH ANY REQUIREMENT OF THIS SECTION
<br />WOULD CREATE AN UNREASONABLE HARDSHIP, AN EXCEPTION TO THE REQUIREMENT SHALL BE GRANTED
<br />WHEN EQUIVALENT FACILITATION IS PROVIDED, AND WHERE IT CAN BE DEMONSTRATED THAT A PERSON USING
<br />A WHEELCHAIR CAN ENTER AND OPERATE THE ELEVATOR.
<br />1124A.3.2 CAR INSIDE. THE CAR INSIDE SHALL ALLOW FOR THE TURNING OF A WHEELCHAIR. THE MINIMUM CLEAR
<br />DISTANCE BETWEEN WALLS OR BETWEEN WALL AND DOOR, EXCLUDING RETURN PANELS, SHALL NOT BE LESS
<br />THAN 80 INCHES BY 54 INCHES (2032 MM BY 1372 MM) FOR CENTER-OPENING DOORS, AND 68 INCHES BY 54
<br />INCHES (1727 MM BY 1372 MM) FOR SIDE-SLIDE OPENING DOORS. (SEE FIGURE 11A-7A). MINIMUM DISTANCE FROM
<br />WALL TO RETURN PANEL SHALL NOT BE LESS THAN 51 INCHES (1295 MM).
<br />1124A.3.2.1 DOOR SIZE. ELEVATOR DOORS SHALL PROVIDE A MINIMUM CLEAR WIDTH OF 36 INCHES (914 MM).
<br />1124A.3.3 CAR CONTROLS.
<br />1124A.3.3.1 CAR CONTROL LOCATION. ELEVATOR FLOOR BUTTONS SHALL BE WITHIN 54 INCHES (1372 MM) ABOVE THE FINISH
<br />FLOOR FOR SIDE APPROACH AND 48 INCHES (1219 MM) FOR FRONT APPROACH. EXCEPT FOR PHOTOELECTRIC
<br />TUBE BYPASS SWITCHES, EMERGENCY CONTROLS, INCLUDING THE EMERGENCY STOP AND ALARM, SHALL BE
<br />GROUPED IN OR ADJACENT TO THE BOTTOM OF THE PANEL AND SHALL BE NO LOWER THAN 35 INCHES (889 MM)
<br />FROM THE FLOOR. FOR MULTIPLE CONTROLS ONLY, ONE SET MUST COMPLY WITH THESE HEIGHT
<br />REQUIREMENTS. FLOOR BUTTONS SHALL BE PROVIDED WITH VISUAL INDICATORS TO SHOW WHEN EACH CALL IS
<br />REGISTERED. THE VISUAL INDICATORS SHALL BE EXTINGUISHED WHEN EACH CALL IS ANSWERED.
<br />NOTE:WHERE POSSIBLE, A 48-INCH (1219 MM) MAXIMUM HEIGHT FOR ELEVATOR FLOOR BUTTONS IS
<br />PREFERRED.
<br />1124A.3.3.2 CAR CONTROL BUTTONS. PASSENGER ELEVATOR CAR CONTROLS SHALL HAVE A MINIMUM DIMENSION OF 3/4
<br />INCH (19.1 MM) AND SHALL BE RAISED 1/8 INCH (3.2 MM) PLUS OR MINUS 1/32 INCH (0.8 MM) ABOVE THE
<br />SURROUNDING SURFACE. CONTROL BUTTONS SHALL BE ILLUMINATED, SHALL HAVE SQUARE SHOULDERS AND
<br />SHALL BE ACTIVATED BY A MECHANICAL MOTION THAT IS DETECTABLE. ALL CONTROL BUTTONS SHALL BE
<br />DESIGNATED BY A 5/8-INCH MINIMUM( 15.9 MM) RAISED CHARACTERS AND STANDARD RAISED SYMBOLS THAT
<br />COMPLY WITH SECTIONS 1143A.6 AND 1143A.7 (see detail XX / XXX) IMMEDIATELY TO THE LEFT OF THE CONTROL
<br />BUTTON. CONTRACTED GRADE 2 BRAILLE THAT CONFORMS TO SECTION 1143A.7 SHALL BE LOCATED
<br />IMMEDIATELY BELOW THE NUMERAL, CHARACTER OR SYMBOL. A MINIMUM CLEAR SPACE OF3/ 8 INCH (9.5 MM)
<br />OR OTHER SUITABLE MEANS OF SEPARATION SHALL BE PROVIDED BETWEEN ROWS OF CONTROL BUTTONS.
<br />(SEE FIGURE 11A-7B.) THE RAISED CHARACTERS AND SYMBOLS SHALL BE WHITE ON A BLACK BACKGROUND.
<br />CONTROLS AND EMERGENCY EQUIPMENT IDENTIFIED BY RAISED SYMBOLS SHALL INCLUDE, BUT NOT BE LIMITED
<br />TO, "DOOR OPEN," "DOOR CLOSE," "ALARM BELL," "EMERGENCY STOP" AND "TELEPHONE." THE CALL BUTTON FOR
<br />THE MAIN ENTRY FLOOR SHALL BE DESIGNATED BY A RAISED STAR AT THE LEFT OF THE FLOOR DESIGNATION.
<br />1124A.3.4 EMERGENCY TELEPHONE. THE EMERGENCY TELEPHONE HANDSET SHALL BE POSITIONED NO HIGHER THAN 48
<br />INCHES (1219 MM) ABOVE THE FLOOR, AND THE HANDSET CORD SHALL BE A MINIMUM OF29 INCHES (737 MM) IN
<br />LENGTH. IF THE TELEPHONE SYSTEM IS LOCATED IN A CLOSED COMPARTMENT, THE COMPARTMENT DOOR
<br />HARDWARE SHALL CONFORM TO THE PROVISIONS OF SECTION 1138A.4.4 (see detail XX / XXX). EMERGENCY
<br />INTERCOMMUNICATION SHALL NOT REQUIRE VOICE COMMUNICATION.
<br />1124A.4 HALL CALL BUTTONS. CALL OPERATION BUTTONS SHALL BE CENTERED 42 INCHES (1067 MM) ABOVE THE FLOOR.
<br />BUTTONS SHALL BE A MINIMUM OF 3/8 INCH ( 19.1 MM) IN SIZE AND SHALL BE RAISED 1/8-INCH (3.2 MM) PLUS OR
<br />MINUS 1/32-INCH (0.8 MM) ABOVE THE SURROUNDING SURFACE. THE BUTTON DESIGNATING THE "UP" DIRECTION
<br />SHALL BE ON TOP. VISUAL INDICATION SHALL BE PROVIDED TO SHOW EACH CALL REGISTERED EXTINGUISHED
<br />WHEN ANSWERED. OBJECTS ADJACENT TO, AND BELOW, HALL CALL BUTTONS SHALL NOT PROJECT MORE THAN
<br />4 INCHES (101.6 MM) FROM THE WALL. HALL CALL BUTTONS SHALL BE INTERNALLY ILLUMINATED WITH A WHITE
<br />LIGHT OVER THE ENTIRE SURFACE OF THE BUTTON.
<br />1124A.5 MINIMUM ILLUMINATION. THE MINIMUM ILLUMINATION AT THE CAR CONTROLS THRESHOLD AND THE LANDING
<br />WHEN THE CAR AND LANDING DOORS ARE OPEN SHALL NOT BE LESS THAN 5 FOOT-CANDLES (54 LX).
<br />1124A.6 HALL LANTERN. A VISUAL AND AUDIBLE SIGNAL SHALL BE PROVIDED AT EACH HOISTWAY ENTRANCE INDICATING
<br />TO THE PROSPECTIVE PASSENGER THE CAR ANSWERING THE CALL AND ITS DIRECTION OF TRAVEL AS
<br />FOLLOWS:
<br />1. THE VISUAL SIGNAL FOR EACH DIRECTION SHALL BE A MINIMUM OF 2-1/2 INCHES (63.5 MM) HIGH BY 2-1/2
<br />INCHES (63.5 MM) WIDE, AND VISIBLE FROM THE PROXIMITY OF THE HALL CALL BUTTON.
<br />2. THE AUDIBLE SIGNAL SHALL SOUND ONCE FOR THE "UP" DIRECTION AND TWICE FOR THE "DOWN" DIRECTION
<br />OR OF A CONFIGURATION WHICH DISTINGUISHES BETWEEN UP AND DOWN ELEVATOR TRAVEL.
<br />3. THE CENTER LINE OF THE FIXTURE SHALL BE LOCATED A MINIMUM OF6FEET (1829 MM) IN HEIGHT FROM THE
<br />LOBBY FLOOR.
<br />4. THE USE OF IN-CAR LANTERNS, LOCATED IN OR ON THE CAR DOORJAMBS, VISIBLE FROM THE PROXIMITY OF
<br />THE HALL CALL BUTTONS AND CONFORMING TO THE ABOVE REQUIREMENTS OF THIS SECTION SHALL OR
<br />WILL BE ACCEPTABLE.
<br />THE USE OF ARROW SHAPES ARE PREFERRED FOR VISIBLE SIGNALS.
<br />1124A.7 DOOR DELAY.
<br />1124A.7.1 HALL CALL. THE MINIMUM ACCEPTABLE TIME FROM NOTIFICATION THAT A CAR IS ANSWERING A CALL (LANTERN
<br />AND AUDIBLE SIGNAL) UNTIL THE DOORS OF THE CAR START TO CLOSE SHALL BE CALCULATED BY THE
<br />FOLLOWING EQUATIONS BUT SHALL BE NO LESS THAN 5 SECONDS:
<br />T = D / (1.5 ft/s) OR T = D / (445 mm/s)
<br />WHERE 'T' IS THE TOTAL TIME IN SECONDS AND 'D' IS THE DISTANCE FROM A POINT IN THE LOBBY OR
<br />LANDING AREA 60 INCHES (1524 MM) DIRECTLY IN FRONT OF THE FARTHEST CALL BUTTON CONTROLLING THAT
<br />CAR TO THE CENTERLINE OF ITS HOISTWAY DOOR (SEE FIGURE 11A-7D ). FOR CARS WITH IN-CAR LANTERNS, 'T'
<br />BEGINS WHEN THE LANTERN IS VISIBLE FROM THE VICINITY OF HALL CALL BUTTONS AND AN AUDIBLE SIGNAL IS
<br />SOUNDED.
<br />1124A.7.2 DOOR DELAY FOR CAR CALLS. THE MINIMUM ACCEPTABLE TIME FOR THE DOOR TO REMAIN FULLY OPEN AFTER
<br />RECEIVING A CALL SHALL NOT BE LESS THAN 5 SECONDS.
<br />1124A.8 DOOR JAMB MARKING. THE FLOOR LEVEL AT ALL ELEVATOR HOISTWAY ENTRANCES SHALL BE DESIGNATED BY
<br />RAISED CHARACTERS PROVIDED ON BOTH JAMBS. CHARACTERS SHALL BE 2 INCHES (50.8 MM) IN HEIGHT
<br />LOCATED WITH THE CENTERLINE 60 INCHES ( 1524 MM) FROM THE FLOOR. ON THE MAIN ENTRY LEVEL, A RAISED
<br />FIVE POINTED STAR SHALL BE PLACED TO THE LEFT OF THE RAISED CHARACTER. THE OUTSIDE DIAMETER OF
<br />THE STAR SHALL BE 2 INCHES (50.8 MM) AND ALL POINTS SHALL BE OF EQUAL LENGTH. THE RAISED
<br />CHARACTERS AND THE STAR SHALL BE WHITE ON A BLACK BACKGROUND. CONTRACTED GRADE 2 BRAILLE,
<br />CONFORMING TO SECTION 1143A.7 (see detail XX / XXX), SHALL BE PLACED BELOW THE CORRESPONDING RAISED
<br />CHARACTERS AND THE STAR. THE BRAILLE TRANSLATION FOR THE STAR SHALL STATE "MAIN". THE RAISED
<br />CHARACTERS SHALL COMPLY WITH SECTION 1143A.6. (SEE FIGURE 11A-7C.)
<br />1124A.9 DOOR PROTECTIVE AND REOPENING DEVICES. DOORS CLOSED BY AUTOMATIC MEANS SHALL BE PROVIDED
<br />WITH A DOOR REOPENING DEVICE THAT WILL FUNCTION TO STOP AND REOPEN A CAR DOOR AND ADJACENT
<br />HOISTWAY DOOR IN CASE THE CAR DOOR IS OBSTRUCTED WHILE CLOSING. THIS REOPENING DEVICE SHALL
<br />ALSO BE CAPABLE OF SENSING AN OBJECT OR PERSON IN THE PATH OF A CLOSING DOOR WITHOUT REQUIRING
<br />CONTACT FOR ACTIVATION AT A NOMINAL 5 INCHES AND 29 INCHES (127 MM AND 737 MM) ABOVE THE FLOOR.
<br />DOOR-REOPENING DEVICES SHALL REMAIN EFFECTIVE FOR A PERIOD OF NOT LESS THAN 20 SECONDS. AFTER
<br />SUCH AN INTERVAL, THE DOORS MAY CLOSE IN ACCORDANCE WITH THE REQUIREMENTS OF ASME A17.1.
<br />1124A.10 OPERATION AND LEVELING. THE ELEVATOR SHALL BE AUTOMATIC AND BE PROVIDED WITH A SELF-LEVELING
<br />FEATURE THAT WILL AUTOMATICALLY BRING THE CAR TO THE FLOOR LANDINGS WITHIN A TOLERANCE OF PLUS
<br />OR MINUS 1/2 INCH (12.7 MM) UNDER RATED LOADING TO ZERO LOADING CONDITIONS. THIS SELF-LEVELING
<br />SHALL, WITHIN ITS ZONE, BE ENTIRELY AUTOMATIC AND INDEPENDENT OF THE OPERATING DEVICE AND SHALL
<br />CORRECT THE OVER TRAVEL OR UNDER TRAVEL. THE CAR SHALL ALSO BE MAINTAINED APPROXIMATELY LEVEL
<br />WITH THE LANDING, IRRESPECTIVE OF LOAD. THE CLEARANCE BETWEEN THE CAR PLATFORM SILL AND THE
<br />EDGE OF THE HOISTWAY LANDING SHALL BE NO GREATER THAN 1 1/4 INCHES (31.75 MM).
<br />1124A.11 PLATFORM (WHEELCHAIR) LIFTS.
<br />1124A.11.1 GENERAL. PLATFORM (WHEELCHAIR) LIFTS MAY BE PROVIDED BETWEEN LEVELS, IN LIEU OF PASSENGER
<br />ELEVATORS, WHEN THE VERTICAL DISTANCE BETWEEN LANDINGS, AS WELL AS THE STRUCTURAL DESIGN AND
<br />SAFEGUARDS ARE AS ALLOWED BY ASME A18.1, "SAFETY STANDARD FOR PLATFORM LIFTS AND STAIRWAY
<br />CHAIR LIFTS;" THE STATE OF CALIFORNIA, DEPARTMENT OF INDUSTRIAL RELATIONS, DIVISION OF
<br />OCCUPATIONAL SAFETY AND HEALTH (TITLE 8 "ELEVATOR SAFETY ORDERS") AND ANY APPLICABLE SAFETY
<br />REGULATIONS OF OTHER ADMINISTRATIVE AUTHORITIES HAVING JURISDICTION. IF LIFTS ARE PROVIDED, THEY
<br />SHALL BE DESIGNED AND CONSTRUCTED TO FACILITATE UNASSISTED ENTRY, OPERATION AND EXIT FROM THE
<br />LIFT, AND SHALL COMPLY WITH RESTRICTIONS AND ENHANCEMENTS OF THIS SECTION IN CONJUNCTION WITH
<br />TITLE 8 OF THE CALIFORNIA CODE OF REGULATIONS.
<br />1124A.11.2 SIZE AND CLEAR FLOOR SPACE. PLATFORM (WHEELCHAIR)LIFTS SHALL BE OF SUFFICIENT SIZE TO
<br />ACCOMMODATE A WHEELCHAIR IN ACCORDANCE WITH SECTION 1138A.1.4 (see detail XX / XXX).
<br />1124A.11.3 LIFT ACCESS. THERE SHALL BE A LEVEL AND CLEAR FLOOR AREA OR LANDING AT EACH FLOOR OR LEVEL
<br />SERVED BY PLATFORM(WHEELCHAIR) LIFTS. CLEAR FLOOR AREAS OR LANDINGS SHALL MEET THE APPLICABLE
<br />"ACCESSIBLE ROUTE" REQUIREMENTS.
<br />1124A.11.4 STANDBY POWER. TO ENSURE CONTINUED OPERATION IN CASE OF PRIMARY POWER LOSS, PLATFORM
<br />(WHEELCHAIR) LIFTS SHALL BE PROVIDED WITH STANDBY POWER OR WITH SELF RECHARGEABLE BATTERY
<br />POWER THAT PROVIDES SUFFICIENT POWER TO OPERATE ALL PLATFORM LIFT FUNCTIONS FOR A MINIMUM OF
<br />FIVE UPWARD AND DOWNWARD TRIPS.
<br />1124A.11.5 OPENNESS. PLATFORM (WHEELCHAIR) LIFTS ON AN ACCESSIBLE MEANS OF EGRESS SHALL NOT BE INSTALLED IN
<br />A FULLY ENCLOSED HOISTWAY.
<br />1124A.11.6 DOORS AND GATES. LIFTS SHALL HAVE LOW ENERGY POWER-OPERATED DOORS OR GATES, WHICH SHALL
<br />REMAIN OPEN FOR 20 SECONDS MINIMUM. END DOORS SHALL HAVE 32 INCHES (813 MM) MINIMUM CLEAR
<br />OPENING WIDTH. SIDE DOORS CLEAR OPENING WIDTH SHALL BE 42 INCHES (1067 MM) MINIMUM.
<br />EXCEPTION:LIFTS HAVING DOORS OR GATES ON OPPOSITE SIDES SHALL BE PERMITTED TO HAVE SELF-CLOSING MANUAL
<br />DOORS OR GATES.
<br />1124A.11. 7 RESTRICTION SIGN. A SIGN COMPLYING WITH SECTION 1143A (see detail XX / XXX) SHALL BE SECURELY FASTENED
<br />IN A CONSPICUOUS PLACE AT EACH LANDING AND ON THE PLATFORM. THE SIGN SHALL STATE "NO FREIGHT" IN
<br />LETTERS NOT LESS THAN 5/8 INCH (16 MM) HIGH AND INCLUDE THE INTERNATIONAL SYMBOL OF ACCESSIBILITY.
<br />5'-8" MIN
<br />3'-0" MIN
<br />4'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />(b)
<br />side opening door
<br />6'-8" MIN
<br />3'-6" MIN
<br />(a)
<br />center opening door FIGURE 11A-7A
<br />MINIMUM DIMENSIONS FOR ELEVATOR CARS
<br />4'
<br />-
<br />3
<br />"
<br />
<br />M
<br />I
<br />N
<br />4'
<br />-
<br />6
<br />"
<br />
<br />M
<br />I
<br />N
<br />4'
<br />-
<br />3
<br />"
<br />
<br />M
<br />I
<br />N
<br />65
<br />43
<br />21
<br />BS
<br />X
<br />5/
<br />8
<br />"
<br />MI
<br />N
<br />3/4"
<br />MIN button diameter
<br />min separation
<br />characters and
<br />symbols height
<br />place star
<br />alongside main
<br />exit floor number
<br />3/
<br />8
<br />"
<br />MI
<br />N
<br />℄
<br />35
<br />"
<br />
<br />M
<br />I
<br />N
<br />AB
<br />O
<br />V
<br />E
<br />
<br />F
<br />L
<br />O
<br />O
<br />R
<br />CLOSEOPEN
<br />STOPALARM
<br />FIGURE 11A-7A
<br />MINIMUM DIMENSIONS FOR ELEVATOR CARS
<br />(b)
<br />maximum installation heights above cab floor
<br />(a)
<br />elevator control panel detail
<br />2'
<br />-
<br />1
<br />1
<br />"
<br />
<br />M
<br />I
<br />N
<br />48
<br />"
<br />
<br />M
<br />A
<br />X
<br />
<br />F
<br />O
<br />R
<br />
<br />F
<br />R
<br />O
<br />N
<br />T
<br />
<br />A
<br />P
<br />P
<br />R
<br />O
<br />A
<br />C
<br />H
<br />54
<br />"
<br />
<br />M
<br />A
<br />X
<br />
<br />F
<br />O
<br />R
<br />
<br />S
<br />I
<br />D
<br />E
<br />
<br />A
<br />P
<br />P
<br />R
<br />O
<br />A
<br />C
<br />H
<br />2'
<br />-
<br />8
<br />"
<br />
<br />M
<br />I
<br />N
<br />℄
<br />℄
<br />℄
<br />rail
<br />control panel
<br />see (a)
<br />1 1/2"
<br />MIN
<br />FIGURE 11A-7D
<br />GRAPH OF TIMING EQUATION
<br />DISTANCE IN FEET
<br />ACCEPTABLE
<br />'T
<br />'
<br />
<br />T
<br />I
<br />M
<br />E
<br />
<br />I
<br />N
<br />
<br />S
<br />E
<br />C
<br />O
<br />N
<br />D
<br />S
<br />UN
<br />A
<br />C
<br />C
<br />E
<br />P
<br />T
<br />A
<br />B
<br />L
<br />E
<br />5 6 8 10 12 14 16 18
<br />6
<br />5
<br />4
<br />3
<br />2
<br />1
<br />7
<br />8
<br />9
<br />10
<br />11
<br />12
<br />13
<br />0
<br />FIGURE 11A-7C
<br />HOISTWAY AND ELEVATOR ENTRANCES
<br />1
<br />3'-6
<br />"
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />5
<br />'
<br />-
<br />0
<br />"
<br />6'-0
<br />"
<br />℄
<br />℄
<br />℄
<br />
<br />
<br />2
<br />'
<br />-
<br />5
<br />"
<br />
<br />5
<br />"
<br />B
<br />A
<br />floor landing
<br />numbers on both
<br />sides of door jamb
<br />call button
<br />hall lantern
<br />NOTE: The automatic door reopening device is activated if an object passes through either line A or line B. Line A and line
<br />B represent the vertical location of the door reopening devise not requiring contact.
<br />1«2"
<br />
<br />M
<br />I
<br />N
<br />2" MIN
<br />SECTION 3002.4 ELEVATOR CAR TO ACCOMMODATE AMBULANCE STRETCHER
<br />3002.4a GENERAL STRETCHER REQUIREMENTS. ALL BUILDINGS AND STRUCTURES WITH ONE OR MORE PASSENGER ELEVATORS SHALL BE
<br />PROVIDED WITH NOT LESS THAN ONE MEDICAL EMERGENCY SERVICE ELEVATOR TO ALL LANDINGS MEETING THE PROVISIONS OF
<br />SECTION 3002.4a.
<br />EXCEPTIONS:
<br />1.ELEVATORS IN STRUCTURES USED ONLY BY MAINTENANCE AND OPERATION PERSONNEL.
<br />2.ELEVATORS IN JAILS AND PENAL INSTITUTIONS.
<br />3.ELEVATORS IN BUILDINGS OR STRUCTURES WHERE EACH LANDING IS AT GROUND LEVEL OR IS ACCESSIBLE AT GRADE LEVEL OR
<br />BY A RAMP.
<br />4.ELEVATOR(S) IN TWO-STORY BUILDINGS OR STRUCTURES EQUIPPED WITH STAIRS OF A CONFIGURATION THAT WILL
<br />ACCOMMODATE THE CARRYING OF THE GURNEY OR STRETCHER AS PERMITTED BY THE LOCAL JURISDICTIONAL AUTHORITY.
<br />5.ELEVATORS IN BUILDING OR STRUCTURES LESS THEN FOUR STORIES IN HEIGHT FOR WHICH THE THE LOCAL JURISDICTIONAL
<br />AUTHORITY HAS GRANTED AN EXCEPTION IN THE FORM OF A WRITTEN DOCUMENT.
<br />3002.4.1a GURNEY SIZE. THE MEDICAL EMERGENCY SERVICE ELEVATOR SHALL ACCOMMODATE THE LOADING AND TRANSPORT OF AN
<br />AMBULANCE GURNEY OR STRETCHER [MAXIMUM SIZE 24 INCHES BY 84 INCHES (610 MM BY 2134 MM) WITH NOT LESS THAN 5-INCH
<br />(127MM) RADIUS CORNERS] IN THE HORIZONTAL POSITION.
<br />3002.4.2a HOISTWAY DOORS, THE HOISTWAY LANDING OPENINGS SHALL BE PROVIDED WITH POWER-OPERATED DOORS.
<br />3002.4.3a ELEVATOR ENTRANCE OPENING AND CAR SIZE. THE ELEVATOR CAR SHALL BE OF SUCH A SIZE AND ARRANGEMENT TO
<br />ACCOMMODATE A 24 INCHES BY 84 INCHES (610 MM BY 2134 MM)AMBULANCE GURNEY OR STRETCHER WITH NOT LESS THAN
<br />5-INCH (127MM) RADIUS CORNERS, IN THE HORIZONTAL, OPEN POSITION, SHALL BE PROVIDED WITH A MINIMUM CLEAR DISTANCE
<br />BETWEEN WALLS OR BETWEEN WALLS AND DOOR EXCLUDING RETURN PANELS NOT LESS THAN 80INCHES BY 54 INCHES (2032 MM
<br />BY 1372 MM), AND A MINIMUM DISTANCE FROM WALL AND RETURN PANEL NOT LESS THAN 51 INCHES(1295 MM) WITH A 42 INCH
<br />(1067 MM) SIDE SLIDE DOOR.
<br />EXCEPTION:THE ELEVATOR CAR DIMENSIONS AND/OR THE CLEAR ENTRANCE OPENING DIMENSIONS MAY BE ALTERED WHERE IT CAN BE
<br />DEMONSTRATED TO THE LOCAL JURISDICTIONAL AUTHORITY'S SATISFACTION THAT THE PROPOSED CONFIGURATION WILL
<br />HANDEL THE DESIGNATED GURNEY OR STRETCHER WITH EQUIVALENT EASE. DOCUMENTATION FROM THE LOCAL AUTHORITY
<br />SHALL BE PROVIDED TO THE OCCUPATIONAL SAFETY AND HEALTH STANDARDS BOARD.
<br />3002.4.4a ELEVATOR RECALL. THE ELEVATOR(S) DESIGNATED THE MEDICAL EMERGENCY ELEVATOR SHALL BE EQUIPPED WITH A KEY
<br />SWITCH TO RECALL THE ELEVATOR NONSTOP TO THE MAIN FLOOR. FOR THE PURPOSE OF THIS SECTION, ELEVATORS IN
<br />COMPLIANCE WITH SECTION 3002.2 SHALL BE ACCEPTABLE.
<br />3002.4.5a DESIGNATION. MEDICAL EMERGENCY ELEVATORS SHALL BE IDENTIFIED BY THE INTERNATIONAL (STAR OR LIFE) FOR EMERGENCY
<br />MEDICAL SERVICES.
<br />3002.4.6a SYMBOL SIZE. THE SYMBOL SHALL NOT BE LESS THAN 3 INCHES (76 MM) IN SIZE.
<br />3002.4.7a SYMBOL LOCATION. A SYMBOL SHALL BE PERMANENTLY ATTACHED TO EACH SIDE OF THE HOISTWAY DOOR FRAME ON THE
<br />PORTION OF THE FRAME AT RIGHT ANGLES TO THE HALLWAY OR LANDING AREA. EACH SYMBOL SHALL NOT BE LESS THAN 78
<br />INCHES (1981 MM) AND NOT MORE THAN 84 INCHES (2134 MM) ABOVE THE FLOOR LEVEL AT THE THRESHOLD.
<br />SEE CBC CHAPTER 30, ELEVATORS AND CONVEYING SYSTEMS, FOR ADDITIONAL REQUIREMENTS NOT SHOWN HERE.
<br />SEC. 1125A HAZARDS ON ACCESSIBLE ROUTES -
<br />SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
<br />1125A.1 WARNING CURBS. ABRUPT CHANGES IN LEVEL EXCEEDING 4 INCHES (101.6 MM) IN VERTICAL DIMENSION,
<br />SUCH AS CHANGES IN LEVEL AT PLANTERS OR FOUNTAINS LOCATED IN OR ADJACENT TO WALKS, HALLS,
<br />CORRIDORS, PASSAGEWAYS, AISLES, PEDESTRIAN WAYS AND OTHER CIRCULATION SPACES SHALL BE
<br />IDENTIFIED BY CURBS PROJECTING AT LEAST 6 INCHES (152.4 MM) IN HEIGHT ABOVE THE WALK OR
<br />SIDEWALK SURFACE TO WARN THE BLIND OF A POTENTIAL DROP-OFF
<br />EXCEPTION:WHEN A GUARDRAIL OR HANDRAIL IS PROVIDED WITH EDGE PROTECTION IN ACCORDANCE WITH CBC
<br />SECTION 1010.10.1.
<br />1125A.2 HEADROOM CLEARANCE. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES, PEDESTRIAN WAYS AND
<br />OTHER CIRCULATION SPACES WHICH ARE PART OF THE REQUIRED EGRESS SYSTEM SHALL HAVE A
<br />MINIMUM CLEAR HEADROOM AS REQUIRED IN CBC SECTION 1003.2. OTHER WALKS, PEDESTRIAN WAYS
<br />AND CIRCULATION SPACES SHALL HAVE A MINIMUM CLEAR HEADROOM OF 80 INCHES (2032 MM). IF THE
<br />VERTICAL CLEARANCE OF AN AREA ADJOINING AN ACCESSIBLE ROUTE IS REDUCED TO LESS THAN 80
<br />INCHES (2032 MM) NOMINAL DIMENSION, A GUARDRAIL OR OTHER BARRIER HAVING ITS LEADING EDGE AT
<br />OR BELOW 27 INCHES (686 MM) ABOVE THE FINISHED FLOOR SHALL BE PROVIDED.
<br />6"
<br />MI
<br />N
<br />HI
<br />G
<br />H
<br />to suit
<br />design
<br />GUIDE CURB DETAIL
<br />>
<br />4
<br />"
<br />abrupt change in level
<br />EGRESS HEADROOM CLEARANCE
<br />2'
<br />-
<br />3
<br />"
<br />
<br />M
<br />A
<br />X
<br />X
<br /><
<br />
<br />6
<br />'
<br />-
<br />8
<br />"
<br />guard or barrier
<br />rail
<br />FIGURE 11A-1B
<br />HEADROOM CLEARANCE AND OVERHANGING PROJECTION
<br />6'
<br />-
<br />8
<br />"
<br />
<br />M
<br />I
<br />N
<br />ov
<br />e
<br />r
<br />h
<br />a
<br />n
<br />g
<br />i
<br />n
<br />g
<br />
<br />o
<br />b
<br />s
<br />t
<br />r
<br />u
<br />c
<br />t
<br />i
<br />o
<br />n
<br />7'
<br />-
<br />0
<br />"
<br />
<br />M
<br />I
<br />N
<br />he
<br />a
<br />d
<br />r
<br />o
<br />o
<br />m
<br />
<br />c
<br />l
<br />e
<br />a
<br />r
<br />a
<br />n
<br />c
<br />e
<br />3 1
<br />2
|