Laserfiche WebLink
SYMBOLMANUFACTURER/MODEL/DESCRIPTIONARCPSIGPMRADIUSRAIN BIRD RD-06-S-P30-F-U 08 HE-VTURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEMPRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE,AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALETHREADED INLET.ADJ30≤ 1.198'RAIN BIRD RD-06-S-P30-F-U 12 HE-VTURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEMPRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE,AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALETHREADED INLET.ADJ30≤ 2.3812'RAIN BIRD RD-06-S-P30-F-U 15 HE-VTURF SPRAY, 6IN. POP-UP, WITH 30 PSI IN-STEMPRESSURE REGULATION, SEAL-A-MATIC CHECK VALVE,AND FLOW-SHIELD TECHNOLOGY. 1/2IN. NPT FEMALETHREADED INLET.ADJ30≤ 3.7115'RAIN BIRD 1806-1400 FLOOD 1401FLOOD BUBBLER 6.0IN. POPUP360200.253'SYMBOLMANUFACTURER/MODEL/DESCRIPTIONPIPE TRANSITION POINTPIPE TRANSITION POINT FROM PVC LATERAL TO DRIPTUBING WITH RISER TO ABOVE GRADE INSTALLATION.RAIN BIRD MDCFCAPDRIPLINE FLUSH VALVE CAP IN COMPRESSION FITTINGCOUPLER.RAIN BIRD ARV0501/2IN. AIR RELIEF VALVE WITH A 6IN. DRIP VALVE BOX (SEB7XB EMITTER BOX). USE WITH INSTALLATION BELOW SOIL.HUNTER SD-B-STKMICRO SPRAY FOR RESIDENTIAL/COMMERCIAL USE. EIGHTSTREAMS OF WATER, WITH 360 DEGREE SPRAY. 15PSI TO30PSI. SOLO-DRIP WITH BARB AND 6IN. STAKE.AREA TO RECEIVE DRIPLINERAIN BIRD XFS-04-18XFS SUB-SURFACE PRESSURE COMPENSATING DRIPLINEW/COPPER SHIELD TECHNOLOGY. 0.4 GPH EMITTERS AT18" O.C. LATERALS SPACED AT 18" APART, WITH EMITTERSOFFSET FOR TRIANGULAR PATTERN. UV RESISTANT.SPECIFY XF INSERT FITTINGS.SYMBOLMANUFACTURER/MODEL/DESCRIPTIONRAIN BIRD EFB-CP1IN. BRASS REMOTE CONTROL VALVE, THAT ISCONTAMINATION PROOF W/SELF-FLUSHING FILTERSCREEN. GLOBE CONFIGURATION,RAIN BIRD EFB-CP-PRS-D1IN. BRASS REMOTE CONTROL VALVE, THAT ISCONTAMINATION PROOF W/SELF-FLUSHING FILTERSCREEN. GLOBE CONFIGURATION. USE NIBCO T-113-KGATE VALVE BEFORE VALVE. ADD RAIN BIRD PRF-100-RBYFILTER WITH VALVE.HUNTER HQ-5LRCQUICK COUPLER VALVE, YELLOW LOCKING RUBBERCOVER, RED BRASS AND STAINLESS STEEL, WITH 1IN. NPTINLET, 1-PIECE BODY.NIBCO T-113-KCLASS 125 BRONZE GATE SHUT OFF VALVE WITH CROSSHANDLE, SAME SIZE AS MAINLINE PIPE DIAMETER ATVALVE LOCATION.GRISWOLD 2160 1-1/2"1IN.-8IN. SOLENOID, NORMALLY OPEN MASTER VALVE.CAST IRON AND BRONZE MATERIAL. NPT ENDCONNECTION.FEBCO LF850-U-S 2"REDUCED PRESSURE BACKFLOW ASSEMBLYCALSENSE CS3000-32-S/CS3-GR-KIT/TP-110CS3000 SERIES 32 STATION AUTOMATIC CONTROLLERWITH STAINLESS STEEL TOP-ENTRY PEDESTALENCLOSURE AND 4G LTE CELLULAR MODEM WITHANTENNA. FLOW METER TO BE INSTALLED, SEE SEPARATECALLOUT. CONTRACTOR TO CONTACT CITY PUBLICWORKS PRIOR TO PURCHASING TO VERIFYCOMMUNICATIONS OPTIONS, EXISTING CALSENSECELLULAR DATA PLAN, AND EXISTING INTEGRATION WITHPLAYGROUND.CALSENSE REP: DAVID MEEHAN (760) 580-1829CALSENSE FM-1.5B1.5" BRONZE FLOW METER IN 1" BRASS TEE. WIRECONTROLLER USING #14 AWG WIRE IN 1" CONDUIT,INSTALL PER MANUFACTURERS RECOMMENDATIONS.MULTIPLE FLOW SENSORS REQUIRE SEPARATE CONDUITRUNS.STRONG BOX SBBC-45CRLOW PROFILE, TUBE AND WIRE CONSTRUCTION SMOOTHTOUCH SURFACE, COLD ROLLED STEEL, BACKFLOWENCLOSURE. 46.5IN.L, 28IN.H, 17.75IN.W.CALSENSE RB-1 TIPPING BUCKET RAIN SENSORMOUNT TO BUILDING UNDER CITY AND HISTORICALARCHITECT REVIEW. WIRED PER MANUFACTURERSINSTRUCTIONSWATER METER 2"DOMESTIC WATER. SEE POINT OF CONNECTION NOTES.IRRIGATION LATERAL LINE: PVC SCHEDULE 40SEE PIPE SIZING CHARTIRRIGATION MAINLINE: PVC CLASS 315 SDR 13.5PIPE SLEEVE: PVC SCHEDULE 4082151NO SYMBOL360MVBFAFSBERSMZZZZZZZZZZZZZZZZZZZZCIVIC CENTER DRIVEROSS STREET <br />LIMIT OF WORKLIMIT OF WORKSANTA ANA LIBRARYLIMIT OF WORKLIMIT OF WORKPARKING STRUCTURELIMIT OF WORKKID'S AREAN.A.P.TREVCAPABLEPARKINGSTALLEVCAPABLEPARKINGSTALLEVCAPABLEPARKINGSTALLEVCAPABLEPARKINGSTALLTREXISTINGTOREMAINTRA6.66A-41"DriplineZONE10.5A-51"DriplineZONE6.16A-31"DriplineZONE21212151512121212121515121212121212121215151515151212151515134"34"1"1"34"34"34"114"34"34"1"34"1"34"34"6A-61"BubblerZONE1.91A-71"DriplineZONE16.9A-81"DriplineZONEA-920.51"Turf SprayZONEA-109.21"Turf SprayZONE10.4A-111"Turf SprayZONE20.7A-121"Turf SprayZONEA-1310.71"DriplineZONEA-143.51"BubblerZONEBE1"1"A-17.081"DriplineZONEA-221"BubblerZONE34"515121212121212121212121518888834"34"34"34"MBFFSMV34"RS114"1"114"1"114"114"1"34"114"114"34"34"2"2"#"###VALVE CALLOUTVALVE NUMBERVALVE FLOWHYDROZONEVALVE SIZEIUEIHU9AS.OAFRANCN4080HINSL11ALECRNDENVA,NINGCRAETCEITSCSNNG R O U P7S506C07182PRAO90AEUC+ER4terra nINTEGRATIONLandscape Architecture CA#5231Planning + Design + Sustainability143 S. Olive St.Orange I CA I 92866714-724-981426 CIVIC CENTERPLAZASANTA ANACA 92701SANTA ANALIBRARYRENOVATIONCITY OF SANTA ANA26 CIVIC CENTER PLAZASANTA ANA, CA 92701IRRIGATIONPLANLA-3.01.POINT OF CONNECTION (POC) SHALL BE AT NEWLY PROVIDED 2" WATER METER AND SERVICE LINE. INSTALLNEW 2" BACKFLOW PREVENTOR, 1 1/2" MASTER VALVE, AND 1 1/2" FLOW METER AT LOCATION INDICATED ONCIVIC CENTER DRIVE. REFERENCE CIVIL ENGINEERING UTILITY PLANS FOR MORE INFORMATION2.CONTRACTOR SHALL CAP EXISTING IRRIGATION TO SITE AND ABANDON CURRENT OPERATING EQUIPMENT.NEW IRRIGATION SHALL BE INSTALLED PER PLAN.3.THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION AND WATER PRESSURE IN THE FIELD PRIOR TOSTARTING WORK. THE DYNAMIC WATER PRESSURE SHALL BE MEASURED AT THE MAXIMUM SYSTEM DEMANDAS INDICATED BELOW. IF ANY OF THE POC INFORMATION SHOWN ON THESE DRAWINGS IS FOUND TO BEDIFFERENT THAN THE ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THELANDSCAPE ARCHITECT,SHOULD THE CONTRACTOR FAIL TO VERIFY THE POC INFORMATION AS SHOWNHEREIN, ANY CHANGES REQUIRED BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OFTHE CONTRACTOR AT NO ADDITIONAL COST TO THE CITY/ OWNER.WATER PRESSURE AT METER60-65PSIDESIGN WATER PRESSURE30PSI4.CONTROLLER NOTE:4.1.THE CONTRACTOR SHALL REMOVE THE EXISTING IRRIGATION CONTROLLER, AND INSTALL NEW CALSENSECONTROLLER PER IRRIGATION LEGEND. RE-ESTABLISH CONNECTION TO EXISTING POWER SUPPLY.CONNECT & INTEGRATE EXISTING PLAYGROUND STATIONS INTO NEW CONTROLLER.1.CONTRACTOR TO INSTALL ALL IRRIGATION EQUIPMENT WITHIN LIMIT OF SITE WORK. SHOWN FOR CLARITYONLY - IRRIGATION IS SCHEMATIC.2.THE IRRIGATION PLAN IS DIAGRAMMATIC. CONTRACTOR CAN ROUTE PIPING IN A FREE FORM MANNER,AVOIDING OBJECTS LIKE LIGHT STANDARDS, TRANSFORMER PADS, EQUIPMENT VAULTS, SUB-SURFACEROCK TOO LARGE TO REMOVE, ETC.DRIPLINE NOTESLATERAL PIPE SIZINGFLOWPIPE SIZEFLOWPIPE SIZE0-8 GPM3/4"22.1-281 1/2"8.1-12 GPM1"28.1-452"12.1-22 GPM1 1/4"45.1+2 1/2"COMPLIANCE NOTEI HAVE COMPLIED WITH THE CRITERIA OF THE ORDINANCE AND APPLIED THEM FOR THEEFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLANS.3/17/2022LANDSCAPE ARCHITECTDATEPOINT OF CONNECTION NOTESIRRIGATION LEGENDINSTALL BUBBLERS ON OUTER EDGEOF MULCH LINE.SEE PLANTING PLAN FOR MULCH LINE.WIRE SLEEVE: PVC SCHEDULE 40.BURY MIN. 24" BELOW GRADE, EXTEND MIN. 12" BEYOND EDGE.NO SYMBOLNORTH010'20'40'SCALE: 1" = 20'-0"CONNECT NEW MAINLINE TOEXISTING MAINLINE SERVICINGCHILDREN'S PLAYGROUNDTHROUGH SHUT OFF VALVE.SHUT OFF VALVE TO BE LOCATED INEXISTING PLANTER AND TO RECEIVE3" LAYER OF BARK MULCH PERPLANTING PLANSCONTRACTOR TO REMOVE EXISTINGBACKFLOW, MASTER VALVE, ANDFLOW SENSOR ONLY.EXISTING CHILDREN'S PLAYGROUNDIRRIGATION TO BE INCORPORATEDINTO NEW OVERALL LIBRARYIRRIGATION SYSTEMREFER TO CIVIL PLANS PREPARED BYKPFF/ UTILITY PLAN SHEET C1-5.1 FORMORE INFORMATION AND COORDINATIONPRESSURE MAINLINE SHALL BE LOCATEDIN PLANTER IN A LOCATION FREE OFOBSTRUCTIONS AND MINIMUM OF 5'FROM TREE ROOTBALL. PLAN SHOWNFOR CLARITY PURPOSES ONLY.ASI#10.2ASI#10.2ASI#10.2ASI27.2