My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
DEF 1-1851 E Fourth St Bldg P - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
1851 E Fourth St Bldg# P
>
DEF 1-1851 E Fourth St Bldg P - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 5:00:13 AM
Creation date
2/25/2026 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
101126384
Full Address
1851 E Fourth St Bldg# P
Street Number
1851
Street Direction
E
Street Name
Fourth
Street Suffix
St
Building Number
P
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
(if-r tl-hll — f f14GF�S <br />www.hiki.us <br />Company: Jaik Choi & Associates Page: ^' <br />Specifier: Jaik Choi Project: <br />Address: 1215 Portside Way, Corona Del Mar, CA 92625 Sub -Project I Pos. No.: <br />Phone I Fax: (949)706-7769 1 (424)239-2666 <br />E-Mail: jgse@msn.com <br />Specifier's comments: Impact load=6,000 #, phi =.75 <br />1 Input data <br />CITY OF SANTA ANA <br />Planning and Builcling 2,ency <br />Approved- <br />IsPA`rlcko',[T117S UANCE <br />CD -LA Co Ancil-58S <br />M"a fT.wedge) <br />Date: <br />1'er ..ININ�).Jiilvh <br />Anchor type and diameter: Kwik Solt T2 - CS 518 (4) <br />Effective embedment depth: h.,.;,, = 4.000 in., hnan = 4,438 in, ` <br />Material: Carbon Steel <br />Evrluation Service Report: ESR-1917 !Sw � "I E.. <br />Issued I Valid: 6/1/2016 1 5/1/2017 <br />Proof: Design method ACI 318-14 / Mech. <br />Stand-off installation: eb = 0.000 in. (no standoff); t = 0.375 in. <br />Anchor plate: 1, x ly x t = 42.000 in, x 6.000 in. x 0.375 in.; (Recommended plate thickness: not calculated <br />Profile; Rectangular HSS (AISC); (L x W x T) = 3.000 in, x 2.000 in. x 0.250 in, <br />Base material: uncracked concrete, 4000, fn` = 4000 psi; h = 12.000 In. <br />Installation: hammer drilled hole, Installation condition: Dry <br />Reinforcement: tenyfon: condition B, shear: condition B; no supplemental splitting reinforcement present <br />edge reinforcement: none or < No. 4 bar <br />Geometry [in.] & Loading [lb, in.lb) <br />zi <br />1- <br />x <br />Input data and rusuhs must be checked for agreement with the ormting conditions and for plausibilityl <br />PROFIS Anchor (c) 2003-2009 HIM AG, FL-9494 Schuan HIM Is a raglatered Trademark of HIM AG. Schaan <br />
The URL can be used to link to this page
Your browser does not support the video tag.