Laserfiche WebLink
32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />A0.20 <br />DWELLING ADA <br />NOTES DETAILS <br />SCALE: N/A <br />SEC. 1127A.1 COMMON USE FACILITIES; GENERAL - <br />SECTION 1127A COMMON USE FACILITIES <br />256729.1.FOR PUBLIC USE FACILITIES, SEE CHAPTER 11B OF THIS CODE; SHEET SERIES XX FOR <br />CHAPTER 11A DIVISION I, APPLICATION AND GENERAL PROVISIONS, SECTIONS 1101A THROUGH 1107,SEE <br />SHEET XXX. <br />256730.FOR CHAPTER 11A DIVISION II, EXTERIOR FACILITIES, SECTIONS 1108A THROUGH 1116, SEE SHEETS <br />XXX AND XXX. <br />256731.FOR CHAPTER 11A DIVISION III, BUILDING FEATURES, SECTIONS 1117A THROUGH 1126A, SEE SHEETS <br />XXX AND XXX. <br />256732.FOR CHAPTER 11A DIVISION IV DWELLING UNIT FEATURES, SECTIONS 1128A THROUGH 1136A, SEE <br />SHEETS XXX. <br />256733.FOR CHAPTER 11A DIVISION V, FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS, <br />SECTIONS 1137A THROUGH 1143A, SEE SHEETS XXX. <br />1127A.1 GENERAL. WHEN PROVIDED, COMMON USE AREAS AND FACILITIES IN COVERED MULTIFAMILY HOUSING <br />DEVELOPMENTS SHALL BE ACCESSIBLE TO PERSONS WITH DISABILITIES. COMMON USE FACILITIES INCLUDE, <br />BUT ARE NOT LIMITED TO, LOBBIES, TOILET AND BATHING FACILITIES, LAUNDRY FACILITIES, COMMUNITY <br />ROOMS, CLUBHOUSES, HEALTH AND FITNESS FACILITIES, GAME ROOMS AND PORTIONS OF COMMON USE <br />TENANT STORAGE. ALL ENTRANCES, DOORS, FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE ROUTE. <br />FACILITIES AND FIXTURES REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING PROVISIONS: <br />1. DOORS. DOORS TO ACCESSIBLE BATHROOMS SHALL COMPLY WITH SECTION 1126A. DOORS SHALL NOT <br />SWING INTO THE FLOOR SPACE REQUIRED FOR ANY FIXTURE. (see detail 7 / A0.15) <br />2. CLEAR FLOOR SPACE. ALL FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE ROUTE. CLEAR FLOOR <br />SPACES AT FIXTURES AND CONTROLS, THE ACCESSIBLE ROUTE AND THE TURNING SPACE MAY OVERLAP. <br />THIS CLEAR SPACE SHALL COMPLY WITH SECTIONS 1138A.1.4 AND 1138A.3. (see detail 3 / A0.14) <br />3. WATER CLOSETS. WHERE A TOILET STALL IS PROVIDED, IT SHALL COMPLY WITH SECTION 1127A.2.1 OR <br />1127A.2.2, AND ITS WATER CLOSET SHALL COMPLY WITH SECTION 1 127A.2.3.(see detail 2 / A0.20) <br />4. LAVATORY AND MIRRORS. WHERE A LAVATORY AND/OR MIRROR IS PROVIDED, IT SHALL COMPLY WITH <br />SECTIONS 1127A.3 AND/OR 1127A.8.3. (see detail 1 / A0.13) <br />5. CONTROLS AND DISPENSERS. WHERE CONTROLS, DISPENSERS, RECEPTACLES OR OTHER TYPES OF <br />EQUIPMENT ARE PROVIDED, AT LEAST ONE OF EACH SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL <br />COMPLY WITH SECTIONS 1127A.8 AND 1138A.3. see details 9 / A0.20 & 1 / A0.16). <br />6. BATHING AND SHOWER FACILITIES. WHERE BATHTUBS OR SHOWERS ARE PROVIDED, AT LEAST ONE <br />FIXTURE OF EACH TYPE PROVIDED SHALL BE ACCESSIBLE PER ROOM. FOR BATHTUBS, SEE SECTION <br />1127A.5.2. FOR SHOWER COMPARTMENTS, SEE SECTION 1127A.5.3. (see detail 1/ A0.17) <br />7. TOILET FACILITIES. TOILET FACILITIES SHALL COMPLY WITH SECTION 1127A.2. (see detail 2 / A0.20) <br />8. LAUNDRY FACILITIES. LAUNDRY FACILITIES SHALL COMPLY WITH SECTION 1127 A.10. (see detail 2 / A0.17) <br />9. STORAGE FACILITIES. STORAGE FACILITIES SHALL COMPLY WITH SECTION 1127 A.11. (see detail 3 / A0.14) <br />10. FIXED OR BUILT-IN SEATING TABLES AND COUNTERS. FIXED OR BUILT-IN SEATING, TABLES AND <br />COUNTERS SHALL COMPLY WITH SECTION 1127A.12. (see detail 5 / A0.14) <br />SEC. 1127A.2 TOILET FACILITIES - <br />1127 A.2 TOILET FACILITIES <br />WHEN COMMON USE TOILET FACILITIES ARE PROVIDED FOR RESIDENTS OR GUESTS, AT LEAST ONE PERCENT OF <br />THE TOTAL NUMBER OF FIXTURES BUT NOT LESS THAN ONE OF EACH TYPE SHALL COMPLY WITH THIS SECTION. <br />1127 A.2.1 MULTIPLE-ACCOMMODATION TOILET FACILITIES. <br />MULTIPLE-ACCOMMODATION TOILET FACILITIES SHALL HAVE THE FOLLOWING: <br />NOTE: (SEE FIGURES 11A-9A AND L1A-9B.) <br />1. WHEELCHAIR TURNING SPACE. TURNING SPACE OF SUFFICIENT SIZE TO INSCRIBE A CIRCLE WITH A <br />DIAMETER NOT LESS THAN 60 INCHES ( 1524 MM) OR A T-SHAPED SPACE SHALL BE PROVIDED WITHIN <br />THE TOILET FACILITY. THE WHEELCHAIR TURNING SPACE SHALL COMPLY WITH SECTION 1138A.1.3 (see <br />detail XX / XXX). OTHER THAN THE DOOR TO THE ACCESSIBLE WATER CLOSET COMPARTMENT, A DOOR, <br />IN ANY POSITION, MAY ENCROACH INTO THIS SPACE BY NOT MORE THAN 12 INCHES ( 305 MM). <br />2. CLEAR SPACE AT FIXTURES. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR SPACE REQUIRED <br />FOR ANY FIXTURE. REQUIRED CLEAR FLOOR SPACE, CLEARANCE AT FIXTURES, AND TURNING SPACE <br />SHALL BE PERMITTED TO OVERLAP. <br />3. ACCESSIBLE WATER CLOSET COMPARTMENT. ACCESSIBLE WATER CLOSET COMPARTMENTS SHALL <br />BE 60 INCHES ( 1524 MM) WIDE MINIMUM MEASURED PERPENDICULAR TO THE SIDE WALL, 56 INCHES <br />(1422 MM) DEEP MINIMUM FOR WALL HUNG WATER CLOSETS AND 59 INCHES (1499 MM) DEEP MINIMUM <br />FOR FLOOR MOUNTED WATER CLOSETS MEASURED PERPENDICULAR TO THE REAR WALL. (SEE <br />FIGURE 11A-9A(C)). WATER CLOSET FIXTURES LOCATED IN ACCESSIBLE WATER CLOSET <br />COMPARTMENTS SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. <br />THE CENTERLINE OF THE WATER CLOSET SHALL BE 17 INCHES (432 MM) MINIMUM TO 18 INCHES ( 457 <br />MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. IN AMBULATORY ACCESSIBLE TOILET <br />COMPARTMENTS SPECIFIED IN ITEM 6 OF THIS SECTION, THE WATER CLOSET SHALL BE 17 INCHES (432 <br />MM) MINIMUM AND 19 INCHES (483 MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. (SEE FIGURE <br />11A-9A (D). CLEARANCE AROUND A WATER CLOSET SHALL BE 60 INCHES ( 1524 MM) MINIMUM <br />MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES ( 1422 MM) MINIMUM MEASURED <br />PERPENDICULAR FROM THE REAR WALL. THE REQUIRED CLEARANCE AROUND THE WATER CLOSET <br />SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED GRAB BARS, DISPENSERS, <br />SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR <br />SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING SPACE. NO OTHER <br />FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER CLOSET <br />CLEARANCE. A MINIMUM 48 INCHES ( 1219 MM) DEEP AND 60 INCHES ( 1524 MM) WIDE CLEAR <br />MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET IF THE COMPARTMENT <br />HAS AN END-OPENING DOOR (FACING THE WATER CLOSET). A MINIMUM 60 INCHES (1524 MM) DEEP <br />AND 60 INCHES ( 1524 MM) WIDE CLEAR MANEUVERING SPACE SHALL BE PROVIDED IN A <br />COMPARTMENT WITH THE DOOR LOCATED AT THE SIDE. (SEE FIGURE 11A-9A). <br />4. GRAB BARS. GRAB BARS SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET <br />AND ON THE REAR WALL. GRAB BARS SHALL COMPLY WITH THIS SECTION AND SECTION 1127A.4 (see <br />detail XX this sheet). THE SIDE WALL GRAB BAR SHALL BE 42 INCHES ( 1067 MM) LONG MINIMUM, <br />LOCATED 12 INCHES (305 MM) MAXIMUM FROM THE REAR WALL AND EXTEND 54 INCHES ( 1372 MM) <br />MINIMUM FROM THE REAR WALL. THE FRONT END OF THE SIDE GRAB BAR SHALL BE POSITIONED 24 <br />INCHES (610 MM) MINIMUM IN FRONT OF THE WATER CLOSET. THE REAR WALL GRAB BAR SHALL BE 36 <br />INCHES (914 MM) LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 <br />INCHES ( 305 MM) MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON THE OTHER SIDE. <br />EXCEPTIONS: <br />1. THE REAR GRAB BAR SHALL BE PERMITTED TO BE 24 INCHES (610 MM) LONG MINIMUM, <br />CENTERED ON THE WATER CLOSET, WHEN WALL SPACE DOES NOT PERMIT A LENGTH OF 36 <br />INCHES (914 MM) MINIMUM DUE TO THE LOCATION OF A RECESSED FIXTURE ADJACENT TO THE <br />WATER CLOSET. <br />2. WHEN THE ENFORCING AGENCY REQUIRES FLUSH CONTROLS FOR FLUSH VALVES TO BE <br />LOCATED IN A POSITION THAT CONFLICTS WITH THE LOCATION OF THE REAR GRAB BAR, THEN <br />THE REAR GRAB BAR SHALL BE PERMITTED TO BE SPLIT OR SHIFTED TO THE OPEN SIDE OF <br />THE TOILET AREA. <br />5. COMPARTMENT DOORS. COMPARTMENT DOORS SHALL COMPLY WITH THE FOLLOWING: <br />5.1.THE WATER CLOSET COMPARTMENT SHALL BE EQUIPPED WITH A DOOR THAT HAS AN AUTOMATIC <br />CLOSING DEVICE, AND SHALL HAVE A CLEAR, UNOBSTRUCTED OPENING WIDTH OF 32 INCHES (813 <br />MM) WHEN LOCATED AT THE END AND 34 INCHES (864 MM) WHEN LOCATED AT THE SIDE WITH THE <br />DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION. <br />5.2.WHEN STANDARD COMPARTMENT DOORS ARE USED, WITH A MINIMUM 9-INCH (228.6 MM) <br />CLEARANCE FOR FOOTRESTS UNDERNEATH AND A SELF-CLOSING DEVICE, CLEARANCE AT THE <br />STRIKE EDGE AS SPECIFIED IN SECTION 1126A.3.2 IS NOT REQUIRED. <br />5.3.THE INSIDE AND OUTSIDE OF THE COMPARTMENT DOOR SHALL BE EQUIPPED WITH A LOOP OR <br />U-SHAPED HANDLE IMMEDIATELY BELOW THE LATCH. THE LATCH SHALL BE FLIP-OVER STYLE, <br />SLIDING OR OTHER HARDWARE NOT REQUIRING THE USER TO GRASP OR TWIST. <br /> <br />5.4.EXCEPT FOR DOOR-OPENING WIDTHS AND DOOR SWINGS, A CLEAR, UNOBSTRUCTED ACCESS OF <br />NOT LESS THAN 44 INCHES (1118 MM) SHALL BE PROVIDED TO WATER CLOSET COMPARTMENTS <br />DESIGNED FOR USE BY PERSONS WITH DISABILITIES, AND THE SPACE IMMEDIATELY IN FRONT OF <br />A WATER CLOSET COMPARTMENT SHALL NOT BE LESS THAN 48 INCHES (1219 MM) AS MEASURED <br />AT RIGHT ANGLES TO COMPARTMENT DOOR IN ITS CLOSED POSITION. <br />6. AMBULATORY ACCESSIBLE COMPARTMENTS. WHEN SIX OR MORE TOILET COMPARTMENTS ARE <br />PROVIDED WITHIN A MULTIPLE-ACCOMMODATION TOILET ROOM, OR WHEN THE COMBINATION OF <br />URINALS AND WATER CLOSETS TOTALS SIX OR MORE FIXTURES, AT LEAST ONE COMPARTMENT SHALL <br />COMPLY WITH SECTION 1127A.2.1, ITEMS 2 AND 3. AT LEAST ONE ADDITIONAL AMBULATORY <br />COMPARTMENT SHALL HAVE A DEPTH OF 60 INCHES ( 1524 MM) MINIMUM, AND A WIDTH OF 35 INCHES <br />(890 MM) MINIMUM AND 37 INCHES (940 MM) MAXIMUM. THE AMBULATORY ACCESSIBLE COMPARTMENT <br />SHALL HAVE A SELF-CLOSING DOOR, WHICH SHALL NOT SWING INTO THE MINIMUM REQUIRED <br />COMPARTMENT AREA. GRAB BARS, COMPLYING WITH SECTIONS 1127A.4.2, 1127A.4.3, 1127A.4.4 AND <br />1127A.4.5, SHALL BE INSTALLED ON EACH COMPARTMENT SIDE WALL (see detail X this sheet). SEE <br />FIGURE11A-9A(D). <br />1127 A.2.2 SINGLE-ACCOMMODATION TOILET FACILITIES. <br />SINGLE ACCOMMODATION TOILET FACILITIES SHALL COMPLY WITH THE FOLLOWING: <br />NOTE:SEE FIGURES 11A-9A AND 11A-9B. <br />1. WHEELCHAIR CLEARANCE. THERE SHALL BE SUFFICIENT SPACE IN THE TOILET ROOM FOR A <br />WHEELCHAIR MEASURING 30 INCHES (762 MM) WIDE BY 48 INCHES (1219 MM) LONG TO ENTER THE <br />ROOM AND PERMIT THE DOOR TO CLOSE. THERE SHALL BE IN THE ROOM A CLEAR TURNING SPACE OF <br />AT LEAST 60 INCHES (1524 MM) IN DIAMETER OR A T SHAPED SPACE COMPLYING WITH SECTION <br />1138A.1.3 (see detail XX / XXX). REQUIRED CLEAR FLOOR SPACE, CLEARANCE AT FIXTURES, AND <br />TURNING SPACE SHALL BE PERMITTED TO OVERLAP. <br />2. ENCROACHMENT OF DOORS. DOORS SHALL NOT ENCROACH INTO THE TURNING SPACE SPECIFIED IN <br />ITEM 1 OF THIS SECTION BY MORE THAN 12 INCHES (305 MM). <br />3. ACCESSIBLE WATER CLOSET. A WATER CLOSET FIXTURE LOCATED IN A SINGLE-ACCOMMODATION <br />TOILET FACILITY SHALL BE POSITIONED WITH A WALL OR PARTITION TO THE REAR AND TO ONE SIDE. <br />THE CENTERLINE OF THE WATER CLOSET SHALL BE 17 INCHES (432 MM) MINIMUM TO 18 INCHES (457 <br />MM) MAXIMUM FROM THE SIDE WALL OR PARTITION. CLEARANCE AROUND A WATER CLOSET SHALL BE <br />60 INCHES (1524 MM) MINIMUM MEASURED PERPENDICULAR FROM THE SIDE WALL AND 56 INCHES <br />(1422 MM) MINIMUM MEASURED PERPENDICULAR FROM THE REAR WALL. THE REQUIRED CLEARANCE <br />AROUND THE WATER CLOSET SHALL BE PERMITTED TO OVERLAP THE WATER CLOSET, ASSOCIATED <br />GRAB BARS, DISPENSERS, SANITARY NAPKIN DISPOSAL UNITS, COAT HOOKS, SHELVES, ACCESSIBLE <br />ROUTES, CLEAR FLOOR SPACE AND CLEARANCES REQUIRED AT OTHER FIXTURES, AND THE TURNING <br />SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS SHALL BE LOCATED WITHIN THE REQUIRED WATER <br />CLOSET CLEARANCE. A MINIMUM 48 INCHES (1219 MM) DEEP AND 60 INCHES (1524 MM) WIDE CLEAR <br />MANEUVERING SPACE SHALL BE PROVIDED IN FRONT OF THE WATER CLOSET. <br />4. GRAB BARS. GRAB BARS SHALL BE PROVIDED ON THE SIDE WALL CLOSEST TO THE WATER CLOSET <br />AND ON THE REAR WALL. GRAB BARS SHALL COMPLY WITH THIS SECTION AND SECTION 1127A.4 (see <br />detail XX this sheet). THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1067 MM) LONG MINIMUM, LOCATED <br />12 INCHES (305 MM) MAXIMUM FROM THE REAR WALL AND EXTEND 54 INCHES (1372 MM) MINIMUM <br />FROM THE REAR WALL. THE FRONT END OF THE SIDE GRAB BAR SHALL BE POSITIONED 24 INCHES (610 <br />MM) MINIMUM IN FRONT OF THE WATER CLOSET. THE REAR WALL GRAB BAR SHALL BE 36 INCHES (914 <br />MM) LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 INCHES (305 MM) <br />MINIMUM ON ONE SIDE AND 24 INCHES (610 MM) MINIMUM ON THE OTHER SIDE. <br />EXCEPTIONS: <br />1. THE REAR GRAB BAR SHALL BE PERMITTED TO BE 24 INCHES (610 MM) LONG MINIMUM, <br />CENTERED ON THE WATER CLOSET, WHEN WALL SPACE DOES NOT PERMIT A LENGTH OF 36 <br />INCHES (914 MM) MINIMUM DUE TO THE LOCATION OF A RECESSED FIXTURE ADJACENT TO THE <br />WATER CLOSET. <br />2. WHEN THE ENFORCING AGENCY REQUIRES FLUSH CONTROLS FOR FLUSH VALVES TO BE <br />LOCATED IN A POSITION THAT CONFLICTS WITH THE LOCATION OF THE REAR GRAB BAR, THEN <br />THE REAR GRAB BAR SHALL BE PERMITTED TO BE SPLIT OR SHIFTED TO THE OPEN SIDE OF <br />THE TOILET AREA. <br />3. ACCESSIBLE ROUTE. ALL DOORS, FIXTURES AND CONTROLS SHALL BE ON AN ACCESSIBLE <br />ROUTE. THE MINIMUM CLEAR WIDTH OF AN ACCESSIBLE ROUTE SHALL BE 36 INCHES (914 MM) <br />EXCEPT AT DOORS (SEE SECTION 1126A; detail XX / XXX). IF A PERSON IN A WHEELCHAIR MUST <br />MAKE A TURN AROUND AN OBSTRUCTION, THE MINIMUM CLEAR WIDTH OF THE ACCESSIBLE <br />ROUTE SHALL BE AS SPECIFIED IN SECTION 1138A.J.5. <br />1127A.2.3 WATER CLOSETS. <br />WATER CLOSETS REQUIRED TO BE ACCESSIBLE SHALL COMPLY WITH THE FOLLOWING: <br />NOTE:SEE FIGURE 11A-9B. <br />1. HEIGHT. THE HEIGHT OF ACCESSIBLE WATER CLOSETS SHALL BE A MINIMUM OF 17 INCHES (432 MM) <br />TO A MAXIMUM OF 19 INCHES (483 MM) MEASURED TO THE TOP OF A MAXIMUM2-INCH-HIGH ( 50.8 MM) <br />TOILET SEAT. <br />2. CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED <br />CONTROLS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT <br />GRASPING,PINCHING OR TWISTING. CONTROLS FOR THE FLUSH VALVES SHALL BE MOUNTED ON THE <br />OPEN SIDE OF THE WATER CLOSET NO MORE THAN 44 INCHES (1118 MM) ABOVE THE FLOOR. THE <br />FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS (22.2 N). <br />3. TOILET SEATS. SEATS SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. <br />1127A.2.4 ACCESSIBLE URINALS. <br />WHEN URINALS ARE PROVIDED, AT LEAST ONE SHALL COMPLY WITH THE FOLLOWING: <br />1. HEIGHT AND WALL PROJECTION. URINALS SHALL BE FLOOR MOUNTED (STALL TYPE) OR <br />WALL HUNG. THE RIM OF THE WALL HUNG URINALS SHALL BE 17 INCHES (432 MM) MAXIMUM <br />ABOVE THE FINISH FLOOR. URINALS (FLOOR MOUNTED AND WALL HUNG) SHALL BE 13-1/ 2 <br />INCHES (343 MM) DEEP MINIMUM MEASURED FROM THE OUTER FACE OF THE RIM TO THE <br />BACK OF THE FIXTURE. <br />2. FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC. HAND OPERATED <br />CONTROLS SHALL BE OPERABLE WITH ONE HAND, SHALL NOT REQUIRE TIGHT GRASPING, PINCHING <br />OR TWISTING OF THE WRIST AND SHALL BE MOUNTED NO MORE THAN 44 INCHES (1118 MM) ABOVE <br />THE FLOOR. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 POUNDS <br />(22.2 N). ELECTRONIC AUTOMATIC FLUSHING CONTROLS ARE PREFERABLE. <br />3. CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE 30 INCHES BY 48 INCHES (762 MM BY 1219 MM) SHALL BE <br />PROVIDED IN FRONT OF THE URINAL TO ALLOW FORWARD APPROACH. THE CLEAR FLOOR SPACE <br />SHALL COMPLY WITH SECTION 1138A.1.4 (see detail XX / XXX). <br />54" MIN <br />60" MIN <br />24" MIN <br />5'-0" MIN <br />12" <br />MAX <br />(b) <br />single-accommodation toilet facility <br />(a) <br />multiple-accommodation toilet facility <br />flush activator on <br />wide side <br />36" minimum <br />grab bar <br />42" minimum <br />grab bar <br />2'-10" MIN <br />CLEAR AT <br />SIDE DOOR <br />5' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br />60 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br /> <br />D <br />I <br />A <br />M <br />E <br />T <br />E <br />R <br />60" M <br />I <br />N <br />CLEA <br />R <br /> <br />D <br />I <br />A <br />M <br />E <br />T <br />E <br />R <br />30" x 48" clear <br />space <br />54 <br />" <br /> <br />M <br />I <br />N <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />C <br />L <br />E <br />A <br />R <br />12 <br />" <br />MA <br />X <br />17 <br />" <br /> <br />- <br /> <br />1 <br />8 <br />" <br />17" - 18"18" <br />MIN <br />3'-8" MIN <br />CLEAR <br />2' <br />- <br />8 <br />" <br /> <br />M <br />I <br />N <br />CL <br />E <br />A <br />R <br />2'-8" MIN <br />CLEAR <br />18" <br />MIN <br />CLEAR <br />60" MIN <br />(d) <br />ambulatory accessible compartment <br />(c) <br />accessible water closet compartment within <br />multiple-accommodation toilet facility <br />FIGURE 11A-9A <br />TOILET FACILITIES <br />54 <br />" <br /> <br />M <br />I <br />N <br />48 <br />" <br /> <br />M <br />I <br />N <br /> <br />C <br />L <br />E <br />A <br />R <br />12 <br />" <br />MA <br />X <br />17" - 18" <br />60" MIN <br />2'-8" MIN <br />CLEAR <br />18" <br />MIN <br />CLEAR <br />59 <br />" <br /> <br />M <br />I <br />N <br />fo <br />r <br /> <br />f <br />l <br />o <br />o <br />r <br /> <br />m <br />o <br />u <br />n <br />t <br />e <br />d <br /> <br />w <br />. <br />c <br />. <br />56 <br />" <br /> <br />M <br />I <br />N <br />fo <br />r <br /> <br />w <br />a <br />l <br />l <br /> <br />m <br />o <br />u <br />n <br />t <br />e <br />d <br /> <br />w <br />. <br />c <br />. <br />4" <br />MAX <br />35" - 37" <br />5' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />54 <br />" <br /> <br />M <br />I <br />N <br />12 <br />" <br />MA <br />X <br />17" - 19" <br />℄℄℄℄ <br />℄ <br />transfer <br />side <br />3'-0" MIN <br />1'-0" <br />MIN <br />2'-0" <br />MIN <br />℄ <br />4'-6" MIN <br />1'-0" <br />MAX 3'-6" MIN <br />(c) <br />clear floor space at waterclosets <br />(b) <br />front viewFIGURE 11A-9B <br />WATER CLOSETS <br />59 <br />" <br /> <br />M <br />I <br />N <br />fo <br />r <br /> <br />f <br />l <br />o <br />o <br />r <br /> <br />m <br />o <br />u <br />n <br />t <br />e <br />d <br /> <br />w <br />. <br />c <br />. <br />56 <br />" <br /> <br />M <br />I <br />N <br />fo <br />r <br /> <br />w <br />a <br />l <br />l <br /> <br />m <br />o <br />u <br />n <br />t <br />e <br />d <br /> <br />w <br />. <br />c <br />. <br />(a) <br />side view <br /> 1' <br />- <br />7 <br />" <br />MI <br />N7" - 9" <br />℄ <br />℄ <br />17 <br />" <br />- <br /> <br />1 <br />9 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br /> 3' <br />- <br />4 <br />" <br /> <br />M <br />A <br />X <br />℄ <br />17 <br />" <br />- <br /> <br />1 <br />9 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br />HEIGHT AND DEPTH OF URINALS <br />(b) <br />stall type <br />(a) <br />wall hung type <br />1'-1 1/2" <br />MIN <br /> 1' <br />- <br />5 <br />" <br />MA <br />X <br />1'-1 1/2" <br />MIN <br />SEC. 1127A.3 ACCESSIBLE LAVATORIES - <br />1127 A.3 ACCESSIBLE LAVATORIES <br />WHEN COMMON USE LAVATORIES ARE PROVIDED FOR RESIDENTS OR GUESTS, AT LEAST ONE, AND NOT LESS THAN 1 PERCENT OF <br />ALL LAVATORIES, SHALL COMPLY WITH THE FOLLOWING: <br />1. LOCATION. LAVATORIES SHALL BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE A MINIMUM OF 18 INCHES (457 MM) <br />HORIZONTALLY FROM AN ADJOINING WALL, PARTITION OR FIXTURE. THE TOP OF THE FIXTURE RIM SHALL BE A MAXIMUM OF 34 <br />INCHES (864 MM) ABOVE THE FINISHED FLOOR. <br />2. FLOOR SPACE. A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES (762 MM BY 1219 MM) SHALL BE PROVIDED IN FRONT OF <br />ACCESSIBLE LAVATORIES TO ALLOW FORWARD APPROACH. SUCH CLEAR FLOOR SPACE SHALL ADJOIN OR OVERLAP AN <br />ACCESSIBLE ROUTE OR ANOTHER CLEAR FLOOR SPACE. <br />3. KNEE AND TOE SPACE. A CLEAR AND OBSTRUCTED KNEE AND TOE SPACE, COMPLYING WITH SECTION 1138A.2, SHALL BE <br />PROVIDED UNDERNEATH THE LAVATORY. THE KNEE AND TOE SPACE SHALL BE CENTERED ON THE FIXTURE. THE CLEAR FLOOR <br />SPACE REQUIRED BY ITEM 2 SHALL NOT EXTEND INTO THE KNEE AND TOE SPACE MORE THAN 19 INCHES (483 MM). (SEE <br />FIGURE11A-9D.) <br />4. FINISHED FLOOR. THE FINISHED FLOOR BENEATH THE LAVATORY SHALL BE EXTENDED TO THE WALL. 5. PLUMBING PROTECTION. <br />WATER SUPPLY AND DRAIN PIPES ACCESSIBLE UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE COVERED TO PROTECT <br />AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.5. LAVATORY FAUCET CONTROLS. <br />FAUCET CONTROLS AND OPERATION MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT <br />GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN <br />5 POUNDS (22.2N). LEVER OPERATED, PUSH TYPE AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF <br />ACCEPTABLE DESIGNS. HAND OPERATED METERING FAUCETS ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 <br />SECONDS. <br /> <br />2 <br />' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />FIGURE 11A-9D <br />KNEE AND TOE SPACE <br />(c) <br />knee and toe space for lavatories <br />section plan <br /> <br />2 <br />' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />9" <br />MI <br />N <br />. <br />11" <br />MIN <br />2' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br />8" <br />MIN <br />25" MAX <br />2' <br />- <br />5 <br />" <br /> <br />M <br />I <br />N <br />(b) <br />toe space - general requirement <br />(a) <br />knee space - general requirement <br />9" <br />6" <br />MAX <br />projection of wall hung <br />lavatory or countertop <br />17" - 25" <br />required knee space <br />projection of wall hung <br />lavatory or countertop <br />required toe space <br />4'-0" MIN <br />CLEAR FLOOR SPACE <br />4'-0" MIN <br />CLEAR FLOOR SPACE <br />1' <br />- <br />6 <br />" <br />MI <br />N <br />4'-0" MIN <br />℄ <br /> <br />2 <br />' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />sink rim or countertop <br />lavatory; wall hung or <br />counter mounted <br />drip of the overflow <br />allowed within knee space <br />19" <br />MAX <br />17" MIN <br />25" MAX <br />clear floor space <br />required knee <br />and toe space <br /> <br />2' <br />- <br />6 <br />" <br /> <br />M <br />I <br />N <br />17" <br />MIN <br /> <br />2 <br />' <br />- <br />5 <br />" <br /> <br />M <br />I <br />N <br /> <br />2 <br />' <br />- <br />3 <br />" <br /> <br />M <br />I <br />N <br /> <br />9 <br />" <br />MI <br />N <br />8" <br />MIN. <br />6" <br />MAX <br />section plan <br />SEC. 1127A.4 GRAB BARS, TUB AND SHOWER SEATS - <br />1127 A.4 GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVICES <br />1127A.4.1 GENERAL. GRAB BARS, TUB AND SHOWER SEATS, FASTENERS AND MOUNTING DEVICES REQUIRED BY THIS <br />CHAPTER SHALL COMPLY WITH THIS SECTION. <br />1127 A.4.2 LOCATION. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL POSITION, 33 INCHES (838 MM) MINIMUM AND <br />36 INCHES (914 MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING <br />SURFACE. <br />EXCEPTION:THE HEIGHT OF THE LOWER GRAB BAR ON THE BACK WALL OF A BATHTUB SHALL COMPLY WITH SECTION <br />1127A.5.2 (see detail XX this sheet). <br />1127 A.4.3 DIAMETER OR WIDTH. THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF A GRAB BAR SHALL <br />COMPLY WITH THE FOLLOWING: <br />NOTE:SEE FIGURE 11A-9C. <br />1. CIRCULAR CROSS SECTION. GRAB BARS WITH CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE <br />DIAMETER OF 1 1/4 INCHES (32 MM) MINIMUM AND 2 INCHES (51 MM) MAXIMUM. <br />2. NON-CIRCULAR CROSS SECTION. GRAB BARS WITH NON-CIRCULAR CROSS SECTION SHALL HAVE A <br />CROSS-SECTION DIMENSION OF 2 INCHES (51 MM) MAXIMUM. THE PERIMETER DIMENSION OF GRAB BARS <br />WITH NON-CIRCULAR CROSS SECTION SHALL BE 4 INCHES ( 102 MM) MINIMUM AND 4.8 INCHES (122 MM) <br />MAXIMUM. <br />3. ALTERNATE CONFIGURATION. L-SHAPED OR U-SHAPED GRAB BARS SHALL BE PERMITTED. <br />1127A.4.4 STRUCTURAL STRENGTH. THE STRUCTURAL STRENGTH OF GRAB BARS, TUB AND SHOWER SEATS, <br />FASTENERS AND MOUNTING DEVICES SHALL MEET THE FOLLOWING SPECIFICATIONS: <br />1. BENDING STRESS IN A GRAB BAR OR SEAT INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE <br />APPLICATION OF A 250-POUND (1112 N) POINT LOAD SHALL BE LESS THAN THE ALLOWABLE STRESS FOR <br />THE MATERIAL OF THE GRAB BAR OR SEAT. <br />2. SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF A 250-POUND (1112N) POINT <br />LOAD SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE GRAB BAR OR <br />SEAT, AND IF ITS MOUNTING BRACKET OR OTHER SUPPORT IS CONSIDERED TO BE FULLY RESTRAINED, <br />THEN DIRECT AND TORSIONAL SHEAR STRESSES SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. <br />3. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE APPLICATION OF A 250-POUND <br />(1112 N) POINT LOAD SHALL BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER THE FASTENER <br />OR MOUNTING DEVICE OR THE SUPPORTING STRUCTURE, WHICHEVER IS THE SMALLER ALLOWABLE <br />LOAD. <br />4. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF A 250-POUND (1112N) POINT <br />LOAD, PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF A 250-POUND (1112 N) POINT LOAD, <br />SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN THE FASTENER AND SUPPORTING <br />STRUCTURE. <br />5. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS. <br />1127A.4.5 SURFACE. A GRAB BAR AND ANY WALL OR OTHER SURFACE ADJACENT TO IT SHALL BE FREE OF ANY SHARP <br />OR ABRASIVE ELEMENTS AND SHALL HAVE ROUNDED EDGES. <br />1127A.4.6 SPACING. WHEN GRAB BARS ARE MOUNTED ADJACENT TO A WALL, THE SPACE BETWEEN THE WALL AND <br />THE GRAB BARS SHALL BE 1 1/2 INCHES (38 MM). THE SPACE BETWEEN THE GRAB BAR AND PROJECTING <br />OBJECTS BELOW AND AT THE ENDS SHALL BE 1 1/2 INCHES (38 MM) MINIMUM. THE SPACE BETWEEN THE <br />GRAB BAR AND PROJECTING OBJECTS ABOVE SHALL BE 12 INCHES ( 305 MM) MINIMUM. (SEE FIGURE 11A-9C) <br />EXCEPTIONS: <br />1. THE SPACE BETWEEN THE GRAB BARS AND SHOWER CONTROLS, SHOWER FITTINGS, AND OTHER GRAB <br />BARS ABOVE SHALL BE PERMITTED TO BE 1 1/2 INCHES (38 MM) MINIMUM <br />2. FOR L-SHAPED OR U-SHAPED GRAB BARS THE SPACE BETWEEN THE WALLS AND THE GRAB BAR SHALL BE 1 <br />1/2 INCHES ( 38 MM) MINIMUM FOR A DISTANCE OF 6 INCHES ( 152 MM) ON EITHER SIDE OF THE INSIDE <br />CORNER BETWEEN TWO ADJACENT WALL SURFACES. <br />FIGURE 11A-9C <br />GRAB BARS <br />2" MAX <br />2" M <br />A <br />X <br />4" - 4.8" perimeter <br />(c) <br />projecting objects <br />(d) <br />recessed objects <br />1 <br />1 <br />/ <br />2 <br />" <br />MI <br />N <br />1' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />1 1/2" <br />1 1/2" <br />(a) <br />section through typical circular <br />grab bar <br />(b) <br />non-circular cross <br />sections <br />1 1/2"1 1/4" to 2" nominal <br />diameter <br />SEC. 1127A.7 SANITARY FACILITY SIGNS - <br />1127A.7 SIGNS <br />1127A.7.1 GENERAL. ALL ACCESSIBLE TOILET AND BATHING FACILITIES SHALL BE IDENTIFIED BY THE "INTERNATIONAL <br />SYMBOL OF ACCESSIBILITY. " SIGNS NEED NOT BE PROVIDED FOR FACILITIES WITHIN A DWELLING UNIT OR <br />GUESTROOM. <br />1127A.7.2 IDENTIFICATION SYMBOLS. DOORWAYS LEADING TO SANITARY FACILITIES (TOILET OR BATHING ROOMS) SHALL BE <br />IDENTIFIED BY A GEOMETRIC SYMBOL IN COMPLIANCE WITH THIS SECTION. GEOMETRIC SYMBOLS SHALL BE <br />CENTERED HORIZONTALLY ON THE DOOR AT A HEIGHT OF 58 INCHES ( 1473 MM) MINIMUM AND 60 INCHES ( 1524 <br />MM) MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE CENTER OF THE SYMBOL. WHEN A DOOR IS PRO442 <br />VIDED, THE SYMBOL SHALL BE MOUNTED WITHIN 1 INCH (25 MM) OF THE VERTICAL CENTERLINE OF THE DOOR. <br />DIRECTIONAL SIGNS INDICATING THE LOCATION OF THE NEAREST ACCESSIBLE TOILET OR BATHING ROOMS <br />SHALL BE PROVIDED. SUCH DIRECTIONAL SIGNS SHALL COMPLY WITH SECTION 1143.5 AND SHALL INCLUDE THE <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY. EDGES OF ACCESSIBILITY SIGNAGE SHALL BE ROUNDED, <br />CHAMFERED OR EASED. CORNERS SHALL HAVE A MINIMUM RADIUS OF 1INCH ( 3.2 MM). SEE SECTION 1143A FOR <br />ADDITIONAL SIGNAGE REQUIREMENTS APPLICABLE TO SANITARY FACILITIES. <br />1127A.7.2.1 MEN'S SANITARY FACILITIES. MEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY AN EQUILATERAL TRIANGLE, <br />114 INCH (6.4 MM) THICK WITH EDGES 12 INCHES (305 MM) LONG AND A VERTEX POINTING UPWARD. THE TRIANGLE <br />SYMBOL SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT <br />BACKGROUND. <br />1127A.7.2.2 WOMEN'S SANITARY FACILITIES. WOMEN'S SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 114 INCH (6.4 <br />MM) THICK AND 12 INCHES ( 305 MM) IN DIAMETER. THE CIRCLE SYMBOL SHALL CONTRAST WITH THE DOOR, <br />EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />1127A.7.2.3 UNISEX SANITARY FACILITIES. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE, 114 INCH (6.4 MM) <br />THICK AND 12 INCHES ( 305 MM) IN DIAMETER WITH A 114 INCH (6.4 MM) THICK TRIANGLE SUPERIMPOSED ON THE <br />CIRCLE AND WITHIN THE 12-INCH (305 MM) DIAMETER. THE TRIANGLE SYMBOL SHALL CONTRAST WITH THE CIRCLE <br />SYMBOL, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. THE CIRCLES SYMBOL <br />SHALL CONTRAST WITH THE DOOR, EITHER LIGHT ON A DARK BACKGROUND OR DARK ON A LIGHT BACKGROUND. <br />1' <br />- <br />0 <br />" <br />MEN'S DOOR <br />SIGNAGE <br />1'-0" <br />1'-0 <br />" <br />WOMEN'S DOOR <br />SIGNAGE <br />UNISEX DOOR <br />SIGNAGE <br />1' <br />- <br />0 <br />" <br />SEC. 1127A.8 TOILET FIXTURES AND ACCESSORIES - <br />1127A.8 TOILET ROOM FIXTURES AND ACCESSORIES <br />1127 A.8.1 TOWEL, SANITARY NAPKINS, WASTE RECEPTACLES. WHERE TOWEL, SANITARY NAPKINS, WASTE <br />RECEPTACLES AND OTHER SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF <br />EACH TYPE SHALL BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40 INCHES <br />(1016 MM)FROM THE FINISHED FLOOR. CONTROLS AND OPERATING MECHANISMS SHALL COMPLY WITH <br />SECTION 1138A.4 (see detail XX / XXX). <br />1127A.8.2 TOILET TISSUE DISPENSERS. TOILET TISSUE DISPENSERS SHALL BE LOCATED ON THE WALL OR PARTITION <br />CLOSEST TO THE WATER CLOSET, 7 INCHES ( 180 MM) MINIMUM AND 9 INCHES (230 MM) MAXIMUM IN FRONT <br />OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE <br />DISPENSER SHALL BE BELOW THE GRAB BAR, 19 INCHES (483 MM) MINIMUM ABOVE THE FINISH FLOOR. THE <br />OUTLET OF THE DISPENSER SHALL NOT BE LOCATED BEHIND GRAB BARS. DISPENSERS SHALL NOT BE OF A <br />TYPE THAT CONTROLS DELIVERY OR THAT DOES NOT ALLOW CONTINUOUS PAPER FLOW. (SEE FIGURE <br />11A-9B) <br />1127A.8.3 MIRRORS. WHERE MIRRORS ARE PROVIDED, AT LEAST ONE SHALL BE ACCESSIBLE. MIRRORS LOCATED <br />ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING <br />SURFACE 40 INCHES (1016 MM) MAXIMUM ABOVE THE FINISH FLOOR. MIRRORS NOT LOCATED ABOVE <br />LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING <br />SURFACE 35 INCHES (889 MM) MAXIMUM ABOVE THE FINISH FLOOR. <br />4'-6" MIN <br />1'-0" <br />MAX 3'-6" MIN <br />(a) <br />dispensers <br /> 1' <br />- <br />7 <br />" <br />MI <br />N <br />7" - 9" <br />℄ <br />℄ <br />17 <br />" <br />- <br /> <br />1 <br />9 <br />" <br />33 <br />" <br /> <br />- <br /> <br />3 <br />6 <br />" <br /> 3' <br />- <br />4 <br />" <br /> <br />M <br />A <br />X <br />℄ <br />FIGURE 11A-9B <br />(b) <br />mirrors <br /> 3' <br />- <br />4 <br />" <br /> <br />M <br />A <br />X <br /> 2' <br />- <br />1 <br />1 <br />" <br /> <br />M <br />A <br />X <br />mirror <br />reflective <br />surface <br />mirror above <br />lavatory or <br />countertop <br />highest operable <br />part within 40" of <br />the finish floor <br />typical <br />3 2 1 <br />45 <br />6