Laserfiche WebLink
0 5' <br />GRAPHIC SCALES: <br />Issue Date <br />1/16" = 1'-0" <br />50' <br />1/8" = 1'-0"1/4" = 1'-0"1/2" = 1'-0"3/4" = 1'-0"1" = 1'-0"1-1/2" = 1'-0"3" = 1'-0" <br />0 5'25'0 1'12'0 1'6'0 4'0 3'1'0 2'0 1' <br />Chckd By <br />Drwn By <br />Scale <br />Building ID: <br />KP Proj. No. <br />Permit No. <br />Sheet <br />SheetsOf <br />Sheet Title <br />Project <br />Facility <br />This document is the property of the Owner and is <br />Project Architect Approval: <br />Architect/Engineer Of Record: <br />IF THIS SHEET IS NOT 30"x42" , IT IS <br />A REDUCED PRINT - SCALE ACCORDINGLY <br />National Facilities Services <br />Post Office Box 12916 <br />Oakland California 94604 <br />not to be used without owner's written permission. <br />Floor Lev:Section: <br />Revisions <br />By Appr. <br />HGW Proj. No. <br />© <br />A <br />R <br />C <br />H <br />I <br />T <br />E <br />C <br />T <br />S <br /> <br />h <br />a <br />n <br />n <br />a <br /> <br />g <br />a <br />b <br />r <br />i <br />e <br />l <br /> <br />w <br />e <br />l <br />l <br />s <br />, <br /> <br />a <br />l <br />l <br /> <br />r <br />i <br />g <br />h <br />t <br />s <br /> <br />r <br />e <br />s <br />e <br />r <br />v <br />e <br />d <br />. <br /> <br /> <br />A <br />n <br />y <br /> <br />u <br />s <br />e <br /> w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />i <br />s <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br />l <br />y <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br /> <br /> <br />P <br />l <br />o <br />t <br />t <br />e <br />d <br />1955 Bacon Street. San Diego, CA 92107 <br />Office 619 523 8487 <br />www.hgwarchitecture.com <br />KAISER PERMANENTE <br />BUILDINGS ON BRAND <br />1/ <br />2 <br />1 <br />/ <br />2 <br />0 <br />2 <br />6 <br /> <br />5 <br />: <br />2 <br />3 <br />: <br />5 <br />3 <br /> <br />P <br />M <br />01/23/2026 <br />Checker <br />Author <br />CAP030945 <br />T151 <br />ACCESSIBILITY NOTES <br />Santa Ana Medical Offices <br />1900 E. 4th Street <br />Santa Ana, CA, 92701 <br />PL <br />A <br />N <br /> <br />C <br />H <br />E <br />C <br />K <br /> <br />R <br />E <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br />2505 <br />SANTA ANA <br />1. <br />2. <br />1. <br />11B- 407 Elevators11B- 407 Elevators <br />11B-407.1 General - 11B-407.1 General - Elevators shall comply with Section 11B-407 and with ASME A17.1 They shall be <br />passenger elevators as classified by ASME A17.1. Elevator operation shall be automatic. <br />11B-407.1.1 Combined Passenger and Freight Elevators - 11B-407.1.1 Combined Passenger and Freight Elevators - When the only elevators provided for use by the <br />public and employees are combination passenger and freight elevators, they shall comply with Section 11B-407 <br />and with ASME A17.1. <br />11B-407.2 Elevator Landing Requirements - 11B-407.2 Elevator Landing Requirements - Elevator landings shall comply with Section 11B-407.2. <br />11B-407.2.1 Call Controls - 11B-407.2.1 Call Controls - Where elevator call buttons or keypads are provided, they shall comply with <br />Sections 11B-407.2.1 and 11B-309.4. <br />11B-407.2.1.1 Height - 11B-407.2.1.1 Height - Call buttons and keypads shall be located within one of the reach ranges <br />specified in Section 11B-308, measured to the centerline of the highest operable part. <br />11B-407.2.1.2 Size and Shape - 11B-407.2.1.2 Size and Shape - Call buttons shall have square shoulders, be 3/4 inch (19.1 mm) <br />minimum in the smallest dimension and shall be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch <br />(0.8 mm) above the surrounding surface. The buttons shall be activated by a mechanical motion that is <br />detectable. <br />11B-407.2.1.3 Clear Floor or Ground Space - 11B-407.2.1.3 Clear Floor or Ground Space - A clear floor or ground space complying with Section <br />11B-305 shall be provided at call controls. <br />11B-407.2.1.4 Location - 11B-407.2.1.4 Location - The call button that designates the up direction shall be located above the <br />call button that designates the down direction. <br />11B-407.2.1.5 Signals - 11B-407.2.1.5 Signals - Call buttons shall have visible signals that will activate when each call is <br />registered and will extinguish when each call is answered. Call buttons shall be internally illuminated <br />with a white light over the entire surface of the button. <br />11B-407.2.1.6 Keypads - 11B-407.2.1.6 Keypads - Where keypads are provided, keypads shall be in a standard telephone <br />keypad arrangement and shall comply with Section 11B-407.4.7.2. <br />11B-407.2.2 Hall Signals - 11B-407.2.2 Hall Signals - Hall signals, including in-car signals, shall comply with Section 11B-407.2.2. <br />11B-407.2.2.1 Visible and Audible Signals - 11B-407.2.2.1 Visible and Audible Signals - A visible and audible signal shall be provided at each <br />hoistway entrance to indicate which car is answering a call and the car's direction of travel. Where in-car <br />signals are provided, they shall be visible from the floor area adjacent to the hall call buttons. <br />11B-407.2.2.2 Visible Signals - 11B-407.2.2.2 Visible Signals - Visible signal fixtures shall be centered at 72 inches (1829 mm) <br />minimum above the finish floor or ground. The visible signal elements shall be a minimum 21/2 inches <br />(64 mm) high by 21/2 inches (64 mm) wide. Signals shall be visible from the floor area adjacent to the <br />hall call button. <br />11B-407.2.2.3 Audible Signals - 11B-407.2.2.3 Audible Signals - Audible signals shall sound once for the up direction and twice for <br />the down direction, or shall have verbal annunciators that indicate the direction of elevator car travel. <br />Audible signals shall have a frequency of 1500 Hz maximum. Verbal annunciators shall have a <br />frequency of 300 Hz minimum and 3000 Hz maximum. The audible signal and verbal annunciator shall <br />be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. <br />11B-407.2.2.4 - 11B-407.2.2.4 - Reserved <br />11B-407.2.3 Hoistway Signs - 11B-407.2.3 Hoistway Signs - Signs at elevator hoistways shall comply with Section 11B-407.2.3. <br />11B-407.2.3.1 Floor Designation - 11B-407.2.3.1 Floor Designation - Floor designations complying with Sections 11B-703.2 and <br />11B-703.4.1 shall be provided on both jambs of elevator hoistway entrances. Floor designations shall <br />be provided in both raised characters and Braille. Raised characters shall be 2 inches (51 mm) high. A <br />raised star, placed to the left of the floor designation, shall be provided on both jambs at the main entry <br />level. The outside diameter of the star shall be 2 inches (51 mm) and all points shall be of equal length. <br />Raised characters, including the star, shall be white on a black background. Braille complying with <br />Section 11B-703.3 shall be placed below the corresponding raised characters and the star. The Braille <br />translation for the star shall be "MAIN". Applied plates are acceptable if they are permanently fixed to the <br />jamb. <br />11B-407.2.3.2 - 11B-407.2.3.2 - Reserved <br />11B-407.3 Elevator Door Requirements - 11B-407.3 Elevator Door Requirements - Hoistway and car doors shall comply with Section 11B-407.3. <br />11B-407.3.1 Type - 11B-407.3.1 Type - Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited. <br />11B-407.3.2 Operation - 11B-407.3.2 Operation - Elevator hoistway and car doors shall open and close automatically. <br />Exception:Exception: Existing manually operated hoistway swing doors shall be permitted provided that they <br />comply with Sections 11B-404.2.3 and 11B-404.2.9. Car door closing shall not be initiated until the <br />hoistway door is closed. <br />11B-407.3.3 Reopening Device - 11B-407.3.3 Reopening Device - Elevator doors shall be provided with a reopening device complying with <br />Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door <br />becomes obstructed by an object or person. <br />Exception:Exception: Existing elevators with manually operated doors shall not be required to comply with Section <br />11B-407.3.3. <br />11B-407.3.3.1 Height - 11B-407.3.3.1 Height - The device shall be activated by sensing an obstruction passing through the <br />opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor. <br />11B-407.3.3.2 Contact - 11B-407.3.3.2 Contact - The device shall not require physical contact to be activated, although <br />contact is permitted to occur before the door reverses. <br />11B-407.3.3.3 Duration - 11B-407.3.3.3 Duration - Door reopening devices shall remain effective for 20 seconds minimum. <br />11B-407.3.4 Door and Signal Timing - 11B-407.3.4 Door and Signal Timing - The minimum acceptable time from notification that a car is <br />answering a call until the doors of that car start to close shall be calculated from the following equation: <br />T = D/(1.5 ft/s) or T = D/(457 mm/s) = 5 seconds minimum where T equals the total time in seconds and <br />D equals the distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) <br />directly in front of the farthest call button controlling that car to the centerline of its hoistway door. <br />Exceptions:Exceptions: <br />For cars with in-car lanterns, T shall be permitted to begin when the signal is visible from the <br />point 60 inches (1524 mm) directly in front of the farthest hall call button and the audible <br />signal is sounded. <br />Reserved. <br />11B-407.3.5 Door Delay - 11B-407.3.5 Door Delay - Elevator doors shall remain fully open in response to a car call for 5 seconds <br />minimum. <br />11B-407.3.6 Width - 11B-407.3.6 Width - The width of elevator doors shall comply with Table 11B-407.4.1. <br />Exception:Exception: In existing elevators, a power-operated car door complying with Section 11B-404.2.3 shall <br />be permitted. <br />11B-407.4 Elevator Car Requirements - 11B-407.4 Elevator Car Requirements - Elevator cars shall comply with Section 11B-407.4. <br />11B-407.4.1 Car Dimensions - 11B-407.4.1 Car Dimensions - Inside dimensions of elevator cars and clear width of elevator doors shall <br />comply with Table 11B-407.4.1. <br />Exception:Exception: In existing buildings, where existing shaft configuration prohibits strict compliance with <br />Section 11B-407.4.1, existing elevator car configurations that provide a clear floor area of 18 square <br />feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a <br />clear width 48 inches (1219 mm) minimum shall be permitted. <br />11B-407.4.2 Floor Surfaces - 11B-407.4.2 Floor Surfaces - Floor surfaces in elevator cars shall comply with Sections 11B-302 and <br />11B-303. <br />11B-407.4.3 Platform to Hoistway Clearance - 11B-407.4.3 Platform to Hoistway Clearance - The clearance between the car platform sill and the edge of <br />any hoistway landing shall be 11/4 inch (32 mm) maximum. <br />11B-407.4.4 Leveling - 11B-407.4.4 Leveling - Each car shall be equipped with a self-leveling feature that will automatically bring <br />and maintain the car at floor landings within a tolerance of 1/2 inch (12.7 mm) under rated loading to zero <br />loading conditions. <br />11B-407.4.5 Illumination - 11B-407.4.5 Illumination - The level of illumination at the car controls, platform, car threshold and car <br />landing sill shall be 5 foot candles (54 lux) minimum. <br />11B-407.4.6 Elevator Car Controls - 11B-407.4.6 Elevator Car Controls - Where provided, elevator car controls shall comply with Sections <br />11B-407.4.6 and 11B-309.4. <br />Exception:Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.6 <br />is provided, existing car operating panels may remain operational and shall not be required to comply <br />with Section 11B-407.4.6. <br />11B-407.4.6.1 Location - 11B-407.4.6.1 Location - Controls shall be located within one of the reach ranges specified in Section <br />11B-308. <br />Exceptions:Exceptions: <br />Where the elevator panel serves more than 16 openings and a parallel approach is provided, <br />buttons with floor designations shall be permitted to be 54 inches (1372 mm) maximum <br />above the finish floor. <br />2.In existing elevators, car control buttons with floor designations shall be permitted to be <br />located 54 inches (1372 mm) maximum above the finish floor where a parallel approach is <br />provided. <br />11B-407.4.6.2 Buttons - 11B-407.4.6.2 Buttons - Car control buttons with floor designations shall comply with Section <br />11B-407.4.6.2. <br />11B-407.4.6.2.1 Size and Shape - 11B-407.4.6.2.1 Size and Shape - Buttons shall have square shoulders, be 3/4 inch (19.1 mm) <br />minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch <br />(0.8 mm) above the surrounding surface. <br />11B-407.4.6.2.2 Arrangement - 11B-407.4.6.2.2 Arrangement - Buttons shall be arranged with numbers in ascending order. <br />When two or more columns of buttons are provided they shall read from left to right. <br />11B-407.4.6.2.3 Illumination - 11B-407.4.6.2.3 Illumination - Car control buttons shall be illuminated. <br />11B-407.4.6.2.4 Operation - 11B-407.4.6.2.4 Operation - Car control buttons shall be activated by a mechanical motion that is <br />detectable. <br />11B-407.4.6.3 Keypads - 11B-407.4.6.3 Keypads - Car control keypads shall be in a standard telephone keypad arrangement <br />and shall comply with Section 11B-407.4.7.2. <br />11B-407.4.6.4 Emergency Controls - 11B-407.4.6.4 Emergency Controls - Emergency controls shall comply with Section 11B-407.4.6.4. <br />11B-407.4.6.4.1 Height - 11B-407.4.6.4.1 Height - Emergency control buttons shall have their centerlines 35 inches (889 <br />mm) minimum above the finish floor. <br />11B-407.4.6.4.2 Location - 11B-407.4.6.4.2 Location - Emergency controls, including the emergency alarm, shall be <br />grouped at the bottom of the panel. <br />11B-407.4.7 Designations and Indicators of Car Controls - 11B-407.4.7 Designations and Indicators of Car Controls - Designations and indicators of car controls <br />shall comply with Section 11B-407.4.7. <br />Exception:Exception: In existing elevators, where a new car operating panel complying with Section 11B-407.4.7 <br />is provided, existing car operating panels may remain operational and shall not be required to comply <br />with Section 11B-407.4.7. <br />11B-407.4.7.1 Buttons - 11B-407.4.7.1 Buttons - Car control buttons shall comply with Section 11B-407.4.7.1. <br />11B-407.4.7.1.1 Type - 11B-407.4.7.1.1 Type - Control buttons shall be identified by raised characters or symbols, white <br />on a black background, complying with Section 11B-703.2 and Braille complying with Section <br />11B-703.3. <br />11B-407.4.7.1.2 Location - 11B-407.4.7.1.2 Location - Raised characters or symbols and Braille designations shall be <br />placed immediately to the left of the control button to which the designations apply. <br />11B-407.4.7.1.3 Symbols - 11B-407.4.7.1.3 Symbols - The control button for the emergency stop, alarm, door open, door <br />close, main entry floor and phone, shall be identified with raised symbols and Braille as shown in <br />Table 11B-407.4.7.1.3. <br />11B-407.4.7.1.4 Visible Indicators - 11B-407.4.7.1.4 Visible Indicators - Buttons with floor designations shall be provided with <br />visible indicators to show that a call has been registered. The visible indication shall extinguish <br />when the car arrives at the designated floor. <br />11B-407.4.7.1.5 Button Spacing - 11B-407.4.7.1.5 Button Spacing - A minimum clear space of 3/8 inch (9.5 mm) or other suitable <br />means of separation shall be provided between rows of control buttons. <br />11B-407.4.7.2 Keypads - 11B-407.4.7.2 Keypads - Keypads shall be identified by characters complying with Section 11B-703.5 <br />and shall be centered on the corresponding keypad button. The number five key shall have a single <br />raised dot. The dot shall be 0.118 inch (3 mm) to 0.120 inch (3.05 mm) base diameter and in other <br />aspects comply with Table 11B-703.3.1. <br />11B-407.4.8 Car Position Indicators - 11B-407.4.8 Car Position Indicators - Audible and visible car position indicators shall be provided in <br />elevator cars. <br />11B-407.4.8.1 Visible Indicators - 11B-407.4.8.1 Visible Indicators - Visible indicators shall comply with Section 11B-407.4.8.1. <br />11B-407.4.8.1.1 Size - 11B-407.4.8.1.1 Size - Characters shall be 1/2 inch (12.7 mm) high minimum. <br />11B-407.4.8.1.2 Location - 11B-407.4.8.1.2 Location - Indicators shall be located above the car control panel or above the <br />door. <br />11B-407.4.8.1.3 Floor Arrival - 11B-407.4.8.1.3 Floor Arrival - As the car passes a floor and when a car stops at a floor served by <br />the elevator, the corresponding character shall illuminate. <br />11B-407.4.8.1.4 Reserved11B-407.4.8.1.4 Reserved <br />11B-407.4.8.2 Audible Indicators - 11B-407.4.8.2 Audible Indicators - Audible indicators shall comply with Section 11B-407.4.8.2. <br />11B-407.4.8.2.1 Signal Type - 11B-407.4.8.2.1 Signal Type - The signal shall be an automatic verbal annunciator which <br />announces the floor at which the car is about to stop. <br />Exception:Exception: For elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non- <br />verbal audible signal with a frequency of 1500 Hz maximum which sounds as the car passes <br />or is about to stop at a floor served by the elevator shall be permitted. <br />11B-407.4.8.2.2 Signal Level - 11B-407.4.8.2.2 Signal Level - The verbal annunciator shall be 10 dB minimum above ambient, <br />but shall not exceed 80 dB, measured at the annunciator. <br />11B-407.4.8.2.3 Frequency - 11B-407.4.8.2.3 Frequency - The verbal annunciator shall have a frequency of 300 Hz minimum <br />to 3000 Hz maximum. <br />11B-407.4.9 Emergency Communication - 11B-407.4.9 Emergency Communication - Emergency two-way communication systems shall comply with <br />Section 11B-308. Raised symbols or characters, white on a black background and Braille shall be provided <br />adjacent to the device and shall comply with Sections 11B-703.2 and 11B-703.3. Emergency two-way <br />communication systems between the elevator and a point outside the hoistway shall comply with ASME <br />A17.1. <br />11B-407.4.10 Support Rail - 11B-407.4.10 Support Rail - Support rails shall be provided on at least one wall of the car. <br />11B-407.4.10.1 Location - 11B-407.4.10.1 Location - Clearance between support rails and adjacent surfaces shall be 11/2 <br />inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches <br />(838 mm) maximum above the floor of the car. The ends of the support rail shall be 6 inches (152 mm) <br />maximum from adjacent walls. <br />11B-407.4.10.2 Surfaces - 11B-407.4.10.2 Surfaces - Support rails shall be smooth and any surface adjacent to them shall be <br />free of sharp or abrasive elements. <br />11B-407.4.10.3 Structural Strength - 11B-407.4.10.3 Structural Strength - Allowable stresses shall not be exceeded for materials used <br />when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, <br />fastener, mounting device or supporting structure. <br />Division 4: Accessible Routes Continued <br />1. <br />2. <br />11B-502.3.4 Location - 11B-502.3.4 Location - Access aisles shall not overlap the vehicular way. Access aisles shall be permitted to be <br />placed on either side of the parking space except for van parking spaces which shall have access aisles located <br />on the passenger side of the parking spaces. <br />11B-502.4 Floor or Ground Surfaces - 11B-502.4 Floor or Ground Surfaces - Parking spaces and access aisles serving them shall comply with <br />Section 11B-302. Access aisles shall be at the same level as the parking spaces they serve. Changes in level, <br />slopes exceeding 1:48, and detectable warnings shall not be permitted. <br />11B-502.5 Vertical Clearance - 11B-502.5 Vertical Clearance - Parking spaces, access aisles and vehicular routes serving them shall provide a <br />vertical clearance of 98 inches (2489 mm) minimum. <br />Exception:Exception: In existing multistory parking facilities, car parking spaces, access aisles and vehicular routes <br />serving them shall provide a vertical clearance of 80 inches (2032 mm) minimum. Existing vertical clearance <br />in excess of 80 inches (2032 mm) and less than 98 inches (2489 mm) shall be maintained. This exception <br />shall not apply to van parking spaces, access aisles or vehicular routes serving them. <br />11B-502.6 Identification - 11B-502.6 Identification - Parking space identification signs shall include the International Symbol of <br />Accessibility complying with Section 11B-703.7.2.1 in white on a blue background. Signs identifying van parking <br />spaces shall contain additional language or an additional sign with the designation "van accessible". Signs shall <br />be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. <br />Exception:Exception: Signs located within a circulation path shall be a minimum of 80 inches (2032 mm) above the <br />finish floor or ground surface measured to the bottom of the sign. <br />11B-502.6.1 Finish and Size - 11B-502.6.1 Finish and Size - Parking identification signs shall be reflectorized with a minimum area of 70 <br />square inches (45,161 mm2). <br />11B-502.6.2 Minimum Fine - 11B-502.6.2 Minimum Fine - Additional language or an additional sign below the International Symbol of <br />Accessibility shall state "Minimum Fine $250". <br />11B-502.6.3 Location - 11B-502.6.3 Location - A parking space identification sign shall be visible from each parking space. Signs <br />shall be permanently posted either immediately adjacent to the parking space or within the projected parking <br />space width at the head end of the parking space. Signs may also be permanently posted on a wall at the <br />interior end of the parking space. <br />11B-502.6.4 Marking - 11B-502.6.4 Marking - Each accessible car and van space shall have surface identification complying with <br />either Section 11B-502.6.4.1 or 11B-502.6.4.2. <br />11B-502.6.4.1 - 11B-502.6.4.1 - The parking space shall be marked with an International Symbol of Accessibility <br />complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 <br />inches high (914 mm by 914 mm). The centerline of the International Symbol of Accessibility shall be a <br />maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length <br />of the parking space and its lower corner at, or lower side aligned with, the end of the parking space <br />length. <br />11B-502.6.4.2 - 11B-502.6.4.2 - The parking space shall be outlined in blue or painted blue and shall be marked with <br />an International Symbol of Accessibility complying with Section 11B-703.7.2.1 a minimum 36 inches <br />wide by 36 inches high (914 mm by 914 mm) in white or a suitable contrasting color. The centerline of <br />the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline <br />of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower <br />side aligned with, the end of the parking space. <br />11B-502.7 Relationship to Accessible Routes - 11B-502.7 Relationship to Accessible Routes - Parking spaces and access aisles shall be designed so that <br />cars and vans, when parked, cannot obstruct the required clear width of adjacent accessible routes. <br />11B-502.7.1 Arrangement - 11B-502.7.1 Arrangement - Parking spaces and access aisles shall be designed so that persons using <br />them are not required to travel behind parking spaces other than to pass behind the parking space in <br />which they parked. <br />11B-502.7.2 Wheel Stops - 11B-502.7.2 Wheel Stops - A curb or wheel stop shall be provided if required to prevent <br />encroachment of vehicles over the required clear width of adjacent accessible routes. <br />11B-502.8 Additional Signs - 11B-502.8 Additional Signs - An additional sign shall be posted either; 1) in a conspicuous place at each <br />entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible <br />from each parking space. <br />11B-502.8.1 Size - 11B-502.8.1 Size - The additional sign shall not be less than 17 inches (432 mm) wide by 22 inches <br />(559 mm) high. <br />11B-502.8.2 Lettering - 11B-502.8.2 Lettering - The additional sign shall clearly state in letters with a minimum height of 1 inch <br />(25 mm) the following: <br />"Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or <br />special license plates issued for persons with disabilities will be towed away at the owner's expense. <br />Towed vehicles may be reclaimed at: _________________________ or by telephoning <br />_______________________." <br />Blank spaces shall be filled in with appropriate information as a permanent part of the sign. <br />11B-503 Passenger Drop-Off and Loading Zones11B-503 Passenger Drop-Off and Loading Zones <br />11B-503.1 General - 11B-503.1 General - Passenger drop-off and loading zones shall comply with Section 11B-503. <br />11B-503.2 Vehicle Pull-Up Space - 11B-503.2 Vehicle Pull-Up Space - Passenger drop-off and loading zones shall provide a vehicular pull-up <br />space 96 inches (2438 mm) wide minimum and 20 feet (6096 mm) long minimum. <br />11B-503.3 Access Aisle - 11B-503.3 Access Aisle - Passenger drop-off and loading zones shall provide access aisles complying with <br />Section 11B-503 adjacent and parallel to the vehicle pull-up space. Access aisles shall adjoin an accessible <br />route and shall not overlap the vehicular way. <br />11B-503.3.1 Width - 11B-503.3.1 Width - Access aisles serving vehicle pull-up spaces shall be 60 inches (1524 mm) wide <br />minimum. <br />11B-503.3.2 Length - 11B-503.3.2 Length - Access aisles shall extend the full length of the vehicle pull-up spaces they serve. <br />11B-503.3.3 Marking - 11B-503.3.3 Marking - Access aisles shall be marked with a painted borderline around their perimeter. The <br />area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center <br />in a color contrasting with that of the aisle surface. <br />11B-503.4 Floor and Ground Surfaces - 11B-503.4 Floor and Ground Surfaces - Vehicle pull-up spaces and access aisles serving them shall comply <br />with Section 11B-302. Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes <br />in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. <br />11B-503.5 Vertical Clearance - 11B-503.5 Vertical Clearance - Vehicle pull-up spaces, access aisles serving them and a vehicular route from <br />an entrance to the passenger drop-off and loading zone and from the passenger drop-off and loading zone to a <br />vehicular exit shall provide a vertical clearance of 114 inches (2896 mm) minimum. <br />11B-504 Stairways11B-504 Stairways <br />11B-504.1 General - 11B-504.1 General - Stairs shall comply with Section 11B-504. <br />11B-504.2 Treads and Risers - 11B-504.2 Treads and Risers - All steps on a flight of stairs shall have uniform riser heights and uniform tread <br />depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum. Treads shall <br />be 11 inches (279 mm) deep minimum. <br />Exception:Exception: Curved stairways with winder treads are permitted at stairs which are not part of a required means <br />of egress. <br />11B-504.3 Open Risers - 11B-504.3 Open Risers - Open risers are not permitted. <br />Exceptions:Exceptions: <br />On exterior stairways, an opening of not more than 1/2 inch (12.7 mm) may be permitted between <br />the base of the riser and the tread. <br />On exterior stairways, risers constructed of grating containing openings of not more than 1/2 inch <br />(12.7 mm) may be permitted. <br />11B-504.4 Tread Surface - 11B-504.4 Tread Surface - Stair treads shall comply with Section 11B-302. Changes in level, slopes exceeding <br />1:48, and detectable warnings shall not be permitted. <br />11B-504.4.1 Contrasting Stripe - 11B-504.4.1 Contrasting Stripe - Interior stairs shall have the upper approach and lower tread marked by a <br />stripe providing clear visual contrast. Exterior stairs shall have the upper approach and all treads marked by a <br />stripe providing clear visual contrast. <br />The stripe shall be a minimum of 2 inches (51 mm) wide to a maximum of 4 inches (102 mm) wide placed <br />parallel to, and not more than 1 inch (25 mm) from, the nose of the step or upper approach. The stripe shall <br />extend the full width of the step or upper approach and shall be of material that is at least as slip resistant as <br />the other treads of the stair. A painted stripe shall be acceptable. Grooves shall not be used to satisfy this <br />requirement. <br />11B-504.5 Nosings - 11B-504.5 Nosings - The radius of curvature at the leading edge of the tread shall be 1/2 inch (12.7 mm) <br />maximum. Nosings that project beyond risers shall have the underside of the leading edge curved or beveled. <br />Risers shall be permitted to slope under the tread at an angle of 30 degrees maximum from vertical. The permitted <br />projection of the nosing shall extend 11/4 inches (32 mm) maximum over the tread below. <br />Exception:Exception: In existing buildings there is no requirement to retroactively alter existing nosing projections of <br />11/2 inches (38 mm) which were constructed in compliance with the building code in effect at the time of <br />original construction. <br />11B-504.6 Handrails - 11B-504.6 Handrails - Stairs shall have handrails complying with Section 11B-505. <br />11B-504.7 Wet Conditions - 11B-504.7 Wet Conditions - Stair treads and landings subject to wet conditions shall be designed to prevent the <br />accumulation of water. <br />1. <br />2. <br />3. <br />1. <br />2. <br />1. <br />2. <br />3. <br />11B-504.8 Floor Identification - 11B-504.8 Floor Identification - Floor identification signs required by Chapter 10, Section 1023.9 complying <br />with Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor <br />level, placed adjacent to the door on the latch side, in all enclosed stairways in buildings two or more stories in <br />height to identify the floor level. At the exit discharge level, the sign shall include a raised five pointed star located <br />to the left of the identifying floor level. The outside diameter of the star shall be the same as the height of the <br />raised characters. <br />11B-505 Handrails11B-505 Handrails <br />11B-505.1 General - 11B-505.1 General - Handrails provided along walking surfaces complying with Section 11B-403, required at <br />ramps complying with Section 11B-405, and required at stairs complying with Section 11B-504 shall comply <br />with Section 11B-505. <br />11B-505.2 Where Required - 11B-505.2 Where Required - Handrails shall be provided on both sides of stairs and ramps. <br />Exceptions:Exceptions: <br />In assembly areas, handrails shall not be required on both sides of aisle ramps where a handrail is <br />provided at either side or within the aisle width. <br />Curb ramps do not require handrails. <br />At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in <br />rise or 72 inches (1829 mm) in length. <br />11B-505.2.1 Orientation - 11B-505.2.1 Orientation - The orientation of at least one handrail shall be in the direction of the stair run, <br />perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of the <br />stair. <br />11B-505.3 Continuity - 11B-505.3 Continuity - Handrails shall be continuous within the full length of each stair flight or ramp run. <br />Inside handrails on switchback or dogleg stairs and ramps shall be continuous between flights or runs. <br />Exception:Exception: In assembly areas, ramp handrails adjacent to seating or within the aisle width shall not be <br />required to be continuous in aisles serving seating. <br />11B-505.4 Height - 11B-505.4 Height - Top of gripping surfaces of handrails shall be 34 inches (864 mm) minimum and 38 inches <br />(965 mm) maximum vertically above walking surfaces, stair nosings and ramp surfaces. Handrails shall be at a <br />consistent height above walking surfaces, stair nosings and ramp surfaces. <br />11B-505.5 Clearance - 11B-505.5 Clearance - Clearance between handrail gripping surfaces and adjacent surfaces shall be 11/2 inches <br />(38 mm) minimum. Handrails may be located in a recess if the recess is 3 inches (76 mm) maximum deep and <br />18 inches (457 mm) minimum clear above the top of the handrail. <br />11B-505.6 Gripping Surface - 11B-505.6 Gripping Surface - Handrail gripping surfaces shall be continuous along their length and shall not be <br />obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be obstructed for more <br />than 20 percent of their length. Where provided, horizontal projections shall occur 11/2 inches (38 mm) <br />minimum below the bottom of the handrail gripping surface. <br />Exceptions:Exceptions: <br />Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the <br />bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length <br />where they are integral to crash rails or bumper guards. <br />The distance between horizontal projections and the bottom of the gripping surface shall be <br />permitted to be reduced by 1/8 inch (3.2 mm) for each 1/2 inch (12.7 mm) of additional handrail <br />perimeter dimension that exceeds 4 inches (102 mm). <br />11B-505.7 Cross Section - 11B-505.7 Cross Section - Handrail gripping surfaces shall have a cross section complying with Section <br />11B-505.7.1 or 11B-505.7.2. <br />11B-505.7.1 Circular Cross Section - 11B-505.7.1 Circular Cross Section - Handrail gripping surfaces with a circular cross section shall have an <br />outside diameter of 11/4 inches (32 mm) minimum and 2 inches (51 mm) maximum. <br />11B-505.7.2 Non-Circular Cross Sections - 11B-505.7.2 Non-Circular Cross Sections - Handrail gripping surfaces with a non-circular cross section <br />shall have a perimeter dimension of 4 inches (102 mm) minimum and 61/4 inches (159 mm) maximum, <br />and a cross-section dimension of 21/4 inches (57 mm) maximum. <br />11B-505.8 Surfaces - 11B-505.8 Surfaces - Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or <br />abrasive elements and shall have rounded edges. <br />11B-505.9 Fittings -11B-505.9 Fittings -Handrails shall not rotate within their fittings. <br />11B-505.10 Handrail Extensions - 11B-505.10 Handrail Extensions - Handrail gripping surfaces shall extend beyond and in the same direction of <br />stair flights and ramp runs in accordance with Section 11B-505.10. <br />Exceptions:Exceptions: <br />Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg <br />stairs and ramps. <br />In assembly areas, extensions shall not be required for ramp handrails in aisles serving seating <br />where the handrails are discontinuous to provide access to seating and to permit crossovers within <br />aisles. <br />In alterations, where the extension of the handrail in the direction of stair flight or ramp run would <br />create a hazard, the extension of the handrail may be turned 90 degrees from the direction of stair <br />flight or ramp run. <br />11B-505.10.1 Top and Bottom Extension at Ramps - 11B-505.10.1 Top and Bottom Extension at Ramps - Ramp handrails shall extend horizontally above the <br />landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs. Extensions shall return <br />to a wall, guard or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. <br />11B-505.10.2 Top Extension at Stairs - 11B-505.10.2 Top Extension at Stairs - At the top of a stair flight, handrails shall extend horizontally above <br />the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing. Extensions <br />shall return to a wall, guard or the landing surface, or shall be continuous to the handrail of an adjacent stair <br />flight. <br />11B-505.10.3 Bottom Extension at Stairs - 11B-505.10.3 Bottom Extension at Stairs - At the bottom of a stair flight, handrails shall extend at the <br />slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing. The <br />horizontal extension of a handrail shall be 12 inches (305 mm) long minimum and a height equal to that of <br />the sloping portion of the handrail as measured above the stair nosings. Extension shall return to a wall, <br />guard or the landing surface, or shall be continuous to the handrail of an adjacent stair flight. <br />1. <br />2. <br />3. <br />1. <br />2. <br />3. <br />1. <br />2. <br />3. <br />1. <br />2. <br />11B-603.2 Clearances - 11B-603.2 Clearances - Clearances shall comply with Section 11B-603.2. <br />11B-603.2.1 Turning Space - 11B-603.2.1 Turning Space - Turning space complying with Section 11B-304 shall be provided within the <br />room. <br />11B-603.2.2 Overlap - 11B-603.2.2 Overlap - Required clear floor spaces, clearance at fixtures and turning space shall be <br />permitted to overlap. <br />11B-603.2.3 Door Swing - 11B-603.2.3 Door Swing - Doors shall not swing into the clear floor space or clearance required for any <br />fixture. Doors to accessible water closet compartments shall be permitted to encroach into the turning space <br />without limitation. Other than doors to accessible water closet compartments, a door, in any position, shall <br />be permitted to encroach into the turning space by 12 inches (305 mm) maximum. <br />Exceptions:Exceptions: <br />Reserved. <br />Where the toilet room or bathing room is for individual use and a clear floor space complying <br />with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors <br />shall be permitted to swing into the clear floor space or clearance required for any fixture. <br />In residential dwelling units complying with Section 11B-233.3.1.1, doors shall be permitted <br />to swing over the turning space without limitation. <br />11B-603.3 Mirrors - 11B-603.3 Mirrors - Mirrors located above lavatories or countertops shall be installed with the bottom edge of <br />the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground. Mirrors not located above <br />lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (889 mm) <br />maximum above the finish floor or ground. <br />11B-603.4 Coat Hooks, Shelves and Medicine Cabinets - 11B-603.4 Coat Hooks, Shelves and Medicine Cabinets - Coat hooks shall be located within one of the reach <br />ranges specified in Section 11B-308. Shelves shall be located 40 inches (1016 mm) minimum and 48 inches <br />(1219 mm) maximum above the finish floor. Medicine cabinets shall be located with a usable shelf no higher <br />than 44 inches (1118 mm) maximum above the finish floor. <br />11B-603.5 Accessories - 11B-603.5 Accessories - Where towel or sanitary napkin dispensers, waste receptacles or other accessories are <br />provided in toilet facilities, at least one of each type shall be located on an accessible route. All operable parts, <br />including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor. <br />Exception:Exception: Baby diaper changing stations are not required to comply with Section 11B-603.5. <br />11B-603.6 Guest Room Toilet and Bathing Rooms - 11B-603.6 Guest Room Toilet and Bathing Rooms - Toilet and bathing rooms within guest rooms that are not <br />required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing <br />fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by <br />1219 mm) to touch the wheelchair to any lavatory, urinal, water closet, tub, sauna, shower stall and any other <br />similar sanitary installation, if provided. <br />11B-604 Water Closets and Toilet Compartments11B-604 Water Closets and Toilet Compartments <br />11B-604.1 General - 11B-604.1 General - Water closets and toilet compartments shall comply with Sections 11B-604.2 through <br />11B-604.8. <br />Exception:Exception: Water closets and toilet compartments for children's use shall be permitted to comply with <br />Section 11B-604.9. <br />11B-604.2 Location - 11B-604.2 Location - The water closet shall be positioned with a wall or partition to the rear and to one side. The <br />center-line of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from the <br />side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 <br />mm) maximum from the side wall or partition in the ambulatory accessible toilet compartment specified in <br />Section 11B-604.8.2. Water closets shall be arranged for a left-hand or right-hand approach. <br />11B-604.3 Clearance - 11B-604.3 Clearance - Clearances around water closets and in toilet compartments shall comply with Section <br />11B-604.3. <br />11B-604.3.1 Size - 11B-604.3.1 Size - Clearance around a water closet shall be 60 inches (1524 mm) minimum measured <br />perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear <br />wall. A minimum 60 inches (1524 mm) wide and 48 inches (1219 mm) deep maneuvering space shall be <br />provided in front of the water closet. <br />Exception:Exception: In residential dwelling units complying with Section 11B-233.3.1.1, maneuvering space in <br />front of the water closet shall be a minimum 60 inches (1524 mm) wide and 36 inches (914 mm) deep. <br />11B-604.3.2 Overlap - 11B-604.3.2 Overlap - The required clearance around the water closet shall be permitted to overlap the <br />water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, <br />accessible routes, clear floor space and clearances required at other fixtures and the turning space. No other <br />fixtures or obstructions shall be located within the required water closet clearance. <br />Exception:Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted <br />on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow for the <br />installation of a grab bar where the clearance at the water closet is 66 inches (1676 mm) minimum <br />measured perpendicular from the rear wall. <br />11B-604.4 Seats - 11B-604.4 Seats - The seat height of a water closet above the finish floor shall be 17 inches (432 mm) <br />minimum and 19 inches (483 mm) maximum measured to the top of the seat. Seats shall not be sprung to return <br />to a lifted position. Seats shall be 2 inches (51 mm) high maximum. <br />Exceptions:Exceptions: <br />Reserved. <br />In residential dwelling units, the height of water closets shall be permitted to be 15 inches (381 <br />mm) minimum and 19 inches (483 mm) maximum above the finish floor measured to the top of <br />the seat. <br />A 3-inch (76 mm) high seat shall be permitted only in alterations where the existing fixture is less <br />than 15 inches (381 mm) high. <br />11B-604.5 Grab Bars - 11B-604.5 Grab Bars - Grab bars for water closets shall comply with Section 11B-609. Grab bars shall be <br />provided on the side wall closest to the water closet and on the rear wall. Where separate grab bars are required <br />on adjacent walls at a common mounting height, an L-shaped grab bar meeting the dimensional requirements of <br />Sections 11B-604.5.1 and 11B- 604.5.2 shall be permitted. <br />Exceptions:Exceptions: <br />Reserved. <br />In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms <br />provided that reinforcement has been installed in walls and located so as to permit the installation <br />of grab bars complying with Section 11B-604.5. <br />In detention or correction facilities, grab bars shall not be required to be installed in housing or <br />holding cells that are specially designed without protrusions for purposes of suicide prevention. <br />11B-604.5.1 Side Wall - 11B-604.5.1 Side Wall - The side wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 <br />inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear <br />wall with the front end positioned 24 inches (610 mm) minimum in front of the water closet. <br />11B-604.5.2 Rear Wall - 11B-604.5.2 Rear Wall - The rear wall grab bar shall be 36 inches (914 mm) long minimum and extend <br />from the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) <br />minimum on the other side. <br />Exceptions:Exceptions: <br />The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on <br />the water closet, where wall space does not permit a length of 36 inches (914 mm) minimum <br />due to the location of a recessed fixture adjacent to the water closet. <br />Where an administrative authority requires flush controls for flush valves to be located in a <br />position that conflicts with the location of the rear grab bar, then the rear grab bar shall be <br />permitted to be split or shifted to the open side of the toilet area. <br />11B-604.6 Flush Controls - 11B-604.6 Flush Controls - Flush controls shall be hand operated or automatic. Hand operated flush controls <br />shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor. <br />Flush controls shall be located on the open side of the water closet except in ambulatory accessible <br />compartments complying with Section 11B-604.8.2. <br />11B-604.7 Dispensers and Disposal Units - 11B-604.7 Dispensers and Disposal Units - Toilet paper dispensers and sanitary napkin disposal units shall <br />comply with Section 11B-604.7. Combination accessory units are not permitted to encroach into the space <br />required by Section 11B-609.3. <br />11B-604.7.1 Dispensers - 11B-604.7.1 Dispensers - Toilet paper dispensers shall comply with Section 11B-309.4 and shall be 7 <br />inches (178 mm) minimum and 9 inches (229 mm) maximum in front of the water closet measured to the <br />centerline of the dispenser. The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) <br />minimum above the finish floor and shall not be located behind grab bars. Dispensers shall not be of a type <br />that controls delivery or that does not allow continuous paper flow. <br />11B-604.7.2 Disposal Units - 11B-604.7.2 Disposal Units - Sanitary napkin disposal units, if provided, shall comply with Section <br />11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the <br />toilet paper dispenser, adjacent to the toilet paper dispenser. The disposal unit shall be located below the <br />grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor. <br />11B-604.8 Toilet Compartments - 11B-604.8 Toilet Compartments - Wheelchair accessible toilet compartments shall meet the requirements of <br />Sections 11B-604.8.1 and 11B-604.8.3. Compartments containing more than one plumbing fixture shall comply <br />with Section 11B-603. Ambulatory accessible compartments shall comply with Sections 11B-604.8.2 and <br />11B-604.8.3. <br />11B-604.8.1 Wheelchair Accessible Compartments - 11B-604.8.1 Wheelchair Accessible Compartments - Wheelchair accessible compartments shall comply <br />with Section 11B-604.8.1. <br />11B-604.8.1.1 Size - 11B-604.8.1.1 Size - Wheelchair accessible compartments shall be 60 inches (1524 mm) wide <br />minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall <br />hung water closets and 59 inches (1499 mm) deep minimum for floor mounted water closets measured <br />perpendicular to the rear wall. Wheelchair accessible compartments shall additionally provide <br />maneuvering space complying with Section 11B-604.8.1.1.1, 11B-604.8.1.1.2 or 11B-604.8.1.1.3, as <br />applicable. Wheelchair accessible compartments for children's use shall be 60 inches (1524 mm) wide <br />minimum measured perpendicular to the side wall, and 59 inches (1499 mm) deep minimum for wall <br />hung and floor mounted water closets measured perpendicular to the rear wall. <br />Division 5: General Site and Building Elements <br />11B-501 General11B-501 General <br />11B-501.1 Scope - 11B-501.1 Scope - The provisions of Division 5 shall apply where required by Division 2 or where referenced by <br />a requirement in this chapter. <br />11B-502 Parking Spaces11B-502 Parking Spaces <br />11B-502.1 General - 11B-502.1 General - Car and van parking spaces shall comply with Section 11B-502. Where parking spaces are <br />marked with lines, width measurements of parking spaces and access aisles shall be made from the centerline of <br />the markings. <br />Exception:Exception: Where parking spaces or access aisles are not adjacent to another parking space or access aisle, <br />measurements shall be permitted to include the full width of the line defining the parking space or access <br />aisle. <br />11B-502.2 Vehicle Spaces - 11B-502.2 Vehicle Spaces - Car and van parking spaces shall be 216 inches (5486 mm) long minimum. Car <br />parking spaces shall be 108 inches (2743 mm) wide minimum and van parking spaces shall be 144 inches <br />(3658 mm) wide minimum, shall be marked to define the width, and shall have an adjacent access aisle <br />complying with Section 11B-502.3. <br />Exception:Exception: Van parking spaces shall be permitted to be 108 inches (2743 mm) wide minimum where the <br />access aisle is 96 inches (2438 mm) wide minimum. <br />11B-502.3 Access Aisle - 11B-502.3 Access Aisle - Access aisles serving parking spaces shall comply with Section 11B-502.3. Access <br />aisles shall adjoin an accessible route. Two parking spaces or one parking space and one electric vehicle <br />charging space shall be permitted to share a common access aisle. <br />11B-502.3.1 Width - 11B-502.3.1 Width - Access aisles serving car and van parking spaces shall be 60 inches (1524 mm) wide <br />minimum. <br />11B-502.3.2 Length - 11B-502.3.2 Length - Access aisles shall extend the full required length of the parking spaces they serve. <br />11B-502.3.3 Marking - 11B-502.3.3 Marking - Access aisles shall be marked with a blue painted borderline around their perimeter. <br />The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) <br />on center in a color contrasting with that of the aisle surface, preferably blue or white. The words "NO <br />PARKING" shall be painted on the surface within each access aisle in white letters a minimum of 12 inches <br />(305 mm) in height and located to be visible from the adjacent vehicular way. Access aisle markings may <br />extend beyond the minimum required length. <br />Division 6: Plumbing Elements and Facilities <br />11B-601 General11B-601 General <br />11B-601.1 Scope - 11B-601.1 Scope - The provisions of Division 6 shall apply where required by Division 2 or where referenced by <br />a requirement in this chapter. <br />11B-602 Drinking Fountains and Bottle-Filling Stations11B-602 Drinking Fountains and Bottle-Filling Stations <br />11B-602.1 General - 11B-602.1 General - Drinking fountains shall comply with Sections 11B-307 and 11B-602. <br />11B-602.2 Clear Floor Space - 11B-602.2 Clear Floor Space - Units shall have a clear floor or ground space complying with Section 11B-305 <br />positioned for a forward approach and centered on the unit. Knee and toe clearance complying with Section <br />11B-306 shall be provided. <br />Exception:Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use <br />where the spout is 30 inches (762 mm) maximum above the finish floor or ground and is 31/2 inches (89 <br />mm) maximum from the front edge of the unit, including bumpers. <br />11B-602.3 Operable Parts - 11B-602.3 Operable Parts - Operable parts shall comply with Section 11B-309. The flow of water shall be <br />activated by a manually operated system that is front mounted or side mounted and located within 6 inches (152 <br />mm) of the front edge of the fountain or an automatic electronically controlled device. <br />11B-602.4 Spout Height - 11B-602.4 Spout Height - Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or <br />ground. <br />11B-602.5 Spout Location - 11B-602.5 Spout Location - The spout shall be located 15 inches (381 mm) minimum from the vertical support <br />and 5 inches (127 mm) maximum from the front edge of the unit, including bumpers. <br />11B-602.6 Water Flow - 11B-602.6 Water Flow - The spout shall provide a flow of water 4 inches (102 mm) high minimum and shall be <br />located 5 inches (127 mm) maximum from the front of the unit. The angle of the water stream shall be measured <br />horizontally relative to the front face of the unit. Where spouts are located less than 3 inches (76 mm) of the front <br />of the unit, the angle of the water stream shall be 30 degrees maximum. Where spouts are located between 3 <br />inches (76 mm) and 5 inches (127 mm) maximum from the front of the unit, the angle of the water stream shall <br />be 15 degrees maximum. <br />11B-602.7 Drinking Fountains for Standing Persons - 11B-602.7 Drinking Fountains for Standing Persons - Spout outlets of drinking fountains for standing persons <br />shall be 38 inches (965 mm) minimum and 43 inches (1092 mm) maximum above the finish floor or ground. <br />11B-602.8 Depth - 11B-602.8 Depth - Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) <br />minimum and 19 inches (483 mm) maximum in depth. <br />11B-602.9 Pedestrian Protection -11B-602.9 Pedestrian Protection -All drinking fountains shall either be located completely within alcoves, <br />positioned completely between wing walls, or otherwise positioned so as not to encroach into pedestrian ways. <br />The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and <br />18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7. When used, wing walls or <br />barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically <br />from the floor or ground surface. <br />11B-602.10 Bottle-Filling Stations - 11B-602.10 Bottle-Filling Stations - Bottle-filling stations shall comply with Sections 11B-307 and 11B-309. <br />Exception: Where bottle-filling stations are provided at a drinking fountain for standing persons, the bottle-filling <br />station is not required to comply with this section provided a bottle-filling station is located at the drinking <br />fountain complying with Sections 11B-602.2 through 11B-602.6. <br />11B-603 Toilet and Bathing Rooms11B-603 Toilet and Bathing Rooms <br />11B-603.1 General - 11B-603.1 General - Toilet and bathing rooms shall comply with Section 11B-603. <br />No.Revisions Date <br />1 SD Set 06/05/2025 <br />2 DD Set 07/03/2025 <br />3 90% CD Set 08/14/2025 <br />4 Plan Check Submittal 09/19/2025 <br />09-2027