Laserfiche WebLink
TYP. <br />TYP. <br />TYP. <br />TYP.11 <br />2 <br />3 <br />TYP.2 TYP.2 <br />4 4 <br />Dr <br />. <br /> <br />K <br />a <br />l <br />a <br />n <br />t <br />a <br />r <br />i <br /> <br />D <br />e <br />n <br />t <br />a <br />l <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br /> <br />SHEET NO. <br />2509 <br />REVISIONS: <br />5/30/2025DATE: <br />PROJECT NO. <br />DE <br />N <br />T <br />A <br />L <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br /> <br />T <br />E <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br /> <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br />22 <br />2 <br />2 <br /> <br />S <br />. <br /> <br />B <br />r <br />i <br />s <br />t <br />o <br />l <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />A <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />ROOF PLAN <br />A-1.3 <br />N <br />1/4" = 1'-0" <br />ROOF PLAN <br />2.0 <br />A <br />GENERAL CONSTRUCTION NOTES: <br />1. DO NOT SCALE FROM PLANS. FIELD VERIFY ALL DIMENSIONS (ESPECIALLY EXISTING STRUCT POSTS) & REPORT ANY DISCREPANCIES TO <br />ARCHITECT AT ONCE. <br />2. ALL DIMENSIONS ARE TO CENTERLINE OF STUD OF WALLS UNLESS NOTED OTHERWISE. END DIMENSIONS ARE TO FINISHED INTERIOR FACE <br />OF EXISTING PERIMETER WALLS. <br />3. INSTALL DOUBLE STUDS AT JAMBS FOR ALL INTERIOR DOORS. <br />4. PROVIDE WATER RESISTANT GYPSUM BOARD AT WALLS W/ PLUMBING FIXTURES. <br />5. PROVIDE 5/8" GMMU (CEMENT BOARD) OVER 2-LAYER #15 FELT AT ALL WALLS SCHEDULED FOR TILED FINISH <br />6. REFER TO ENGINEER'S DRAWINGS FOR COORDINATION WITH MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS AS REQUIRED. <br />7. G.C. TO PROVIDE CONDUIT. OWNER TO SUPPLY AND INSTALL ALL TELEPHONE AND DATA JACKS AND WIRING. <br />GENERAL NOTESROOF PLAN KEYNOTES <br />1 EXISTING MECHANICAL PADS AND EQUIPMENT TO REMAIN-- NO WORK - TYP. <br />2.REMOVE EXISTING CLAY TILE SHINGLE ROOF AND PROVIDE NEW BLACK STANDING SEAM METAL ROOF - ESR-2048 W/ <br />CLASS A FIRE CLASSIFICATION <br />3.NEW PARAPET - SEE CAP DETAIL 2A6.3 <br />4. PROVIDE THROUGH-PARAPET DRAIN AT BOTTOM OF NEW PARAPET AT ROOF VALLEY - SEE ELEVATIONS <br />2 <br />A6.3 <br />4 <br />A6.3 <br />5 <br />A6.3 <br />A PLANCHECK <br />REVISIONS 10-15-25 <br />B PLANCHECK <br />REVISIONS 12-10-25