Laserfiche WebLink
PAGE <br />REV: C2 5/15/2025 <br />VICTORIA HUYNH <br />1915 TRASK AVE, SANTA ANA,  <br />CA, 92706 <br />PROJECT NUMBER: <br />  109R-915HUYN <br />SHEET <br />DESIGNER: <br />NOORUDDIN AJAM <br />CUSTOMER RESIDENCE: <br />TEL. (714) 519-8517 <br />APN: 101-042-29 <br />(415) 580-6920 ex3 <br />Template_version_v5_2024 02 28 <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603   <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />#ESTAMP <br />SYSTEM INFORMATION <br />15.01 KW DC PHOTOVOLTAIC SYSTEM <br />     (14) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y <br />     (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y <br />     (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y <br />ALLOWABLE BACKFEED <br />MAX ALLOWED TOTAL GENERATION BACKFEED OCPD = MAIN BREAKER RATING = <br />200A <br />180A ≤ 200A→ INTERCONNECTION MEETS 705.13 REQUIREMENTS. <br />SYSTEM OCPD SIZE <br />(COMBINED MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION <br />INVERTER INFORMATION <br />5530 KW DC PHOTOVOLTAIC SYSTEM <br />     (14) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS LOAD)[690.8(B)(1)]=  <br />15A X 1.25 = 18.75A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  <br />(CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 0.8 X 40A = 29.12A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG,  RATED = 35A <br />29.12A < 35A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />18.75A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS LOAD)[210.19(A)(1)] = <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT FILL)[TABLE 310.15(C)(1)] X  <br />(CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 0.8 X 75A = 81.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  RATED = 65A <br />65A < 81.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = [((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC TEMP] + VOC X (#  <br />MODULES / STRING) = <br />[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V X 7 = 276 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.79 A X 2 = 36.97A <br />INVERTER INFORMATION <br />4740 KW DC PHOTOVOLTAIC SYSTEM <br />     (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA: POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  <br />LOAD)[690.8(B)(1)]=  <br />15A X 1.25 = 18.75A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG,  RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />18.75A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS  <br />LOAD)[210.19(A)(1)] = <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 0.8 X 75A = 81.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  RATED = 65A <br />65A < 81.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = [((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  <br />TEMP] + VOC X (# MODULES / STRING) = <br />[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V X 12 = 473 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.79 A X 1 = 18.48A <br />INVERTER INFORMATION <br />4740 KW DC PHOTOVOLTAIC SYSTEM <br />     (12) LONGI GREEN ENERGY TECHNOLOGY CO LTD: LR5-54HABB-395M, TESLA:  <br />POWERWALL 3 1707000-XX-Y <br />INVERTER OVERCURRENT PROTECTION <br />(INVERTER MAX CURRENT) X (CONTINUOUS LOAD) =  <br />48 A X 1.25 = 60 A → 60 A OVERCURRENT PROTECTION PER MANUFACTURER <br />DC WIRE SIZING <br />MAX CIRCUIT CURRENT = (MODULE ISC) X (HIGH IRRADIANCE)[690.8(A)(1)] X (CONTINUOUS  <br />LOAD)[690.8(B)(1)]=  <br />15A X 1.25 = 18.75A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 1 X 40A = 36.4A <br />TERMINAL RATING[110.14(C)] = <br />10 AWG,  RATED = 35A <br />35A < 36.4A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />18.75A < 35A → 10 AWG AMPACITY OK <br />THEREFORE 10 AWG IS SUFFICIENT. <br />AC WIRE SIZING <br />MAX AC OUTPUT CURRENT = (MAX INVERTER OUTPUT) X (CONTINUOUS  <br />LOAD)[210.19(A)(1)] = <br />48 A X 1.25 = 60 A <br />ADJUSTED CONDUCTOR AMPACITY = (HIGH TEMP)[TABLE 310.15(B)(1)] X (CONDUIT  <br />FILL)[TABLE 310.15(C)(1)] X (CONDUCTOR AMPACITY)[TABLE 310.16] =  <br />0.91 X 0.8 X 75A = 81.25A <br />TERMINAL RATING[110.14(C)] = <br />6 AWG,  RATED = 65A <br />65A < 81.25A →  TERMINAL RATING GOVERNS CONDUCTOR SIZING. <br />60A < 65A → 6 AWG AMPACITY OK <br />THEREFORE 6 AWG IS SUFFICIENT. <br />SYSTEM CHARACTERISTICS <br />MAX OPEN CIRCUIT VOLTAGE   = [((TEMP COEF VOC) X (VOC)) / 100] X [LOW TEMP - STC  <br />TEMP] + VOC X (# MODULES / STRING) = <br />[(-0.26 %/°C X 36.81 V) / 100] X [-2 °C - 25 °C] + 36.81 V X 12 = 473 V <br />SHORT CIRCUIT CURRENT = 1.25 X (MODULE ISC) X (# STRINGS) <br />1.25 X 14.79 A X 1 = 18.48A PV-4.1 <br />ELECTRICAL CALCS <br />C2 <br />C2