My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26 Civic Center Plz - REV 6 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Civic Center Plz
>
26 Civic Center Plz
>
26 Civic Center Plz - REV 6 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 1:27:25 PM
Creation date
2/25/2026 1:26:58 PM
Metadata
Fields
Template:
Plan
Permit Number
20181364
20184057
30146548
40138556
40139543
101117272
101117273
101117274
101117275
101117276
101117286
101120941
101121751
Full Address
26 Civic Center Plz
Street Number
26
Street Name
Civic Center
Street Suffix
Plz
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
J <br />111 <br />1 <br />3 <br />2 <br />22 <br />W P <br />W P <br />LP- 17 <br />4 <br />#10 <br />5 <br />W P <br />37 <br />LBM-37&39&41 <br />3/4", 4#10 & 1#10GND <br />7 (1) 1"C, 4#10 & 1#10 GND <br />(POWER) <br />(1) 1-1/4"C, 8#14 (THWN) <br />(CONTROLS) LABEL <br />CONDUCTORS 1 THRU 8 <br />6 <br />(2) 2"C FOR <br />CONNECTION TO <br />PUMPS AND CONTROL <br />SD16 <br />11 <br />#10 1"C, 4#8, 1#10GNDLBB-48 <br />LBB-50,52,54 <br />LBA-38&40 <br />40 <br />40 <br />38 <br />38 <br />9 <br />8 <br />8 <br />10 <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO.N <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />E1.0-1 <br />ELECTRICAL <br />POWER SITE PLAN <br />1/16" = 1'-0"1 ELECTRICAL SITE PLAN <br />GENERAL NOTES <br />KEY NOTES <br />1 PROVIDE 13" X 19" HANDHOLE TO TERMINATE NEW CONDUITS WITH PULL <br />STRINGS FOR FUTURE EV CHARGERS. PROVIDE WITH FLUSH SOLID BOLT <br />DOWN COVER AND MARKING PLATE "EV CHARGER INFRASTRUCTURE". <br />1.ALL OUTDOOR EQUIPMENT SHALL BE WEATHERPROOF (NEMA 3R) <br />ENCLOSURE. <br />2.ALL OUTDOOR RECEPTACLES SHALL BE PROVIDED AS GFCI, WEATHER <br />RESSITANT AND WITH WHILE-IN-USE COVERS. <br />3.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND <br />OFFSET MINIMUM 24 INCHES. <br />4.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED <br />FROM SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR <br />GREATER THAN THE FIRE RATING OF THE WALL. <br />5.ALL DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO <br />ROUGH-IN. <br />6.EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL <br />CONFORM TO CEC, ARTICLE 300.22(C). <br />7.PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN <br />CIRCUITRY <br />8.PROVIDE DEDICATED NEUTRAL FOR EACH NEW CIRCUIT, EXCEPT WHERE <br />OTHERWISE NOTED. HOME RUN CONDUCTORS MAY BE COMBINED INTO <br />ONE CONDUIT. NO RACEWAY OR CABLE SHALL CONTAIN MORE THAN NINE <br />(9) CURRENT CARRYING CONDUCTORS. WHERE MULTIPLE CONDUCTORS <br />IN EXCESS OF THREE (3) ARE INDICATED ON THESE DRAWINGS, THEY <br />HAVE BEEN DERATED AS REQUIRED BY CEC ARTICLE 310 REQUIREMENTS. <br />9.NO EQUIPMENT, J-BOXES, ETC. REQUIRING ACCESS SHALL BE LOCATED IN <br />HARD LID CEILING AREAS (UNLESS ACCESS PANEL IS PROVIDED. <br />COORDINATE WITH ARCHITECT.) RELOCATE ANY EXISTING EQUIPMENT, J- <br />BOXES, ETC. TO ACCESSIBLE CEILING AREA. <br />10. ALL DISCONNECT SWITCHES SHALL BE MOUNTED STRUCTURALLY AND <br />INDEPENDENT OF THE EQUIPMENT THEY ARE SERVING. <br />11. DISCONNECT SWITCHES SHALL BE MOUNTED ON THE WALL WITHIN <br />SIGHT OF EQUIPMENT IT SERVES. <br />12. REFER TO CIVIL DRAWINGS FOR UNDERGROUND UTILITIES. <br />2 CONTRACTOR SHALL PROVIDE 1-1/4" C TO PANEL LBB IN MAIN <br />ELECTRICAL ROOM FOR FURTURE EV CHARGER. CONTRACTOR SHALL <br />INSTALL PULL-STRING FOR CONDUIT RUN. CONTRACTOR SHALL INSTALL <br />HANDHOLES AS NEEDED FOR COMPLETE ELECTRICAL INSTALLATION. <br />COORDINATE EXACT ROUTING IN THE FIELD AND REFER TO CIVIL <br />DRAWINGS FOR EXISTING UTILITY ON SITE. <br />3 CONTRACTOR SHALL PROVIDE 1-1/2" C TO PANEL LBB IN MAIN <br />ELECTRICAL ROOM FOR FURTURE EV CHARGER. CONTRACTOR SHALL <br />INSTALL PULL-STRING FOR CONDUIT RUN. CONTRACTOR SHALL INSTALL <br />HANDHOLES AS NEEDED FOR COMPLETE ELECTRICAL INSTALLATION. <br />COORDINATE EXACT ROUTING IN THE FIELD AND REFER TO CIVIL <br />DRAWINGS FOR EXISTING UTILITY ON SITE. <br />4 EXISTING POWER CONNECTION SERVING EXISTING TO REMAIN <br />IRRIGRATION CONTROLLER. <br />REV # DESCRIPTION DATE <br />#027 ASI 08.18.2025 <br />#009.2 ASI 09.30.2025 <br />5 PROVIDE 208V 1-PHASE FOR DUPLEX PUMPS AND 120V POWER <br />CONNECTIONS FOR CONTROLS FOR NEW STORM WATER PUMP SYSTEM <br />ON SITE. CONTRACTOR SHALL PROVIDE PUMP CONTROLLER WITH <br />INTEGRAL DISCONNECT AND OVERCURRENT PROTECTION DEVICES FOR <br />EACH DUPLEX PUMP. COORDINATE EXACT LOCATION OF NEW PUMP <br />CONTROLLER IN THE FIELD PRIOR TO INSTALLATION. <br />6 PROVIDE PRECAST 13"X19" JUNCTION BOX, REFER TO SHEET E6.0-4/06 <br />W ITH REINFORCED STEEL PLATE TRAFFIC BOLT DOWN COVER AND LABEL <br />AS ELECTRICAL FOR CONNECTIONS TO DUPLEX STORM WATER PUMPS. <br />COORDINATE EXACT LOCATION OF NEW JUNCTION BOX IN THE FIELD <br />PRIOR TO INSTALLATION. <br />7 EXTEND CONDUITS INTO NEW STORM WATER PUMP VAULT AS SHOWN. <br />PROVIDE WATERTIGHT MECHANICAL WALL SEALS (LINK-SEAL® OR <br />APPROVED EQUAL) AT ALL CONDUIT PENETRATIONS. SEAL ALL <br />RACEWAYS ENTERING THE VAULT FROM UNDERGROUND WITH LISTED <br />SEALING FITTINGS OR COMPOUNDS TO PREVENT MOISTURE OR VAPOR <br />MIGRATION IN ACCORDANCE WITH NEC 300.5(G) AND 300.7(A). ALL <br />CONDUITS, FITTINGS, AND ENCLOSURES WITHIN THE VAULT SHALL BE <br />LISTED AND RATED FOR WET LOCATIONS, CORROSION RESISTANT, AND <br />INSTALLED WATERTIGHT. <br />8 PROVIDE LEGRAND GROUND BOX XB814 WITH (2) 5-20 OUTDOOR RATED <br />GFCI RECEPTACLES (XB814C520C2GY) TO BE INSTALLED IN CONCRETE <br />FLOOR. COORDINATE EXACT LOCATION WITH ARCHITECT ON-SITE. <br />9 PROVIDE LEGRAND GROUND BOX XB814 WITH (2) 5-20 OUTDOOR RATED <br />GFCI RECEPTACLES (XB814C520C2GY) TO BE INSTALLED IN WOOD DECK. <br />COORDINATE EXACT LOCATION WITH ARCHITECT ON-SITE. <br />10 PROVIDE LEGRAND OUTDOOR POWER DEDESTAL, 2-GANG DEVICE PLATE <br />WITH HINGED COVER (XPP2G16C-XX, FINISH TO BE DETERMINDED BY <br />ARCHITECT). PROVIDE WITH TWO WEATHER PROOF GFCI RECEPTACLES. <br />COORDINATE EXACT LOCATION WITH ARCHITECT ON-SITE. <br />11 PROVIDE LEGRAND OUTDOOR POWER DEDESTAL, 2-GANG DEVICE PLATE <br />WITH HINGED COVER (XPP2G16C-XX, FINISH TO BE DETERMINDED BY <br />ARCHITECT). PROVIDE WITH (1) 14-50 RECEPTACLE AND ONE (1) 5-20 <br />WEATHERPROOF GFCI RECEPTACLE. COORDINATE EXACT LOCATION <br />WITH ARCHITECT ON-SITE. <br />#009.2 <br />ASI <br />#009.2 <br />ASI
The URL can be used to link to this page
Your browser does not support the video tag.