Laserfiche WebLink
PAGE <br />REV: D 1/13/2026 <br />JULIE VO <br />3455 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-455VO PR-3004660114 <br />SHEET <br />DESIGNER: <br />SREERAJ P R <br />CUSTOMER RESIDENCE: <br />TEL. (309) 660-0844 <br />APN: 412-531-51 <br />(415) 580-6920 ex3 <br />PV-5.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SIGNAGE <br />ENERGY STORAGE SYSTEM <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C), NEC 2020: 706.15(C) <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 705.12(B)(3)(2), <br />CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR <br />IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />4" <br />3" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): NEC 2020: 690.13(B), CEC <br />2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): NEC 2020: 690.53, CEC 2022: 690.53 <br />WARNING: PHOTOVOLTAICPOWER SOURCEWARNING: PHOTOVOLTAICPOWER SOURCE <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): NEC 2020: 690.31(D)(2), CEC 2022: <br />690.31(D)(2) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN <br />SWITCH PER CODE(S): NEC 2020: 690.56(C)(2), <br />CEC 2022: 690.56(C)(2), IFC 2018: 1204.5.3 <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): NEC 2020: 705.12(C), CEC <br />2022: 705.12(C) <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): CEC 2022: 706.15(C) <br />120/240 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />REQUIREMENT: UL 1741, SECTION 206.3 <br />LOCATION: AROUND THE CT WIRE BY CLAMP <br />SIZE 4.25" X 0.75" <br />INVERTER 1&2 <br />LABEL LOCATION: <br />REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 <br />LOCATION: MAIN PANEL <br />SIZE: 4.25" X 1.25" <br />PCS CONTROLLED CURRENT SETTING: 180 A <br />THE MAXIMUM OUTPUT CURRENT FROM THIS <br />SYSTEM IS CONTROLLED ELECTRONICALLY. <br />REFER TO THE MANUFACTURER'S <br />INSTRUCTIONS FOR MORE INFORMATION.