Laserfiche WebLink
GFIGFI <br />GF <br />I <br />D <br />GF <br />I <br />GFI <br />AF <br />C <br />I <br />AF <br />C <br />I <br />GFI <br />240V GFID <br />BUILDING WALL <br />BELOW <br />BUILDING WALL <br />BELOW <br />BUILDING WALL <br />BELOW <br />(E) ASPHALT COMP. <br />SHINGLES <br />(TO REMAIN) <br />(N) BUILT-UP ROOFING <br />22 <br />' <br />- <br />2 <br />" <br />20'-6" <br />5' <br />- <br />0 <br />" <br />17 <br />' <br />- <br />7 <br />" <br />4'-0" CLR.13'-5 1/2" <br />1'-0"3'-0" <br />2 <br />AE <br />E <br />5 <br />1' <br />- <br />0 <br />" <br />20 <br />' <br />- <br />2 <br />" <br />1' <br />- <br />0 <br />" <br />11 <br />' <br />- <br />8 <br />" <br />13'-9"9"5'-0" <br />(N) ROOF <br />VENTS <br />(N) ROOF <br />VENTS <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />PR <br />O <br />P <br />. <br /> <br />L <br />I <br />N <br />E <br />. <br />PROP. LINE. <br />1 <br />6 <br />D B <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />B3 <br />A501 <br />DEMO. EAVE. <br />SEE DETAIL <br />B3/A501 <br />B3 <br />A501 <br />(N) BUILT-UP ROOFING <br />MFG:GAF <br />Tri-Ply APP Granular Cap Sheet <br />ASTM D6222, type I, grade G <br />100AMP 120/240V, <br />1 PHASE, 3 WIRE <br />FEEDER <br />(N) 24"X36" <br />ACCESS <br />HATCH <br />GARBAGE <br />DISPOSAL <br />SWITCH <br />EXTERIOR-RATED <br />GFI OUTLET <br />EXHAUST FAN <br />MIN. 50 CFM <br />TV MOUNT OUTLET. GC TO <br />COORDINATE FINAL <br />LOCATION WITH OWNER <br />2 <br />A <br />A <br />E <br />E <br />5 <br />C <br />4' <br />- <br />6 <br />" <br />9' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />6 <br />" <br />EQ EQ <br />EQ EQ <br />EQ <br />EQ 4'-5" <br />EQ EQ <br />S <br />(N) ELECT. <br />SUBPANEL <br />RANGE HOOD <br />MIN. 280 CFM <br />RANGE <br />240V/ <br />50 AMP <br />S <br />C <br />EQ <br />EQ <br />EQ EQ <br />EXTERIOR-RATED <br />GFI OUTLET <br />1 <br />6 <br />D B <br />S <br />C <br />HOOD <br />1/ <br />2 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />SL <br />O <br />P <br />E <br />D <br /> <br />C <br />E <br />I <br />L <br />I <br />N <br />G <br />4' <br />- <br />6 <br />" <br />EQ <br />EQ <br />4' <br />- <br />0 <br />" <br />ELECTRICAL FLOOR PLAN NOTES <br />1. DUPLEX RECEPTACLE OUTLETS SHALL BE INSTALLED IN ALL ROOMS, AND AT MIN. AS FOLLOWS: <br />A. NOT MORE THAN 12'-0" O.C. ALONG WALLS. <br />B. NOT MORE THAN 6'-0" FROM OPENINGS. <br />C. ON ALL WALL SPACES 2'-0" WIDE AND WIDER AND ON THE WALL SPACE OCCUPIED BY FIXED GLASS PANELS. <br />2. ALL OUTLETS IN BATHROOM, AND WITHIN 6' OF SINKS SHALL BE G.F.I. CIRCUITS. <br />3. ALL NEW ELECTRICAL INSTALLATIONS AND LIGHTING FIXTURES SHALL BE IN COMPLIANCE WITH 2019 ENERGY CODE. <br />4. LOCATE ALL RECEPTACLE AND ELECTRICAL OUTLET 18" MIN ABOVE F.F. TO THE CENTER OF RECEPTACLE UNIT. <br />5. BATHROOM SHALL BE PROVIDED WITH MIN. 50 CFM INTERMITTENT VENTILATION EXHAUSTED DIRECTLY TO THE OUTSIDE <br />(R303.3) WITH HUMIDISTAT CONTROL. <br />6. PROVIDE FIRE RATED BLOCKING "METALCAULK BOX GUARD" AT FIRE RATED OUTLET NOTED IN PLAN TO PREVENT <br />DISCONTINUITY ON THE RATING. FIRE BLOCKING SHALL BE INSTALL IN ACCORDANCE TO UL 263 / ASTM E119 STANDARD, "FIRE <br />TEST OF BUILDING CONSTRUCTION MATERIALS." <br />7. INTERCONNECTED, HARD-WIRED SMOKE ALARMS WITH BATTERY BACK-UP SHALL BE INSTALLED PER CRC R314. <br />8. INTERCONNECTED, HARD-WIRED CARBON MONOXIDE ALARMS (UL 2034/2075 RATED) W ITH BATTERY BACK-UP SHALL BE <br />INSTALLED PER CRC R315. <br />9. ARC-FAULT (AFCI) CIRCUIT-INTERUPTER SHALL BE PROVIDED AS REQUIRED IN 210.12(A),(B),(C) AND (D). <br />10. INSTALL GROUNDING WITH 20' UFER GROUND IN FOOTING EITHER NO.4 AWG OR LARGER BARE COPPER CONDUCTOR OR #4 <br />OR LARGER REBAR, BOND, TO WATER LINE. <br />11. PROVIDE AN ISOLATED 20AMP CIRCUIT FOR THE RECEPTACLES IN EACH BATHROOM. <br />12. PROVIDE TWO 20AMP SMALL-APPLIANCE CIRCUITS FOR THE RECEPTACLES IN THE KITCHEN. <br />13. PROVIDE ONE 20AMP CIRCUIT FOR THE RECEPTACLES IN THE LAUNDRY ROOM. <br />14.PROVIDE A SEPARATE #12 AWG WIRE BRANCH CIRCUIT FOR THE RECEPTACLE AT GARBAGE DISPOSAL. <br />15. PROVIDE A SEPARATE 20AMP CIRCUIT FOR EACH FIXED APPLIANCE, SUCH AS GARBAGE DISPOSAL, DISHWASHER, W ASHING <br />MACHINE, DRYER, BUILT-IN REFRIGERATOR OR FREEZER, FURNACE, AIR CONDITIONING OR BUILT-IN HEATERS, WITH A MOTOR <br />OF 1/4HP OR LARGER. <br />16. INSTALL AT LEAST ONE GFCI RECEPTACLE IN FRONT AND ANOTHER IN THE BACK OF HOUSE. OUTSIDE RECEPTACLES SHALL <br />HAVE AN IN-USE ENCLOSURE. <br />17. INSTALL KITCHEN RECEPTACLES AT +42" ABOVE FINISH FLOOR. <br />18. INSTALL RECEPTACLES IN KITCHEN EVERY 4' ABOVE THE COUNTER. NO POINT ON THE KITCHEN WALL SHALL BE LOCATED <br />MORE THAN 24" FROM A RECEPTACLE OUTLET. <br />19. ALL OUTLETS SHALL BE TAMPER RESISTANT (CHILD PROOF). <br />20. PROVIDE A RECEPTACLE AND A LIGHT WITH SWITCH AT ATTIC ACCESS. <br />21. PRIMARY LIGHTING AT BATHS AND KITCHEN SHALL BE FLUORESCENT TYPE. <br />22. FANS SHALL BE ENERGY STAR COMPLIANT AND BE DUCTED TO TERMINATE OUTSIDE THE BUILDING. <br />23. UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A <br />HUMIDITY CONTROL. <br />A. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A ELATIVELY HUMIDITY RANGE OF LESS OR <br />EQUAL TO 50% TO A MAXIMUM OF 80%. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF <br />ADJUSTMENT. <br />B. A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE <br />INTEGRAL (I.E. BUILT-IN). <br />24. SMOKE ALARMS SHALL BE INSTALLED NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR DOOR OPENING OF A <br />BATHROOM THAT CONTAINS A BATHTUB OR SHOWER UNLESS THIS WOULD PREVENT PLACEMENT OF THE SMOKE ALARM <br />REQUIRED BY CRC SECTION R314.3. <br />25. CARBON MONOXIDE ALARMS SHALL BE PROVIDED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY <br />OF THE BEDROOMS. <br />SYMBOL DESCRIPTION <br />(E) 6" RECESSED CAN LIGHT <br />(N) 6" RECESSED CAN LIGHT <br />ELECTRICAL LIGHTING LEGEND <br />ENERGY STAR LIGHT-ACTIVATED EXHAUST FAN <br />(SEE NOTE #5 FOR MORE INFO) <br />DOWN LIGHT @ SHOWER -(WT)S <br />SWITCH -SINGLES <br />2 <br />S SMOKE ALARM (SEE NOTE #7) <br />CARBON MONOXIDE ALARM (SEE NOTE #8)C <br />NOTE: (WT) WET LOCATION LIGHTING FIXTURE <br />SYMBOL DESCRIPTION <br />PENDANT LIGHT <br />S SWITCH -DOUBLE <br />OUTLET -SINGLE <br />OUTLET -DUPLEX -AFCI/TR <br />CEILING FANSSWITCH -THREE WAY3 <br />S SWITCH -DIMMERD <br />OUTLET -DUPLEX -GFI -115VL/240VL SEE PLANGFI <br />FR OUTLET DUPLEX -FIRE RATED <br />OUTLET -TRIPLE <br />OUTLET -QUAD <br />REFLECTED CEILING PLAN LEGEND (EXISTING/ NEW) <br />(N) GYP BD. HARD LID CEILING <br />(N) HVAC SUPPLY <br />(N) HVAC RETURN <br />GENERAL NOTE: <br />CONTRACTOR TO PROVIDE SMOKE DETECTOR IN EACH SLEEPING ROOM AND <br />AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OF AREA GIVING ACCESS <br />TO EACH SEPARATE SLEEPING AREA AND IN EACH STORY OR BASEMENT; AND <br />IF SLEEPING ROOMS ARE AT AN UPPER LEVEL, PROVIDE A DETECTOR AT THE <br />CEILING OF THE UPPER LEVEL IN CLOSE PROXIMITY TO THE STAIRWAY IF <br />APPLICABLE (SEC 310.9.14 IBC). <br />MINIMUM ATTIC VENT AREA SHALL BE PER 2022 CRC R806.2. <br />ATTIC FLOOR SPACE (ADU)= 373 SF <br />373 SF / 150 = 2.48 SF X 144 = 358.08 SQ. IN. <br />MIN. VENT REQ. = 358.08 SQ IN. <br />PROVIDED VENT AREA: <br />4 (24"X16") ROOF VENTS = 1,536 SQ. IN. <br />TOTAL VENT AREA PROVIDED = 1,536 SQ. IN <br />1,536 SQ. IN. > 358.08 SQ. IN. <br />ATTIC VENT AREA CALC. <br />SWITCH -W/ VACANCY SENSOR <br />ENERGY COMPLIANCE: <br />1. EXHAUST FANS SHALL BE SWITCHED SEPARATELY FROM LIGHTING SYSTEM. LIGHTING INTEGRAL TO AN EXHAUST FAN MAY <br />BE ON THE SAME SWITCH AS THE FAN PROVIDED THE LIGHTING CAN BE SW ITCHED OFF WHILE ALLOWING THE FAN TO <br />CONTINUE TO OPERATE FOR AN EXTENDED PERIOD OF TIME. (150(K)2B CEC) <br />2. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE SPACES <br />SHALL BE CONTROLLED BY A VACANCY SENSOR. (150(K)2J CEC) <br />3. ALL JA8 COMPLAINT LIGHT SOURCES, EXCEPT THOSE IN CLOSETS LESS THAN 70 SQUARE FEET AND THOSE IN HALLWAYS, <br />SHALL BE CONTROLLED BY DIMMERS OR VACANCY SENSORS. (150(K)2K & TABLE 150.0-A CEC) JA8 COMPLIANT LIGHT SOURCES <br />INCLUDE LIGHT SOURCES IN CEILING RECESSED DOWNLIGHT LUMINAIRES AND GU-24 SOCKETS CONTAINING LED LIGHT <br />SOURCES. <br />4. ALL RESIDENTIAL OUTDOOR LIGHTING PERMANENTLY MOUNTED TO THE RESIDENCE OR OTHER BUILDINGS ON THE SAME <br />LOT SHALL BE HIGH-EFFICACY AND MEET THE FOLLOWING REQUIREMENTS: (150(K)3A CEC) <br />A. LIGHTS SHALL COMPLY WITH ONE OF THE TWO OPTIONS BELOW: <br />1. CONTROLLED BY A PHOTOCELL AND MOTION SENSOR. CONTROLS THAT OVERRIDE TO ON SHALL NOT <br />BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY REACTIVATES THE MOTION SENSOR WITHIN 6 <br />HOURS. <br />2. CONTROLLED BY (1) PHOTOCONTROL AND AUTOMATIC TIME SWITCH CONTROL OR (2) ASTRONOMICAL <br />TIME CLOCK OR (3) ENERGY MANAGEMENT CONTROL SYSTEM MEETING THE REQUIREMENTS OF <br />150(K)3A. <br />B. LIGHTS SHALL BE CONTROLLED BY A MANUAL ON AND OFF SWITCH THAT DOES NOT OVERRIDE TO ON THE <br />AUTOMATIC ACTIONS OF ITEM I OR ITEM II CHOSEN ABOVE. <br />EXTERIOR WALL SCONCE W/ PHOTOCELL SENSOR <br />SV <br />P <br />(N) WHOLE HOUSE FAN MINIMUM UNDER-FLOOR VENT AREA SHALL BE PER R408.1 <br />UNDER-FLOOR SPACE (ADU)= N/A <br />CONCRETE SLAB ON GRADE <br />UNDER-FLOOR VENTILATION AREA CALC. <br />26. ALL LIGHTING SHALL BE HIGH EFFICACY <br />27. SYSTEMS USING GAS OR PROPANE COOKTOP TO SERVE INDIVIDUAL DW ELLING UNITS SHALL INCLUDE A DEDICATED 240 <br />VOLT BRANCH CIRCUIT WIRING INSTALLED WITHIN 3 FEET FROM THE COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO <br />OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER SHALL BE <br />IDENTIFIED AS "240V READY." ALL ELECTRICAL COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA <br />ELECTRICAL CODE. (CEnC 150.0(u)) <br />28. CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS SHALL INCLUDE A <br />DEDICATED 240 VOLT BRANCH CIRCUIT WIRING INSTALLED WITHIN 3 FEET FROM THE CLOTHES DRYER LOCATION AND <br />ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS SHALL BE <br />RATED AT 30 AMPS MINIMUM. THE BLANK COVER SHALL BE IDENTIFIED AS "240V READY." ALL ELECTRICAL COMPONENTS SHALL <br />BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE (CEnC 150.0(v)) <br />29. ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND <br />AIR CONDITIONING) INTENDED TO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 IN. MEASURED FROM THE <br />TOP OF THE OUTLET BOX AND NOT LESS THAN 15 IN. MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH <br />FLOOR. (CRC R327.1.2) <br />30. DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 IN. ABOVE EXTERIOR FLOOR OR LANDING, <br />MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER <br />FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 IN. MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD <br />DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 IN. ABOVE EXTERIOR FLOOR OR <br />LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. (CRC R327.1.4) <br />17 <br />' <br />- <br />8 <br />" <br />DEMO ROOF <br />DEMO ROOF <br />(E) BUILDING WALL <br />BELOW <br />BUILDING WALL <br />BELOW <br />BUILDING WALL <br />BELOW <br />(E) ASPHALT COMP. SHINGLES <br />(TO REMAIN) <br />(N) BUILT-UP ROOFING <br />MFG:GAF <br />Tri-Ply APP Granular Cap Sheet <br />ASTM D6222, type I, grade G <br />9" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />1' <br />- <br />0 <br />" <br />1'-0" <br />18'-9" <br />1'-9" <br />PR <br />O <br />P <br />. <br /> <br />L <br />I <br />N <br />E <br />. <br />PROP. LINE. <br />3 <br />1 <br />/ <br />2 <br />" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />3 1/2" / 12" <br />2% <br /> <br />S <br />L <br />O <br />P <br />E <br />DEMO. EAVE. <br />SEE DETAIL <br />B3/A501 <br />ISSUED <br />DATE: <br />REVISIONS <br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS <br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE <br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR <br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND <br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN <br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY <br />AGREEMENT IN WRITING. <br />NO <br />. <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DRAFTER/DESIGNER: <br />LUIS N OROZCO <br />562.661.9281 <br />LUIS.OROZCO.A@LIVE.COM <br />DATE: <br />11/19/2024 <br />A102 <br />REFLECTED CEILING PLAN <br />& ROOF PLAN <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />S <br />I <br />L <br />V <br />I <br />A <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />15 <br />1 <br />1 <br /> <br />S <br />. <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />2 <br />7 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />N <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />09/10/2024 <br />Scale:1/4" = 1'-0"1 RP - PROPOSED <br />Scale:1/4" = 1'-0"2 RCP - PROPOSED <br />2 <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />1 <br />1 <br />/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />4 <br />NORTHNORTH <br />Scale:1/4" = 1'-0"3 RP - EXISTING <br />NORTH