Laserfiche WebLink
100 STAGING & SET-UP <br />SCALE: 3/8" = 1'-0"03 <br />C <br />100 STAGING & SET-UP <br />SCALE: 3/8" = 1'-0"15 <br />D <br />F02 <br />02 <br />B19 <br />W01 W01 <br />S01S B07 <br />W04 <br />3'-4" <br />7'-0" <br />2'-4"2'-4" <br />1 1/2" <br />2'-4"2'-3" <br />(2) EQ. <br />1'-9"3'-0" <br />6 7 <br />1'-0"3/4" <br />W01 <br />03 <br />A B <br />01 <br />6' <br />- <br />2 <br />" <br />1' <br />- <br />1 <br />0 <br />" <br />2' <br />- <br />1 <br />0 <br />" <br />2' <br />- <br />2 <br />" <br />3' <br />- <br />0 <br />" <br />B13 <br />1'-3" <br />11 11 <br />4 <br />5 5 <br />4 <br />10 <br />31 <br />2 <br />9 <br />8 <br />Sheet No. <br />Project <br />Agency Plan Check / Permit No. <br />Petersen Design Project No. <br />Consultant <br />5082.1 <br />652 East Dyer Road <br />Santa Ana, CA 92705 <br />DYER WAREHOUSE <br />Staging & Set-Up Space <br />Tenant Improvements <br />Sheet Title <br />Revision / Submittal History <br />Scale <br />Status <br />. <br />architecture + planning <br />Agency Approval <br />Petersen Design Architects, Inc. <br />333 El Camino Real #201, Tustin, CA 92780 <br />M: 714.904.6720 E: mike@mpdarch.com <br />www.mpdarch.com <br />Architect's Stamp <br />10/31/25 Plan Check Submittal <br />. <br />DUPLEX OUTLET <br />DOUBLE-DUPLEX OUTLET <br />COMMUNICATIONS OUTLET <br />NOTE <br />1. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. <br />GENERAL NOTES <br />KEYNOTES <br />LEGEND <br />W WATER CONNECTION <br />1.WALLS AND PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS, AND WATER <br />CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE TO A HEIGHT <br />OF NOT LESS THAN 4 FEET ABOVE THE FLOOR, AND THE MATERIALS IN SUCH <br />WALLS SHALL NOT BE ADVERSELY AFFECTED BY MOISTURE. <br />2.ELECTRICAL, TELEPHONE AND COMMUNICATION OUTLETS ARE TO BE MOUNTED <br />VERTICALLY WITH CENTERLINE OF BOX AT 18" AFF (16" AFF TO BOTTOM OF BOX, <br />MINIMUM), UNO. ALL SWITCHES AND OTHER CONTROLS TO BE INSTALLED 48" AFF <br />TO TOP OF BOX MAXIMUM. <br />3. SEAL AROUND ALL JOINTS AT CABINETS AND COUNTERTOPS. <br />4. GRAIN PATTERN ON ALL WOODGRAIN LAMINATES TO RUN VERTICALLY, UNO. <br />5. ALL FINISHES TO CONTINUE BEHIND AND UNDERNEATH ALL EQUIPMENT, <br />ACCESSORIES, AND MOVEABLE CASEWORK. <br />6. REFER TO DETAIL 25/A-8.2 FOR BACKING DETAIL. <br />VERIFY FINAL EQUIPMENT PLACEMENT WITH OWNER. <br />7. REFER TO DETAIL 20/G-0.0 FOR ACCESSIBLE REACH RANGES. <br />8. REFER TO DETAIL 25/G-0.0 FOR ACCESSIBLE MOUNTING HEIGHTS. <br />9. REFER TO CASEWORK DETAILS, SHEET A-8.2, FOR CABINET TYPES: W01, B01, ETC. <br />ROLL-UP DOOR PER SCHEDULE <br />ROLL-UP DOOR TRACK <br />DOOR PER SCHEDULE <br />ACOUSTICAL PANEL CEILING PER CEILING PLAN <br />OPENING IN WALL - REFER TO MECHANICAL PLANS <br />SINK PER PLUMBING PLANS <br />TOE SPACE, TYP <br />BACKSPLASH, TYP <br />UNDER CABINET LIGHT PER ELECTRICAL PLANS <br />PLASTIC LAMINATE SOFFIT CLOSURE PANEL, REFER TO DETAIL 07/A-8.2 <br />(E) WINDOW <br />AS NOTED <br />A-7.0 <br />INTERIOR <br />ELEVATIONS & <br />SCHEDULES