Laserfiche WebLink
1 <br />1 <br />EXIST RR <br />EXISTING OFFICE <br />AREA <br />EXIST RR <br />EXIST ELEC <br />EXISTING <br />WAREHOUSE <br />AREA <br />PROJECT AREA <br />(ASSEMBLY SPACE) <br />APPROX 3,450 SF <br />DM a <br />DM <br />a <br />FX-1 <br />(TYP.) <br />FX-1E <br />(TYP.) <br />EX-1 <br />TYP. <br />EX-1 <br />(TYP.) <br />2 <br />3 <br />EM <br />EM <br />EM <br />EM <br />EM <br />EM <br />EM <br />EM <br />PANEL 5HP <br />PANEL 5HL <br />PANEL 5LA <br />PANEL 5PA PANEL 5PB <br />EMEM <br />EM <br />EM <br />EM <br />EM <br />CS a <br />CS a <br />CS a <br />CS aCSaCSa <br />CS aCSaCSa <br />CS aCSaCSa <br />CS a <br />(TYP.) <br />4 (TYP.) <br />S <br />EM <br />15a15a <br />15a <br />15a <br />15a 15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />15a 15a <br />15a <br />15a <br />15a <br />15a <br />15a 15a <br />15a <br />15a <br />15a <br />15a <br />15a <br />J <br />15 <br />J <br />5LA-15,17 <br />3/4"C - 4#12 & 1#12 GRD. <br />17b 17b 17b <br />17 <br />1 <br />1 <br />FX-2E <br />(TYP.) <br />S b <br />GENERAL NOTES: <br />1.ELECTRICAL ENGINEERING FOR THIS PROJECT IS BASED <br />ON A FIELD VISIT OF THE ELECTRICAL SYSTEM. IN CASE OF <br />ANY DISCREPANCIES WITH EXISTING FIELD CONDITIONS, <br />ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT <br />DIFFERENCES AND NOTIFY THE ELECTRICAL ENGINEER <br />FOR POSSIBLE REVISION TO THESE DOCUMENTS. <br />2.ANY ELECTRICAL AND/OR SIGNAL UTILITY SHUTDOWNS <br />WITHIN THE AREA OF WORK SHALL BE COORDINATED AND <br />SCHEDULED IN ADVANCE WITH THE OWNER'S <br />REPRESENTATIVE. <br />INSTALLATION NOTES: <br />NEW LED FIXTURE. REFER TO LIGHT FIXTURE SCHEDULE <br />ON SHEET E0.03 FOR ADDITIONAL INFORMATION. <br />PROVIDE WALL MOUNTED DIMMER SWITCH <br />(NPODMA-DX-WH). REFER TO SHEET E5.01 DETAIL 2 FOR <br />NLIGHT ENABLED WIRING INFORMATION. <br />PROVIDE A SURFACE MOUNTED SPST TOGGLE TYPE LIGHT <br />SWITCH. <br />PROVIDE CEILING MOUNTED OCCUPANCY SENSOR <br />(NCM-PDT-10). REFER TO SHEET E5.01 DETAIL 2 FOR NLIGHT <br />ENABLED WIRING INFORMATION. <br />1 <br />2 <br />3 <br />4 <br />SCALEKEY PLAN 0N.T.S. <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Drive <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />17582 Fiesta Way, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />. <br />255 E. Rincon St., Suite 301 <br />Corona, CA 92879 <br />P 951.340.1977 | F 951.340.1090 <br />www.gossengineering.com <br />CALOFI <br />GI <br />RE <br />NG <br />A <br />E <br />S <br />No. E17083 <br />T <br />E <br />ET <br />SAT L CE A <br />F <br />RICL <br />ORNI <br />EPR <br />RAET <br />RED D.D <br />OF ONABR <br />L <br />SSI <br />NE <br />RE <br />IWD <br />UT <br />HCE <br />Project Number: 125-09-07 <br />Date Signed 01-09-2026 <br />1 01/09/2026 PLAN CHECK RESUBMITTAL <br />PARTIAL FIRST FLOOR <br />LIGHTING <br />INSTALLATION PLAN <br />E3.1SCALEPARTIAL FIRST FLOOR LIGHTING PLAN 11/4" = 1'-0" <br />PROJECT <br />LOCATION <br />1 1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1