Laserfiche WebLink
R <br />F.A.U <br />W/H <br />PEND <br />GD <br />J <br />W/D <br />El <br />e <br />c <br />. <br />REF <br />GD <br />RR <br />R <br />R <br />R <br />R <br />R <br />R <br />R R <br />R <br />R R <br />R <br />R R <br />R R <br />RR <br />R R <br />R R <br />PEND PEND <br />J <br />J <br />J <br />PEND <br />KITCHEN EXHAUST FAN MIN. 100 CFM <br />SHALL BE DUCTED TO THE OUTSIDE <br />L.E.D. RECESSED LIGHT FIXTURE <br />CEILING MOUNTED LINEAR BOX 1X4 LIGHT <br />FIXTURE <br />WALL AIR <br />DIFFUSER <br />GF <br />C <br />I <br />110V DUPLEX OUTLET, ARC FAULT <br />CIRCUIT INTERRUPTER (ENTIRE CIRCUIT) <br />AF <br />C <br />I <br />SWITCH W/ MOTION SENSOR (VACANCY <br />SENSOR) <br />VS <br />2-WAY SWITCH2D <br />HB <br />3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR <br />SMOKE DETECTOR HARDWIRED w/ <br />BATTERY BACK UP <br />SD <br />CARBON MONOXIDE DETECTOR <br />ALARM HARDWIRED w/ BATTERY <br />BACK UP <br />CDVANITY WALL LIGHT <br />EXTERIOR WALL SCONCE <br />LIGHT <br />ELECTRICAL PANEL <br />ATTIC FURNACE <br />NEW AC CONDENSER UNIT ON <br />PAD <br />ELECTRIC VEHICLE CHARGER <br />MEDIA OUTLET <br />CEILING AIR DIFFUSER <br />50 GAL HEATPUMP <br />INDOOR WATER HEATER <br />EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING <br />MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ <br />HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% <br />SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR <br />WALL <br />RESIDENCE IAQ FAN: 80 CFM <br />SEE T24 FOR SELECTION <br />110V DUPLEX OUTLET, GROUND FAULT CIRCUIT <br />INTERRUPT (ENTIRE CIRCUIT) <br />VS <br />CEILING MOUNTED HANGING LED LIGHT <br />FIXTURE (PENDANT) <br />GARBAGE DISPOSAL <br />PC : PHOTO CELL <br />W/P : WEATHER -RESISTANT <br />DIMMER SWITCH <br />D <br />J-BOX (CEILING FAN/LIGHT <br />FIXTURE) <br />LED LIGHTING <br />DRYER EXHAUST <br />PUSH BUTTON <br />T THERMOSTAT <br />P PHOTO CELL <br />M <br />BROADBAND/MEDIA CENTERB/B <br />E <br />110V DUPLEX OUTLET, COMBINATION <br />GROUND FAULT CIRCUIT INTERRUPT AND <br />ARC FAULT CIRCUIT INTERRUPTER (ENTIRE <br />CIRCUIT) <br />G/ <br />A <br />1. ELECTRICAL OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 210-52. <br />2. LIGHTING OUTLETS CONTROLLED BY A WALL SWITCH SHALL BE PROVIDED IN ACCORDANCE WITH NEC ARTICLE 210-70. <br />3. LIGHT FIXTURES INSTALLED IN CLOTHES CLOSET WILL COMPLY WITH NEC ARTICLE 410-8. <br />4. ELECTRICAL SERVICE SIZE: 200 AMPS, MIN. <br />5. ALL 120V SINGLE PHASE, 15 AND 20 AMP OUTLETS (RWCEPTACLE, LIGHTING, SMOKE DETECTORS, ETC.) SHALL BE PROTECTED BY <br />COMBINATION TYPE ARC-FAULT INTERRUPTER( CEC 210.12). <br />6. CONVENIENCE OUTLETS IN BATHROOMS, KITCHEN COUNTERTOPS, OUTDOORS, AND IN GARAGES AND BASEMENTS SHALL BE GFI <br />PROTECTED PER NEC ARICLE 210-8. <br />7. PROVIDE ACCESSIBLE JUNCTION BOX AND WRING FOR GROUNDING MAIN ELECTRICAL SERVICE TO REINFORCING BAR IN CONCRETE <br />FOOTING, PER ARTICLE 250.52-68 CEC 20' LONG #4 REBAR MIN. <br />8. ELECTRICAL OUTLET BOXES IN OPPOSITE FACES OF SEPARATION WALLS SHALL BE SEPARATED HORIZONTALLY BY 24". BACK AND <br />SIDES OF BOXES TO BE SEALED WITH 1/8" RESILIENT SEALANT AND BACKER WITH 2" MIN. MINERAL FIBER INSULATION. (TV, PHONE <br />AND INTERCOM OUTLETS MUST BE INSTALLED IN BOXES ACCORDINGLY) <br />9. RECESSED CAN LIGHT FIXTURES IN INSUTATED SPACES AER TO BE IC / AT RATED. <br />10. ELECTRIC UTILITY APPROVAL IS REQUIRED FOR METER LOCATION PRIOR TO INSTALLATION. <br />11. ELECTRICAL SERVICE TO BE UNDERGROUND FOR NEW CONSTRUCTION OF ADDITIONS > 50%. <br />12. FIELD INSPECTORS TO REVIEW AND APPROVE UNDERGROUND SERVICE REQUIREMENT PRIOR TO CONCRETE REPLACEMENT. <br />13. MAINTAIN THREE FEET CLEAR FROM FACE OF ELECTRICAL PANEL TO WALL ANY WALL SURFACE OR OBSTRUCTION. <br />14. SUBMIT SOUND ATTENUATION DESIGN FOR HVAC EQUIPMENT PER ARI STD.275. SOUND LEVEL NOT TO EXCEED 50 DBA (55 DBA <br />WITH TIMER, 65 DBA WITH TIMER AND NEIGHBOR"S CONSENT) PER SECTION 10.26.045 OF THE LOCATION OF MEASUREMENTS TO <br />BE AT FIVE (5) FEET ABOVE GRADE AT PROPERTY LINE. LOCATE EQUIPMENT IN EQUIPMENT WELL ON ROOF IF NECESSARY. <br />15. LAUNDRY AND BATHROOM EXHAUST FANS SHALL PROVIDE A MINIMUM OF 50 CFM. <br />16. PROVIDE COMBINATION SMOKE/ CARBON MONOXIDE DETECTORS IN EACH HALLWAY LEADING TO SLEEPING ROOMS, IN EACH <br />SLEEPING ROOM, AT THE TOP OF STAIRS, AND IN EACH STORY. SMOKE DETECTORS SHALL NOT BE LOCATED IN KITCHEN, GARAGE, <br />OR WITHIN 3 FEET OF DOORS TO KITCHEN OR BATHROOM OR SUPPLY AIR REGISTERS. DETECTORS HARD WIRED WITH BATTERY <br />BACK-UP. DETECTORS TO BE INTERCONNECTED TO SOUND AT THE SAME TIME. <br />17. ALL 125V,15A AND 20A RECEPTACLE OUTLETS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. <br />18. ANY FIXED APPLIANCE SUCH AS GARBAGE DISPOSER, DISHWASHER, CLOTHES WASHER, DRYER, BUILT-IN HEATERS, OR ANY <br />OTHER FIXED APPLIANCE WITH 1/4 HP MOTOR OR LARGER, SHALL BE ON A SEPARATE #12 AWG WIRE BRANCH 20 AMP CIRCUIT. <br />19. ALLPERMANENT INSTALLED LIGHTING, INCLUDING HALLWAYS, DINING ROOMS, BEDROOMS, FAMILY ROOMS, BEDROOMS, FAMILY <br />ROOMS, AND LIVING ROOMS MUST BE HIGH EFFICACY. <br />20. LIGHT FIXTURES IN BATHROOMS, GARAGES, LAUNDRY ROOM AND UTILITY ROOMS SHALL BE HIGH EFFICACY. AT LEAST ONE LUMINAIRE <br />IN EACH OF THESE SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. <br />21. RECESSED LIGHTS THAT ARE TO BE INSTALLED IN AN INSULATED CEILING OR CAVITY ARE REQUIRED TO HAVE A ZERO CLEARANCE <br />INSULATION COVER (IC): BE CERTIFIED THAT THEY ARE TIGHT; AND SEALED WITH A GASKET OR CAULK BETWEEN THE THE HOUSING AND <br />THE CEILING. <br />22. ALL STAIRWAY SHALL HAVE AN ILLUMINATION LEVEL ON TREAD RUNS OF NOT LESS HAN 1 FOOT CANDLE (11 LUX). <br />23. EXTERIOR LIGHTING MOUNTED ON BUILDING TO BE HIGH EFFICACY AND CONTROLLED BY MANUAL ON/OFF SWITCH MOTION SENSOR <br />WITHOUT OVERRIDE OR BYPASS SWITCH THAT DISABLES MOTION SENSOR AND: <br />A. PHOTO-CONTROL NOT HAVING AN OVERRIDE OR BYPASS SWITCH THAT DISABLES PHOTO-CONTROL <br />B. ASTRONOMICAL TIME CLOCK NOT HAVING OVERRIDE OR BYPASS SWITCH THAT DISABLES ASTRONOMICAL CLOCK <br />C. ENERGY MANAGEMENT CONTROL SYSTEM (EMC5) NOT HAVING OVERRIDE OR BYPASS SWITCH THAT ALLOWS LUMINAIRES TO BE <br />ALWAYS ON <br />D. RATED FOR WET LOCATIONS <br />24. PROVIDE WHOLE HOUSE MECHANICAL VENTILATION PER ASHRAE STANDARD 62.1-2007 SECT. 4, WITH EXCEPTION THAT NATURAL <br />VENTILATION THROUGH DOORS AND WINDOWS IS NOT AN ACCEPTABLE ALTERNATIVE TO WHOLE HOUSE VENTILATION (BEES 152(A), <br />EXCEPTION 5 TO SECTION, MINIMUM REQUIRED RATE OF VENTILATION OF 1 CFM FOR EACH 100SF. OF CONDITIONED FLOOR AREA PLUS <br />7.5 CFM FOR EACH OCCUPANT (1 OCCUPANT PER BEDROOM +1). VENTILATION TO BE PROVIDED BY EXHAUST AIR, SUPPLY AIR OF <br />COMBINES EXHAUST AND SUPPLY AIR. <br />25. PROVIDE GFCI RECEPTACLES AT BATHROOMS, KITCHEN COUNTERTOP SURFACES,LAUNDRY /WET BAR AREA WITHIN 6FT FROM EDGE <br />OF THE SINKS (CEC 210-8) <br />26. SERVICE EQUIPMENT AND SUBPANELS SHALL HAVE A MIN 30”WIDE BY 36”DEEP CLEAR WORKSPACE. (CEC 110.26) <br />27. PROVIDE A LISTED 1-INCH RACEWAY TO ACCOMMODATE A DEDICATED 208/240-VOLT CIRCUIT FOR FUTURE ELECTRICAL VEHICLE (EV) <br />CHARGER. (CAL GREEN 4.106.4.1) <br />28. ALL RECEPTACLE OUTLETS ARE REQUIRED SHALL BE LISTED TAMPER RESISTANT (CEC 406.12 AND 250.52) <br />29. COMBINATION TYPE AFCI CIRCUIT BREAKERS ARE REQUIRED FOR ALL 120-VOLT SINGLE PHASE 15/20-AMP BRANCH CIRCUITS. EXCEPT <br />FOR BATHROOMS, GARAGES, AND OUTDOORS. (CEC 210.12) <br />30. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE <br />THAN 48'' MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15'' MEASURED FROM THE BOTTOM OF THE OUTLET BOX <br />ABOVE THE FINISH FLOOR. <br />31. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR <br />LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. <br />32. ROOMS OR OCCUPIED SPACES WITHIN RESIDENTIAL OCCUPANCIES, WHERE THE OCCUPANTS AREA NONTRANSIENT, SHALL BE <br />DESIGNED TO HAVE MECHANICAL VETILATION AND EXHAUST AIR IN ACCORDANCE WITH SECTION 405 (CMC, 2022) <br />TYPICAL <br />WALL LIGHT SHALL <br />BE HIGH EFFICACY <br />(N <br />) <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />(N <br />) <br /> <br />C <br />A <br />B <br />I <br />N <br />E <br />T <br />SD <br />52 <br />55 <br />51 <br />P <br />P <br />P P <br />VS <br />VS <br />D <br />3D <br />D <br />2D <br />2D <br />D <br />G/ <br />A <br />+4 <br />8 <br />" <br />G/ <br />A <br />+4 <br />8 <br />" <br />G/ <br />A <br />+4 <br />8 <br />" <br />G/A <br />+48" <br />G/A <br />+48" <br />240V, READY <br />50A,G/A <br />GF <br />C <br />I <br />M <br />AFCI <br />WP <br />- <br />W <br />R <br />GF <br />C <br />I <br />, <br /> <br />2 <br />4 <br />0 <br />V <br />WP <br />- <br />W <br />R <br />GF <br />C <br />I <br />, <br /> <br />2 <br />4 <br />0 <br />V <br />24 <br />0 <br />V <br />, <br /> <br />R <br />E <br />A <br />D <br />Y <br />30 <br />A <br />, <br />G <br />F <br />C <br />I <br />, <br />W <br />P <br />- <br />W <br />R <br />WP-WR <br />GFCI, 240V <br />WP-WR <br />GFCI, 240V <br />3D <br />55 <br />PWP <br />- <br />W <br />R <br />GF <br />C <br />I <br />, <br /> <br />2 <br />4 <br />0 <br />V <br />P WP <br />- <br />W <br />R <br />GF <br />C <br />I <br />, <br /> <br />2 <br />4 <br />0 <br />V <br />240V, READY <br />30A,GFCI,WP-WR <br />P <br />WP-WR <br />GFCI, 240V <br />P <br />WP-WR <br />GFCI, 240V <br />D <br />D 3D <br />24 <br />0 <br />V <br />, <br /> <br />R <br />E <br />A <br />D <br />Y <br />30 <br />A <br />, <br />G <br />F <br />C <br />I <br />, <br />W <br />P <br />- <br />W <br />R <br />24 <br />0 <br />V <br />, <br /> <br />R <br />E <br />A <br />D <br />Y <br />30 <br />A <br />, <br />G <br />/ <br />A <br />G/A <br />+48" <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />SD <br />D <br />GF <br />C <br />I <br />VS <br />VS <br />AFCI <br />AFCIAF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />AF <br />C <br />I <br />AFCI <br />2D <br />2D <br />2D <br />2D <br />G/A <br />+48" <br />G/A <br />+48" <br />GFCI <br />D <br />D <br />D <br />D <br />D <br />GFCI <br />GFCI <br />CDSD <br />FAU <br />AFCI <br />39 <br />39 <br />39 39 <br />39 <br />39 <br />39 39 <br />54 <br />33 <br />30 <br />1.1 <br />1.2 <br />1.4 <br />1.5 <br />RES-2025-1703-SCND <br />JUL 05, 2025 <br />©2025Sheet No. <br />Rev. <br />Application No: <br />Date <br />Design by <br />TRINH HA <br />Date Rev. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />1 12-17-2025 BLDG comments <br />05-E-001 <br />PO <br />I <br />N <br />S <br />E <br />T <br />T <br />I <br />A <br /> <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />0 <br />9 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />1 <br />1 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />na <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />PROPOSED <br />CEILING <br />ELECTRICAL PLAN <br />ELECTRICAL NOTESELECTRICAL LEGEND ELEC. PLAN KEYNOTE <br />1.1 RELOCATED (E) ELECTRICAL METER FOR MAIN HOUSE, 200 AMP, <br />WITH 225 AMP BUS-RATING <br />1.2 (N) ELECTRICAL METER FOR DETACHED ADU, 200 AMP, WITH 225 <br />AMP BUS-RATING <br />1.4 (N) ELECTRICAL SUB PANEL DETACHED ADU, 200 AMP. WITH 225 <br />AMP BUS-RATING <br />1.5 (N) 60AMP SUBPANEL FOR ADU ESS SYSTEM <br />30 <br />(N) AC UNIT ON 3" THIK. CONCRETE PAD PER T-24. (SHALL BE <br />VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR <br />TO INSTALLATION) <br />33 (N) HEAT PUMP WATER HEATERS PER T-24 <br />39 PHOTOCELL CONTROL / MOTION SENSOR <br />51 <br />(N) 30" INDUCTION RANGE WITH OVEN. PROVIDE EXHAUST HOOD <br />WITH LIGHT AND FAN VENT TO OUTSIDE AIR (280 CFM) WITH 8" <br />DUCT. VERIFY DIMENSIONS AND POWER REQUIREMENTS WITH <br />MANUFACTURER'S SPECIFICATIONS. <br />52 <br />THIS SWITCH CONTROLS THE INDOOR AIR QUALITY VENTILATION <br />FOR THE HOME. LEAVE SWITCH IN THE 'ON' POSITION AT ALL <br />TIMES UNLESS THE OUTDOOR AIR QUALITY IS <br />VERYPOOR."[150.0(O)J] <br />54 <br />MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT <br />DAMPER. DUCT LENGTH OR SIZES AS PERMITTED OR REQUIRED <br />BY MANUFACTURERS INSTALLATIONS AND APPROVED BY THE <br />BUILDING OFFICIAL (EXHAUST THROUGH ROOF) SEE DETAIL ON <br />SHEET AD.1 <br />55 <br />EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR RATED. <br />CEILING MOUNTED LIGHT W/ VENT 50CFM MIN. INTERMITTENT <br />W/HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50-80% <br />SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL <br />1/4" = 1'-0"1ADU - ELECTRICAL PLAN