Laserfiche WebLink
GENERAL NOTESABBREVIATIONSAPPLICABLE STANDARDS <br />ANNOTATION SYMBOLS <br />LEGENDLEGEND <br />E0.1 SYMBOLS, DESIGNATION AND ABBREVIATIONS <br />E0.2 SINGLE LINE DIAGRAM <br />E0.3 ELECTRICAL SCHEDULES <br />E0.4 TITLE-24 COMPLIANCE FORMS <br />E1.1 PARTIAL FIRST FLOOR DEMOLITION PLAN <br />E2.1 PARTIAL FIRST FLOOR POWER INSTALLATION PLAN <br />E2.2 ROOF POWER PLAN <br />E3.1 PARTIAL FIRST FLOOR LIGHTING INSTALLATION PLAN <br />E3.2 PARTIAL FIRST FLOOR NORMAL AND EMERGENCY <br />PHOTOMETRICS PLANS <br />E5.1 ELECTRICAL DETAILS <br />E7.1 ELECTRICAL SPECIFICATIONS <br />E7.2 ELECTRICAL SPECIFICATIONS <br />E7.3 ELECTRICAL SPECIFICATIONS <br />E7.4 ELECTRICAL SPECIFICATIONS <br />1.ELECTRICAL CONTRACTOR SHALL PERFORM ELECTRICAL <br />INSTALLATION WORK IN CONFORMANCE WITH THE 2022 <br />EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC) AND <br />ALL APPLICABLE CODES, ORDINANCES, REGULATIONS AND <br />CITY/COUNTY STANDARDS. <br />2.CONDUIT ROUTING AND OUTLET LOCATION AS SHOWN ON <br />THE ELECTRICAL POWER PLAN ARE DIAGRAMMATIC IN <br />NATURE. VERIFY FEASIBILITY OF THE INSTALLATION <br />BEFORE COMMENCING THE JOB. ANY OBSERVATIONS TO <br />THE EXECUTION OF THE WORK SHALL BE BROUGHT TO <br />THE ATTENTION OF THE OWNER'S REPRESENTATIVE <br />IMMEDIATELY. <br />3.COORDINATE ALL WORK WITH OTHER CONSTRUCTION. <br />NOTIFY THE OWNER'S REPRESENTATIVE OF ANY <br />UNRESOLVED ISSUES THAT MAY DELAY INSTALLATION OF <br />WORK. <br />4.MAINTAIN PROPER WORKING SPACE PER CALIFORNIA <br />ELECTRICAL CODE (CEC), PARAGRAPH 110-26. <br />5.PROVIDE NECESSARY HARDWARE AND SUPPORTS AS <br />REQUIRED FOR ELECTRICAL CONDUIT/WIRE NOT <br />SCHEDULED FOR DEMOLITION PER CALIFORNIA <br />ELECTRICAL CODE (CEC), PARAGRAPH 110-12. <br />6.CONNECTIONS TO VIBRATING EQUIPMENT AND SEISMIC <br />SEPARATIONS: <br />·LIQUID-TIGHT FLEXIBLE STEEL CONDUIT IN DRY <br />INTERIOR LOCATIONS. <br />·LIQUID-TIGHT FLEXIBLE STEEL CONDUIT IN AREAS <br />EXPOSED TO WEATHER, DAMP LOCATIONS, <br />CONNECTIONS TO TRANSFORMER ENCLOSURES, AND <br />FINAL CONNECTIONS TO MOTORS. <br />PROVIDE A SEPARATE INSULATED EQUIPMENT GROUNDING <br />CONDUCTOR IN FLEXIBLE CONDUIT RUNS. MAXIMUM <br />LENGTH SHALL BE SIX FEET UNLESS OTHERWISE NOTED. <br />7.EQUIPMENT OUTLETS, LIGHTING FIXTURES, CONDUIT, <br />WIRE, AND CONNECTION METHODS IN HVAC AIR-PLENUMS <br />SHALL BE APPROVED FOR USE IN PLENUMS AND SHALL <br />CONFORM TO THE CEC. <br />8.ROUTE EXPOSED CONDUIT AND CONDUIT ABOVE <br />ACCESSIBLE CEILING SPACES PARALLEL AND <br />PERPENDICULAR TO WALLS AND ADJACENT PIPING. <br />ARRANGE CONDUIT TO MAINTAIN HEADROOM AND TO <br />PRESENT A NEAT APPEARANCE. <br />9.WHENEVER A DISCREPANCY IN QUANTITY OR SIZE OF <br />CONDUIT, WIRE, EQUIPMENT DEVICES, CIRCUIT BREAKERS, <br />GROUND FAULT PROTECTION SYSTEMS, ETC. (ALL <br />MATERIALS), ARISES ON THE DRAWINGS OR <br />SPECIFICATIONS, PROVIDE AND INSTALL ALL MATERIAL <br />AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS <br />NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO <br />ENSURE COMPLETE AND OPERABLE SYSTEMS. <br />10.ALL RECESSED LIGHTING FIXTURES, SPEAKERS, <br />RECEPTACLES, SWITCHES, ETC., MOUNTED IN THE FIRE <br />RATED CEILINGS OR WALLS SHALL BE ENCLOSED WITH AN <br />APPROVED ENCLOSURE CARRYING THE SAME FIRE RATING <br />AS THE CEILING OR WALL. <br />2022 CALIFORNIA BUILDING CODE (CBC) PART 2, <br />VOLUMES 1 AND 2, TITLE 24 <br />(BASED ON 2021 INTERNATIONAL BUILDING CODE) <br />2022 CALIFORNIA ELECTRIC CODE (CEC) PART 3, TITLE 24 <br />(BASED ON 2020 NATIONAL ELECTRIC CODE) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) PART 4, TITLE 24 <br />(BASED ON 2021 UNIFORM MECHANICAL CODE) <br />2022 CALIFORNIA PLUMBING CODE (CPC) PART 5, TITLE 24 <br />(BASED ON 2021 UNIFORM PLUMBING CODE) <br />2022 CALIFORNIA FIRE CODE (CFC) PART 9, TITLE 24 <br />(BASED ON 2021 INTERNATIONAL FIRE CODE) <br />2022 CALIFORNIA ENERGY CODE PART 6, TITLE 24 <br />2022 CALIFORNIA GREEN BUILDING STANDARDS (PART 11, TITLE <br />24, CCR) <br />2022 CALIFORNIA REFERENCED STANDARD CODE PART 12, <br />TITLE 24 <br />TITLE 19, PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS <br />PARTIAL LIST OF APPLICABLE NATIONAL FIRE PROTECTION <br />ASSOCIATION (NFPA) STANDARDS <br />NFPA 13, 2022 EDITION - INSTALLATION OF SPRINKLER SYSTEMS <br />(AMENDED BY CSFM) <br />NFPA 14, 2019 EDITION - INSTALLATION OF STANDPIPE AND HOSE <br />SYSTEMS (AMENDED BY CSFM) <br />NFPA 17A, 2021 EDITION - WET CHEMICAL EXTINGUISHING <br />SYSTEMS <br />NFPA 24, 2022 EDITION - INSTALLATION OF PRIVATE FIRE SERVICE <br />MAINS <br />(AMENDED BY CSFM) <br />NFPA 25, (2013 CALIFORNIA EDITION, BASED ON NFPA 25, 2011 <br />EDITION) - INSPECTION, TESTING, & MAINTENANCE OF <br />WATER-BASED FIRE PROTECTION SYSTEMS <br />NFPA 72, 2022 EDITION - NATIONAL FIRE ALARM AND SIGNALING <br />CODE (AMENDED BY CSFM) <br />NFPA 80, 2022 EDITION - FIRE DOORS AND OTHER OPENING <br />PROTECTIVES <br />REFER TO CBC CHAPTER 35 FOR ADDITIONAL STANDARDS NOT <br />PROVIDED ON THIS LIST <br />WIRING SYSTEM ABOVE FLOOR LEVEL, <br />CONCEALED IN WALL OR ABOVE CEILING U.O.N <br />WIRING SYSTEM IN OR UNDER FLOOR OR <br />CONCEALED IN OR BEHIND STRUCTURE OR <br />EQUIPMENT <br />CONDUIT STUB ENDING WITH CAP <br />E0.1 <br />1 <br />REMOVE/RELOCATE/DEMOLISH <br />EQUIPMENT/DEVICE <br />EXISTING <br />DRAWING INDEX <br />DUPLEX RECEPTACLE 20A, 5-20R <br />+18" A.F.F. (U.O.N.) <br />GROUND CONNECTION <br />COMBINATION MOTOR <br />STARTER/DISCONNECT SWITCH <br />(NUMBER INDICATES STARTER SIZE) <br />DISCONNECT SWITCH (FUSED), <br />HORSE POWER RATED <br />SURFACE MOUNTED PANELBOARD 277V/480V <br />DISTRIBUTION BOARD <br />MOTOR <br />3/4" CONDUIT WITH 2#12 + 1#12 GRD. <br />SURFACE MOUNTED PANELBOARD 120V/208V <br />DISCONNECT SWITCH (NON-FUSED) <br />S <br />S 3 <br />PLUGMOLD STRIP <br />DOUBLE DUPLEX (QUAD) RECEPTACLE <br />20A, 5-20R, +18" A.F.F. (U.O.N.) <br />LIGHTING FIXTURE IDENTIFICATION <br />SURFACE MOUNTED METAL <br />SINGLE/DUAL CHANNEL RACEWAY FOR <br />RECEPTACLES AND DATA, REFER TO <br />PLANS FOR RECEPTACLE/DATA <br />LOCATION. <br />W W <br />TELECOM BACKBOARD 8'x4'x3/4", FIRE <br />TREATED. PROVIDE 1#6 GROUND WIRE <br />TO SYSTEM GROUND <br />FX-1 <br />COMMUNICATION OUTLET. 4S BOX WITH 1 <br />GANG PLASTER RING. PROVIDE 1" CONDUIT <br />STUBBED INTO ACCESSIBLE CEILING SPACE. <br />"3" INDICATES QUANTITY OF PLENUM RATED <br />CAT-6 CABLES. (2 DATA AND 1 VOICE) <br />+18" A.F.F. (UNLESS NOTED OTHERWISE) <br />208V RECEPTACLE <br />+18" A.F.F. (U.O.N.) <br />(NEMA CONFIGURATION AS NOTED ON PLANS) <br />MANUAL MOTOR STARTER SWITCH <br />WITH THERMAL OVERLOADS <br />RATED AT 250V-30A-2P <br />JUNCTION BOX WITH COVER <br />(MINIMUM 4" SQUARE OR AS REQUIRED) <br />120/277V. 20A LIGHT SWITCH <br />(+42" A.F.F.) <br />DENOTES 3-WAY SWITCH (+42" A.F.F.) <br />LOW VOLTAGE ON/OFF DIMMER SWITCH <br />(+42" A.F.F.) <br />LOW VOLTAGE CEILING MOUNTED <br />OCCUPANCY SENSOR <br />LOW VOLTAGE LIGHTING CONTROLS <br />POWER/RELAY PACK, <br />'EM' INDICATES EMERGENCY CIRCUIT <br />R EM <br />LOW VOLTAGE ON/OFF MANUAL SWITCH <br />WITH OCCUPANCY SENSOR (+42" A.F.F.) <br />CARD READER (+42" A.F.F.) <br />2-POLE TOGGLE SWITCH FOR <br />MECHANICAL UNIT <br />J <br />ELECTRICAL <br />SYMBOL <br />DESCRIPTION ELECTRICAL <br />SYMBOL <br />DESCRIPTION <br />GFCI DUPLEX RECEPTACLE <br />20A, 5-20R, +42" A.F.F. (U.O.N.) <br />CR <br />DM <br />OS <br />F <br />1 <br />SHEET WHERE DETAIL IS DRAWN <br />OCCURRENCE <br />DETAIL IDENTIFICATION <br />(TYP.) <br />DETAIL <br />GFCI DUPLEX RECEPTACLE 20A, 5-20R <br />+18" A.F.F. (U.O.N.) <br />3 <br />CS <br />1 <br />INSTALLATION KEY NOTE <br />DEMOLITION KEY NOTE <br />REVISION <br />REVISED AREA <br />REVISION TAG <br />A AMPERE <br />AC ALTERNATING CURRENT <br />AF AMPERE FUSE <br />AS AMPERE SWITCH <br />AFC ABOVE FINISHED CEILING <br />AFF ABOVE FINISHED FLOOR <br />AFG ABOVE FINISHED GRADE <br />AIC AMPERE INTERRUPTING CAPACITY <br />ANN ANNUNCIATOR <br />AT AMPERE TRIP <br />ATS AUTOMATIC TRANSFER SWITCH <br />AV AUDIO-VISUAL <br />AWG AMERICAN WIRE GAUGE <br />BKR BREAKER <br />BLDG BUILDING <br />C CONDUIT <br />CB CIRCUIT BREAKER <br />CATV CABLE TELEVISION <br />CEC CALIFORNIA ELECTRICAL CODE <br />CKT CIRCUIT <br />CLG CEILING <br />CO CONDUIT ONLY <br />COMM COMMUNICATIONS <br />COMP COMPUTER <br />DB DISTRIBUTION BOARD <br />DISC DISCONNECT <br />DIST DISTRIBUTION <br />DL DOUBLE LUG <br />DP DISTRIBUTION PANEL <br />DWG DRAWING <br />E EXISTING TO REMAIN <br />EG EQUIPMENT GROUND <br />ELEC ELECTRICAL <br />EM EMERGENCY <br />EMT ELECTRICAL METALLIC TUBING <br />EQUIP EQUIPMENT <br />F FUSE, FUSED <br />FA FIRE ALARM <br />FACP FIRE ALARM CONTROL PANEL <br />FLA FULL LOAD AMPERES <br />GD GARBAGE DISPOSER <br />GRD GROUND <br />GALV GALVANIZE, GALVANIZED <br />GEN GENERATOR <br />GFCI GROUND FAULT CIRCUIT INTERRUPTER <br />HP HORSEPOWER <br />IHW INSTA-HOT WATER HEATER <br />JB JUNCTION BOX <br />KA THOUSAND AMPERES <br />KCMIL THOUSAND CIRCULAR MILS <br />KVA KILOVOLT-AMPERE <br />KW KILOWATT <br />LTG LIGHTING <br />MC METAL CLAD CABLE <br />MCB MAIN CIRCUIT BREAKER <br />MCM THOUSAND CIRCULAR MILS <br />MDP MAIN DISTRIBUTION PANEL <br />MFR MANUFACTURER <br />MIN MINIMUM <br />MLO MAIN LUGS ONLY <br />MTD MOUNTED <br />MTR MOTOR <br />NEC NATIONAL ELECTRIC CODE <br />NF NON-FUSED <br />NIC NOT IN CONTRACT <br />P POLE, POLES <br />PF POWER FACTOR <br />PNL PANEL <br />PRI PRIMARY <br />PWR POWER <br />PH PHASE <br />Ø PHASE <br />R REMOVE <br />RR REMOVE AND RELOCATE <br />RL RELOCATED <br />RECEPT RECEPTACLE <br />RGS RIGID GALVANIZED STEEL CONDUIT <br />SEC SECONDARY <br />SUSP SUSPEND, SUSPENDED <br />SW SWITCH <br />SWBD SWITCHBOARD <br />SWGR SWITCHGEAR <br />TBB TELECOMMUNICATIONS BACKBOARD <br />TMH TELECOMMUNICATIONS MAN HOLE <br />THH TELECOMMUNICATIONS HAND HOLE <br />TR TAMPER RESISTANT <br />TYP.TYPICAL <br />TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION <br />UON UNLESS OTHERWISE NOTED <br />V VOLT, VOLTS <br />VA VOLT-AMPERES <br />VAV VARIABLE AIR VOLUME <br />WT WATERTIGHT <br />W WATT OR WIRE <br />WP WEATHER PROOF <br />X'FMR TRANSFORMER <br />Y WYE CONNECTION <br />S M <br />S 2 <br />MISCELLANEOUS <br />LINE TYPESGROUND BUS BAR <br />1 <br />1 <br />CAMERA <br />METERM <br />CIRCUIT BREAKER <br />LV TRANSFORMER <br />T TRANSFORMER <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Drive <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />17582 Fiesta Way, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />. <br />255 E. Rincon St., Suite 301 <br />Corona, CA 92879 <br />P 951.340.1977 | F 951.340.1090 <br />www.gossengineering.com <br />CALOFI <br />GI <br />RE <br />NG <br />A <br />E <br />S <br />No. E17083 <br />T <br />E <br />ET <br />SAT L CE A <br />F <br />RICL <br />ORNI <br />EPR <br />RAET <br />RED D.D <br />OF ONABR <br />L <br />SSI <br />NE <br />RE <br />IWD <br />UT <br />HCE <br />Project Number: 125-09-07 <br />Date Signed 01-09-2026 <br />1 01/09/2026 PLAN CHECK RESUBMITTAL <br />SYMBOLS, <br />DESIGNATION AND <br />ABBREVIATIONS <br />E0.1