Laserfiche WebLink
2% <br />W CW CWCWCWCWCWCW <br />SS SSSSSSSSSSSSSSSSSSSSSS <br />SS SSSSSSSSSSSSSSSSSSSSSS <br />CWCWCWCW <br />CWCWCWCWCWCWCWCWCWCWCWCWCWCW <br />GAS GASGASGASGASGASGASGAS <br />GA <br />S <br />GA <br />S <br />G <br />GCW <br />CW <br />CW <br />CW <br />W <br />CW <br />CW <br />5%5% <br />5%5%2%2%2% <br />2%2%5%2%2%2% <br />5% <br />5% <br />2%2% <br />2% <br />2% <br />2% <br />5% <br />2% <br />2% <br />2%2% <br />G <br />CW CW <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />F. <br />S <br />. <br />L <br />GAS GASGASGASGASGAS <br />DRAINAGE DIRECTION AND SLOPE <br />PROPERTY LINE CORNER POINTS <br />AND ELEVATION DATUM <br />#KEYNOTE CALLOUTS <br />EXISTING WALL TO <br />REMAIN AND NEW WALL <br />WALL TO BE DEMOLISHEDFIRE SEPARATION IMAGINARY LINEF.S.L <br />FIRE SEPARATION DISTANCEF.S.D <br />EXISTING DRAINAGE DIRECTION AND SLOPE <br />JURISDICTION HAVING AUTHORITY:SANTA ANA, CA 92706 <br />LEGAL DESCRIPTION:N-TRACT 1335, LOT 63 <br />ASSESSORS PARCEL NO. APN:003-133-20 <br />IN FLOOD ZONE FEMA SHFA'S:TYPE X <br />CONSTRUCTION TYPE:V-B (NON-RATED) <br />ZONING:R1 <br />OCCUPANCY GROUP:R3/U <br />SPRINKLERS:NO (MAINHOUSE & ADU) <br />NUMBER OF STORIES ADU :1-STORY (ALLOWABLE: 18 FT) <br />REQUIRED SETBACKS <br />FRONT SETBACK 20 FT <br />SIDE SETBACK 5 FT <br />REAR SETBACK 20 FT <br />LOT SIZE: 7,755 SF <br />AREA: <br />EXISTING UNIT: <br />-(E) MAIN HOUSE:1220 SF <br />-(E) GARAGE: 380 SF <br />-(E) PORCH:81 SF <br />-(E) REAR PORCH:124 SF <br />NEW DETACHED ADU:749 SF <br />LOT COVERAGE: <br />=(1220+380+81+124+749)/7755*100%=32.93%(<35%) <br />THE ADU sf / SFD sf RATIO IS FOR PARK & AMP; REC FEE PURPOSE <br /> = (749 / 1220) * 100% = 61.4 % <br />LANDSCAPE FRONT YARD: <br />-(E) GRASS:815 SF <br />-(E) TOTAL FRONT YARD:1000 SF <br />-DRIVE WAY:185 SF <br />LANDSCAPE (%): 815/1000*100%=81% <br />1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS <br />SHALL BE PLACED APPROPRIATELY IN REFUSE BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, <br />RAIN, ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR TO BE LIABLE FOR <br />REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING <br />MATERIALS AND/OR STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY USE OF PLASTIC OR <br />WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED <br />TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE-WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE <br />AS-BUILT INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS REQUIRED. <br />2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOID WASTE, PETROLEUM <br />BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES <br />OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN <br />SYSTEM. <br />3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER <br />DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, <br />ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES <br />WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS <br />AND/OR ADDITIONAL EXPENSES. <br />4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION PROCEDURES SHALL BE VERIFIED AND APPROVED <br />BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. <br />5. NOTIFY AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO <br />DEMOLITION PERMIT ISSUANCE. <br />6. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZERD AT ALL TIMES. <br />7. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. <br />8. NEW BUILDING SHALL HAVE APPROVED ADDRESS NUMBERS (CRC R319.1) IN A POSITION THAT IS PLAINLY VISIBLE FROM THE <br />STREET FRONTING THE PROPERTY. NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE A <br />MINIMUM 4 INCHES HIGH AND 1/2 INCH STROKE WIDTH <br />-IF ILLUMINATED; COMPLY WITH CALIFORNIA ENERGY CODE SECTION 140.8; OR <br />-SIGN SHALL CONSUME NO MORE THAN 5 WATTS OF POWER AS DETERMINED ACCORDING TO SECTION 130.0(C). <br />9. CONCRETE SLAB AND UNDER-FLOOR INPECTIONSIN SHALL BE MADE ATERAFIN-SLAB O UNDER-FLOOR REINFORCING STEEL AND <br />BUILDINGSERVICE EQUIPMENT, CONDUCTS, PIPING OR ORTHE ANCILLARY BUILDING TRADE PRODUCTS OR EQUIPMENT ARE <br />INSTALLED, BUT BEFORE ANY CONCRETE IS PLACED OR FLOOR SHEATHING IS INSTALLED, INCLUDING THE SUBFLOOR. <br />(R109.1.1.1) <br />10. ROUGH INSPECTION OF PLUMBING, MECHANICAL GAS AND ELECTRICAL SYSTEMS SHALL BE MADE PRIOR TO COVERING OR <br />CONCEALMENT, BEFORE FIXTURES OR APPLIANCES ARE SET OR INSTALLED , AND PRIOR TO FRAMING INSPECTION. (R109.1.2) <br />11. WATER PIPING MATERIALS WITHIN A BUILDING SHALL BE IN ACCORDANCE WITH SEC. 604.1 OF THE CALIFORNIA PLUMBING <br />CODE. PEX, CPVC AND OTHER PLASTIC WATER PIPING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE <br />REQUIREMENTS OF SEC.604 OF THE CPC, INSTALLATION STANDARDS OF APPENDIX I OF THE CPC AND MANUFACTURERS <br />RECOMMENDED INSTALLTION STANDARDS. CPVC WATER PIPING REQUIRES A CERTIFICATION OF COMPLIANCE AS SPECIFIED IN <br />SEC 604.1.1 OF THE CPC PRIOR TO PERMIT ISSUANCE. <br />1. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND <br />UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES <br />(POWER POLES, PULL-BOXES, TRANSFORMERS, VAULTS, PUMPS,VALVES, <br />METERS, ETC) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL <br />NOT BE WITHIN TEN FEET OF ANY POWER LINES-WHETHER OR NOT THE LINES <br />ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE <br />CONSTRUCTION DELAYS AND/ OR ADDITIONAL EXPENSES. <br />2. AN APPROVED SEISMIC GAS SHUTOFF VALVE WILL BE INSTALLED ON THE FUEL <br />GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY <br />CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE <br />FUEL GAS PIPING. <br />3. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. <br />EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER <br />CONSUMPTION. <br />4. PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND <br />APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. <br />5. ALL CONSTRUCTION WASTE AND DEBRIS MUST BE CONTAINERIZED AT ALL TIMES <br />6. FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET <br />IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS <br />PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO DRIVEWAY, SEWER <br />LATERALS AND ANY WORK IN RIGHT OF WAY. <br />7. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND <br />LOCAL CODES AND AMENDMENTS. <br />8. A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES <br />WHICH DEFINE PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR <br />STREET RIGHT-OF-WAY. <br />9. DUST CONTROL MEASURES SHALL BE MAINTAINED THROUGHOUT THE DURATION <br />OF THE PROJECT. <br />10. WATER HEATER MUST BE STRAPPED TO WALL. SEE DETAIL ON SHEET A-03. <br />11. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING <br />SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR WATER CONSUMPTION. <br />12. LAG BOLTS: PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIA. AND FULL <br />DIA. FOR SMOOTH SHANK PORTION. 91 NDS <br />13. BLOCKING. ROOF RAFTERS AND CEILING JOINTS SHALL BE SUPPORTED <br />LATERALLY TO PREVENT ROTATION & LATERAL DISPLACEMENT IN ACCORDANCE <br />w/ THE PROVISIONS OF CH.8 & CH.6 <br />14. CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM <br />THAT THERE IS NO TRACEOF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM <br />PROPOSED PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, THEY NEED TO <br />SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO <br />BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. <br />15. SHEARWALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE <br />STANDARD LISTED IN CH.6 & CH.7 CRC <br />16. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. "ENGINEER" <br />MUST INCLUDE IN STRUCTURAL OBSERVATION NOTES. <br />17. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. <br />18. CONCRETE 3000PSI <br />19. PARALLEL BEAM E.2.0 PSL <br />20. UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. <br />21. UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, <br />CABLE TV. AND TELEPHONE <br />22. ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH <br />CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED <br />23. BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED <br />RECEPTACLE OUTLETS. <br />24. WATER SAVING WATER CLOSET w/1.28 GALLONS PER FLUSH. <br />25. PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS <br />WITHOUT OPENABLE WINDOW. <br />26. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC <br />OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC <br />27. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE <br />WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. <br />28. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A <br />NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE <br />AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM <br />AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. <br />29. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT <br />DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE <br />EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE <br />BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. <br />ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT <br />IS TO BE USED SHOULD BE VERIFIED WITH THE OWNER OR ENGINEER OF <br />RECORD. <br />30. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER <br />SCALE. <br />31. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE <br />OWNER AND THE DESIGNER/ENGINEERS SHALL BE NOTIFIED, IN WRITING, <br />IMMEDIATELY. <br />32. THE CALIFORNIA SWIMMING POOL SAFETY ACT (HEALTH & SAFETY CODE SECTION <br />115920) MANDATES THAT ALL DOORS PROVIDING DIRECT ACCESS FROM THE <br />RESIDENCE TO A NEW SWIMMING POOL AND/OR SPA IS PROVIDE WITH AN <br />APPROVED SAFETY COVER OR THE POOL AND/OR SPA IS ISOLATED FROM DIRECT <br />ACCESS TO THE HOME BY AN APPROVED POOL FENCE AND GATE ENCLOSURE. <br />33. BOTH ADU AND PRIMARY DWELLING ROOF MUST MATCH AND BE SUBSTANTIALLY <br />SIMILAR IN DESIGN, PITCH, COLOR, MATERIAL AND TEXTURE. <br />34. FINAL ELECTRICAL PANEL LOCATION WILL BE AS DETERMINED BY SCE AND <br />CITYINSPECTOR <br />35. STATES THAT ALL UTILITIES WILL BE UNDERGROUNDED PER SAMC 41-626. <br />17th-Santiago <br />Stop ID: 5926 <br />Bus stop <br />PROJECT LOCATIONTHE NEAREST PUBLIC <br />FIRE HYDRANT IS IN <br />FRONT OF THE PROJECT <br />LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92706 <br />THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS: <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 SANTA ANA ZONING AND SUBDIVISION ORDINANCE <br />REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE. CITY OF SANTA ANA MUNICIPAL CODE. <br />OWNER: <br />NAME: Neil Oscar Rosales and <br /> Kristi Lyn Lewis Rosales <br />Address: 2111 N Poinsettia St, Santa Ana, CA 92706 <br />PHONE: (714) 510 -1110 <br />EMAIL: trutone@mac.com <br /> luminancephoto@icloud.com <br />DESIGNER: <br />NAME: TRINH HA <br />16168 BEACH BLVD, STE#201C, <br />HUNTINGTON BEACH, CA 92647 <br />PHONE: 714-928-8006 <br />EMAIL: <br />ENGINEER OF RECORD: <br />NAME: TUNG VO <br />16168 BEACH BLVD, STE#201C, <br />HUNTINGTON BEACH, CA 92647 <br />PHONE: 714-928-8006 <br />EMAIL: TUNGCIVIL2018@GMAIL.COM <br />-TOTAL: PROVIDE 4 PARKING SPACE <br />8 <br />7 <br />F.S.D. <br />13'-6" <br />20 <br />F <br />T <br /> <br />R <br />E <br />Q <br />. <br /> <br />F <br />R <br />O <br />N <br />T <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br /> <br />( <br />N <br />O <br /> <br />C <br />H <br />A <br />N <br />G <br />E <br />) <br />STREET CURB <br />& GUTTER <br />(E) GARAGE <br />(E) MAINHOUSE -1 STORY <br />(LIVING AREA = 1220 SF) <br />2109 N POINSETTIA ST, <br />SANTA ANA, CA 92706 <br />(E <br />) <br /> <br />R <br />E <br />A <br />R <br /> <br />P <br />O <br />R <br />C <br />H <br />12 <br />4 <br /> <br />S <br />F <br />(E) PORCH <br />81 SF <br />2109 N POINSETTIA ST, <br />SANTA ANA, CA 92706 <br />(N) DETACHED ADU -1 STORY <br />(LIVING AREA = 749 SF) <br />PL <br /> <br />5 <br />0 <br />. <br />0 <br />0 <br />' <br />PL 155.10' <br />PL 155.10' <br />PL <br /> <br />5 <br />0 <br />. <br />0 <br />0 <br />' <br />5FT REQ. SIDE SETBACK <br />5FT REQ. SIDE SETBACK <br />20 <br />F <br />T <br /> <br />R <br />E <br />Q <br />. <br /> <br />R <br />E <br />A <br />R <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br />5F <br />T <br /> <br />R <br />E <br />Q <br />. <br /> <br />E <br />A <br />S <br />E <br />M <br />E <br />N <br />T <br />7' <br />- <br />6 <br />" <br />37 <br />' <br />- <br />6 <br />" <br />SIDE SETBACK <br />5'-0" <br />(E) FRONT SETBACK <br />29'-1" <br />(E) <br />19'-0" <br />(E) <br />46'-6" <br />REAR SETBACK <br />60'-6" <br />(E) FRONT SETBACK <br />29'-1" <br />(E) <br />18'-11" <br />(E) <br />13'-2" <br />(E) <br />4'-9" <br />(E) <br />23'-6" <br />(E) <br />5'-2" <br />REAR SETBACK <br />60'-6" <br />(E) SIDE SETBACK <br />5'-0" <br />(E) <br />14'-0" <br />(E) <br />6'-0" <br />(E) <br />20'-0" <br />(E) S. SB. <br />5'-0" <br />35.130.1 <br />27 <br />(E) <br />22'-7" <br />(E) <br />35'-1" <br />(E) <br />46'-1 1/2" <br />(E) <br />14'-11" <br />(E) <br />11'-1" <br />(E) SIDE SETBACK <br />5'-0" <br />(E) <br />24'-0" <br />(E) <br />12'-0" <br />(E) SIDE SETBACK <br />9'-0" <br />(E) <br />1'-6" <br />(E) <br />1'-6" <br />(E) <br />1'-6" <br />(E) <br />1'-6" <br />(E) <br />7'-8" <br />(E) <br />1'-6" <br />(E) <br />1'-6" <br />(E) <br />14'-8" <br />(E) <br />6'-8" <br />24 <br />24 <br />24 <br />24 24 <br />24 <br />24 <br />24 <br />6 <br />11 <br />11.15 <br />11 <br />8.1 <br />9 <br />13.1 <br />20.1 <br />20 <br />14 <br />14 <br />AR <br />E <br />A <br /> <br />I <br />N <br /> <br />2 <br />0 <br />F <br />T <br /> <br />S <br />E <br />T <br />B <br />A <br />C <br />K <br /> <br />4 <br />7 <br />3 <br /> <br />S <br />F <br />3'-9"5'-6" <br />CURB TO CENTER OF STREET <br />16'-0" <br />22 <br />95 <br />10 <br />01-A-301 <br />19 17 <br />17 <br />17 <br />7 <br />01-A-301 <br />7 <br />01-A-301 <br />96 <br />(2) UTILITY DROP <br />INSTALL UNDERGROUND <br />INSTALL UNDERGROUND ELECTRICAL <br />20'-0" <br />3 <br />1.5 <br />7.1 <br />2'-6" <br />9 <br />46'-7" <br />50'-0" <br />60'-6" <br />50'-0" <br />27'-0"27'-0" <br />CE <br />N <br />T <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br /> <br />O <br />F <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />PO <br />I <br />N <br />S <br />E <br />T <br />T <br />I <br />A <br /> <br />S <br />T <br />2 <br />2111 N POINSETTIA ST, <br />SANTA ANA, CA 92706 <br />F.S.D. <br />12'-0" <br />(E) <br />1'-6" <br />5 <br />01-A-3014.14 <br />16.1 <br />16.1 <br />16.1 <br />(N) PAVING CONCRETE AREA <br />14.1 <br />1 <br />1'-6" <br />1'-6" <br />30 <br />33 <br />9 <br />F.S.D. <br />12'-0" <br />F.S.D. <br />13'-6" <br />1'-6" <br />1'-6" <br />1'-6" <br />1.5 <br />1.4 <br />1.2 <br />1.1 <br />12'-0" <br />33'-8" <br />ADU REAR SB. <br />6'-6" <br />5'-0"1'-6" <br />ADU SIDE SB. <br />12'-4" <br />4'-10" <br />7'-6" <br />1'-0" <br />10'-8" <br />11'-8" <br />1'-0"15'-0" <br />23'-0" <br />ADU SIDE SB. <br />4'-0" <br />1'-6" <br />10'-0" <br />10'-0" <br />(E <br />) <br /> <br />D <br />R <br />I <br />V <br />E <br />W <br />A <br />Y <br /> <br />A <br />P <br />P <br />R <br />O <br />A <br />C <br />H <br />(E) <br />2'-0" <br />(E) <br />8'-0" <br />(E) <br />8'-0" <br />(E) <br />3'-0" <br />(E) <br />16'-0" <br />13 <br />(E) <br /> 8'-0" <br />42'-0 1/2" <br />1 <br />THIS PROPOSED PROJECT CONSISTS OF: <br />1. NEW DETACHED ADU: 749 SF <br /> (1) LIVING AREA, (1) KITCHEN, (2) BED, (2) BATHROOM <br />2. RELOCATION THE EXTERIOR WASHER AND DRYER AT (E) REAR PORCH <br /> INTO THE FOOTPRINT OF THE MAIN HOUSE <br />RES-2025-1703-SCND <br />JUL 05, 2025 <br />©2025Sheet No. <br />Rev. <br />Application No: <br />Date <br />Design by <br />TRINH HA <br />Date Rev. <br />Pr <br />o <br />j <br />e <br />c <br />t <br />: <br />1 12-17-2025 BLDG comments <br />01-A-000 <br />PO <br />I <br />N <br />S <br />E <br />T <br />T <br />I <br />A <br /> <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />MA <br />I <br />N <br /> <br />H <br />O <br />U <br />S <br />E <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />0 <br />9 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />: <br /> <br />2 <br />1 <br />1 <br />1 <br /> <br />N <br /> <br />P <br />o <br />i <br />n <br />s <br />e <br />t <br />t <br />i <br />a <br /> <br />S <br />t <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />na <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />PROJECT DATA / <br />SITE PLAN <br />1.1 RELOCATED (E) ELECTRICAL METER FOR MAIN HOUSE, 200 AMP, WITH 225 AMP <br />BUS-RATING <br />1.2 (N) ELECTRICAL METER FOR DETACHED ADU, 200 AMP, WITH 225 AMP BUS-RATING <br />1.4 (N) ELECTRICAL SUB PANEL DETACHED ADU, 200 AMP. WITH 225 AMP BUS-RATING <br />1.5 (N) 60AMP SUBPANEL FOR ADU ESS SYSTEM <br />2 (E) DROP ELECTRIC WIRE CONNECT TO ELECTRIC METER <br />3 (E) ELECTRICL POLE <br />4 (E) GAS METER <br />4.1 (N) GAS METER <br />5 (E) GAS SUPPLY LINE, 3/4" MIN. STAINLESS STEEL PIPE <br />6 CONNECTED TO EXISTING GAS BY GENERAL CONTRACTOR <br />7 (E) WATER METER <br />7.1 (N) WATER METER, LABEL SIZE OF NEW WATER METER - 1" MINIMUM PER CITY <br />REQUIREMENTS <br />8 (E) WATER SUPPLY LINE, 1" MIN. COPPER PIPE <br />8.1 (N) WATER SUPPLY LINE, 1" MIN. COPPER PIPE <br />9 WATER POINT OF CONNECTION <br />11 (E) SEWER LINE CONECTED TO EXISTING SYSTEM OF THE CITY <br />11.1 (N) SEWER LINE. (4'' MIN. DIA. SEWER LINE, FROM (N) DWELLING UNIT WITH MINIMUM 2% <br />SLOPE FRO DRAINAGE) <br />13 (E) DRIVEWAY PARKING <br />13.1 (N) DRIVEWAY PARKING <br />14 (E) WALKWAY / (E) CONCRETE YARD <br />14.1 (N) WALKWAY / (N) CONCRETE YARD <br />16.1 (N) LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN DEPTH. MIN. 2% SLOPE AWAY <br />FROM BUILDING. <br />17 (E) PERIMETER FENCE, 6FT HEIGHT BLOCK WALL <br />19 (E) WOOD GATE <br />20 (E) LANDSCAPE <br />20.1 (N) LANDSCAPE <br />22 (E) TREE <br />24 ROOF/ FLOOR LINE ABOVE <br />27 (E) CHIMNEY <br />30 (N) AC UNIT ON 3" THIK. CONCRETE PAD PER T-24. (SHALL BE VERIFIED AND APPROVED BY <br />THE BUILDING INSPECTOR PRIOR TO INSTALLATION) <br />30.1 (E) AC UNIT <br />33 (N) HEAT PUMP WATER HEATERS PER T-24 <br />35.1 (E) TANK WATER HEATERS <br />95 (N) 1HR FIRE RATED WALL W/ STC RATING OF 50, SEE SHEET AD.2 FOR DETAILS <br />96 1-HR FIRE RESISTANT EAVE PROJECTION, SEE DETAIL ON AD.2 <br />00-G-000 COVER SHEET <br />00-G-300 GENERAL DETAILS <br />01-A-000 PROJECT DATA / SITE PLAN <br />01-A-001 EXISTING SITE PLAN <br />01-A-100 EXISTING AND PROPOSED PLANS <br />01-A-101 EXISTING ROOF PLANS <br />01-A-102 EXISTING ELEVATIONS <br />01-A-200 DETACHED ADU - 1ST FLOOR PLAN & ROOF PLAN <br />01-A-201 DETACHED ADU - ELEVATIONS & SECTIONS <br />01-A-300 ARCHITECTURAL DETAILS <br />01-A-301 FIRE PROTECTION DETAILS <br />01-A-400 DOOR & WINDOW SCHEDULE & INTERIOR DETAILS <br />02-S0.0 GENERAL STRUCTURAL NOTES <br />02-S0.1 TYPICAL DETAILS <br />02-S1.0 FOUNDATION PLAN & FRAMING PLAN <br />02-SD1 STRUCTURAL DETAILS <br />02-SD2 STRUCTURAL DETAILS <br />03-G-001 CAL GREEN CODE <br />03-G-002 CAL GREEN CODE <br />03-T-000 TITLE 24 MANDATORY MEASURES SUMMARY <br />03-T-001 TITLE 24 DETACHED ADU PLAN <br />04-D-001 DRAINAGE PLAN <br />05-E-001 PROPOSED CEILING ELECTRICAL PLAN <br />CONSTRUCTION NOTES GENERAL NOTESVICINITY MAPPROJECT DATA SHEET INDEX <br />SYMBOL LEGEND <br />PARKING NOTE <br />APPLICABLE CODES <br />SITE PLAN KEYNOTES <br />DIG ALERT (811) IS TO BE CONTACTED AND THAT COMPLIANCE <br />WITH EXCAVATION SAFETY IN ACCORDANCE WITH <br />GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY <br />EXCAVATION TAKING PLACE. <br />DIG ALERT 811 <br />DIRECTORYSCOPE OF WORK <br />1/8" = 1'-0"1PROPOSED SITE PLAN <br />1 <br />1 <br />1