1. ALL DOORS AND WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE.
<br />2. ALL EXTERIOR DOORS & WINDOWS SHALL BE WEATHER TIED AND PROVIDE WITH INSECT
<br />SCREEN-METAL. DOORS & WINDOWS SHALL BE IN COMPLIANCE WITH ANSI. STD. A13 OR
<br />A1342.
<br />3. THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED
<br />BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE
<br />ENERGY CALCULATIONS.
<br />4. THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN
<br />ACCORDANCE WITH ASTM E1300.
<br />5. ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, LASER-
<br />ETCHED, OR EMBOSSED PER CRC 2406.3.
<br />6. GLAZING AND INSULATION SHALL CONFORM TO THE STATE ENERGY INSULATION STANDARD.
<br />7. DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE)
<br />8. GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR
<br />9. SLIDING GLASS DOORS AND WINDOWS LOCATED LESS THAN 16 FEET ABOVE ANY SURFACE
<br />AVAILABLE FOR USE BY THE PUBLIC SHALL BE CAPABLE OF BEING LOCKING SECURELY.
<br />MOVEABLE PANELS SHALL NOT BE EASILY REMOVED FROM THE FRAME.
<br />10. ALL MAIN OR FRONT ENTRY TO DWELLINGS SHALL BE ARRANGED SO THAT THE OCCUPANT HAS
<br />A VIEW OF THE AREA IMMEDIATELY OUTSIDE WITHOUT OPENING DOOR. SUCH VIEW MAY BE
<br />POVIDED BY A DOOR VIEW, A VIEW PORT, WINDOW, OR OTHER OPENING.
<br />11. ALL SWINGING DOORS SHALL BE EQUIPPED WITH A DEAD BOLT WITH A MINIMUM THROW OF 1
<br />INCH AND AN EMBEDMENT OF NOT LESS THAN 5/8 INCH.
<br />12. THE INACTIVE LEAF OF A PAIR OF DOORS AND THE UPPER LEAF OF DUTCH DOORS SHALL BE
<br />EQUIPPED WITH A DEAD BOLT.
<br />13. NON-REMOVABLE PINS SHALL BE USED IN PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM THE
<br />OUTSIDE WHEN THE DOOR IS CLOSED.
<br />14. UNFRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/2" THICK.
<br />15. NARROW-FRAMED GLASS DOORS SHALL BE FULLY TEMPERED GLASS NOT LESS THAN 1/4"
<br />THICK.
<br />16. ANY GLASS WHICH IS LOCATED WITHIN 40 INCHES OF THE BLOCKING DEVICE ON A DOOR SHALL
<br />BE FULLY TEMPERED, OR HAVE APPROVED METAL BARS, SCREENS OR GRILLS.
<br />17. IT IS CONTRACTOR'S RESPONSIBILITY TO CONFIRM DOOR/WINDOW ROUGH OPENING
<br />DIMENSIONS WITH THE MANUFACTURE/SUPPLIER PRIOR TO BEGIN CONSTRUCTION
<br />18. AUTOMATIC GARAGE DOOR OPENERS, IF PROVIDED, SHALL BE LISTED IN ACCORDANCE WITH UL
<br />325. (R309.4)
<br />19. WINDOW AREA OF HABITABLE ROOMS MUST BE AT LEAST 8% OF THE ROOM FLOOR AREA.
<br />(R303.10)
<br />20. OPENABLE WINDOWAREA OFHABITABLEROOMS MUST BE 4% OFTHEROOM FLOOR AREA. (CRC
<br />R303.1)
<br />21. EMERGENCY EGRESS:
<br />A. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET.
<br />B. MIN. SET CLEAR HEIGHT OF 24 INCHES AND 20 INCH WIDTH.
<br />C. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE
<br />THE FLOOR.
<br />1. STRING SHALL BE FABRICATED FROM EITHER HARD-DRAWN SPRING WIRE ( PER ASTM A227-21)
<br />OR OIL-TEMPERED WIRE ( PER ASTM A229-71)
<br />2. MINIMUM DESIGN STANDARD SHALL BE 9000 CYCLES.
<br />3. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED TESTING AGENCY.
<br />4. PHYSICAL CYCLING TESTS SHALL BE EQUIPPED WITH AN APPROVED DEVICE CAPABLE OF
<br />RESTRAINING THE SPRING OR ANY PART THERE OF IN THE EVENT IT BREAKS. CONTAINMENT DEVICE
<br />SHALL BE TESTED AND CERTIFIED BY AN APPROVED TESTING AGENCY.
<br />GARAGE DOOR STRINGS PER SEC. R309.5
<br />(1) DOOR SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WHEN MEASURED BETWEEN THE FACE OF
<br />THE DOOR AND THE STOP,WITH THE DOOR OPEN AT 90 DEGREE.
<br />(2) DOOR SHALL HAVE A MINIMUM CLEAR HEIGHT OF 78", MEASURED FROM THE TOP OF THE
<br />THRESHOLD TO THE BOTTOM OF THE STOP
<br />(3) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE USE OF A
<br />KEY OR SPECIAL KNOWLEDGE OR EFFORT.
<br />(4) SELF-CLOSING, TIGHT FITTING, SOLID WOOD, 1-3/8'' THICK DOOR, NOT LESS THAN 20-MIN
<br />FIRERATED DOOR AT OPENING TO DWELLING (CBC 715.4.3).
<br />(5) MIN. 72'' ABOVE FINISH FLOOR IN BATHROOMS.
<br />(6) THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED
<br />BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY
<br />CALCULATIONS.
<br />(7) THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN
<br />ACCORDANCE WITH ASTM E1300.
<br />(8) ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, ASER-
<br />ETCHED, OR EMBOSSED PER CRC 2406.3.
<br />(9) DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE
<br />(10) GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR
<br />DOOR/WINDOW REMARKS
<br />(1) SEAL AND PAINTED W/ A COAT FLAT VINYL.
<br />(2) UNDERCOAT AND FINISH W/SEMI-GLOSS ENAMEL.
<br />(3) KNOCKDOWN TEXTURE.
<br />(4) TAPED DRYWALL JOINTS.
<br />(5) SPRAYED SIMULATED ACOUSTIC PLASTER.
<br />(6) ORANGE PEEL FINISH.
<br />FINISH NOTES:
<br />1. GYPSUM BOARD SHALL NOT BE USED WHERE THERE WILL BE DIRECT EXPOSURE TO WATER, OR
<br />IN AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. CRC R702.3.7.1
<br />2. ALL DOORS & WINDOWS SHALL MEET CITY'S SECURITY ORDINANCE
<br />3. CONCRETE SLAB AND UNDER FLOOR INSPECTIONS SHALL BE MADE AFTER IN-SLAB OR UNDER-
<br />FLOOR REINFORCING STEEL AND BUILDING SERVICE EQUIPMENT, CONDUITS, PIPING OR OTHER
<br />ANCILLARY BUILDING TRADE PRODUCTS OR EQUIPMENT ARE INSTALLED, BUT BEFORE ANY
<br />CONCRETE IS PLACED OR FLOOR SHEATHING IS INSTALLED, INCLUDING THE SUBFLOOR
<br />R109.1.1.1
<br />4. ROUGH INSPECTION OF PLUMBING, MECHANICAL, GAS AND ELECTRICAL SYSTEMS SHALL BE
<br />MADE PRIOR TO COVERING OR CONCEALMENT, BEFORE FIXTURES OR APPLIANCES ARE SET OR
<br />INSTALLED, AND PRIOR TO FRAMING INSPECTION R109.1.2
<br />5. FIRE SPRINKLER PLANS STAMPED APPROVED BY THE CITY'S FIRE DEPARTMENT SHALL BE
<br />PROVIDED AT THE SITE AT TIME OF FRAMING INSPECTION.
<br />6. WATER PIPING MATERIAL WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC 604.1 OF
<br />THE CALIFORNIA PLUMBING CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEM
<br />SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF SEC 604 OF THE CPC,
<br />INSTALLATION STANDARDS OF APPENDIX 1 OF THE CPC AND MANUFACTURERS RECOMMENDED
<br />INSTALLATION STANDARDS. CPVC WATER PIPING REQUIRESA CERTIFICATION OF COMPLIANCE
<br />AS SPECIFIED IN SEC 604.4.1.1 OF THE CPC PRIOR TO PERMIT ISSUANCE.
<br />BUILDING DEPT. NOTES:
<br />NW4 4" WALL NEW WALL
<br />EW4 4" WALL EXISTING WALL
<br />WALL ID WALL THICKNESS REMARK
<br />DOOR / WINDOW NOTESDOOR SCHEDULE WINDOW SCHEDULE ROOM FINISH SCHEDULE
<br />WALL FINISH SCHEDULE
<br />ID QTY DOOR SIZE DESCRIPTION U-FACTOR SHGC REMARK
<br />E-1 1 3' - 0" x 6' - 8" EXTEIOR DOOR, SWING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED FINISH.
<br />E-2 5 2' - 6" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.
<br />E-3 1 16' - 4" x 7' - 10" DOOR GARAGE FLUSH PANEL
<br />E-4 1 5' - 2" x 6' - 8" FRENCH DOOR 2-PANEL SWING/GLASS, WOOD FRAME, PAINTED FINISH
<br />E-5 1 6' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.
<br />E-6 8 2' - 8" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.
<br />E-7 1 6' - 0" x 7' - 10" DOOR GARAGE FLUSH PANEL
<br />N-1 1 3' - 0" x 7' - 0" EXTEIOR DOOR, SWING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED FINISH. 0.5 95
<br />N-2 1 8' - 0" x 7' - 0" EXTEIOR DOOR, FOLDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH. 0.5 94
<br />N-3 2 7' - 0" x 7' - 0" EXTEIOR DOOR, FOLDING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH. 0.5 <varies>
<br />N-5 2 6' - 0" x 6' - 8" SLIDING DOOR, HOLLOW CORE, WOOD FRAME, TEMPERED GLASS, PAINTED FINISH <varies>
<br />N-6 3 2' - 4" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.<varies>
<br />N-7 1 2' - 6" x 6' - 8" POCKET DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.105
<br />N-8 1 2' - 4" x 7' - 0" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.97
<br />N-9 2 2' - 10" x 6' - 8" SWING DOOR, HOLLOW CORE, WOOD FRAME, PAINTED FINISH.<varies>
<br />N-10 1 2' - 10" x 6' - 8" POCKET DOOR, SOLID CORE, WOOD FRAME, PAINTED FINISH 107
<br />TOTAL: 32
<br />ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARK
<br />E-A 5 3' - 0" x 4' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.
<br />E-B 1 3' - 0" x 3' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.
<br />E-C 1 2' - 0" x 3' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.
<br />E-D 1 8' - 6" x 4' - 6" SLIDER, DUAL GLASS / VINYL FRAME, SOLID CORE, FINISH PER MFGR.
<br />N-A 2 6' - 0" x 3' - 6" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.0.3 0.23 <varies>
<br />N-B 1 2' - 6" x 4' - 0" SINGLE HUNG W/ FIX, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.0.3 0.23 130
<br />N-C 2 3' - 0" x 2' - 0" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.0.3 0.23 <varies>
<br />N-D 2 5' - 0" x 3' - 6" SLIDER, DUAL GLASS/ FIBERGLASS FRAME, SOLID CORE, FINISH PER MFGR.0.3 0.23 <varies>
<br />N-E 5 2' - 6" x 4' - 0" SKYLIGHT 0.3 0.23 <varies>
<br />TOTAL: 20
<br />RES-2025-1703-SCND
<br />JUL 05, 2025
<br />©2025Sheet No.
<br />Rev.
<br />Application No:
<br />Date
<br />Design by
<br />TRINH HA
<br />Date Rev.
<br />Pr
<br />o
<br />j
<br />e
<br />c
<br />t
<br />:
<br />1 12-17-2025 BLDG comments
<br />01-A-400
<br />PO
<br />I
<br />N
<br />S
<br />E
<br />T
<br />T
<br />I
<br />A
<br />
<br />S
<br />T
<br />
<br />R
<br />E
<br />S
<br />I
<br />D
<br />E
<br />N
<br />C
<br />E
<br />MA
<br />I
<br />N
<br />
<br />H
<br />O
<br />U
<br />S
<br />E
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />:
<br />
<br />2
<br />1
<br />0
<br />9
<br />
<br />N
<br />
<br />P
<br />o
<br />i
<br />n
<br />s
<br />e
<br />t
<br />t
<br />i
<br />a
<br />
<br />S
<br />t
<br />,
<br />
<br />S
<br />a
<br />n
<br />t
<br />a
<br />
<br />A
<br />n
<br />a
<br />,
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />6
<br />DE
<br />T
<br />A
<br />C
<br />H
<br />E
<br />D
<br />
<br />A
<br />D
<br />U
<br />
<br />A
<br />D
<br />D
<br />R
<br />E
<br />S
<br />S
<br />:
<br />
<br />2
<br />1
<br />1
<br />1
<br />
<br />N
<br />
<br />P
<br />o
<br />i
<br />n
<br />s
<br />e
<br />t
<br />t
<br />i
<br />a
<br />
<br />S
<br />t
<br />,
<br />
<br />S
<br />a
<br />n
<br />t
<br />a
<br />
<br />A
<br />na
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />2
<br />7
<br />0
<br />6
<br />DOOR & WINDOW
<br />SCHEDULE &
<br />INTERIOR DETAILS
|