3455 S Crawford Glen - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Crawford Glen
>
3455 S Crawford Glen
>
3455 S Crawford Glen - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 5:00:14 AM
Creation date
2/25/2026 5:00:08 AM
Metadata
Fields
Template:
Plan
Permit Number
20187698
101126163
Full Address
3455 S Crawford Glen
Street Number
3455
Street Direction
S
Street Name
Crawford Glen
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CONDUIT SCHEDULE <br />TAG CIRCUIT DESCRIPTION CONDUCTOR NEUTRAL GROUND CONDUIT <br />1 Inverter Input (2) 10 AWG (PV WIRE)N/A 6 AWG (BARE)Open Air <br />2 Inverter Input (4) 10 AWG <br />THHN/THWN-2 N/A 8 AWG THHN/THWN-2 3/4 EMT <br />3 Inverter Output (2) 6 AWG <br />THHN/THWN-2 <br />(1) 6 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 3/4 EMT <br />4 Gateway Output (2) 1/0 AWG <br />THHN/THWN-2 <br />(1) 1/0 AWG <br />THHN/THWN-2 6 AWG THHN/THWN-2 1-1/2 EMT <br />5 BACKUP LOADS <br />(18) 12 AWG <br />THHN/THWN-2 <br />(18) 12 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />2 EMT(4) 10 AWG <br />THHN/THWN-2 <br />(2) 10 AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />(4) 8AWG <br />THHN/THWN-2 <br />(2) 8AWG <br />THHN/THWN-2 8 AWG THHN/THWN-2 <br />PAGE <br />REV: D 1/13/2026 <br />JULIE VO <br />3455 S CRAWFORD GLEN, <br />SANTA ANA, CA, 92704 <br />PROJECT NUMBER: <br /> 109R-455VO PR-3004660114 <br />SHEET <br />DESIGNER: <br />SREERAJ P R <br />CUSTOMER RESIDENCE: <br />TEL. (309) 660-0844 <br />APN: 412-531-51 <br />(415) 580-6920 ex3 <br />PV-4.1 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />ELECTRICAL CONT. <br />INSTALLER MUST CHECK THE CONDITION, <br />INSTALLABILITY AND CODE COMPLIANCE OF <br />EXISTING EQUIPMENT. <br />General Notes: <br />• CITY REQUIRES TWO SOURCES OF GROUND - UFER, TWO GROUNDS RODS OR <br />COLD WATER GAS BOND <br />• INSTALL THE BACKED UP LOAD CONDUCTORS AND THE MICROGRID <br />INTERCONNECTION DEVICE BREAKER CONDUCTORS IN TWO SEPARATE <br />CONDUITS. <br /> ANY MULTIWIRE BRANCH CIRCUITS <br />RELOCATED ARE TO BE IDENTIFIED, GROUPED, <br />AND EQUIPPED WITH A 2-POLE OCPD BREAKER <br />PER CEC 210.4(B,D). <br />IF THE RELOCATED LOADS EXTEND MORE <br />THAN 6 FEET, AFCI PROTECTION APPLIES PER <br />CEC 210.12 <br />POWER CONTROL SYSTEM (PCS): <br />A PCS IS INSTALLED IN ACCORDANCE WITH CEC 2022 705.13 <br />THE PCS SHALL LIMIT GENERATION SOURCE OUTPUT SUCH THAT CURRENT FROM ALL SOURCES OF SUPPLY DOES NOT EXCEED THE <br />RATING OF ANY BUSBAR OR CONDUCTOR SUPPLIED BY THE POWER PRODUCTION SOURCES <br /> • ANY BUSBAR OR CONDUCTOR ON THE LOAD SIDE OF THE SERVICE DISCONNECT NOT MONITORED BY THE PCS SHALL COMPLY WITH <br />ARTICLE 705.12. <br />ACCESS TO PCS CONTROLS IS RESTRICTED TO QUALIFIED PERSONS IN ACCORDANCE WITH 240.6(C). <br />ENERGY STORAGE SYSTEM: (2) TESLA: POWERWALL 3 1707000-XX-Y <br />ENABLE PCS <br />SETPOINTS: <br />- 180A - MAXIMUM TOTAL CURRENT ON THE CONTROLLED PANEL <br />- 0A - FAIL SAFE GENERATION BACKFEED CURRENT SUPPLY (120% COMPLIANT) <br />MODULE CHARACTERISTICS <br />SILFAB: SIL-440QD-DCA 440 W <br />OPEN CIRCUIT VOLTAGE 38.97 V <br />MAX POWER VOLTAGE 33.41 V <br />SHORT CIRCUIT CURRENT 14.22 A