UP 18R <br />@6.72" EA. <br />DN 18R <br />@6.72" EA. <br />IDF <br />IDF <br />UP <br /> <br />1 <br />8 <br />R <br />@6 <br />. <br />7 <br />2 <br />" <br /> <br />E <br />A <br />. <br />DN <br /> <br />1 <br />8 <br />R <br />@6 <br />. <br />7 <br />2 <br />" <br /> <br />E <br />A <br />. <br />OPEN TO <br />BELOW <br />OPEN TO <br />BELOW <br />OPEN TO BELOW <br />LOBBY <br />9'-1" <br />BALC. <br />ELEV. <br />STAIR 1 <br />STAIR 3 <br />TRASH <br />BALC.BALC. <br />MASTER <br />BEDROOM <br />9'-1" <br />LIVING <br />9'-1" <br />DINING <br />9'-1" <br />KITCHEN <br />9'-1" <br />BATH 2 <br />9'-1" <br />BEDROOM 2 <br />9'-1" <br />BATH <br />9'-0" <br />BEDROOM <br />9'-1" <br />KITCHEN <br />9'-0" <br />LIVING / <br />DINING <br />9'-1" <br />BALC. <br />LIVING / <br />DINING <br />9'-1" <br />LIVING / <br />DINING <br />9'-1" <br />KITCHEN <br />9'-0" <br />BATH <br />9'-0" <br />BATH <br />9'-0" <br />KITCHEN <br />9'-1" <br />KITCHEN <br />9'-1" <br />BATH <br />9'-1" <br />BATH <br />9'-1" <br />KITCHEN <br />9'-1" <br />BEDROOM <br />9'-1" <br />BEDROOM <br />9'-1" <br />BEDROOM <br />9'-1" <br />BEDROOM <br />9'-1" <br />BALC.BALC.BALC.BALC. <br />BEDROOM <br />9'-1" <br />LIVING / <br />DINING <br />9'-1" <br />KITCHEN <br />9'-1" <br />BATH <br />9'-1" <br />W.I.C. <br />9'-1" <br />MASTER <br />BEDROOM <br />9'-1" <br />BEDROOM <br />9'-1" <br />LIVING <br />9'-1"KITCHEN <br />9'-1" <br />DINING <br />9'-1" <br />M. BATH <br />9'-1" <br />M. BATH <br />9'-1"BATH <br />9'-1" <br />CORRIDOR <br />9'-1" <br />LIVING / <br />DINING <br />9'-1" <br />LIVING / <br />DINING <br />9'-1" <br />142'- <br />1 <br />1 <br />" <br /> <br />L <br />O <br />N <br />G <br />E <br />S <br />T <br /> <br />D <br />I <br />A <br />G <br />O <br />N <br />A <br />L <br />103'-7" EXIT <br /> <br />S <br />E <br />P <br />A <br />R <br />A <br />T <br />I <br />O <br />N <br /> <br />( <br />> <br />1 <br />/ <br />3 <br /> <br />D <br />I <br />A <br />G <br />O <br />N <br />A <br />L <br />) <br />PATH 3M1 <br />PATH 3M2 <br />PATH 3M3 <br />303 <br />304 <br />305 <br />306 PATH 3M4 <br />307 PATH 3M5 <br />309 PATH 3M6 <br />311 <br />312 <br />PATH 3M7 <br />PATH 3M8 <br />EGRESS DATA - LEVEL 3 <br />EATDCPOET <br />34'-9" <br />46'-9" <br />34'-9" <br />PATHRM # <br />73'-3"34'-9" <br />33'-9"69'-2" <br />34'-9"63'-3" <br />98'-6" <br />90'-4" <br />77'-10" <br />71'-0"46'-9" <br />48'-3"34'-9" <br />PATH 3M2 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />1 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />3 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />5 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />6 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />7 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />4 <br />PA <br />T <br />H <br /> <br />3 <br />M <br />8 <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />THIRD LEVEL - EXITING PLAN <br />OCCUPANT LOAD SIGN - 2022 CBC 1004.1: <br />FOR ASSEMBLY ROOMS OR AREA OF SIMILAR USAGE, PROVIDE A SIGN STATING <br />"MAXIMUM OCCUPANT LOAD" PERMANENTLY POSTED NEAR THE MAIN EXIT FROM THE <br />ASSEMBLY ROOM. THE SIGN SHALL BE LEGIBLE WITH LETTERS THAT ARE CONTRASTING <br />IN COLOR WITH THE BACKGROUND. <br />EGRESS ILLUMINATION - 2022 CBC 1013.3: <br />THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT-CANDLE <br />AT THE WALKING SURFACE. MEANS OF EGRESS ILLUMINATION SHALL BE PROVIDED <br />FROM AN EMERGENCY POWER SYSTEM. <br />ACCESSIBLE MEANS OF EGRESS - 2022 CBC 1011.2: <br />INTERIOR EXIT STAIRWAYS AND HORIZONTAL EXITS ARE USED TO PROVIDE ACCESSIBLE <br />MEANS OF EGRESS FOR THE PROJECT. THE PROJECT HAS A SPRINKLER SYSTEM IN <br />ACCORDANCE WITH 903.3.1.1 AND THEREFORE, STAIRWAYS WILL BE 44 INCHES WIDE <br />AND AREAS OF REFUGE ARE NOT REQUIRED. <br />TACTILE EXIT SIGNS - 2022 CBC 1013.1: <br />EXIT SIGNS SHALL READ: <br />"EXIT" AT GRADE LEVEL EXTERIOR EXIT DOOR <br />"EXIT STAIR DOWN", "EXIT RAMP DOWN", "EXIT STAIR UP", "EXIT RAMP UP" AT EACH EXIT <br />DOOR THAT LEADS DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT DOOR BY A STAIRWAY <br />OR RAMP AS APPROPRIATE. <br />"EXIT ROUTE" AT EXIT DOORS THAT LEAD TO A GRADE LEVEL EXTERIOR EXIT BY MEANS <br />OF AN EXIT ENCLOSURE OR AN EXIT PASSAGEWAY. <br />"EXIT ROUTE" AT INTERIOR ROOM DOOR OR AREA TO A CORRIDOR OR HALLWAY. <br />"TO EXIT" AT AN EXIT DOOR THROUGH A HORIZONTAL EXIT. <br />LEGEND <br />EXITING GENERAL NOTES <br />EXIT SIGNS - 2022 CBC 1013.1: <br />EXIT SIGNS SHALL BE PLACED AT 100 FEET MAXIMUM WITHIN THE EXIT ACCESS <br />CORRIDOR AND EXIT PASSAGEWAY. <br />1 ACCESSIBLE ELEVATOR, PROVIDE MITSUBISHI ELEVATORS (35000 LBS), DIAMOND TRAC SERIES. PROVIDE <br />TWO-WAY COMMUNICATION SYSTEM IN ACCORDANCE WITH CBC SECTION 1007.8. NEW ELEVATORS SHALL <br />BE PROVIDED WITH PHASE ONE EMERGENCY RECALL OPERATION AND PHASE TWO EMERGENCY IN-CAR <br />OPERATION IN ACCORDANCE WITH ASME A17.1 PROVIDE ELEVATOR SHAFT VENT AT TOP OF ELEVATOR <br />SHAFT/HOISTWAY PER CDC 3004.2 (IF CONTRACTOR PROPOSES A CHANGE AND IT IS ACCEPTED BY THE <br />OWNER, CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGN SERVICES REQUIRED AS A RESULT OF THE <br />CHANGE INCLUDING IMPACT ON OTHER SYSTEMS OR THE DESIGN OF ADJACENT SPACES. CONTRACTOR <br />SHALL BE RESPONSIBLE FOR THE IMPACT OF ANY CHANGE, FORESEEN OR NOT. THE IMPACT OF AN <br />CHANGE SHALL BE COMMUNICATED TO THE DESIGN TEAM/OWNER PRIOR TO ACCEPTANCE BY THE OWNER) <br />ELEVATOR LOBBIES AT THE LEVELS OF EXIT DISCHARGE ARE NOT ENCLOSED (CBC SECT. 713.14.1, <br />EXCEPTION 1). ENCLOSED ELEVATOR LOBBIES ARE NOT PROVIDED ON OTHER LEVELS (CBC SECT. 713.14.1, <br />EXCEPTION 8). HOISTWAY DOOR OPENING IS PROTECTED BY A LISTED AND LABELED SMOKE CONTAINMENT <br />SYSTEM COMPLYING WITH ICC ES AC 77. <br />2 BUILDING STORAGE ROOMS, SUCH AS RESIDENTIAL STORAGE, IF AVAILABLE TO TENANT USE, SHALL HAVE <br />AT LEAST ONE OF EACH TYPE OF STORAGE COMPLYING WITH CBC 2022 SECT. 1127A.11. ACCESSIBLE <br />STORAGE ROOMS SHALL BE LOCATED ON AN ACCESSIBLE ROUTE AND MUST PROVIDE AN ACCESSIBLE <br />ENTRANCE. LIGHT SWITCHES MUST ALSO BE LOCATED WITHIN AN ACCESSIBLE REACH RANGE WITHIN <br />STORAGE ROOM. <br />EXITING KEY NOTES <br />1 1-HR WALL ASSEMBLY - 2x4 OR 2x6 WOOD STUDS AT 16" O.C. WITH ONE <br />LAYER 5/8" TYPE 'X' GYP. BD. ON ONE SIDE, ONE LAYER 5/8" TYPE 'X' GYP. <br />BD. OVER 1 2" RESILIENT CHANNELS ON THE OPPOSITE SIDE & 3 12" BATT <br />INSUL. WALL SHALL EXTEND FROM FLOOR TO BOTTOM OF WOOD DECK <br />ABOVE UNLESS NOTED OTHERWISE. SHEAR WALLS WILL HAVE 1 2" <br />PLYWOOD SHEATHING UNDER GYP. BD. AND / OR SHEATHING - SEE <br />STRUCT. - U.L. DES. NO. U309 (STC=50) - SEE TYPICAL DETAIL 16/A9.0 <br />3 1-HR PARTY WALL ASSEMBLY - DBL. 2x6 STUDS AT 16" O.C. (2" SPACE <br />BETWEEN) WITH ONE LAYER 5/8", TYPE 'X' GYP. BD. & 3 1 2" BATT INSUL. <br />ON EACH SIDE OF WALL ASSEMBLY. WALLS SHALL EXTEND FROM FLOOR <br />TO BOTTOM OF WOOD DECK ABOVE UNLESS NOTED OTHERWISE. U.L. <br />DESIGN NO. U305 (STC=56) - SEE TYPICAL DETAIL 3/A9.0 <br />4 1-HR OR 2-HR CMU FIRE BARRIER WALL ASSEMBLY (6" CMU GROUTED <br />SOLID) - CALIFORNIA BUILDING CODE TABLE 721.1(2) - ITEM NO. 3-1.2 - <br />WALL WILL HAVE FURRING PER CONDITION - SEE WALL TYPES. <br /> 1-HR MIN. EQUIVALENT THICKNESS = 2.6" (STC 52) <br /> 2-HR MIN. EQUIVALENT THICKNESS = 3.6" (STC 52) <br />6 3-HR FLOOR-CEILING ASSEMBLY - LIGHT WEIGHT CONCRETE OVER 2" <br />METAL DECK (CONC. MUST BE 2 12" ABOVE FLUTES). SPRAY-ON <br />FIRE-PROOFING IS ADDED TO THE UNDERSIDE OF THE METAL DECK <br />AND TO STEEL BEAMS SUPPORTING THE DECK (THICKNESS IS <br />DEPENDENT ON MANUFACTURER) - U.L. DESIGN NO. D701 <br />7 <br />FIRE RESISTIVE ASSEMBLIES <br />1-HR GYP. BD. COLUMN PROTECTION FOR ALL STEEL COLUMNS PER DETAILS ON SHEET <br />A9.1 - U.L. DESIGN NO. X528 <br />2 1-HR WALL ASSEMBLY - 3 5 8" x 20 GA. OR 6' x 20 GA. METAL STUDS AT <br />16" O.C. WITH 3 12" BATT INSUL. AND ONE LAYER 5/8" TYPE 'X' GYP. BD. <br />EACH SIDE. WALLS SHALL EXTEND FROM FLOOR TO BOTTOM OF CONC. <br />DECK ABOVE UNLESS NOTED OTHERWISE. - U.L. DES. NO. U419 <br />(STC=50) <br />5 1-HR FLOOR-CEILING ASSEMBLY - MINIMUM 9 1/2" WOOD I-JOISTS <br />AT 16" O.C. WITH 3 4" PLYWOOD AND + 3 4" ACOUSTI-MAT + 1 1/2" <br />LIGHTWEIGHT CONCRETE ON TOP AND TWO LAYERS 5/8", TYPE 'X' <br />GYP. BD. ON RSIC-1 ACOUSTICAL CHANNELS BELOW- U.L. DESIGN <br />NO. L518 (STC 55) & (IIC 60) <br />8 1-HR ROOF-CEILING ASSEMBLY - SINGLE-PLY ROOFING SYSTEM OVER SLOPED RIGID <br />INSULATION OVER 3 4" PLYWOOD DECK ON TOP SIDE OVER 2x12 JOISTS AT 16" O.C. - ON <br />BOTTOM SIDE 2 LAYERS 5 8" TYPE 'X' GYP. BD. ON 7 8" FURRING CHANNELS <br />PERPENDICULAR TO JOISTS AT 24" O.C. - U.L. DESIGN NO. L541 <br />12 2-HR WALL ASSEMBLY - 3 5 8" x 20 GA. OR 6' x 20 GA. METAL STUDS AT 16" O.C. WITH 3 1 2" <br />BATT INSUL. AND 2 LAYERS 5/8" TYPE 'X' GYP. BD. EACH SIDE. WALLS SHALL EXTEND <br />FROM FLOOR TO BOTTOM OF CONC. DECK ABOVE UNLESS NOTED OTHERWISE. - G.A. <br />FILE. NO. WP 1548 (STC=54) <br />10 2-HR WALL SHAFT WALL ASSEMBLY - 4" x 20 GA. 20 GA. C-H METAL STUDS AT 24" O.C. <br />WITH 3" BATT INSUL., 2 LAYERS 5/8" TYPE 'X' GYP. BD. ON ROOM SIDE AND 1" TYPE 'X' <br />LINER PANEL ON SHAFT SIDE. WALLS SHALL EXTEND FROM FLOOR TO BOTTOM OF <br />WOOD DECK ABOVE UNLESS NOTED OTHERWISE. - G.A. FILE. NO. WP 7051 (STC=54) <br />11 3-HR WALL WALL ASSEMBLY - 2 1 2" x 20 GA. C-H METAL STUDS AT 24" O.C. WITH 3 LAYERS <br />5/8" TYPE 'X' GYP. BD. ON EXTERIOR AND 1" TYPE 'X' LINER PANEL ON BUILDING SIDE. <br />WALLS BE ON OUT SIDE OF SHEAR WALLS. EXTERIOR FINISH SHALL BE 7 8" CEMENT <br />PLASTER SYSTEM - G.A. FILE. NO. WP 7051 - SEE TYPICAL DETAIL 20/A9.0 <br />5A 1-HR FLOOR-CEILING ASSEMBLY - MINIMUM 2x10 WOOD I-JOISTS <br />AT 16" O.C. WITH 3 4" PLYWOOD AND + 3 4" ACOUSTI-MAT + 1 1/2" <br />LIGHTWEIGHT CONCRETE ON TOP AND TWO LAYERS 5/8", TYPE 'X' <br />GYP. BD. ON RSIC-1 ACOUSTICAL CHANNELS BELOW- U.L. DESIGN <br />NO. L541 (STC 55) & (IIC 60) <br />9 2-HR WALL ASSEMBLY - 2 x 6 WOOD STUDS AT 16" O.C. WITH 5 1 2" BATT INSULATION. <br />PROVIDE 2 LAYERS 5/8" TYPE 'X' GYP. BD. ON STAIR SIDE AND 2 LAYERS 5/8" TYPE 'X' GYP. <br />BD. ON 7 8" x 25 GA. HORIZONTAL FURRING CHANNELS ON ROOM SIDE. WALLS SHALL <br />EXTEND FROM FLOOR TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE. - U.L. <br />DESIGN NO. U301 (STC=55) <br />13 2-HR EXTERIOR WALL ASSEMBLY - 2 x 6 WOOD STUDS AT 16" O.C. WITH R-19 BATT INSUL., <br />2 LAYERS 5/8" TYPE 'X' GYP. BD. ON INTERIOR AND ONE LAYER 5 8", TYPE 'X' GYP. <br />SHEATHING + 7 8 CEMENT PLASTER ASSEMBLY ON THE EXTERIOR. WALLS SHALL EXTEND <br />FROM FLOOR TO BOTTOM OF DECK ABOVE UNLESS NOTED OTHERWISE. - G.A. FILE. NO. <br />WP 8417 <br />3 EXIT SIGNAGE. SEE DETAIL 27/A0.11. EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF <br />APPROACH. EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE DIRECTION OF <br />EGRESS TRAVEL. NO POINT SHALL BE MORE THAN 100 FEET FROM THE NEAREST VISIBLE SIGN (1001) <br />USE SIGNAGE "EXIT ENROUTE" AT BASEMENT LEVEL 2 AND BASEMENT LEVEL 1A <br />USE SIGNAGE "EXIT" AT LEVEL 1B <br />USE SIGNAGE "EXIT STAIR DOWN" AT LEVEL 2-4C REFER TO SHEET A0.4 UNDER FIRE DEPARTMENT NOTES FOR ADDITIONAL <br />INFORMATION REGARDING EXITING REQUIREMENTS <br />INTERIOR-FLAME RETARDANCE <br />INTERIOR WALL & CEILING FINISH REQUIREMENTS BY OCCUPANCY FOR <br />GROUPS A-3 (ROOMS AND ENCLOSED SPACES), R-2 & S IS CLASS C (TABLE 803.9) <br />1. INTERIOR WALL AND CEILING FINISHES FOR LOBBY SPACES SHALL NOT EXCEED A <br />FLAME-SPREAD CLASSIFICATION OF 200 (CLASS III) <br />2. INTERIOR WALL AND CEILING FINISHES FOR EXIT CORRIDORS SHALL NOT <br />EXCEED A FLAME-SPREAD CLASSIFICATION OF 75 (CLASS III) <br />3. INTERIOR WALL AND CEILING FINISHES FOR STAIRWAYS SHALL NOT EXCEED A <br />FLAME-SPREAD CLASSIFICATION OF 25 (CLASS III) <br />4. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME-RETARDANT <br />TREATED IN APPROVED MANNER (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) <br />101 <br />A1 <br />THE TOP NUMBER INDICATES INDIVIDUAL UNIT NUMBER FOR <br />COORDINATION AND IDENTIFICATION OF UNIT DURING <br />CONSTRUCTION. CONTRACTOR TO PROVIDE THIS NUMBER <br />AFFIXED AND MAINTAINED AT EACH UNITS MAIN ENTRY DOOR <br />THROUGH THE DURATION OF CONSTRUCTION. <br />THE BOTTOM NUMBER INDICATES UNIT PLAN TYPE. <br />R = REVERSE PLAN. <br />EXIT PATH OF TRAVEL CBC SEC 1016 <br />COMMON PATH OF EGRESS TRAVEL CBC SEC 1014.3 <br />250'-0" MAX <br />GROUP R2 = 125'-0" MAX <br />GROUP S and B = 100'-0" MAX <br />"COMMON PATH OF EGRESS TRAVEL" SHALL BE <br />INCLUDED WITHIN THE PERMITTED TRAVEL DISTANCE <br />INDICATES SEMI-RECESSED FIRE EXTINGUISHER CAB. AT BUILDING <br />LEVELS & WALL-MOUNTED FIRE EXTINGUISHER AT GROUND LEVEL, <br />POTTER ROEMER #7032 OR EQ. W/ SOLID DOOR COMBINATION <br />2A-10ABC F.E.. LOCATE F.E. SO THAT FROM ANY POINT WITHIN THE <br />BLDG AN F.E. IS NOT MORE THAN 75' OF TRAVEL DISTANCE. <br />VERIFY PROPOSED LOCATIONS AND QUANTITY AND TYPE OF CAB. <br />W/ THE FIRE INSPECTOR PRIOR TO PURCHASE AND INSTALL. <br />250 FEET MAX. TRAVEL TO EXIT <br />ACCESS COMPONENT (TO STAIR) <br />PATH EATD = EXIT ACCESS TRAVEL DISTANCE <br />CPOET = COMMON PATH OF EGRESS TRAVEL <br />UNIT NUMBER <br />UNIT TYPE (A = "U" SHAPE KITCHENS) <br />PROPERTY LINE <br />1 HOUR WALL ASSEMBLY - SEE FIRE RESISTIVE <br />ASSEMBLIES <br />2 HOUR WALL ASSEMBLY - SEE FIRE RESISTIVE <br />ASSEMBLIES <br />60 OPENING RATING (IN MINUTES) <br />A-2 <br />OCCUPANCY GROUPS <br />S-2 <br />R-2 <br />RATED WALL ASSEMBLIES <br />GROUP A over 50 OCCUPANTS = 30'-0" MAX. <br />F.E. <br />U <br />WET STANDPIPE, CLASS 1, FOR FIRE DEPARTMENT USE. <br />SEE FIRE PROTECTION DWGS BY OTHERS FOR ADDITIONAL <br />INFO. AND DETAILS. <br />1.OCFA FINAL INSPECTION REQUIRED. PLEASE SCHEDULE ALL FIELD INSPECTIONS AT LEAST 48 <br />HOURS IN ADVANCE. INSPECTIONS CANCELED AFTER 1 P.M. ON THE DAY BEFORE THE <br />SCHEDULED DATE WILL BE SUBJECT TO A REINSPECTION FEE. PHASING OF INSPECTIONS <br />MAY REQUIRE ADDITIONAL FEES, ALSO. CALL OCFA INSPECTION SCHEDULING AT <br />714-573-6150. <br />2.BUILDINGS UNDER CONSTRUCTION OR DEMOLITION SHALL CONFORM TO CFC CHAPTER 33. <br />NO SMOKING OR COOKING IS ALLOWED IN STRUCTURES WHERE COMBUSTIBLE MATERIALS <br />ARE EXPOSED OR WITHIN 25 FEET OF COMBUSTIBLE MATERIALS STORAGE AREAS. CUTTING, <br />WELDING, OR OTHER HOT WORK SHALL BE IN CONFORMANCE WITH CFC CHAPTER 35. <br />3.IN BUILDINGS FOUR OR MORE STORIES IN HEIGHT, STANDPIPES SHALL BE PROVIDED DURING <br />CONSTRUCTION WHEN THE HEIGHT REACHES 40 FEET ABOVE THE LOWEST POINT OF FIRE <br />DEPARTMENT ACCESS. A FIRE DEPARTMENT CONNECTION SHALL BE NO MORE THAN 100 <br />FEET FROM AVAILABLE FIRE DEPARTMENT VEHICLE ACCESS ROADWAYS. A HYDRANT SHALL <br />BE LOCATED ALONG THE ACCESS ROADWAY WITHIN 150 FEET OF THE LOCATION(S) THAT THE <br />FDC CAN BE ACCESSED FROM. CFC 3310, 3313 <br />4.ADDRESS NUMBERS SHALL BE PROVIDED FOR ALL NEW AND EXISTIONG BUILDINGS, BE A <br />MINIMUM OF 4 INCHES HIGH FOR INDIVIDUAL DWELLING UNITS AND 6 INCHES HIGH FOR ALL <br />OTHER INSTALLATIONS AND STRUCTURES, CONTRAST WITH THEIR BACKGROUND, AND BE <br />PLAINLY VISIBLE FROM THE ROADWAY THE BUILDING IS ADDRESSED ON. TEMPORARY <br />ADDRESS NUMBERS SHALL BE PROVIDED ON CONSTRUCTION FENCING OR THE BUILDING <br />UNTIL PERMANENT NUMBERS CAN BE PROVIDED. CBC 501.2, CFC 505.1 <br />5.LOCATIONS AND CLASSIFICATIONS OF EXTINGUISHERS SHALL BE IN ACCORDANCE WITH CFC <br />906 AND CCR TITLE 19. AT LEAST ONE EXTINGUISHER SHALL BE PROVIDED DURING <br />CONSTRUCTION ON EACH FLOOR AT EACH STAIRWAY, IN EACH STORAGE AND <br />CONSTRUCTION SHED, IN LOCATIONS WHERE FLAMMABLE OR COMBUSTIBLE LIQUIDS ARE <br />STORED OR USED, OR WHERE SIMILAR HAZARDS ARE PRESENT PER CFC 3315.1. BEFORE <br />FINAL OCCUPANCY, AT LEAST ONE 2A:10B:C EXTINGUISHER SHALL BE PROVIDED SO THAT NO <br />POINT IS MORE THAN 75 FEET TRAVEL DISTANCE FROM THE EXTINGUISHER. EXTINGUISHERS <br />SHALL BE LOCATED ALONG THE PATH OF EGRESS TRAVEL AND IN A READILY VISIBLE AND <br />ACCESSIBLE LOCATION, WITH THE BOTTOM OF THE EXTINGUISHER AT LEAST 4 INCHES <br />ABOVE THE FLOOR. ADDITIONAL EXTINGUISHERS MAY BE REQUIRED BY OCFA INSPECTORS <br />DEPENDING ON PROJECT OR SITE CONDITIONS AND FINAL PLACEMENT IS SUBJECT TO THEIR <br />APPROVAL. <br />6.WALL, FLOOR AND CEILING FINISHES AND MATERIALS SHALL NOT EXCEED THE FLAME <br />SPREAD CLASSIFICATIONS IN CBC TABLE 803.11. DECORATIVE MATERIALS SHALL BE <br />PROPERLY TREATED BY A PRODUCT OR PROCESS APPROVED BY THE STATE FIRE MARSHAL <br />WITH APPROPRIATE DOCUMENTATION PROVIDED TO THE OCFA. SUCH ITEMS SHALL BE <br />APPROVED AND INSPECTED BY THE OCFA PRIOR TO INSTALLATION. <br />7.KNOX BOXES/KEY CABINETS SHALL BE PROVIDED FOR ALL HIGH-RISE BUILDINGS, POOL <br />ENCLOSURES, GATES IN THE PATH OF FIREFIGHTER TRAVEL TO STRUCTURES, SECURED <br />PARKING LEVELS, DOORS GIVING ACCESS TO ALARM PANELS AND/OR ANNUNCIATORS, AND <br />ANY OTHER STRUCTURES OR AREAS WHERE IMMEDIATE ACCESS IS REQUIRED OR IS UNDULY <br />DIFFICULT. AN OCFA INSPECTOR CAN ASASIST WITH LOCKING GATE KEYS IN KNOX BOXES, <br />CONTACT YOUR LOCAL FIRE STATION TO ARRANGE AN APPOINTMENT TO SECURE MASTER <br />BUILDING KEYS IN THE KNOX BOX. <br />8.APPROVAL OF THESE PLANS SHALL NOT PERMIT THE VIOLATION OF ANY CODE OR LAW. <br />REQUIREMENTS OR FEATURES NOT IDENTIFIED ON THE PLAN MAY APPLY AND OCFA <br />INSPECTORS MAY REQUIRE ADDITIONAL INFORMATION OR ITEMS FROM THOSE SHOWN ON <br />THE PLAN DEPENDING ON ACTUAL OR ANTICIPATED FIELD CONDITIONS. SUCH CHANGES MAY <br />NECESSITATE SUBMITTAL OF REVISED OR AS-BUILT PLANS TO THE OCFA AND THE <br />CITY/COUNTY WHERE THE PROJECT IS LOCATED. <br />9.THE PROJECT SHALL COMPLY WITH 2022 CALIFORNIA BUILDING CODE, 2022 CALIFORNIA FIRE <br />CODE, AND OTHER CURRENTLY ADOPTED CODES, STANDARDS, REGULATIONS AND <br />REQUIREMENTS AS ENFORCED BY THE OCFA. <br />10.APPROVAL OF THIS PLAN IS CONTINGENT UPON A CERTIFICATE OF OCCUPANCY BEING <br />ISSUED UPON COMPLETION OF ALL CONSTRUCTION ON THE ENTIRE PROJECT. PHASED <br />OCCUPANCY SHALL BE PERMITTED ONLY WITH PRIOR APPROVAL FROM OCFA AND THE <br />BUILDING OFFICIAL. REQUESTS FOR PHASED OCCUPANCY SHALL BE SUBMITTED TO OCFA <br />FOR EVALUATION AS AN ALTERNATE MATERIALS AND METHODS PROPOSAL ACCOMPANYING <br />THE ARCHITECTURAL SUBMITTAL. SUCH REQUESTS SHALL BE MADE PRIOR TO START OF <br />CONSTRUCTION ONLY. <br />11.DUMPSTERS AND TRASH CONTAINERS EXCEEDING 1.5 CUBIC YARDS SHALL NOT BE STORED <br />IN BUILDINGS OR PLACED WITHIN 5 FEET OF COMBUSTIBLE WALLS, OPENINGS OR <br />COMBUSTIBLE ROOF EAVE LINES UNLESS PROTECTED BY AN APPROVED SPRINKLER SYSTEM <br />OR LOCATED IN A TYPE I OR IIA STRUCTURE SEPARATED BY 10 FEET FROM OTHER <br />STRUCTURES. CONTAINERS LARGER THAN 1 CUBIC YARD SHALL BE OF NON- OR <br />LIMITED-COMBUSTIBLE MATERIALS OR SIMILARLY PROTECTED OR SEPARATED. CFC 304.3. <br />12.EXITS, EXIT SIGNS, FIRE ALARM PANELS, HOSE CABINETS, FIRE EXTINGUISHER LOCATIONS, <br />AND STANDPIPE CONNECTIONS SHALL NOT BE CONCEALED BY CURTAINS, MIRRORS, OR <br />OTHER DECORATIVE MATERIAL. <br />13.THE EGRESS PATH SHALL REMAIN FREE AND CLEAR OF ALL OBSTRUCTIONS AT ALL TIMES. <br />NO STORAGE IS PERMITTED IN AISLES. <br />14.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY <br />SPECIAL KNOWLEDGE OR EFFORT. DOORS SHALL NOT BE PROVIDED WITH THUMB-TURN <br />LOCKS OR DEADBOLTS THAT DO NOT UNLATCH IN TANDEM WITH THE NORMAL OPERATING <br />LEVER. THE OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSERS SHALL NOT EXCEED <br />5 POUNDS. THE UNLATCHING AND OPENING FORCE FOR OTHER DOORS, INCLUDING FIRE <br />DOORS, SHALL NOT EXCEED 15 POUNDS. CBC 1010. <br />15.THE EXIT PATH SHALL BE CLEARLY IDENTIFIED WITH EXIT SIGNS CONFORMING TO CBC 1013. <br />ILLUMINATED EXIT SIGNS MUST HAVE 90-MINUTE EMERGENCY POWER BACK-UP. <br />16.STAIRS SERVING 4+ STORIES SHALL HAVE STAIRWELL SIGNS CONFORMING TO CBC 1023.9 <br />AND OCFA GUIDELINE E-02. <br />17.THE EXIT PATH SHALL BE ILLUMINATED AT ALL TIMES IN ACCORDANCE WITH CBC 1006. <br />EMERGENCY LIGHTING SHALL BE PROVIDED WITH 90-MINUTE BACK-UP. <br />18.RATED ASSEMBLIES SHALL CONFORM TO APPROVED METHODS AND MATERIALS OF <br />CONSTRUCTION. PENETRATIONS THROUGH RATED WALLS, CEILINGS, OR FLOORS SHALL BE <br />PROTECTED IN AN APPROVED MANNER COMPLYING WITH CBC/CFC CHAPTER 7. <br />19.RATED DOORS SHALL BE SELF-CLOSING AND LATCHING; SUCH DOORS SHALL NOT BE <br />EQUIPPED WITH DOOR STOPS OR OTHERWISE PROPPED OPEN. RATED DOORS SHALL BE <br />EQUIPPED WITH RATED HARDWARE. CFC 703. <br />20.OCCUPANT LOAD SIGN, WITH MINIMUM ONE-INCH LETTERS AND NUMBERS CONTRASTING <br />WITH THEIR BACKGROUND, SHALL BE POSTED IN A CONSPICUOUS LOCATION NEAR THE MAIN <br />EXIT PER CBC 1004.3 AND TITLE 19 3.30. WHERE MULTIPLE SEATING CONFIGURATIONS OR <br />USES ARE ANTICIPATED, SEATING DIAGRAMS AND THEIR RESPECTIVE OCCUPANT LOADS MAY <br />ALSO BE REQUIRED TO BE POSTED. <br />21.PANIC HARDWARE SHALL BE PROVIDED FOR ALL EXIT AND EXIT ACCESS DOORS IN <br />ASSEMBLY OCCUPANCIES. SUCH DOORS SHALL SWING IN THE DIRECTION OF EXIT TRAVEL. <br />DOORS EQUIPPED WITH PANIC HARDWARE SHALL HAVE NO OTHER LOCK OR LATCH EXCEPT <br />PANIC HARDWARE. IF PANIC HARDWARE IS OMITTED ON THE MAIN DOOR WHEN PERMITTED <br />BY CBC 1010.1.9.3, A SIGN STATING "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS <br />OCCUPIED" IN MINIMUM 1-INCH LETTERS CONTRASTING WITH THEIR BACKGROUND SHALL BE <br />POSTED IN A CONSPICUOUS LOCATION ON OR ADJACENT TO THE DOOR AND THE DOOR <br />SHALL BE EQUIPPED ONLY WITH A KEY-OPERATED LOCK THAT VISUALLY INDICATES <br />WHETHER IT IS OPEN OR LOCKED. <br />22.AN AUTOMATIC FIRE SPRINKLER SYSTEM SHALL BE PROVIDED THROUGHOUT THE BUILDING <br />IN COMPLIANCE WITH CFC 903 AND THE APPLICABLE 2016 NFPA SPRINKLER STANDARD. <br />REVIEW AND APPROVAL OF A SPRINKLER PLAN IS REQUIRED PRIOR TO INSTALLATION OR <br />MODIFICATION. <br />23.AN AUTOMATIC EXTINGUISHING SYSTEM SHALL BE PROVIDED TO PROTECT <br />COMMERCIAL-TYPE FOOD HEATING EQUIPMENT THAT PRODUCES GREASE-LADEN VAPORS <br />AND SHALL COMPLY WITH 2016 CFC AND CMC AND 2009 NFPA 17A. REVIEW AND APPROVAL OF <br />A HOOD AND DUCT EXTINGUISHING SYSTEM PLAN IS REQUIRED PRIOR TO INSTALLATION OR <br />USE OF COOKING EQUIPMENT. <br />24.A FIRE ALARM SYSTEM SHALL BE PROVIDED IN COMPLIANCE WITH CBC/CFC 907 AND 2016 <br />NFPA 72. A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR APPROVAL PRIOR TO <br />INSTALLATION OR MODIFICATION. <br />25.AUTOMATIC FIRE SPRINKLER SYSTEM(S) AND ALL CONTROL VALVES, WITH THE EXCEPTION <br />OF THOSE LISTED IN CFC 903.4, SHALL BE MONITORED BY A UL LISTED CENTRAL ALARM <br />STATION. <br />26.AT LEAST ONE EMERGENCY ESCAPE AND RESCUE WINDOW SHALL BE PROVIDED FOR EVERY <br />SLEEPING ROOM BELOW THE FOURTH STORY IN R OCCUPANCIES, EXCEPT IN R-1/R-2 OF TYPE <br />I, IIA, IIIA, OR IV CONSTRUCTION. ACCESS TO RESCUE OPENINGS SHALL BE IN ACCORDANCE <br />WITH OCFA GUIDELINES B-09 AND E-04. VEGETATION, TOPOGRAPHY, FENCES/WALLS AND <br />OTHER OBSTRUCTIONS SHALL NOT IMPEDE LADDERING OF RESCUE OPENINGS OR THE PATH <br />OF FIREFIGHTER TRAVEL FROM THE FIRE LANE TO SUCH OPENINGS. CBC 1030, CFC 504.1. <br />27.THE SMOKE CONTROL SYSTEM SHALL COMPLY WITH CBC/CFC 909 AND CFC REGULATIONS. <br />REVIEW AND APPROVAL OF A RATIONAL ANALYSIS REPORT IS REQUIRED PRIOR TO <br />COMMENCING CONSTRUCTION. ACCEPTANCE TESTING SHALL BE PERFORMED BY A <br />QUALIFIED THIRD PARTY AND VERIFIED BY AN OCFA INSPECTOR PRIOR TO OCCUPANCY. <br />28.PROJECTS LOCATED WITHIN A D.O.G.G.R. FIELD BOUNDARY, NEAR AN OIL/GAS WELL OR <br />SEEP, OR OTHER LOCATIONS WITH A POTENTIAL FOR COMBUSTIBLE SOIL GAS SHALL <br />UNDERGO EVALUATION AND POSSIBLE MITIGATION AS DESCRIBED IN OCFA GUIDELINE C-03. <br />OCFA ARCHITECTURAL NOTES <br />1 <br />9 <br />90 <br />60 <br />90 <br />20 <br />20 <br />2020 <br />20 <br />20 <br />20 20 <br />90 <br />A0.8 <br />THIRD <br />LEVEL <br />FIRE SEPARATION <br />AND <br />EXITING PLAN <br />SCALE: 1/8" = 1'-0" <br />NO <br />R <br />T <br />H <br />1