Laserfiche WebLink
11 <br />12 9 <br />8 <br />7 1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />THE INTENT OF ARCHITECTURAL DETAILING IS TO REPRESENT THE ARCHITECTURAL ELEMENTS - I.E. <br />WATERPROOFING, FENESTRATION, AND FINISHES, ETC. NON-STRUCTURAL FRAMING ELEMENTS <br />SHOWN IN OUR DETAILS SERVE AS A BASIS FOR CREATING A SHAPE OR FORM AND/OR BACKING. IT <br />IS THE DISCRETION OF THE FRAMER TO CONSTRUCT THE SUB-FRAMING AS THEY FEEL FIT FOR <br />EFFICIENCY. ANY STRUCTURAL ELEMENTS ARE TO BE PER THE STRUCTURAL DRAWINGS AND <br />DETAILS - I.E. FRAMING, ANCHORAGE, AND CONNECTIONS AND SUPPORT, ETC. IF THE <br />ARCHITECTURAL AND STRUCTURAL DETAILS DIFFER, THE STRUCTURAL DRAWINGS AND DETAILS <br />TAKES PRECEDENCE. STRUCTURAL SHEAR PANELS ARE NOT SHOWN AND MAY OCCUR AT ANY <br />CONDITION. <br />IT IS THE RESPONSIBILITY OF THE CLIENT / CONTRACTOR TO NOTIFY THE ARCHITECT IN WRITING, <br />PRIOR TO THE COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF MATERIALS OR PRODUCTS <br />OF ANY DISCOVERY OF ERROR, OMISSION OR CONFLICT WHICH MAY OCCUR IN THE CONSTRUCTION <br />DOCUMENTS. <br />1. <br />THE ARCHITECTURAL DETAILING GRAPHICS ARE SLIGHTLY EXAGGERATED TO HELP DELINEATE <br />TYPICAL FLASHING, BUILDING PAPER, BITUMINOUS PAPER AND WINDOW / DOOR FLASHING, ETC.. <br />2. <br />WALL / ATTIC INSULATION SHOWN ON DETAILS OCCURS ONLY WHERE REQUIRED BY CODE. <br />INSULATION MAY NOT BE SHOWN AT ALL CONDITIONS. PROVIDE INSULATION AS NEEDED PER CODE. <br />4. <br />ALL WOOD TRIM, - WHERE OCCURS - INCLUDING BUT NOT LIMITED TO, FASCIA'S CORBELS, TRELLIS <br />MEMBERS, OPEN DECKS, AND OTHER FINISH WORK, ETC., SHALL BE PRE-PRIMED ON ALL SURFACES, <br />INCLUDING NON-EXPOSED SURFACES, PRIOR TO INSTALLATION. FULLY SEAL AND PRIME ALL CUT <br />ENDS OF WOOD MEMBERS IN CONTACT WITH OTHER WOOD MEMBERS. <br />5. <br />CURRENT DATE: 01/18/18 <br />THE ARCHITECTURAL DETAILS MAY DIFFER SLIGHTLY FROM THE PLANS / EXTERIOR ELEVATIONS, <br />ETC. GRAPHICALLY SINCE THOSE AREAS ARE AT A REDUCED SCALE AND MAY NOT ACCURATELY <br />DEPICT DETAIL CONDITIONS. THE ENLARGED DETAIL TAKES PRECEDENCE. <br />3. <br />SCALE:N.T.S. <br />TYPICAL ARCHITECTURAL DETAIL NOTES <br />00.1.01 <br />32 <br />2 <br /> <br />N <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br /> <br />B <br />L <br />V <br />D <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />SHEET NUMBER <br />2 0 2 4 0 1 0 <br />SHEET TITLE <br />PROJECT NUMBER <br />REVISIONS <br />NO.DATE NO.DATE <br />HANNOUCHE ARCHITECTS <br />EXPRESSLY RESERVES ITS COMMON LAW COPYRIGHT <br />AND OTHER PROPERTY RIGHTS INHERENT IN <br />THESE PLANS. ALL DRAWINGS, ELECTRONIC FILES, <br />FIELD NOTES AND ASSOCIATED DOCUMENTS <br />ARE INSTRUMENTS OF SERVICE AND ARE THE <br />PROPERTY OF HANNOUCHE ARCHITECTS. <br />ALL INFORMATION CONTAINED IN THESE DRAWINGS, <br />ELECTRONIC FILES, FIELD NOTES AND ASSOCIATED <br />DOCUMENTS IS PROJECT SPECIFIC AND SHALL NOT <br />BE REPRODUCED, DISCLOSED, CHANGED, COPIED, <br />OR USED OTHERWISE IN ANY FORM OR MANNER <br />WHATSOEVER, WITHOUT FIRST OBTAINING THE <br />EXPRESSED WRITTEN PERMISSION AND CONSENT <br />OF HANNOUCHE ARCHITECTS. <br />HANNOUCHE ARCHITECT c 2021 <br />HANNOUCHE <br />ARCHITECTS <br />949.261.2070 <br />SAMIR HANNOUCHE, ARCHITECT <br />20250 SW ACACIA ST. #145 NEWPORT BEACH, CA 92660 <br />May 9, 2025 <br />1 CORR <br />12/10/24 <br />BLDG <br />A CORR <br />3/18/25 <br />OCFA <br />2 CORR <br />4/09/25 <br />BLDG <br />DATE SIGNED2 <br />3 CORR <br />5/09/25 <br />BLDG <br />KEE HATCH <br />MODEL # RHSR-0 4848 <br />3' <br />- <br />6 <br />" <br />COVER <br />AUTOMATIC HOLD-OPEN AND <br />OPERATING ARM <br />OR APPROVED EQUAL. <br />SCALE:1" = 1'-0" <br />ROOF ACCESS HATCH <br />RF HATCH 01 <br />48" X 48" OPENING <br />OPEN CELL SPRAYFOAM <br />UNDER PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />INSULATION AS PER TITLE 24 <br />REQUIREMENTS <br />SCALE:3" = 1'-0" <br />ROOF SMOKE HATCH FLASHING <br />05.9.03 <br />ROOF HATCH ASSEMBLY <br />UNIT COUNTERFLASHING <br />BASE FLASHING FASTENERS @ 6" O.C. <br />3/8" HEAD SCREW THROUGH 5/8" <br />STEEL/NEOPRENE WASHER MIN. 3 EA PER <br />SIDE <br />METAL COUNTERFLASHING INSERT <br />4" FIBER CANT STRIP <br />BUILT-UP ROOFING <br />3/4" PLYWOOD BY FRAMER <br />BITUTHENE MEMBRANE AT PENETRATION <br />OPEN CELL SPRAYFOAM <br />UNDER PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />SCALE:1 1/2" = 1'-0"RF022 <br />MECH. PLATFORM <br />MECHANICAL UNIT - SEE <br />MECHANICAL DRAWINGS <br />SINGLE-PLY ROOFING SYSTEM OVER <br />3/4" PLYWOOD DECK - SLOPE 1/4" <br />PER FOOT <br />DBL. TREATED 2 x 8s AT 12" O.C. CUT <br />TO ALLOW FOR 1/4"/FT. SLOPE <br />SEE ROOF PLAN <br />ROOF FRAMING PER STRUCT. <br />ATTACH MECHANICAL UNIT SUPPORTS TO <br />PLATFORM IN ACCORDANCE WITH ROOFING <br />MANUFACTURE'S REQUIREMENTS. PROVIDE <br />ISOLATORS <br />CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. INSTALLED <br />PER MANUF. <br />CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. INSTALLED <br />PER MANUF. <br />INSULATION AS PER TITLE 24 <br />REQUIREMENTS <br />D1.2 <br />ARCHITECTURAL <br />ROOF DECK <br />DETAILS <br />VARIES <br />SCALE:3" = 1'-0" <br />DECK SCUPPER <br />04.5.01 <br />SEE <br />ELEV <br />8" <br />4" <br />4" <br />FIELD <br /> <br />V <br />E <br />R <br />I <br />F <br />Y <br />SCUPPER ISOMETRIC <br />TO UNDERLYING SUBSTRATE <br />AND TO WALL USING APPROPRIATE <br />FASTENERS @4" O.C. STAGGERED <br />WALL <br />STRUCTURE <br />24 GA. SCUPPER - FASTEN <br />BUILT-UP WATERPROOF DECKING PER SPECS. <br />SCALE:3" = 1'-0" <br />DECK SCUPPER OVERFLOW <br />04.5.02 <br />FINISH PER DETAILS. <br />2" <br /> <br />M <br />I <br />N <br />4" <br />1" MIN. <br />DECK SHEATHING PER <br />STRUCTURAL DRAWINGS <br />DECK FRAMING AS OCCURS <br />NOTE: SCUPPER DETAIL IS FOR <br />CONCEPT ONLY: SCUPPER MUST <br />BE SHOP PREFAB. IN 2 PIECES & <br />ASSEMBLED IN THE FIELD. <br />SUBMIT SHOP DWGS OF <br />PROPOSED FABRICATION FOR <br />REVIEW BY ARCHITECT. <br />NOTE: PAPER & CAULK <br />AROUND ALL NAILING <br />FLANGES TO MATCH DET. <br />CLOSE CELL SPRAYFOAM <br />OVER PLYWOOD <br />SHEATHING. INSTALLED <br />PER MANUF. <br />2X RIPPING SLOPED PER <br />PLAN MIN. HEIGHT 1 1/2" <br />CANT STRIP <br />G.I. OVERFLOW SCUPPER <br />W/ NAILING FLANGESSEALANT ALL SIDE OF <br />SCUPPER <br />SELF ADHERE <br />WATERPROOFING MEMBRANE <br />WRAPPED OVER THE WALL 6" <br />MIN. <br />SCALE:3" = 1'-0" <br />DECK SCUPPER WITH DOWNSPOUT <br />04.5.02_2 <br />FINISH PER DETAILS. <br />4" <br />1" MIN. <br />NOTE: PAPER & CAULK <br />AROUND ALL NAILING <br />FLANGES TO MATCH DET. <br />LEADER HEAD WITH <br />DOWNSPOUT <br />DECK SHEATHING PER <br />STRUCTURAL DRAWINGS <br />DECK FRAMING AS OCCURS <br />2X RIPPING SLOPED PER <br />PLAN MIN. HEIGHT 1 1/2" <br />CLOSE CELL SPRAYFOAM OVER <br />PLYWOOD SHEATHING. <br />INSTALLED PER MANUF. <br />G.I. SCUPPER W/ NAILING <br />FLANGES <br />SEALANT ALL SIDE OF <br />SCUPPER <br />SELF ADHERE <br />WATERPROOFING MEMBRANE <br />WRAPPED OVER THE WALL 6" <br />MIN.