Laserfiche WebLink
2SANITARY AND VENT RISER DIAGRAM - EAST EXIT <br />1SANITARY AND VENT RISER DIAGRAM - SOUTH EXIT <br />SCALE: NOT TO SCALE <br />SCALE: NOT TO SCALE <br />HPWH <br />1 <br />SE <br />1 <br />SE <br />2 <br />A <br />P3.0-2 <br />A <br />P3.0-2 <br />BASEMENT BASEMENT <br />FIRST FLOOR <br />SECOND FLOOR <br />CEILING <br />FIRST FLOOR <br />SECOND FLOOR <br />CEILING <br />LV-3 <br />(3 DFU) <br />LV-2 <br />(2 DFU) <br />(E)MS-1 <br />(3 DFU) <br />WC-1 <br />(4 DFU) <br />WC-1 <br />(4 DFU) <br />DF-1 <br />(1 DFU) <br />KS-1 <br />(2 DFU) <br />BASEMENT BASEMENT <br />FIRST FLOOR <br />SECOND FLOOR <br />CEILING <br />FIRST FLOOR <br />SECOND FLOOR <br />CEILING <br />4"W (8) 4"W (12) 4"W (13) <br />2"W (2)2"W (2)LV-1 <br />(1 DFU) <br />WC-1 <br />(4 DFU) <br />2"W (2) <br />LV-1 <br />(1 DFU) <br />WC-6 <br />(4 DFU) <br />4"W (6) <br />WC-3 <br />(4 DFU) <br />WC-3 <br />(4 DFU) <br />WC-4 <br />(4 DFU) <br />WC-4 <br />(4 DFU) <br />WC-5 <br />(4 DFU) <br />UR-3 <br />(2 DFU) <br />UR-2 <br />(2 DFU) <br />UR-2 <br />(2 DFU)WC-1 <br />(4 DFU) <br />2"W (5)2"W (7)2"W (9)4"W (13)4"W (21)4"W (25)4"W (52)2"W (3)2"W (3)4"W (55)4"W (58) <br />2"W (0)4"W (4)2"W (0)4"W (58)4"W (62)4"W (75) <br />BASEMENT <br />2"FD-1 <br />(0 DFU) <br />4"W (9) <br />ROOFROOF <br />3"VROOFROOF <br />2"V (0) 2"V (1) 2"V (9) 2"V (10) 2"V (11) <br />2"V (4) <br />2"V (3)4"V (73)2"V (9)2"V (0)2"V (0) <br />(E)4"VTR <br />(73) <br />NEW 2"VTR <br />(2)1-1/4"V(E)FS <br />(0 DFU)2"V2"V2"V2"V2"V2"V2"V2"V2"V2"V2"V (2)2"V 2"V2"V2"HD-1 <br />(0 DFU)2"V2"V1-1/4"V1-1/4"V3"MS-1 <br />(3 DFU) <br />3"W <br />3"W (3)2"V2"W 2"V2"FD-1 <br />(0 DFU) <br />2"W (1) <br />2"W <br />2"W (1)WC-4 <br />(4 DFU) <br />WC-4 <br />(4 DFU) <br />4"W (21)2"V4"W (13) <br />WC-6 <br />(4 DFU)2"V2"FD-1 <br />(0 DFU) <br />2"W <br />WC-7 <br />(4 DFU)2"V4"W (4) 4"W (4)2"W (3)4"W (13)LV-2 <br />(2 DFU)2"V2"W2"W (2) 2"W (3)4"W (11)2"V4"W (7) <br />KS-2 <br />(2 DFU)2"V2"FD-1 <br />(0 DFU) <br />WC-6 <br />(4 DFU)2"V2"W <br />4"W (4) 4"W (4) <br />UR-1 <br />(2 DFU) <br />LV-1 <br />(1 DFU)2"V2"W (3) 2"W (1)4"W (7)4"W (7)(E)4"W (0) <br />2"W (2) <br />(E)4"W <br />(E)FD <br />(0 DFU) <br />(E)4"W <br />(E)FD <br />(0 DFU) <br />(E)4"W (0) <br />2"W <br />2"W (0) <br />2"W <br />2"FS-1 <br />(CONDENSATE) <br />(0 DFU) <br />2"W (0) <br />WCO <br />2"FS-1 <br />(CONDENSATE) <br />(0 DFU)2"V2"V2"V (0) 2"V (0)2"V2"V4"W (30) 4"W (32) <br />2"V(2) 3"V(13) 3"V(5) 3"V(4) 3"V(3) <br />2"V (4) <br />3"V(15) <br />2"V (0) 2"V (6) 2"V (7) 2"V (9) 3"V(24)3"V(15)3"V(15)2"V3"V(28) 3"V(32) 2"V(2) <br />S-1 <br />(2 DFU) <br />DF-1 <br />(1 DFU)1-1/4"VS-1 <br />(2 DFU)2"V2"W(3) 2"W(2) <br />2"V(2)2"V(3)2"FORCE PIPING2"FORCE PIPING4"W <br />2"W (0)2"V2"W2"V(2) 2"V(2) <br />3"VTR <br />(37 DFU)3"V(34)3"V(34)3"V(37)(E)4"W (35) (E)4"W (37) <br />1/4" PER 1'-0' <br />SLOPE <br />1/4" PER 1'-0' <br />SLOPE 1/4" PER 1'-0' <br />SLOPE <br />1/4" PER 1'-0' <br />SLOPE <br />1/4" PER 1'-0' <br />SLOPE <br />1/4" PER 1'-0' <br />SLOPE <br />TO EXISTING <br />SEWER MAIN <br />TO EXISTING <br />SEWER MAIN <br />DF-1 <br />(1 DFU)2"V (1)2"W (1)2"V (0)2"V (1) <br />3"V (33) 3"V (25) 2"V (21) 2"V (13) 2"V (9) 2"V (7) 2"V (5) 2"V (3)2"V (7)2"V (3)2"V (2)2"V (2)WC-1 <br />(4 DFU)2"VWC-2 <br />(4 DFU)2"V4"W (29)4"W (33) <br />WC-6 <br />(4 DFU) <br />4"W (9)2"W (1) <br />LV-1 <br />(1 DFU)1-1/4"V2"W (1) <br />2"V (3)3"V (29) <br />3"V (40) <br />2"V (3) <br />2"V (4) <br />2"V (11) <br />2"V (4) <br />2"V (1)2"V (2) <br />LV-1 <br />(1 DFU) <br />2"W (1)2"VLV-1 <br />(1 DFU)2"V2"V (8) <br />2"W (3) 2"W (4)2"W (1)2"V (4) <br />2"V (11)4"W (15)2"W (3) <br />2"V (9)2"V (1)3"V (58) 3"V (64) <br />LV-1 <br />(1 DFU)1-1/4"V2"W (1)LV-1 <br />(1 DFU) <br />2"W (1)2"FORCE PIPING2"FORCE PIPINGBACKWATER <br />VALVE <br />2"FD-1 <br />(0 DFU) <br />2"W 2"V2"W <br />2"FD-1 <br />(0 DFU) <br />2"V (9) <br />4"W (9) <br />2"FD-1 <br />(0 DFU) <br />2"W 2"V2"W (1) <br />2"V (2) <br />2"FD-1 <br />(0 DFU)2"W 2"V2"W <br />2"FD-1 <br />(0 DFU) <br />2"V (10)2"W (0)I <br />U <br />E <br />I <br />H <br />U <br />9 <br />AS.O <br />A <br />FRANCN <br />4 0 8 0 <br />H <br />I <br />N <br />S <br />L11 <br />AL <br />E <br />CR <br />NDEN VA <br />,N I N G <br />CRAE <br />TCEI T <br />SC <br />S <br />N <br />N <br />G R O U P <br />7 <br />S <br />5 06 <br />C <br />07 18 <br />2 <br />P <br />R <br />A <br />O <br />90 <br />A <br />EU <br />C <br />+ <br />ER <br />4 <br />SHEET TITLE AND NO. <br />ISSUE DATE <br />PROJECT: <br />CA REG. <br />Project Arch.---- <br />---- <br />22575-01 <br />26 CIVIC CENTER <br />PLAZA <br />SANTA ANA <br />CA 92701 <br />SANTA ANA <br />LIBRARY <br />RENOVATION <br />CITY OF SANTA ANA <br />26 CIVIC CENTER PLAZA <br />SANTA ANA, CA 92701 <br />ELECTRICAL-PLMUMBING-MECHANICAL <br />1920 MAIN STREET, SUITE 820 <br />IRVINE, CA92614 <br />TEL: 949.516.6480 <br />BID SET <br />FINAL PERMIT/CONFORM <br />SET <br />04/30/2024 <br />08/02/2024 <br />P3.0-2 <br />SANITARY AND <br />VENT RISER <br />DIAGRAM <br />096 <br />RFI <br />096 <br />RFI <br />096 <br />RFI <br />REV # DESCRIPTION DATE <br />#020 ASI 03.21.2025 <br />096 RFI 03.27.2025 <br />25 ASI 07.31.2025 <br />25 <br />ASI <br />25 <br />ASI <br />25 <br />ASI