Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)1558 @ 2"4219 (2.25")Passed (37%)--1.0 D + 1.0 Lr (Alt Spans) <br />Shear (lbs)1369 @ 8' 11"5063 Passed (27%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)2792 @ 3' 11 7/8"5933 Passed (47%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.036 @ 4' 7 5/16"0.328 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.073 @ 4' 7 3/16"0.492 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) <br />Member Length : 15' 10 3/4" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/360) and TL (L/240). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•-263 lbs uplift at support located at 15' 10". Strapping or other restraint may be required. <br />•Applicable calculations are based on NDS. <br />• Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Column - DF 3.50"2.25"1.50"818 787 1605 1 1/4" Rim Board <br />2 - Column - DF 3.50"3.50"1.50"1225 1136 2361 None <br />3 - Column - DF 3.50"3.50"1.50"-106 -157 -263 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)15' 11" o/c <br />Bottom Edge (Lu)15' 11" o/c <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Roof Live <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)Comments <br />0 - Self Weight (PLF)1 1/4" to 16'N/A 8.6 -- <br />1 - Tapered (PSF)0 to 16' (Front)11' 3" to 0 20.0 20.0 Roof <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />ROOF, 1 : Hip bm over Bed#2 <br />2 piece(s) 2 x 12 DF No.2 <br />ForteWEB Software Operator Job Notes 12/31/2025 11:58:56 AM UTC <br />Tung Vo <br />(714) 928-2006 <br /> <br />ForteWEB v4.0, Engine: V8.4.4.42, Data: V25.26.55.57 <br />File Name: 24162 <br />Page 4 / 13Page 8