My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
26 Civic Center Plz - REV 6 - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Civic Center Plz
>
26 Civic Center Plz
>
26 Civic Center Plz - REV 6 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2026 1:27:25 PM
Creation date
2/25/2026 1:26:58 PM
Metadata
Fields
Template:
Plan
Permit Number
20181364
20184057
30146548
40138556
40139543
101117272
101117273
101117274
101117275
101117276
101117286
101120941
101121751
Full Address
26 Civic Center Plz
Street Number
26
Street Name
Civic Center
Street Suffix
Plz
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EF <br />B-1 <br />EF <br />B-2 <br />EF <br />2-2 <br />EF <br />2-3 <br />EF <br />2-1 <br />EF <br />1-1 <br />EF <br />1-2 <br />SF <br />B-1 <br />EF <br />2-4 <br />AHU <br />B-1 <br />AHU <br />1-1 <br />CHWP <br />1-1, 2 <br />HWP <br />1-1, 2 <br />HX <br />1 <br />FC <br />B1-1 <br />CU <br />B1-1 <br />FC <br />B1-1 <br />AIR HANDLING UNIT SCHEDULE <br />STEAM-TO-WATER HEAT EXCHANGER SCHEDULE <br />PUMP SCHEDULE <br />ARCHIVES AC UNITS - AIR COOLED SCHEDULE <br />AIR-COOLED CONDENSING UNIT SCHEDULE <br /> EXHAUST FAN SCHEDULE <br /> SUPPLY FAN SCHEDULE <br />TAG <br /> NOTES <br /> 1. PROVIDE VFDS FOR SUPPLY FANS. PROVIDE INVERTER-DUTY MOTORS WITH SHAFT GROUNDING DEVICE OR INSULATED BEARINGS. <br /> 2. PROVIDE FACTORY-INSTALLED INTERNAL WIRING TO FAN MOTORS AND GFCI CONVENIENCE RECEPTACLES AS NECESSARY FOR SINGLE POINT OF ELECTRICAL CONNECTION. <br /> 3. PROVIDE (2) 120-V GFCI CONVENIENCE RECEPTACLES <br /> 4. PROVIDE VIBRATION ISOLATION AND SEISMIC RESTRAINT PER SPECIFICATIONS. <br /> 5. SEE M4.0-2 FOR INSTALLATION DETAIL. <br /> 6. PROVIDE SMOKE DETECTORS ON THE SUPPLY FOR AUTOMATIC UNIT SHUTDOWN. <br /> 7. PROVIDE NEMA PREMIUM EFFICIENCY MOTORS ON ALL FANS. <br /> 8. PROVIDE AIRFLOW MEASUREMENT STATIONS AT SUPPLY FAN <br /> 9. PROVIDE MAGNEHELIC DIFFERENTIAL PRESSURE GAUGES ACROSS EACH FILTER BANK. "RED LINE" GAUGES TO INDICATE CHANGE-OUT PRESSURE DROP. <br /> 10. PROVIDE UVC LIGHT BANK DOWNSTREAM OF THE COOLING COIL. <br />MFR & <br />MODEL <br />YORK <br />LOCATION <br />BASEMENT <br />AREA <br />SERVED <br />FIRST & SECOND FLOOR <br />SUPPLY FAN <br />AIR <br />FLOW <br />(CFM) <br />35,000 <br />MIN <br />OSA <br />(CFM) <br />3500 <br />ESP <br />(IN.WG.) <br />TSP <br />(IN.WG.) <br />QTY <br />4 <br />BHP <br />9.75 <br />DRIVE <br />DIRECT <br />V/PH <br />COILS <br />COOLING/ <br />HEATING <br />COOLING <br />HEATING <br />TOTAL <br />(MBH) <br />1384 <br />N/A <br />SENS <br />(MBH) <br />908 <br />----- <br />EAT <br />DB/WB <br />(ºF) <br />80 / 67 <br />- <br />LAT <br />DB/WB <br />(ºF) <br />55.9 / 53.8 <br />- <br />EWT <br />(ºF) <br />40 <br />- <br />LWT <br />(ºF) <br />50 <br />- <br />FLOW <br />(GPM) <br />276.4 <br />- <br />WPD <br />(FT.H2O) <br />6.6 <br />- <br />ROWS/ <br />FPI <br />4 / 11 <br />- <br />PRE-FILTER <br />SIZE <br />(12)20"X20"X1" <br />MERV <br />8 <br />FINAL FILTER <br />SIZE <br />(8)20"X24"X2" <br />MERV <br />13 <br />UNIT <br />SIZE <br />(L"xW"xH") <br />152X120X102 <br />OPER. <br />WT. <br />(LBS) <br />6018 <br />NOTES <br />1-10 <br />FIRST FLOOR YOUTH STACKS (1)24"X24"X1" 8 (1)24"X24"X2" 13 96X54X33 1600 1-10 <br />3,000 850 1.50 3.15 1 2.30 DIRECT <br />COOLING <br />HEATING <br />144 <br />254 <br />93 <br />----- <br />80 / 67 <br />20.0 <br />51.3 / 50.5 <br />100.3 <br />40 <br />180 <br />55.1 <br />140 <br />18.9 <br />13.1 <br />9.9 <br />9.5 <br />6 / 10 <br />2 / 11 <br />460/3 <br />460/3 <br />4.202.00 <br />XTI-96x120 <br />TAG <br /> NOTES <br /> 1. HEAT EXCHANGER SHALL BE CONSTRUCTED ACCORDING TO ASME REQUIREMENTS FOR PRESSURE AND TEMPERATURES <br /> 2. PROVIDE UNIT RATED FOR ASME WORKING PRESSURE OF 150 PSIG. <br />MFR & <br />MODEL <br />BELL & GOSETT <br />LOCATION <br />BASEMENT <br />SYSTEM <br />SERVED <br />HYDRONIC HOT WATER <br />TYPE <br />SHELL & TUBE <br />STEAM PRESSURE <br />(PSI) <br />80 <br />FLOW RATE <br />(LBS/HR) <br />120 <br />UNIT <br />SIZE <br />(L"xW"xH") <br />76 X 6-5/8 X 10-1/2 <br />OPER. <br />WT. <br />(LBS) <br />170 <br />NOTES <br />1,2 <br />TAG <br /> NOTES <br /> 1. VFD PROVIDED BY MECH CONTRACTOR, WIRED BY ELEC CONTRACTOR. PROVIDE INVERTER-DUTY MOTOR WITH SHAFT GROUNDING DEVICE OR INSULATED BEARINGS. <br /> 2. PROVIDE NON-OVERLOADING MOTOR WITH ODP ENCLOSURE. <br /> 3. PROVIDE NEMA PREMIUM EFFICIENCY MOTOR. <br /> 4. PROVIDE WITH FLANGE SUPPORTS <br /> 5. PROVIDE WITH INTEGRATED SENSORLESS CONTROL <br />MFR & <br />MODEL <br />BELL & GOSSET <br />LOCATION <br />BASEMENT <br />SYSTEM <br />SERVED <br />CHILLED WATER <br />TYPE <br />SPLIT COUPLED TWIN <br />FLOW <br />(GPM) <br />300 <br />HEAD <br />(FT.WG.) <br />40 <br />DUTY POINT <br />EFF. <br />(%) <br />77.9 <br />RPM <br />1707 <br />BHP <br />3.88 <br />ELECTRICAL <br />HP <br />5 <br />V/PH <br />480/3 <br />OPER. <br />WT. <br />(LBS) <br />- <br />NOTES <br />1-5 <br />BELL & GOSSET BASEMENT HOT WATER <br />CENTRIFUGAL <br />70 20 62.1 1526 .565 1.0 480/3 - 1-5 <br />SU-66-2 <br />INLET STEAM <br />e-82SC INLINE <br />e-82SC <br />2.5X2.5X7 <br />4X4X7 <br />SPLIT COUPLED TWIN <br />CENTRIFUGAL <br />INLINE <br />YORK <br />XTI-33x54 <br />TAG <br /> NOTES <br /> 1. FUSED DISCONNECT PROVIDED BY ELEC CONTRACTOR. <br /> 2. COOLING CAPACITY BASED ON 95°F AMBIENT DB. <br /> 3. PROVIDE ZONE LEAK DETECTOR. <br /> 4. PROVIDE SMOKE DETECTORS ON THE SUPPLY FOR AUTOMATIC UNIT SHUTDOWN. <br /> 5. PROVIDE NEMA PREMIUM EFFICIENCY MOTORS ON ALL FANS. <br /> 6. PROVIDE PROGRAMMABLE THERMOSTAT <br /> 7. UNIT MANUFACTURER TO PROVIDE CONTROLS INTERFACE FOR INTEGRATION WITH BMS. <br /> 8. PROVIDE CONDENSATE PUMP WITH 120 V / 1PH CONNECTION. <br />MFR & <br />MODEL <br />LIEBERT <br />LOCATION <br />CEILING <br />AREA SERVED <br />ARCHIVES 002 <br />NOM. <br />CAP. <br />(TONS) <br />3.0 <br />SUPPLY <br />AIRFLOW <br />(CFM) <br />1200 <br />ESP <br />(IN.WG.) <br />0.3 <br />HP <br />1/2 <br />DRIVE <br />DIRECT <br />COOLING <br />TOTAL <br />(MBH) <br />32.5 <br />SENS <br />(MBH) <br />28.4 <br />EAT DB/WB <br />(°F) <br />75 / 61 <br />LAT DB/WB <br />(°F) <br />51.3 / 50.5 <br />FILTER <br />SIZE <br />(1)16"X25"X4" <br />MERV <br />13 <br />ELECTRICAL <br />V/PH <br />460/3 <br />FLA <br />(A) <br />13.2 <br />WSA <br />(A) <br />16.5 <br />UNIT <br />SIZE <br />(L"xW"xH") <br />54 X 30 X 24 <br />OPER. <br />WT. <br />(LBS) <br />225 <br />NOTES <br />1-8 <br />MMD36E <br />TAG <br /> NOTES <br /> 1. FUSED DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR. <br /> 2. CAPACITY RATED AT ARI STANDARD CONDITIONS. <br /> 3. PROVIDE VIBRATION ISOLATION PER SPECIFICATIONS. <br /> 4. PROVIDE LOW AMBIENT KIT <br />MFR & <br />MODEL <br />LIEBERT <br />LOCATION <br />ROOF <br />EQUIP. <br />SERVED <br />NOM. <br />CAP. <br />(TONS) <br />3.0 <br />REFRIG <br />R-407C <br />ELECTRICAL <br />V/PH <br />460/3 <br />FLA <br />(A) <br />7.1 <br />WSA <br />(A) <br />8.7 <br />UNIT <br />SIZE <br />(L"Xw"xH") <br />48 X 18 X31 <br />OPER. <br />WT. <br />(LBS) <br />241 <br />NOTES <br />1-4 <br />PFH037A <br />OPD <br />(A) <br />20 <br />STEAM HUMIDIFIER <br />CAPACITY <br />(LBS/HR) <br />2.0 <br />POWER <br />(KW) <br />1.5 <br />ELECTRIC REHEAT <br />POWER <br />(KW) <br />7.3 <br />OPD <br />(A) <br />15 <br />TAG <br /> NOTES <br /> 1. NEMA 3R TOGGLE SWITCH PROVIDED WITH UNIT. <br /> 2. PROVIDE NON-OVERLOADING MOTOR. <br /> 3. PROVIDE NEMA PREMIUM EFFICIENCY MOTOR. <br /> 4. PROVIDE BACKDRAFT DAMPER, FACTORY ROOF CURB, & SPEED CONTROLLER. <br /> 5. EXHAUST FANS CONNECT TO DDC FOR TIMECLOCK CONTROL. <br />MFR & <br />MODEL LOCATION <br />AREA <br />SERVED DISCH TYPE DRIVE <br />AIR <br />FLOW <br />(CFM) <br />SP <br />(IN.WG.) <br />FAN <br />RPM <br />ELECTRICAL <br />HP V/PH <br />OPER. <br />WT. <br />(LBS) <br />NOTES <br />CEILING BASEMENT SIDE CENTRIFUGAL DIRECT 108 0.2 982 119WATTS 120/1 13 5-6AIRKING <br />AK110LS6 STAFF RR 010 <br />CEILING BASEMENT SIDE CENTRIFUGAL DIRECT 108 0.2 982 119WATTS 120/1 13 5-6AIRKING <br />AK110LS6 STAFF RR 010 <br />CEILING SECOND FLOOR SIDE CENTRIFUGAL DIRECT 108 0.2 982 119WATTS 120/1 13 5-6AIRKING <br />AK110LS6 RESTROOM 2T2 <br />CEILING SECOND FLOOR SIDE CENTRIFUGAL DIRECT 108 0.2 982 119WATTS 120/1 13 5-6AIRKING <br />AK110LS6 RESTROOM 2T3 <br />CEILING SECOND FLOOR SIDE CENTRIFUGAL DIRECT 108 0.2 982 119WATTS 120/1 13 5-6AIRKING <br />AK110LS6 RESTROOM 2T1 <br /> 6. PROVIDE WITH ROOF CAP <br />ROOF FIRST FLOOR DOWNBLAST CENTRIFUGAL DIRECT 1600 0.75 1459 1/2 120/1 60 1-5GREENHECK <br />G-130-VG RESTROOMS <br />ROOF FIRST FLOOR DOWNBLAST CENTRIFUGAL DIRECT 600 0.75 1430 1/4 120/1 50 1-5GREENHECK <br />G-099-VG RESTROOMS <br />TAG <br />MFR & <br />MODEL LOCATION <br />AREA <br />SERVED DISCH TYPE DRIVE <br />AIR <br />FLOW <br />(CFM) <br />SP <br />(IN.WG.) <br />FAN <br />RPM <br />ELECTRICAL <br />HP V/PH <br />OPER. <br />WT. <br />(LBS) <br />NOTES <br />ROOF VENTILATION SIDE CENTRIFUGAL DIRECT 1440 1.0 1729 1.0 208/1 326 1-5CAPTIVE AIRE <br />A1-15D <br /> NOTES <br /> 1. STARTER AND FUSED DISCONNECT PROVIDED BY ELECTRICAL CONTRACTOR. <br /> 2. PROVIDE NON-OVERLOADING MOTOR. <br /> 3. PROVIDE ECM MOTOR AND MANUAL 0-10 VDC SPEED CONTROL. <br /> 4. PROVIDE BACKDRAFT DAMPER, FACTORY ROOF CURB. <br /> 5. SUPPLY FAN CONNECTS TO DDC FOR TIMECLOCK CONTROL. <br />FILTER <br />MERV <br />13 <br />CEILING SECOND FLOOR SIDE CENTRIFUGAL DIRECT 129 0.2 845 37WATTS 120/1 15 6-7AIRKING <br />AK150LS ELECTRICAL ROOM 218 <br /> 7. EXHAUST FAN SHALL OPERATE CONTINOUSLY. <br />ELECTRICAL <br />FLA <br />59.1 <br />MCA <br />62.8 <br />MOP <br />6.6 8.3 <br />70.0 <br />12.0 <br />I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />M0.1 <br />MECHANICAL <br />EQUIPMENT <br />SCHEDULES <br />DIFFUSER AND GRILLS SCHEDULE <br />TYPE TAG MANUFACTURER MODEL CFM QTY FACE SIZE NECK SIZE LEVEL REMARKS <br />CD 1 TITUS OMNI 100 5 24" X 24" 8" BASEMENT <br />CD 1 TITUS OMNI 140 1 24" X 24" 8" BASEMENT <br />CD 1 TITUS OMNI 160 2 24" X 24" 8" BASEMENT <br />CD 1 TITUS OMNI 180 2 24" X 24" 8" BASEMENT <br />CD 2 TITUS OMNI 180 12 24" X 24" 10" BASEMENT <br />CD 2 TITUS OMNI 240 9 24" X 24" 10" BASEMENT <br />EG 1 TITUS 350RL --- 1 12"X12" ---- BASEMENT <br />RG 1 TITUS PXP ---- 20 24"X24" ---- BASEMENT <br />RG 2 TITUS 350RL 1100 1 30"X12" ---- BASEMENT <br />SD 4 TITUS 300RL 300 1 18"X6" ---- BASEMENT <br />SD 5 TITUS 300RL 180 4 10"X6" ---- BASEMENT <br />SD 6 TITUS 300RL 300 4 18"X10" ---- BASEMENT <br />CD 1 TITUS MCD 200 6 24" X 24" 8"X8" FIRST FLOOR <br />CD 1 TITUS MCD 210 2 24" X 24" 8"X8" FIRST FLOOR <br />CD 1 TITUS MCD 230 6 24" X 24" 8"X8" FIRST FLOOR <br />CD 3 TITUS MCD 155 2 24" X 24" 8"X8" FIRST FLOOR <br />CD 3 TITUS MCD 200 10 24" X 24" 8"X8" FIRST FLOOR <br />CD 4 TITUS MCD 110 4 24" X 24" 6"X6" FIRST FLOOR <br />CD 5 TITUS MCD 350 4 24" X 24" 10"X10" FIRST FLOOR <br />CD 6 TITUS MCD 400 6 24" X 24" 12"X12" FIRST FLOOR <br />CD 7 TITUS MCD 50 2 12"X12" 6"X6" FIRST FLOOR <br />CD 8 TITUS 300RL 160 4 10"X10" ---- FIRST FLOOR <br />EG 1 TITUS 350RL 250 2 18"X18" ---- FIRST FLOOR <br />EG 1 TITUS 350RL 300 4 18"X18" ---- FIRST FLOOR <br />EG 2 TITUS 350RL 100 5 8"X8" ---- FIRST FLOOR <br />RG 1 TITUS PXP ---- 10 24"X24" ---- FIRST FLOOR <br />SD 1 TITUS 300RL 1000 4 36"X10" ---- FIRST FLOOR <br />SD 2 TITUS 300RL 1500 1 58"X10" ---- FIRST FLOOR <br />SD 3 TITUS 300RL 2000 5 58"X10" ---- FIRST FLOOR <br />TG 1 TITUS 300RL 300 2 12"X8" ---- FIRST FLOOR <br />TG 2 TITUS 300RL 600 1 18"X10" ---- FIRST FLOOR <br />CD 3 TITUS MCD --- 2 24" X 24" 8"X8" SECOND FLOOR <br />CD 3 TITUS MCD 150 5 24" X 24" 8"X8" SECOND FLOOR <br />CD 3 TITUS MCD 200 17 24" X 24" 8"X8" SECOND FLOOR <br />CD 5 TITUS MCD 250 2 24" X 24" 10"X10" SECOND FLOOR <br />CD 5 TITUS MCD 300 3 24" X 24" 10"X10" SECOND FLOOR <br />CD 5 TITUS MCD 350 2 24" X 24" 10"X10" SECOND FLOOR <br />CD 6 TITUS MCD 400 9 24" X 24" 12"X12" SECOND FLOOR <br />CD 6 TITUS MCD 600 1 24" X 24" 12"X12" SECOND FLOOR <br />CD 9 TITUS TMR 1000 3 ---- 18" Dia. SECOND FLOOR <br />RG 1 TITUS PXP ---- 30 24"X24" ---- SECOND FLOOR <br />RG 2 TITUS PXP ---- 2 48"X24" ---- SECOND FLOOR <br />REV # DESCRIPTION DATE <br />#020 ASI 03.21.2025 <br />#251 RFI 09.23.2025 <br />#251 <br />RFI
The URL can be used to link to this page
Your browser does not support the video tag.