Laserfiche WebLink
EXIST RREXIST RR <br />EXIST ELEC <br />EXIST <br />OFFICE <br />AREA <br />EXIST <br />WAREHOUSE <br />AREA <br />STAGING & <br />SET-UP <br />100 <br />ROOF <br />ACCESS <br />101 <br />NO CEILING <br />10'-0" <br />1 <br />2 <br />3 <br />4 <br />(TYP OF 3) <br />5 <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Road <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />333 El Camino Real #201, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />10/31/25 Plan Check Submittal <br />. <br />GENERAL NOTES <br />KEYNOTES <br />LEGEND <br />(E) LADDER TO ROOF <br />POWER POLE, PER ELEC PLANS <br />LINE OF UPPER CABINET, TYP <br />PROVIDE SLOT OPENING IN CEILING FOR ROLL-UP DOOR <br />1.MECHANICAL GRILLES, REGISTERS, AND ELECTRICAL FIXTURES ARE <br />SHOWN FOR LOCATION PURPOSES ONLY. REFER TO MEP DRAWINGS. <br />2.REFER TO SHEET A-8.3 FOR CEILING SYSTEM NOTES AND DETAILS. <br />3.LIGHT FIXTURES LOCATED UNDERNEATH HVAC DUCT LOOP WILL BE <br />REQUIRED TO BE SUPPORTED BY A UNISTRUT SUPPORT SYSTEM. LIGHT <br />FIXTURES WITH LIMITED CLEARANCE SHALL BE SPECIFIED WITH REMOTE <br />BALLAST. <br />4.THERE SHALL BE NO ACCESS PANEL IN GYPSUM BOARD CEILING. <br />LOCATE ALL ACCESSIBLE EQUIPMENT WITHIN THE ACOUSTICAL CEILING <br />AREA. <br />5.ALL SPRINKLER HEADS TO BE CONCEAL TYPE AT GYPSUM BOARD & <br />T-BAR CEILING. <br />6.ALL LAMPING TO BE IN 3000K. U.N.O. <br />ACOUSTICAL TILE <br />2x2 SUPPLY AIR GRILLE <br />2x2 RETURN AIR GRILLE <br />INDICATES AREA NOT IN PROJECT SCOPE <br />A-8.3 <br />02 <br />EXHAUST AIR GRILLE <br />LIGHT FIXTURES - SEE ELECTRICAL DRAWINGS <br />MECH. REGISTERS - SEE MECHANICAL DRAWINGS <br />24x48 LIGHT FIXTURE <br />EXIT SIGN (MATCH BUILDING STANDARD): <br />PROVIDE ALL ILLUMINATED AND NON-ILLUMINATED EXIT SIGNS AS INDICATED ON THE <br />DRAWINGS AND AS REQUIRED BY THE LOCAL GOVERNING AUTHORITIES AND THE <br />CALIFORNIA BUILDING CODE 1003.2.8. <br />WALL-MOUNT LIGHT FIXTURE <br />UNDER CABINET LIGHT PER ELECTRICAL PLANS <br />A-3.0 <br />AS NOTED <br />KEY PLAN <br />652 EAST DYER ROAD <br />SANTA ANA <br />FIRST FLOOR <br />REFLECTED <br />CEILING PLAN: <br />First Floor <br />REFLECTED CEILING PLAN <br />SCALE: 1/4" = 1'-0"FIRST FLOOR <br />EQUIPMENT SCHEDULE <br />TA <br />G <br />EQ <br />U <br />I <br />P <br />M <br />E <br />N <br />T <br />EQUIPMENTLOCATION <br />REMARKS <br />SIZE (") <br />WI <br />D <br />T <br />H <br />DE <br />P <br />T <br />H <br />HE <br />I <br />G <br />H <br />T <br />WE <br />I <br />G <br />H <br />T <br /> <br />( <br />l <br />b <br />s <br />) <br />AN <br />C <br />H <br />O <br />R <br />A <br />G <br />E <br />DE <br />T <br />A <br />I <br />L <br />EQ <br />U <br />I <br />P <br />M <br />E <br />N <br />T <br />NO <br />T <br />E <br />S <br />MANUFACTURER MODEL <br />## <br />INSTALLED BY OWNER <br />FURNISHED BY OWNER, <br />INSTALLED BY CONTRACTOR <br />FURNISHED BY OWNER, <br />INSTALLED BY CONTRACTOR <br />FURNISHED BY CONTRACTOR, <br />OFCI <br />OFOICFCI <br />ABBREVIATIONS <br />INSTALLED BY VENDOR <br />FURNISHED BY VENDOR,VFVI <br />01 Break Area Refrigerator --OFCI ------- <br />EQUIPMENT NOTES <br />TA <br />G <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br />DESCRIPTION MANUFACTURER/BACKING <br />## <br />B <br />SOAP DISPENSER ----A <br />PAPER TOWEL DISPENSER B-2621 <br />MOUNT <br />RE <br />C <br />E <br />S <br />S <br />E <br />D <br />SU <br />R <br />F <br />A <br />C <br />E <br />NOTE ALL ACCESSORIES CONTRACTOR FURNISHED / CONTRACTOR INSTALLED (CF/CI) <br />REFER TO DETAIL 25/G-0.0 FOR ACCESSIBLE MOUNTING HEIGHTS. <br />SANITARY ACCESSORIES <br />1. ALL OWNER-FURNISHED EQUIP. MANUFACTURERS, MODEL NUMBERS, AND SIZES IN THIS SCHEDULE ARE BASED ON <br />INFORMATION SUPPLIED TO THE ARCHITECT BY THE OWNER AND ARE SUBJECT TO CHANGE. VERIFY ALL EQUIP. <br />SPECIFICATIONS WITH THE OWNER PRIOR TO CONSTRUCTION. <br />2. VERIFY ALL REQUIREMENTS FOR CONTRACTOR PREPPED/VENDOR INSTALLED ITEMS WITH EQUIPMENT <br />MANUFACTURER. <br />3. RECEIVE, DOCUMENT, INSPECT, SCHEDULE AND INSTALL ALL ITEMS NOTED AS FURNISHED BY OWNER AND INSTALLED <br />BY CONTRACTOR. <br />Bobrick <br />MODEL DETAIL <br />-- <br />02 Break Area Microwave Oven --OFCI ------- <br />03 Break Area Coffee Maker --OFCI -------