SPECIAL INSPECTIONS <br />VERIFICATION <br />& INSPECTION <br />1. Welding procedure specifications <br /> (WPSs) available. <br />4. Welder identification system. <br />a. Joint preparation. <br />6. Configuration and finish of <br /> access holes. <br />SPECIAL INSPECTION TABLE FOR <br />STEEL STRUCTURES <br />FOR THE CONSTRUCTION OF STEEL ELEMENTS OF BUILDING & STRUCTURES, ITEMS <br /> OF SPECIAL INSPECTION & VERIFICATIONS BY A SPECIAL INSPECTOR <br /> ARE REQUIRED & SUMMARIZED IN THE FOLLING TABLE: <br />Quality Assurance Reference <br />Standard <br />b. Dimensions (alignment, root <br /> opening, root face, bevel). <br />a. Dimensions (alignment, gaps <br /> at root). <br />c. Cleanliness (condition of steel <br /> surfaces).AISC 360-10 <br />TABLE N5.4-1 <br />2. Manufacture certifications for <br /> welding consumables available. <br />3. Material identification ( type / <br />grade). <br />5. Fit-up groove welds ( including <br /> joint geometry). <br />d. Tacking (tack weld quality and <br /> location). <br />e. Backing type and fit (if <br /> applicable). <br />7. Fit-up of fillet welds. <br />b. Cleanliness (condition of steel <br /> surfaces). <br />8. Check welding equipment. <br />Performed Observed <br />- <br />1. Use of qualified welders. <br />4. Environmental conditions. <br />a. Wind speed within limits. <br />b. Precipitation and temperature. <br />g. Proper position (F, V, H, OH ). <br />a. Settings on welding equipment. <br />AISC 360-10 <br />TABLE N5.4-2 <br />2. Control and handling of welding <br />consumables. <br />3. No welding over cracked <br /> tack welds. <br />b. Travel speed. <br />c. Selected welding materials. <br />6. Welding techniques. <br />5. WPS followed: <br />d. Shielding gas type/ flow rate. <br />e. Preheat applied. <br />f. Interpass temperature <br />maintained (min./ max.). <br />a. Interpass and final cleaning. <br />b. Each pass within profile <br /> limitations. <br />c. Each pass meets quality <br /> requirements. <br />1. Welds cleaned. <br />b. Weld/ base-metal fusion. <br />c. Crater cross section. <br />e. Weld size.AISC 360-10 <br />TABLE N5.4-3 <br />2. Size, length and location of <br /> welds. <br />3. Welds meet visual acceptance <br /> criteria. <br />f. Undercut. <br />g. Porosity. <br />8. Document acceptance or <br />rejection of welded joint or <br />member. <br />a. Crack prohibition. <br />d. Weld profiles. <br />4. Arc strikes. <br />5. K-area. <br />6. Backing removed and weld tabs <br /> removed (if required). <br />7. Repair activities. <br />TASKS PRIOR TO WELDING <br />TASKS DURING WELDING <br />TASKS AFTER WELDING <br />c. Tacking (tack weld quality <br /> and location). <br />a. Packaging. <br />b. Exposure control. <br />VERIFICATION <br />& INSPECTION <br />1. Manufacturer's certifications <br />available for fastener materials. <br />SPECIAL INSPECTION TABLE FOR <br />STEEL STRUCTURES <br />Quality Assurance Reference <br />Standard <br />AISC 360-10 <br />TABLE N5.6-1 <br />2. Fasteners marked in accordance <br />with ASTM requirements. <br />3. Proper fasteners selected for the <br />joint detail (grade, type, bolt <br />length if threads are to be <br />excluded from shear plane). <br />4. Proper bolting procedure <br />selected for joint detail. <br />7. Proper storage provided for <br />bolts, nuts, washers and other <br />fastener components. <br />Performed Observed <br />5. Connecting elements, including <br />the appropriate faying surface <br />condition and hole preparation, <br />if specified, meet applicable <br />requirements. <br />6. Pre-installation verification <br />testing by installation personnel <br />observed and documented for <br />fastener assemblies and <br />methods used. <br />1. Fastener assemblies, of suitable <br />condition, placed in all holes and <br />washers (if required) are <br />positioned as required. <br />AISC 360-10 <br />TABLE N5.6-2 <br />2. Joint brought to the snug-tight <br />condition prior to the <br />pretensioning operation. <br />3. Fastener component not turned <br />by the wrench prevented from <br />rotating. <br />4. Fasteners are pretensioned in <br />accordance with the RCSC <br />Specification, progressing <br />systematically from the most <br />rigid point toward the free <br />edges. <br />TASKS PRIOR TO BOLTING <br />TASKS DURING BOLTING <br />1. Document acceptance or <br /> rejection of bolted connections. <br />AISC 360-10 <br />TABLE N5.6-3 <br />TASKS AFTER BOLTING <br />SPECIAL INSPECTION: <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />1. <br />Site visits by the structural engineer do not constitute an inspection. <br />VERIFICATION & INSPECTION TASK <br />12. <br />INSPECTION <br />TASK Continuous Periodically SECTION <br />Sec. 1705.11.2 <br />Sec. 1705.11.2 <br />Sec. 1704 <br />Sec. 1705.11.2 <br />Sec. 1705.11.3 <br />* Contact Gouvis Engineering to schedule A Special Inspection. <br />In addition to the regular inspection the following items will also require special inspection in <br />accordance with Sec.1704, unless exempted by the exceptions of Sec.1704.2, of the Building Code <br />Soils compliance prior to the foundation inspection, post-tensioned foundation, high strength steel and <br />concrete. <br />All inspections and tests shall be performed by a qualified testing agency retained by the owner. <br />The special inspector shall be qualified and approved by the building department and acceptable to <br />the architect. <br />The special inspector shall observe work assigned for conformance to the approved design drawings <br />and specifications. <br />The special inspector shall furnish an inspection report to the building department, engineer and <br />architect of record. Copies of the report shall be available at the job site at all times. <br />Final reports for all inspections and testing must be provided by the special inspector. Final reports <br />shall document completion of all inspections and correction of all noted discrepencies. <br />The duties of the special inspector shall be in conformance with the requirements of section 1704 of <br />the latest edition of the CBC. <br />Contractor shall be responsible for all expenses due to any premature notification of inspection which <br />results in additional site visits. <br />Failure of notification by the contractor for inspection on a timely basis may result in complete removal <br />and replacement of all work performed at contractors expense. <br />For special inspection of wood diaphragm and shear walls, contact Gouvis Engineering for schedule. <br />Special inspection is required for the following items: <br />1. Verify materials below footings are <br />adequate to achieve the design <br />bearing capacity per soils report. <br />2. Verify excavations are extended to <br />proper depth & have reached <br />proper material per soils report. <br />3. Perform classification & testing of <br />controlled fill materials per soils <br />report. <br />4. Verify use of proper materials, <br />densities & lift thicknesses during <br />placement & compaction of <br />controlled fill per soils report. <br />5. Prior to placement of controlled fill, <br />observe subgrade & verify that site <br />has been prepared properly per <br />soils report. <br />Exception: <br />_ Special inspection is not required <br />during placement of controlled fill <br />having a total depth of 12 inches or <br />less. <br />Horizontal wood <br />diaphragms with <br />edge nail spacing <br />equal to or closer <br />than 4" o.c. <br />Wood shear walls <br />with edge nail <br />spacing equal to or <br />closer than 4" o.c. <br />Sheathing types, <br />grade thickness, <br />span rating, and nail <br />types, nail sizes & <br />spacing. <br />Sheathing types, <br />grade thickness, wall <br />nail types, nailing <br />sizes and spacing. <br />Sill nail types, size <br />and spacing. <br />Anchor bolt sizes & <br />spacing. <br />Holdown types & <br />their connections to <br />shear walls & <br />foundation/framing <br />Wall end post sizes. <br />Shear transfer <br />connector types & <br />spacing. Drag strut <br />connections to shear <br />walls. <br />Panel types, nailing, <br />bolting, Anchoring, <br />wall top plate screw <br />types, sizes & <br />spacing, holddown & <br />drag strut <br />connections to <br />walls/panels. <br />Manufactured shear <br />walls, Hardy panels, <br />Simpson steel & <br />Wood Strong walls. <br />SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR EXISTING SITE SOIL CONDITIONS, <br />FILL PLACEMENT & LOAD BEARING REQUIREMENTS SHALL BE PERFORMED PER THE <br />FOLLOWING TABLE. <br />SPECIAL INSPECTION TABLE FOR EXISTING SITE <br />SOIL CONDITIONS <br />SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR THE CONSTRUCTION OF <br />HORIZONTAL WOOD DIAPHRAGMS, WOOD SHEAR WALLS & MANUFACTURED SHEAR <br />WALLS ARE REQUIRED & SPECIFIED IN THE FOLLOWING TABLE: <br />SPECIAL INSPECTION TABLE FOR WOOD * <br />DIAPHRAGM & SHEAR WALLS <br />Periodically <br />during task <br />Not <br />Applicable <br />Continuous <br />during task <br />REFERENCE <br />FOR CRITERIA <br />FREQUENCY OF <br />INSPECTIONNOT <br />APPLICABLE <br />Exception: Special inspection for existing site soil condtions per table below is not required if <br />allowable soil bearing pressure used for design is ≤ 1500 psf, soils report is not required <br />by building offical, and there is no controlled fill placement on existing building site <br />CBC/IBC <br />INSPECTION TASK <br />FREQUENCY OF INSPECTION REFERENCE FOR CRITERIA <br />IBC <br />Section <br />ACI <br />530/ASCE <br />5/TMS 402 <br />ACI <br />530.1/ASCE <br />6/TMS 602 <br />a. Grout space. <br />Sec. <br />1.16 <br />Art. <br />2.4B, <br />Art. <br />3.4, <br />Art. <br />3.6B <br />Art. <br />3.2D, <br />Art. <br />2.4, <br />Art. <br />3.2E,3.4, <br />Art. <br />2.6B, <br />For SI: °C = (°F-32) /1.8 <br />VERIFICATION & <br />INSPECTION TASK <br />3.5, 7.1-7.7 <br />AWS D1.4 <br />ACI 318: 3.5.2 <br />c. Shear reinforcement <br />d. Other reinforcing steel <br />ACI 318: <br />2. As masonry construction <br />begins,the following shall be <br />verified to ensure compliance: <br />a. Proportions of site prepared <br />mortar. <br />b. Construction of mortar joints. <br />c. Grade and size of prestressing <br />tendons and anchorages. <br />3. Prior to grouting, verify that <br />the following are in <br />compliance: <br />b. Grade, type, and size of <br />reinforcement and anchor <br />bolts, and prestressing <br />tendons and anchorages. <br />c. Placement of reinforcement, <br />connectors, and prestressing <br />tendons and anchorages. <br />d. Proportions of site-prepared <br />grout and prestressing grout for <br />bonded tendons. <br />1. Inspection of reinforcing steel <br />and placement. <br />a. Placing of reinforcing steel <br />b. Sampling and testing of steel <br />(mill reports & identification of <br />steel) <br />c. Inspection of installation of <br />rebar couplers <br />d. Reinforcing steel sizes, <br />spacing, splices, clearance <br />and concrete cover per <br />construction documents <br />2. Inspection of reinforcing steel <br />welding in the following items: <br />a. Verification of weldability of <br />reinforcing steel other than <br />ASTM A706 <br />b. Reinforcing steel-resisting <br />flexural and axial forces in <br />intermediate and special <br />moment frames, and <br />boundary elements of special <br />reinforced concrete shearwalls <br />and shear reinforcement <br />EXCEPTION: CONCRETE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME WOOD <br />BUILDING OF 3-STORIES OR LESS AND THE STRUCTURAL DESIGN OF FOOTINGS IS <br />BASED ON A SPECIFIED COMPRESSIVE STRENGTH f'c NO GREATER THAN 2500 psi. <br />SPECIAL INSPECTION TABLE FOR <br />CONCRETE CONSTRUCTION <br />SPECIAL INSPECTIONS AND VERIFICATIONS BY A SPECIAL INSPECTOR ARE REQUIRED <br />FOR CONCRETE CONSTRUCTION AND SPECIFIED IN THE FOLLOWING TABLE SPECIAL INSPECTION BY A SPECIAL INSPECTOR FOR THE CONSTRUCTION OF CMU <br />STRUCTURES ARE REQUIRED AND SPECIFIED IN THE FOLLOWING TABLE: <br />SPECIAL INSPECTION TABLE FOR <br />CMU STRUCTURES <br />Periodically <br />during task <br />listed <br />Not <br />Applicable <br />Continuous <br />during task <br />listed <br />Reference <br />Standard <br />IBC <br />Reference <br />Periodically <br />during task <br />listed <br />Not <br />Applicable <br />Continuous <br />during task <br />listed <br />1910.4 <br />ACI 318: <br />Ch. 4, 5.2-5.4 <br />1904.2, <br />a. Method of proportioning <br />b. W/C ratio <br />c. Cement type <br />d. Strength <br />ASTM C 172 <br />ASTM C 31 <br />ACI 318: 5.6, 5.8 <br />ACI 318: 5.9, 5.10 <br />ACI 318: <br />ACI 318: 18.20 <br />ACI 318: 18.18.4 <br />ACI 318: 6.2 <br />ACI 318: 6.1.1 <br />Item 1 <br />Item 5 <br />Item 6 <br />Item 7 <br />Item 8 <br />1910.4 <br />1910.2 <br />1910.10 <br />1910.6 <br />1910.9 <br />1910.8 <br />a. Placing of P.T tendons <br />5. Verifying use of required <br />design mix <br />6. At the time fresh concrete is <br />sampled to fabricate specimens <br />for strength tests, perform <br />slump and air content tests, <br />Determine the temperature of <br />the concrete for shotcrete <br />construction <br />7. Inspection of concrete for <br />proper application techniques. <br />(conveying & depositing) <br />8. Inspection for maintenance of <br />specified curing temperature <br />(cold weather & hot weather) <br />and techniques <br />b. During stressing of P.T. <br />tendons <br />c. Grouting of P.T. tendons in the <br />seismic-force-resisting <br />system. (including concrete <br />slab) <br />d. Field measured elongation and <br />jacking force records <br />e. P.T. tendon protective <br />wrapping <br />f. Claibration of P.T. RAM (report) <br />10. Verification of in-situ concrete <br />strength, prior to stressing of <br />tendons in post-tensioned <br />concrete and prior to removal <br />of shores and forms from <br />beams and structural slabs <br />11. Inspect formwork for shape, <br />location and dimensions of <br />the concrete member being <br />formed <br />12. Inspection of shorcrete shall <br />include item 1,5,6,7,8 <br />indicated in this table <br />1910.3 <br />1910.7 <br />5.11-5.13 <br />9. Inspection of P.T. tendons <br />4. Inspection of anchors <br /> post- installed in hardened <br /> concrete members. <br />3. Inspection of anchors cast in <br />concrete where allowable loads <br />have been increased or where <br />strength design is used.8.1.3, 21.1.8 <br />ACI 318: <br />1909.13.8.6, 8.1.3, <br />ACI 318: <br />Art. <br />1. Verify compliance with the <br />approved submittals and <br />required inspection provisions <br />for (Mortar mix design, Grout <br />mix design, Material certificates <br />for mortar, grout, masonry units, <br /> reinforcement, anchors, ties, <br /> and fasteners). <br />Art. <br />1.5 <br />Art. <br />2.1, 2.6A <br />11. <br />1908.5, <br />1909.1, <br />1910.2, <br />1910.3 <br />1910.9 <br />d. Location of reinforcement, <br />connectors, and prestressing <br />tendons and anchorages. <br />e. Prestressing technique. <br />f. Properties of thin-bed mortar <br />for AAC masonry. <br />Sec. <br />1.16.4.3, <br />1.17.1 <br />Sec. <br />2.1.7.7.2, <br />3.3.3.4(c), <br />4. Verify during construction. <br />a. Size and location of structural <br />elements <br />b. Type, size and location of <br />anchors, including other <br />details of anchorage of <br />masonry to structural <br />members, frames or other <br />construction. <br />c. Welding of reinforcement. <br />d. Preparation, construction, and <br />protection of masonry during cold <br />weather (temp. below 40°) or hot <br />weather (temp. above 90°). <br />e. Application and measurement <br />of presstressing force <br />e. Construction of mortar joints. <br />f. Placement of grout and <br />prestressing grout for bonded <br />tendons is in compliance. <br />g. Observe preparation of grout <br />specimens, mortar specimens, <br />and/or prisms. <br />6. Verification of f'm prior to <br />construction. <br />7. Verification of slump flow and <br /> VSI as delivered to the <br /> self-consolidating grout. <br />Art. <br />1.4B.2.a.3 <br />Art. <br />5. Observe preparation of grout <br />specimens, mortar <br />specimens, and/or prisms. <br />Art. <br />3.3B <br />2.4H, <br />3.6A <br />Art. <br />2.1C <br />3.2F <br />3.4 <br />Sec. <br />1.16 3.6A <br />2.4G.1.b <br />Art. 3.3B <br />Art. 3.3F <br />8.3.3.4(b) <br />Art. <br />1.8C, <br />1.8D <br />3.6B <br />Art. <br />3.5, <br />3.6C <br />Art. <br />3.3B.8 <br />1.4B.2.b.3 <br />1.4B.2.c.3 <br />1.4B.3, <br />1.4B.4 <br />1.4B <br />Art. <br />1.5B.1.b.3 <br />21.1.8 <br />VERIFICATION <br />& INSPECTION <br />Applicable ASTM <br />material standards <br />1. Material verification of <br /> cold-formed steel deck: <br />a. Identification markings to <br /> conform to ASTM standards <br /> specified in the approved <br /> construction documents. <br />b. Manufacturer's certified <br /> test reports. <br />2. Inspection of welding: <br />a. Cold-formed steel deck: <br />SPECIAL INSPECTION TABLE FOR STEEL <br />CONSTRUCTION OTHER THAN STRUCTURAL STEEL <br />FOR THE CONSTRUCTION OF OTHER STEEL ELEMENTS OF BUILDING & STRUCTURES, ITEMS <br />OF SPECIAL INSPECTION & VERIFICATIONS BY A SPECIAL INSPECTOR ARE REQUIRED & <br />SUMMARIZED IN THE FOLLOWING TABLE: <br />Periodically <br />during task <br />listed <br />Not <br />Applicable <br />Continuous <br />during task <br />listed <br />Reference <br />Standard <br />b. Reinforcing steel: <br />ACI 318: <br />Section 3.5.2 <br />1) Floor and roof deck welds. <br />1) Verification of weldability of <br /> reinforcing steel other than <br /> ASTM A 706. <br />2) Reinforcing steel resisting <br /> flexural and axial forces in <br /> intermediate and special <br /> moment frames, and <br /> boundary elements of <br /> special structural walls of <br /> concrete and shear <br /> reinforcement. <br />3) Shear reinforcement. <br />4) Other reinforcing steel. <br />AWS D1.3 <br />AWS D1.4 <br />RESTRICTIVE NOTICE <br />DATE REVISIONS <br />SHEET DESCRIPTION <br />PROJECT OWNER <br />PROJECT ADDRESS <br />STAMP <br />NO: <br />REVISIONS <br />DATE SIGNED: 4/8/25 <br />THESE DESIGNS, DRAWINGS, AND <br />SPECIFICATIONS ARE THE EXCLUSIVE <br />PROPERTY OF DONG ENGINEERING. <br />THESE DRAWINGS CANNOT BE COPIED, <br />TRANSFERRED, OR REPRODUCED NOR <br />CAN ANY OTHER STRUCTURES BE BUILT <br />FROM THEM WITHOUT WRITTEN CONSENT. <br />SHEET <br />DE#: <br />TEL- 714-617-5979 <br />GARDEN GROVE, CA 92841 <br />7661 GARDEN GROVE BLVD., <br />DONG ENGINEERING, INC. <br />INFO@DONGENGINEERING.COM <br />240022 <br />22 <br /> <br />U <br />N <br />I <br />T <br />S <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />32 <br />2 <br /> <br />N <br />. <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br />B <br />L <br />V <br />D <br />, <br /> S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />30 <br />, <br />5 <br />8 <br />2 <br /> <br />S <br />F <br /> <br />G <br />R <br />O <br />S <br />S <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />A <br />R <br />E <br />A <br />S0.2 <br />SPECIAL INSPECTION