My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2390 S Redhill Ave #C - Plan
PBA
>
Building
>
ProjectDox
>
R
>
Redhill Ave
>
2390 S Redhill Ave Unit# C
>
2390 S Redhill Ave #C - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2026 5:00:23 AM
Creation date
3/5/2026 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20186677
30149228
40140677
101124697
Full Address
2390 S Redhill Ave Unit# C
Street Number
2390
Street Direction
S
Street Name
Redhill
Street Suffix
Ave
Unit Number
C
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Generated Date/Time:Documentation Software: EnergyPro <br />CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220101 <br />Compliance ID: EnergyPro-50399-0325-0081 <br />Report Generated: 2025-03-28 08:41:35 <br />STATE OF CALIFORNIA <br />Indoor Lighting CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-LTI-E <br />This document is used to demonstrate compliance with requirements in 110.9, 110.12(c), 130.0, 130.1, 140.6 and 141.0(b)2 for indoor lighting scopes using the prescriptive path for <br />nonresidential and hotel/motel occupancies. It is also used to document compliance with requirements in 160.5, 170.2(e) and 180.2(b)4 for indoor lighting scopes using the prescriptive <br />path for multifamily occupancies. Multifamily includes dormitory and senior living facilities. <br />Project Name: STRONG Report Page: (Page 1 of 7) <br />Project Address: 1450 Cloverfield Blvd.Date Prepared: 3/28/2025 <br />A. GENERAL INFORMATION <br />01 Project Location (city)Santa Monica 04 Total Conditioned Floor Area (ft2)2,061 <br />02 Climate Zone 6 05 Total Unconditioned Floor Area (ft2)0 <br />03 Occupancy Types Within Project (select all that apply):06 # of Stories (Habitable Above Grade)1 <br />● Gymnasium ● Support Areas ● All Other Occupancies <br />B. PROJECT SCOPE <br />This table includes any lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.6 / 170.2(e) or <br />141.0(b)2 / 180.2(b)4 for alterations. <br />Scope of Work Conditioned Spaces Unconditioned Spaces <br />01 02 03 04 05 <br />My Project Consists of (check all that apply):Calculation Method Area (ft2)Calculation Method Area (ft2) <br />New Lighting System Area Category Method 2061 Area Category Method 0 <br />New Lighting System - Parking Garage <br />Total Area of Work (ft2)2061 0
The URL can be used to link to this page
Your browser does not support the video tag.