DESIGN CRITERIA <br />MAX DISTRIBUTED LOAD: 3 PSF <br />SNOW LOAD: 0 PSF <br />WIND SPEED: <br />96 MPH 3-SEC GUST.FASTENERS: <br />(1) 5/16" DIA S.S. LAG SCREW: 2.5" <br />MIN EMBEDMENT INTO FRAMING <br />PAGE <br />REV: B 12/23/2025 <br />JULIE VO <br />3455 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-455VO PR-3004660114 <br />SHEET <br />DESIGNER: <br />SREERAJ P R <br />CUSTOMER RESIDENCE: <br />TEL. (309) 660-0844 <br />APN: 412-531-51 <br />(415) 580-6920 ex3 <br />PV-3.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />LAYOUT <br />SOLAR MODULE <br />SNAPNRACK <br />RACKING <br />MODULE ELEVATION DETAIL - SCALE: NTS <br />4.5" <br />ROOF INFO ATTACHMENT INFORMATION <br />Name Type Height Detail Max Landscape <br />OC Spacing <br />Max Landscape <br />Overhang <br />Max Portrait <br />OC Spacing <br />Max Portrait <br />Overhang Configuration <br />AR-01 COMP SHINGLE - UR - ULTRAFOOT 2-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0"2'-4"6'-0" 2'-3"STAGGERED <br />AR-02 COMP SHINGLE - UR - ULTRAFOOT 2-Story ULTRAFOOT RAIL TO FRAMING SNR-DC-01507 6'-0" 2'-4" 6'-0" 2'-3" STAGGERED <br />D1 - AR-01 - SCALE: 1/8" = 1'-0" <br />AZIM: 269° <br />PITCH:30° <br />D2 - AR-02 - SCALE: 1/8" = 1'-0" <br />AZIM: 89° <br />PITCH:30° <br />41'-8" <br />22'-9" <br />2'-5"3'-1" <br />2'-1" <br />1'-1" <br />18'-10"13'-5"11'-3" <br />12'-1" <br />1'3'-1" <br />1'-11" <br />11' <br />(E)CHIMNEY <br />ATTACHMENTS FOR THIS INSTALLATION ARE DESIGNED FOR A STANDARD <br />WOOD FRAMED ROOF STRUCTURE FREE FROM DAMAGE, <br />DETERIORATION, OR MODIFICATION THAT WOULD COMPROMISE ITS <br />ORIGINAL DESIGN INTEGRITY. INSTALLERS SHALL OBSERVE THE <br />FRAMING FOR CONFORMANCE TO THE BELOW REQUIREMENTS AND <br />NOTIFY THE ENGINEER OF ANY POTENTIAL STRUCTURAL ISSUES FOR <br />GUIDANCE PRIOR TO PROCEEDING WITH INSTALLATION. <br />i: MINIMUM 2x WOOD FRAMING (NOMINAL) FREE FROM DAMAGE, <br />DETERIORATION, OR MODIFICATION <br />ii: FRAMING SPACING AT 24" O.C. MAX <br />iii: FASTENER SHALL BE EMBEDED INTO COMPETENT MATERIAL <br />INSTALLERS SHALL NOTIFY ENGINEER OF ANY POTENTIAL STRUCTURAL <br />ISSUES OBSERVED PRIOR TO PROCEEDING W/ INSTALLATION. <br />· IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12" (48" FOR TILT KITS) <br />BOUNDARY REGION OF ANY ROOF PLANE EDGES (EXCEPT VALLEYS), <br />THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG REDUCED <br />WITHIN THE 12" (48" FOR TILT KITS) BOUNDARY REGION ONLY AS <br />FOLLOWS: ·· ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO <br />BE REDUCED BY 50%. ·· ALLOWABLE OVERHANG INDICATED ON PLANS TO <br />BE 1/5TH OF ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS. <br />Signed: 12/26/2025