My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1409 W Meriday Ln - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Meriday Ln
>
1409 W Meriday Ln
>
1409 W Meriday Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2026 5:00:15 AM
Creation date
3/4/2026 5:00:07 AM
Metadata
Fields
Template:
Plan
Permit Number
101125647
Full Address
1409 W Meriday Ln
Street Number
1409
Street Direction
W
Street Name
Meriday
Street Suffix
Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DETAIL SHEET NUMBER <br />DROP IN SLAB (VERIFY PRIOR TO CONSTRUCTION) <br />SYMBOLS LEGEND <br />SDX <br />X DETAIL NUMBER <br />EXISTING FOOTING <br />REBAR <br />NEW SLAB/ FOOTING <br />HOLDOWN SCHEDULE: <br />FOUNDATION NOTES: <br />1. REFER TO S.0 SHEET FOR MORE INFO. <br />2. REFER TO DETAILS 4,14/SD1 FOR INSTALLATION OF HOLDOWNS. <br />3. FOUNDATION ANCHOR BOLTS IN CONTACT WITH PRESSURE TREATED SILL <br />PLATE SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS <br />STEEL, SILICON BRONZE OR COPPER. <br />EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/ DOT AND ZINC BORATE <br />PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE <br />PERMITTED. <br />4. CONTRACTOR SHALL VERIFY ALL EXISTING FOOTINGS AND NOTIFY TO ENG. OF <br />RECORD FOR ALL DISCREPANCIES. <br />5. HOLDOWN ANCHORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE <br />WALL FRAMING. <br />6. ALL HOLDOWN ANCHORS SHALL BE TIED IN PLACE PRIOR TO CALLING <br />FOUNDATION INSPECTION. <br />7. SEE DETAIL 12/SD2 FOR PLATE NOTCHING & BORING. FOR PIPING THRU SILL & <br />TOP PLATES OF SHEAR WALLS, CONTACT DONG ENGINEERING, INC. <br />8. THE HOLDOWN POST SIZE SHALL FOLLOW THE HOLDOWN SCHEDULE U.N.O. <br />9. ALL EXTERIOR WALLS AND INTERIOR BEARING WALLS TO HAVE 5/8" DIA. X MIN. <br />12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. <br />UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED <br />MAX. 12" AWAY AND MIN. 4 1/2" FROM THE END OF THE SILL PLATES. MIN. (2) A.BS. <br />PER SILL PLATE/SHEAR PANEL. SILL PLATE UNDER SHEAR WALLS OF UP TO 4'-0" IN <br />LENGTH MUST BE CONTINUOUS. <br />10. ALL INTERIOR NON-SHEAR WALLS TO BE SECURED WITH SIMPSON PHNW <br />SERIES 0.145Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE <br />INSTALLED IN ACCORDANCE WITH ICC ESR-2138. <br />11. ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS <br />OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE <br />WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL(S). <br />PAD SCHEDULE: <br />PAD TYPESYM. <br />HDUE3 <br />HDUE5 <br />HDUE7 <br />HOLDOWNSYM. <br />HDUE9 <br />POST SIZE <br />4X <br />4X <br />4X <br />REF. DETAIL <br />4,14/SD1 <br />HDUE13 <br />HDUE13 <br />HDUE9 4X <br />6X <br />6X <br />8X <br />1. HOLDOWN POST MINIMUM THICKNESS IS SHOWN ON SCHEDULE ABOVE. <br />ACTUAL HOLDOWN POST SIZE IS INDICATED ON PLAN. <br />2. APPLICABLE IN 6" MIN. STUD WALL. <br />6X <br />6X <br />HDUE17 <br />HDUE172 <br />SHEAR PANEL LENGTH AND NUMBER. <br />SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. <br />X <br />INDICATES HOLDOWN, SEE HOLDOWNS SCHEDULE <br />KITCHEN <br />DINING <br />LIVING ROOM <br />HALLWAY <br />BEDROOM BEDROOM <br />BATH <br />BEDROOM <br />A <br />B <br />1 <br />2 <br />3 <br />16'-0" <br />A <br />H3 <br />6' <br />- <br />0 <br />" <br />A <br />H3 <br />6' <br />- <br />6 <br />" <br />A <br />H3 <br />7' <br />- <br />9 <br />" <br />A <br />H3 <br />8' <br />- <br />0 <br />" <br />A <br />H3 <br />H3 <br />4' <br />- <br />0 <br />" <br />A <br />H3 <br />5'-6" <br />A H3H3 <br />8'-0" <br />A H3H3 <br />H3 <br />P3030 <br />4 <br />SD1 <br />TYP. <br />6 <br />SD1 <br />11 <br />SD1 <br />3 <br />SD1 <br />3 <br />SD1 <br />3 <br />SD1 <br />10 <br />SD1 <br />10 <br />SD1 <br />10 <br />SD1 <br />9 <br />SD19 <br />SD1 <br />2 <br />SD1 <br />6 <br />SD1 <br />6 <br />SD1 <br />1 <br />SD1 <br />1 <br />SD1 <br />1 <br />SD1 <br />1 <br />SD1 <br />1 <br />SD1 5 <br />SD1 <br />12 <br />" <br />12" <br />12" <br />12" <br />12 <br />" <br />(E) FOOTING, V.I.F. <br />6 <br />SD1 <br />4' <br />- <br />0 <br />" <br />A (E) FOOTING, V.I.F. <br />(E) FOOTING, V.I.F. <br />(E) CONCRETE SLAB <br />TO BE REMAINED <br />2 <br />SD1 <br />(E) RAISED FLOOR SYSTEM <br />TO BE REMAINED <br />F1 <br />5 <br />SD1 <br />F1 <br />24" WIDTH & 18" HEIGHT <br />CRAWL SPACE OPENING, TYP. <br />8 <br />SD1 <br />24 <br />" <br />14'-10" <br />9' <br />5 <br />SD1 <br />24" <br />H3 <br />10 <br />SD1 <br />18'-5" <br />1 <br />2'-6" SQ. X 18" DEEP PAD W/ (3) #5 E.W. BOTT.P3030 <br />SHEAR PANEL LENGTH AND NUMBER. <br />SEE SW SCHED. FOR PANEL TYPE, MIN. 2x4 @ EA. END. <br />X DETAIL NUMBER DETAIL SHEET NUMBER <br />CALIFORNIA FRAMING <br />BEAM NUMBER, REFER TO CALCULATIONS. <br />LEGEND: <br />INDICATES EXISTING ROOF RAFTER <br />FRAMING NOTES: <br />6X6 INDICATES BEAM SIZE (DFL HEADER/DROP) U.N.O. <br />BEARING WALLS, SEE PLAN. <br />INDICATES NEW ROOF RAFTER, SEE JOISTS TABLE <br />XX <br />POST SIZE, SEE POST SCHEDULE. <br />XPOST SCHEDULE: <br />POST SIZESYM. <br />24 <br />224 <br />324 <br />26 <br />226 <br />2X4 STUD <br />(2)-2X4 BUNDLED STUD <br />(3)-2X4 BUNDLED STUD <br />2X6 STUD <br />(2)-2X6 BUNDLED STUD <br />326 <br />44 <br />46 <br />66 <br />(3)-2X6 BUNDLED STUD <br />4X4 POST <br />4X6 POST <br />6X6 POST <br />POST SIZESYM. <br />INDICATES CEILING JOISTS, SEE JOISTS TABLE <br />1. REFER TO STRUCTURAL GENERAL NOTES AND DETAIL SHEETS S.0 FOR <br />MORE INFORMATION. <br />3. HANGERS FOR FLUSH FRAMED MEMBERS SHALL BE SIMPSON STRONG-TIE <br />AS FOLLOWS U.N.O.: <br />2. ALL VERTICAL PIPES THROUGH PLATES AND/OR SOLID RIM BEAMS MUST <br />BE DRILLED CLEAN CUT W/ 1/16" TOLERANCE. DO NOT NOTCH OR CUT <br />PLATES. <br />- 2x4's @ 16" o.c. maximum 14'-0" height <br />- 2x6's @ 16" o.c. maximum 20'-0" height <br />5. BUILDING CODE 2308.9.1 BALLOON FRAMED WALLS (NON-BEARING) STUD <br />HEIGHTS: <br />6. BEARING STUD HEIGHTS: <br />- 2x4's @ 16" o.c. maximum 10'-0" height <br />- 2x6's @ 16" o.c. maximum 16'-0" height <br />4. THE FOLLOWING TRIMMER SCHEDULE SHOULD BE USED FOR HEADERS IN <br />BEARING WALLS, U.N.O. ON THE PLAN. REQUIRED TRIMMER MUST BE <br />APPLIED @ EACH END OF HEADER. <br />CLEAR SPAN, L <br /> L ≤ 6'-0" 6'-0" < L ≤ 10'-0" L ≥ 10'-0" <br />2 x 4 2-2 x 4 2-2X4 U.N.O. PER PLAN <br />CONSTRUCTION KEY NOTES: <br />STRAPS SCHEDULE: <br />JOISTS TABLE: <br />MARK JOIST SPECIFICATIONS <br />R1 <br />R2 ROOF RAFTER 2 x 6 DFL#2 @ 16" O.C. W/ PURLIN <br />C1 CEILING JOIST 2 x 6 DFL#2 @ 16" O.C. <br />MARK STRAP STRAP <br />LENGTH <br />NAILS/ SPACING REFERENCE <br />DETAIL <br />8d BOX/SINKER @ 4-1/8" <br />8d BOX/SINKER @ 4-1/8" <br />16d SINKER @ 4-1/2" <br />CS16 <br />(2)CS16 <br />CMSTC16 <br />5 <br />6 <br />7 <br />3' - 6" <br />3' - 6" <br />3' - 6" <br />9/SD2 <br />CS16 <br />(2)CS16 <br />8 <br />9 <br />3' - 6" <br />3' - 6" <br />8d BOX/SINKER @ 2-1/16" O.C. <br />8d BOX/SINKER @ 2-1/16" O.C.10/SD2 <br />LUS <br />FACE MOUNT TOP FLANGED <br />HANGER TYPEMEMBER <br />2X JOIST <br />4X, 6X, LSL or PSL <br />TJI I-JOIST <br />JB <br />HU W/ MAX. BA <br />IUS ITS <br />ALIGN STUD(S) / POST(S) WITH UPPER FLOOR STUD(S) / POST(S) <br />AND PROVIDE SOLID BLOCKING BETWEEN FLOOR <br />PROVIDE SOLID BLOCKING UNDER GIRDER / BEAM. <br />LINE OF 2X BLOCKING W/ EDGE NAIL. & CONTINUOUS CS16 STRAP OVER <br />U.N.O. SEE PLAN FOR NUMBER OF BAYS. <br />PROVIDE STRAP TYPE "X" AT SHEAR WALL TOP PLATE SPLICE PER <br />DETAIL 16/SD2. <br />"X" <br />ROOF RAFTER 2 x 6 DFL#2 @ 16" O.C. <br />F1 FLOOR JOIST 2 x 6 DFL#2 @ 16" O.C. <br />INDICATES FLOOR JOIST, SEE JOISTS TABLE <br />RESTRICTIVE NOTICE <br />DATE REVISIONS <br />SHEET DESCRIPTION <br />PROJECT OWNER <br />PROJECT ADDRESS <br />STAMP <br />NO <br />REVISIONS <br />DATE SIGNED: 1/5/26 <br />THESE DESIGNS, DRAWINGS, AND <br />SPECIFICATIONS ARE THE EXCLUSIVE <br />PROPERTY OF DONG ENGINEERING. <br />THESE DRAWINGS CANNOT BE COPIED, <br />TRANSFERRED, OR REPRODUCED NOR <br />CAN ANY OTHER STRUCTURES BE BUILT <br />FROM THEM WITHOUT WRITTEN CONSENT. <br />SHEET <br />DE#: <br />TEL- 714-617-5979 <br />GARDEN GROVE, CA 92841 <br />7661 GARDEN GROVE BLVD., <br />DONG ENGINEERING, INC. <br />RE <br />M <br />O <br />D <br />E <br />L <br /> <br />& <br /> <br />A <br />D <br />D <br />I <br />T <br />I <br />O <br />N <br />14 <br />0 <br />9 <br /> <br />M <br />E <br />R <br />I <br />D <br />A <br />Y <br /> <br />L <br />N <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />01/05/2026 PLAN CHECK1 <br />S1 <br />FOUNDATION PLAN <br />SCALE: <br />FOUNDATION PLAN
The URL can be used to link to this page
Your browser does not support the video tag.