EXIST RREXIST RR <br />EXIST ELEC <br />PROJECT AREA <br />(ASSEMBLY SPACE) <br />APPROX 3,450 SF <br />P5.1 <br />5 CONDENSATE DRAIN TO <br />TAILPIECE SEE DETAIL (TYP) <br />3/4" CD <br />S-1 <br />2 <br />1 <br />4 <br />3 <br />1-1/2" V <br />(E) SS <br />2" SS <br />EXIST RREXIST RR <br />EXIST ELEC <br />PROJECT AREA <br />(ASSEMBLY SPACE) <br />APPROX 3,450 SF <br />1/2" HW <br />1/2" CW <br />INSTANTANEOUS <br />WATER HEATER <br />IHW-1 <br />S-1 <br />P5.1 <br />8 <br />1 <br />(E)2" CW <br />(E)2" CW <br />1/2" CW <br />SCALEKEY PLAN 0N.T.S. <br />SCALEPARTIAL FIRST FLOOR INSTALLATION WASTE AND VENT PLAN 21/4" = 1'-0" <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Drive <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />17582 Fiesta Way, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />. <br />255 E. Rincon St., Suite 301 <br />Corona, CA 92879 <br />P 951.340.1977 | F 951.340.1090 <br />www.gossengineering.com <br />CALOFI <br />GI <br />RE <br />NG <br />A <br />E <br />S <br />A <br />M <br />ET <br />SAT E HC A <br />F <br />NIC L <br />ORNI <br />EPR <br />ET <br />RED <br />OF ONAL <br />SSI <br />NE <br />RE <br />I <br />No. M36781 <br />Exp. 3-31-26 <br />YRNEGA.WAHS <br />T <br />Project Number: 125-09-07 <br />Date Signed 10-30-25 <br />Partial First Floor <br />Domestic Water and <br />Waste/Vent Plans <br />P2.0SCALEPARTIAL FIRST FLOOR INSTALLATION CW/HW PLUMBING PLAN 11/4" = 1'-0" <br />PROJECT <br />LOCATION <br />GENERAL NOTES: <br />1.DRAWINGS ARE DIAGRAMMATIC IN NATURE, ACTUAL <br />EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO <br />CONSTRUCTION EFFORT. <br />2.SHUTDOWNS TO THE BUILDING SHALL BE COORDINATED <br />WITH THE OWNER'S REPRESENTATIVE. <br />3.REFER TO 6/P5.1 FOR INTERIOR CLEANOUT INSTALLATION. <br />4.ALL CONDENSATE ROUTING SHALL BE INSTALLED AT A <br />SLOPE OF 1% IN THE DIRECTION OF FLOW. <br />INSTALLATION NOTES: <br />3/4" CONDENSATE DRAIN DOWN THROUGH ROOF FROM <br />AC-1. <br />3/4" CONDENSATE DRAIN DOWN THROUGH ROOF FROM <br />AC-2. <br />1-1/2" V UP THROUGH ROOF. <br />NEW SANITARY WASTE LINE TO BE CONNECTED TO (E) <br />SANITARY WASTE BELOW GRADE, PATCHBACK CONCRETE <br />AND MATCH ADJACENT FINISHES. <br />1 <br />2 <br />3 <br />4 <br />GENERAL NOTES: <br />1.DRAWINGS ARE DIAGRAMMATIC IN NATURE, ACTUAL <br />EXISTING CONDITIONS SHALL BE FIELD VERIFIED PRIOR TO <br />CONSTRUCTION EFFORT. <br />2.SHUTDOWNS TO THE BUILDING SHALL BE COORDINATED <br />WITH THE OWNER'S REPRESENTATIVE. <br />3.REFER TO DETAILS 1,2/P5.1 FOR PIPE HANGER SUPPORTS. <br />4.REFER TO DETAILS 3,4/P5.1 FOR PIPE PENETRATIONS. <br />5.REFER TO DETAIL 7/P5.1 FOR PIPE INSULATION <br />REQUIREMENTS. <br />INSTALLATION NOTES: <br />CONTRACTOR TO FIELD VERIFY (E) CONDITIONS PRIOR TO <br />INSTALLATION. <br />1