Laserfiche WebLink
/ce/ <br />PAGE <br />REV: C2 5/15/2025 <br />VICTORIA HUYNH <br />1915 TRASK AVE, SANTA ANA,  <br />CA, 92706 <br />PROJECT NUMBER: <br />  109R-915HUYN <br />SHEET <br />DESIGNER: <br />NOORUDDIN AJAM <br />CUSTOMER RESIDENCE: <br />TEL. (714) 519-8517 <br />APN: 101-042-29 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />#SSTAMP <br />DESIGN CRITERIA <br />MAX DISTRIBUTED LOAD: 3 PSF <br />SNOW LOAD: 0 PSF <br />WIND SPEED:  <br />96 MPH 3-SEC GUST. <br />FASTENERS: <br />(1) 5/16" DIA UMBRELLA LAG  <br />SCREW: 2.5" MIN EMBEDMENT  <br />INTO FRAMING <br />PV-3.0 <br />LAYOUT <br />EXISTING STRUCTURE IS ASSUMED TO BE  <br />A LIGHT-FRAME WOOD ROOF AND FREE  <br />FROM DAMAGE, DETERIORATION, OR  <br />MODIFICATION THAT WOULD COMPROMISE  <br />ITS ORIGINAL DESIGN INTEGRITY.  <br />CONTACT ENGINEER OF RECORD IF  <br />FOLLOWING MINIMUM REQUIREMENTS ARE  <br />NOT SATISFIED IN COMPLIANCE WITH THE  <br />STATED RACKING DESIGN: <br />4" <br />SOLAR MODULE <br />SNAPNRACK  <br />RACKING <br />MODULE ELEVATION DETAIL - SCALE: NTS <br />INSTALLERS SHALL NOTIFY ENGINEER OF ANY  <br />POTENTIAL STRUCTURAL ISSUES OBSERVED  <br />PRIOR TO PROCEEDING W/ INSTALLATION. <br />* IF ARRAY (EXCLUDING SKIRT) IS WITHIN 12"  <br />BOUNDARY REGION OF ANY ROOF PLANE  <br />EDGES (EXCEPT VALLEYS), THEN  <br />ATTACHMENTS NEED TO BE ADDED AND  <br />OVERHANG REDUCED WITHIN THE 12"  <br />BOUNDARY REGION ONLY AS FOLLOWS: <br />** ALLOWABLE ATTACHMENT SPACING  <br />INDICATED ON PLANS TO BE REDUCED BY 50%. <br />** ALLOWABLE OVERHANG INDICATED ON  <br />PLANS TO BE 1/5TH OF ALLOWABLE  <br />ATTACHMENT SPACING INDICATED ON PLANS. <br />D1 - AR-01 - SCALE: 0'-0 1/8" = 1'-0" <br />AZIM: 180° <br />PITCH: 19° <br />D2 - AR-02 - SCALE: 0'-0 1/8" = 1'-0" <br />AZIM: 270° <br />PITCH: 22° <br />ROOF INFO ATTACHMENT INFORMATION <br />Name Type Height Detail Max Landscape  <br />OC Spacing <br />Max Landscape  <br />Overhang <br />Max Portrait  <br />OC Spacing <br />Max Portrait  <br />Overhang Configuration <br />AR-01 COMP SHINGLE - UMBRELLA L FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING -  <br />SNR-DC-00339 5'-4" 2'-1" 5'-4" 2'-1" STACKED <br />AR-02 COMP SHINGLE -  UMBRELLA L FOOT 1-Story ULTRA RAIL, ATTACHMENT DETAIL, UMBRELLA L FOOT TO FRAMING - SNR-DC-00339 5'-4" 2'-1" 5'-4" 2'-1" STACKED <br />26'-5"7'-8"15'-1" <br />49'-2" <br />11'-4" <br />4'-7"2'-5" <br />6'-9" <br />2'-9" <br />2'-10" <br />4'-2" <br />4'-10" <br />26'-5" <br />11'-4" <br />12'-1"10'-1" <br />3'-4" <br />8'-1" <br />1'-6" <br />5'-9" <br />2" <br />5'-4" TYP <br />5'-4" TYP <br />C2 <br />C2 <br />C2 <br />C2 <br />C2 <br />Exp. 12/31/2026Digitally Signed On: 05/21/25