Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)5495 @ 2"7656 (3.50")Passed (72%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)3206 @ 1' 3/4"4856 Passed (66%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)3174 @ 9"5615 Passed (57%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in)0.003 @ 1' 3 15/16"0.061 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)0.007 @ 1' 3 15/16"0.123 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) <br />Member Length : 2' 9" <br />System : Wall <br />Member Type : Header <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />•Deflection criteria: LL (L/480) and TL (L/240). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Trimmer - DF 3.50"3.50"2.51"2816 2679 5495 None <br />2 - Trimmer - DF 3.00"3.00"1.50"977 943 1920 None <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)2' 9" o/c <br />Bottom Edge (Lu)2' 9" o/c <br />Dead Roof Live <br />Vertical Loads Location Tributary <br />Width <br />(0.90)(1.25)Comments <br />0 - Self Weight (PLF)0 to 2' 9"N/A 8.2 -- <br />1 - Uniform (PSF)0 to 2' 9"2'15.0 --E.Wall <br />2 - Uniform (PSF)0 to 9"5'6.0 10.0 Ceiling <br />3 - Uniform (PSF)9" to 2' 9"11'6.0 10.0 Ceiling <br />4 - Point (lb)9"N/A 3533 3365 <br />Linked from: 3 : <br />Cl'g bm right of <br />Living, Support 2 <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />ROOF, 4 : HDR right of Kitchen <br />1 piece(s) 4 x 10 DF No.2 <br />ForteWEB Software Operator Job Notes 12/31/2025 11:58:56 AM UTC <br />Tung Vo <br />(714) 928-2006 <br /> <br />ForteWEB v4.0, Engine: V8.4.4.42, Data: V25.26.55.57 <br />File Name: 24162 <br />Page 8 / 13Page 12