My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
HOLD - 1511 & 1513 S Birch St - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Birch St
>
1511 S Birch St
>
HOLD - 1511 & 1513 S Birch St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2026 5:00:16 AM
Creation date
3/4/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
102122346
102122347
Full Address
1511 S Birch St
1513 S Birch St
Street Number
1513
Street Direction
S
Street Name
Birch
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
6" <br />3' <br />- <br />0 <br />" <br />6" <br />3' <br />- <br />0 <br />" <br />3' <br />- <br />7 <br />" <br />TEMPERED <br />GLAZING <br />7' <br />- <br />0 <br />" <br />4" <br />TEMPERED <br />GLAZING <br />7' <br />- <br />0 <br />" <br />4" <br />4' <br />- <br />0 <br />" <br />3' <br />- <br />0 <br />" <br />30" MIN. <br />8' <br />- <br />0 <br />" <br />SH <br />O <br />W <br />E <br />R <br />2' <br />- <br />6 <br />" <br />DA <br />M <br />4 <br />1 <br />/ <br />2 <br />" <br />5'-0" <br />EQ <br />EQ <br />30 <br />" <br /> <br />M <br />I <br />N <br />. <br />3' <br />- <br />1 <br /> <br />1 <br />/ <br />2 <br />" <br />VA <br />N <br />I <br />T <br />Y <br />2' <br />- <br />0 <br />" <br />24" MIN. <br />2'-4 1/2" <br />RANGE <br />2'-0"1" <br />CABINETS <br />4'-6"1" <br />REF <br />2'-0" <br />CO <br />U <br />N <br />T <br />E <br />R <br />T <br />O <br />P <br />2' <br />- <br />1 <br />" <br />A301 2B <br />2A <br />B <br />8'-8" <br />30 <br />" <br /> <br />C <br />L <br />R <br />. <br />CLEAR <br />4'-1 1/2" <br />30 <br />" <br /> <br />C <br />L <br />R <br />KITCHEN <br />HOOD <br />GFI <br />EQEQEQ2'-2" <br />2'-6"1'-0"1'-0"2'-0"2'-0" <br />A502 <br />D1 <br />TYP <br />ISSUED <br />DATE: <br />REVISIONS <br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS <br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE <br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR <br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND <br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN <br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY <br />AGREEMENT IN WRITING. <br />NO <br />. <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DRAFTER/DESIGNER: <br />LUIS N OROZCO <br />562.661.9281 <br />LUIS.OROZCO.A@LIVE.COM <br />DATE: <br />A301 <br />ENLARGED FLOOR PLANS <br />& INTERIOR ELEVATIONS <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />S <br />I <br />L <br />V <br />I <br />A <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />15 <br />1 <br />1 <br /> <br />S <br />. <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />2 <br />7 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />N <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />09/10/2024 <br />Scale:1/2" = 1'-0"1A BATHROOM - TYP. <br />Scale:1/2" = 1'-0"1B BATHROOM - TYP. <br />Scale:1/2" = 1'-0"1C BATHROOM - TYP. <br />Scale:1/2" = 1'-0"1D BATHROOM - TYP. <br />PER CRC SECTION R327, BATHROOM SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED <br />AS FOLLOWS: <br />1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS <br />APPROVED BY THE ENFORCING AGENCY. <br />2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 IN. NOMINAL LUMBER. OR OTHER <br />CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT <br />SHALL BE LOCATED BETWEEN 32 IN. AND 39 1/4 IN. ABOVE THE FINISHED FLOOR FLUSH WITH <br />THE WALL FRAMING. <br />3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE <br />FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. <br />4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. <br />5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS <br />ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL <br />REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE <br />LOCATED NO MORE THAN 6 IN. ABOVE THE BATHTUB RIM. <br />Scale:1/2" = 1'-0"1 FP - BATH (ENLARGED) <br />Scale:1/2" = 1'-0"2 FP - KITCHENETTE (ENLARGED) <br />Scale:1/2" = 1'-0"2B KITCHENETTE (SOUTH) <br />Scale:1/2" = 1'-0"2A KITCHENETTE (EAST) <br />WASHER & <br />DRYER
The URL can be used to link to this page
Your browser does not support the video tag.