Laserfiche WebLink
BI <br />R <br />C <br />H <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />WARNER AVENUE <br />ALLEY <br />N. <br />A <br />. <br />P <br />. <br />N. <br />A <br />. <br />P <br />. <br />N.A.P.N.A.P. <br />CL <br />CL <br />CL <br />W W <br />ST <br />A <br />K <br />E <br /> <br />S <br />P <br />O <br />R <br />T <br />S <br /> <br />F <br />O <br />O <br />T <br />L <br />A <br />B <br />SHEET NUMBER <br />Know what's below. <br />before you dig.Call <br />40 <br />0 <br /> <br />W <br /> <br />W <br />A <br />R <br />N <br />E <br />R <br /> <br />A <br />V <br />E <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />92 <br />7 <br />0 <br />7 <br />LICENSED PROFESSIONAL ENGINEER <br />STATE OF CALIFORNIA <br />ERIC A. ROBLES <br />CIVIL <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />C <br />O <br />N <br />D <br />I <br />T <br />I <br />O <br />N <br />S <br />, <br /> <br />E <br />R <br />O <br />S <br />I <br />O <br />N <br />CO <br />N <br />T <br />R <br />O <br />L <br />, <br /> <br />A <br />N <br />D <br /> <br />D <br />E <br />M <br />O <br />L <br />I <br />T <br />I <br />O <br />N <br /> <br />P <br />L <br />A <br />N <br />DEMOLITION NOTES: <br />REMOVE EXISTING PARKING SIGNAGE AND STRIPING. <br />REMOVE PORTION OF EXISTING WALL. LIMITS PER GRADING SHEETS. <br />REMOVE EXISTING 8" BACKFLOW PREVENTION ASSEMBLY FROM VAULT; REMOVE <br />LID AND TOP PORTION OF VAULT TO MIN 24" BELOW GRADE, CORE ONE 4" <br />DIAMETER HOLE THROUGH BOTTOM OF VAULT AND BACKFILL VAULT WITH <br />CLEAN SAND (SE 30) AND COMPACT TO MIN 90% RELATIVE DENSITY PER <br />ASTM D1577. <br />REMOVE AND CLOSE DRIVEWAY PER STREET IMPROVEMENT PLANS (P0116060). <br />REMOVE PORTION OF EXISTING ASPHALT PAVEMENT. LIMITS PER GRADING <br />SHEETS. <br />REMOVE EXISTING STAIRS. <br />REMOVE EXISTING RAMP. <br />REMOVE AND REPLACE EXISTING PAVEMENT WITH LANDSCAPE. REFER TO <br />HORIZONTAL CONTROL AND GRADING PLANS FOR ADDITIONAL INFORMATION. <br />REMOVE AND REPLACE EXISTING SIGN PER SEPARATE PLANS. <br />REMOVE PORTION OF EXISTING V-GUTTER. LIMITS PER GRADING SHEETS. <br />REMOVE EXISTING TREES. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />EROSION CONTROL NOTES: <br />INSTALL AND MAINTAIN SAND BAGS PER CASQA BMP SE-8. <br />INSTALL AND MAINTAIN CONCRETE WASHDOWN AREA PER CASQA WM-8. <br />COORDINATE LOCATION IN FIELD. <br />CONSTRUCT TEMPORARY STABILIZED CONSTRUCTION ENTRANCE PER CASQA <br />TC-1, AT LIMITS OF WORK. <br />CONTRACTOR TO COORDINATE STOCKPILE LOCATION IN FIELD. CONTRACTOR <br />SHALL INSTALL AND MAINTAIN EROSION/MANAGEMENT CONTROL PER CASQA <br />WM-3. <br />INSTALL AND MAINTAIN MATERIAL DELIVERY AND STORAGE PER CASQA WM-1. <br />COORDINATE LOCATION IN FIELD. <br />STREET SWEEPING AS REQUIRED. CONDUCT PER CASQA SE-7. <br />INSTALL WASTE MANAGEMENT AREA PER CASQA WM-9. COORDINATE LOCATION <br />IN FIELD. <br />CONTRACTOR SHALL PROVIDE FENCING AS SHOWN AND/OR AS NEEDED TO <br />PROVIDE PEDESTRIAN PROTECTION PER CHAPTER 33 OF THE CBC. <br />INSTALL WASTE MANAGEMENT AREA PER CASQA WM-5. COORDINATE LOCATION <br />IN FIELD. <br />INSTALL AND MAINTAIN DRAIN INLET PROTECTION AT EXISTING AND <br />PROPOSED INLETS PER CASQA BMP SE-10. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />PROTECT IN PLACE NOTES: <br />PROTECT IN PLACE EXISTING WATER LINE. <br />PROTECT IN PLACE EXISTING WATER METER. <br />PROTECT IN PLACE EXISTING SANITARY SEWER LINE. <br />PROTECT IN PLACE EXISTING ELECTRICAL LINE. <br />PROTECT IN PLACE EXISTING GAS LINE. <br />PROTECT IN PLACE EXISTING STORM DRAIN. <br />PROTECT IN PLACE EXISTING TELEPHONE LINE. <br />PROTECT IN PLACE EXISTING V-GUTTER. <br />PROTECT IN PLACE EXISTING ASPHALT PAVEMENT. <br />PROTECT IN PLACE EXISTING BUILDING. <br />PROTECT IN PLACE EXISTING WALL. <br />PROTECT IN PLACE EXISTING CONCRETE DOCK. <br />PROTECT IN PLACE EXISTING RAMP. <br />PROTECT IN PLACE EXISTING STAIRS. <br />A <br />B <br />C <br />D <br />E <br />F <br />G <br />H <br />I <br />J <br />K <br />L <br />M <br />N <br />A <br />A <br />A <br />B <br />C <br />C <br />D <br />D <br />E <br />E <br />F <br />G <br />H <br />H <br />I <br />I <br />I <br />I <br />J <br />K <br />K <br />L <br />L <br />M <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />2 <br />2 <br />3 <br />4 <br />8 <br />8 <br />8 <br />5 <br />2 <br />6 <br />6 <br />7 <br />9 <br />1 <br />1 <br />1 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />6 <br />79 <br />8 <br />6 <br />N <br />8 <br />5 <br />5 <br />6 <br />N <br />9 <br />8 <br />8 <br />8 <br />LEGEND: <br />10 <br />10 <br />10 <br />11 <br />Behrooz Sarlak 2/26/2026