My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
301 N Broadway - Shell & Core - Plan (2)
PBA
>
Building
>
ProjectDox
>
B
>
Broadway
>
301 N Broadway
>
301 N Broadway - Shell & Core - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2026 5:01:29 AM
Creation date
3/10/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20183592
30147601
40139376
101120309
Full Address
301 N Broadway
Street Number
301
Street Direction
N
Street Name
Broadway
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2081
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1/2" X 1-1/2" 16 GA <br />GALV. CRC SECURED <br />TO CARRIER WITH <br />12 GA GALV. <br />BRACKET, NOT BY <br />CERTAINTEED <br />1/2" X 1-1/2" 16 GA <br />GALV. CRC <br />CLARKDIETRICH 250PDS125-33 <br />(2-1/2” PROSTUD 33) <br />OR <br />OR <br />BEND DOWN CARRIER TABS TO <br />SECURE PANELS AT ALL PANEL/ <br />CARRIER INTERSECTIONS, TYP. <br />300C CARRIER <br />300C PANEL <br />12 GA HANGER WIRE WITHIN 3" <br />OF VERTICAL SUPPORT, BY <br />OTHERS, TYP. <br />REFER TO RCP <br />09 22 16.C05 <br />GRID SUSPENSION SYSTEM <br />09 29 00.B05 <br />SAG-RESIS GYP BD <br />09 29 00.J05 <br />CONTROL JOINT <br />ALIGN <br />1/4" <br />09 22 16.C02 <br />HANGER <br />SCHEDULED ACOUSTICAL <br />DRYWALL CEILING WITH <br />SPRAY-APPLIED FINISH <br />NOTE: PROVIDE CONTROL JOINTS AT CEILINGS THAT EXCEEDS 30 FEET WITHOUT PERIMETER <br />RELIEF OR EXCEED 50 FEET WITH PERIMETER RELIEF. COORDINATE LOCATION WITH ARCHTECT <br />09 51 13.C02 <br />2" X 2" ANGLE MOLDING <br />09 29 00.B05 <br />SAG-RESIS GYP BD <br />09 29 00.J10 <br />J-BEAD <br />VA <br />R <br />I <br />E <br />S <br />09 22 16.C01 <br />WIRE TIE <br />09 51 13.B00 <br />SUSPENSION SYSTEM <br />SCHEDULED OR EXISTING <br />PARTITION <br />VARIES <br />MIN. <br />XXX <br />REFER TO RCP <br />RETURN AIR SLOT; REFER <br />TO ENGINEERING DRAWINGS <br />METAL ANGLE TO BE <br />PAINTED MATTE BLACK <br />SCHEDULED ACOUSTICAL <br />DRYWALL CEILING WITH <br />SPRAY-APPLIED FINISH <br />VARIES <br />CHANNEL BRIDGING <br />09 22 16.A09 <br />2" <br />SAG-RESIS GYP BD <br />09 29 00.B05 <br />? <br /> 09 2 00.J10 <br />CHANNEL BRIDGING <br />09 22 16.A09 <br />XX REFER TO CONSTRUCTION PLAN <br />SAG-RESIS GYP BD <br />09 29 00.B05 <br />DIRECT HANGING CLIP <br />09 51 13.K01 <br />FURRING CHANNEL CLIP <br />09 22 16.C08 <br />FURRING CHANNEL <br />09 22 16.C04 <br />COLD-ROLLED CHANNEL <br />09 22 16.B03 <br />HANGER ROD <br />09 51 13.G01 <br />VARIES <br />XX REFER TO CONSTRUCTION PLAN <br />8" <br />ALIG <br />N <br />METAL STUD <br />09 22 16.A00 <br />METAL RUNNER TRACK <br />09 22 16.A01 <br />JOINT REINFORCEMENT <br />09 29 00.J09 <br />GYP BD 5/8" <br />09 29 00.A01 <br />GYP BD 5/8" <br />09 29 00.A01 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />ACOUSTICAL PANEL CEILING <br />09 51 13.A00 <br />EDGE MOLDING <br />09 51 13.C00 <br />CORNER BEAD <br />09 29 00.J01 <br />6" <br />ALIG <br />N <br />CHANNEL BRIDGING <br />09 22 16.A09 <br />SUSPENSION SYSTEM <br />09 51 13.B00 <br />ACOUSTICAL PANEL CEILING <br />09 51 13.A00 <br />EDGE MOLDING <br />09 51 13.C00 <br />CORNER BEAD <br />09 29 00.J01 <br />SAG-RESIS GYP BD <br />09 29 00.B05 <br />HANGER ROD <br />09 51 13.G01 <br />03 <br />1" USG SHEETROCK BRAND GYPSUM LINER PANELS <br />5/8" USG SHEETROCK BRAND FIRECODE PANELS OR <br />5/8" USG SHEETROCK BRAND ULTRALIGHT PANELS <br />FIRECODE X <br />CORNER BEAD <br />5/8" USG SHEETROCK BRAND FIRECODE C PANELS <br />RC-1 RESILIENT CHANNELS 16" 0.C <br />PERIMETER CHANNEL <br />STEEL STRAP <br />STEEL STUDS <br />DUCT, REFER TO MECHANICAL <br />REFER TO CONSTRUCTION PLANS <br />09 29 00.B00 <br />09 29 00.B00 <br />09 29 00.J01 <br />09 22 16.A01 <br />09 22 16.A01 <br />PROVIDE A 48"x48" ACCESS PANEL UNDER FAN FOR <br />ACCESS AND SERVICE, FINAL LOCATION TO BE <br />DETERMINED IN FIELD. <br />5/8" GYP BD SOFFIT ON <br />3-5/8" 20 GA METAL STUD <br />FRAMING AT 16" O.C. (TYP.) <br />UNDERSIDE OF EXPOSED <br />PAINTED PS FLOOR SLAB <br />WHERE IT OCCURS <br />LINEAR LIGHT FIXTURE <br />WHERE IT OCCURS - <br />REFER TO ELEC'L. DWGS. <br />REINFORCED CORNER <br />BEAD AT CORNER <br />EDGES (TYP.) <br />REFER TO RCP <br />RE <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />R <br />C <br />P <br />9" MIN. <br />AT RESI HALLWAYS/UNITS <br />8" <br /> <br />H <br />O <br />L <br />D <br />REFER TO RCP <br />CONT. SEALANT (TYP.) <br />CONT. 2 1/2" METAL <br />STUD LEDGE ON TOP <br />OF 3 5/8" METAL <br />STUD AT 16" O.C. <br />5/8" GYP BD SOFFIT ON <br />3-5/8" 20 GA METAL STUD <br />FRAMING AT 16" O.C. (TYP.) <br />UNDERSIDE OF EXPOSED <br />PAINTED PS FLOOR SLAB <br />WHERE IT OCCURS <br />LINEAR LIGHT FIXTURE <br />WHERE IT OCCURS - <br />REFER TO ELEC'L. DWGS. <br />REINFORCED CORNER <br />BEAD AT CORNER <br />EDGES (TYP.) <br />REFER TO RCP <br />RE <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />R <br />C <br />P <br />9" MIN. <br />RE <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />E <br />L <br />E <br />V <br />. <br /> <br />R <br />E <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />E <br />L <br />E <br />V <br />. <br />REFER TO RCP <br />CONT. SEALANT (TYP.) <br />CONT. 2 1/2" METAL <br />STUD LEDGE ON TOP <br />OF 3 5/8" METAL <br />STUD AT 16" O.C. <br />ACOUSTICAL CEILING <br />SYSTEM <br />LIGHT FIXTURE REFER <br />TO ELECT'L. DWGS. <br />FACE OF STRUCTURE <br />WALL <br />5/8" THK. TYPE 'X' <br />GYP. BD. ON 2 1/2" <br />METAL STUDS AT <br />16" O.C. <br />CONT. SEALANT <br />FINISHED CEILING <br />WHERE OCCURS, <br />SEE RCP <br />9" <br />RE <br />F <br />E <br />R <br /> <br />T <br />O <br /> <br />R <br />C <br />P <br />CONT. GYP. BD. <br />CASING EDGE <br />FINISH FLOOR <br />1 <br />1 <br />/ <br />2 <br />" <br />AS <br /> <br />I <br />N <br />D <br />I <br />C <br />A <br />T <br />E <br />D <br /> <br />O <br />N <br /> <br />I <br />N <br />T <br />E <br />R <br />I <br />O <br />R <br /> <br />E <br />L <br />E <br />V <br />A <br />T <br />I <br />O <br />N <br />S <br />HILTI X-ZF .138 DIAMETER X <br />3/4" LONG LOW VELOCITY <br />POWDER ACTUATED DRIVE <br />FASTENERS AT 24" O.C., ICC- <br />ED, ESR 1663. <br />F.R. PLYWOOD <br />SHEET NOTES <br />GENERAL NOTES <br />© Gensler <br />Date Description <br />Project Name <br />Project Number <br />Description <br />Scale <br />Seal / Signature <br />2021 <br />Tel 949.863.9434 <br />Fax 949-553-1676 <br />4675 MacArthur Court <br />Suite 100 <br />Newport Beach, CA <br />92600 <br />USA <br />As indicated <br />9/ <br />2 <br />3 <br />/ <br />2 <br />0 <br />2 <br />4 <br />1 <br />1 <br />: <br />3 <br />9 <br />: <br />2 <br />1 <br /> <br />A <br />M <br />BI <br />M <br /> <br />3 <br />6 <br />0 <br />:/ <br />/ <br />0 <br />0 <br />7 <br />. <br />3 <br />7 <br />5 <br />7 <br />. <br />0 <br />0 <br />0 <br /> <br />- <br /> <br />C <br />ar <br />i <br />b <br />o <br />u <br /> <br />I <br />n <br />d <br />u <br />s <br />t <br />r <br />i <br />e <br />s <br /> - <br /> <br />3 <br />r <br />d <br /> <br />& <br /> <br />B <br />r <br />o <br />a <br />d <br />w <br />a <br />y <br />/3 <br />R <br />D <br />- <br />B <br />_ <br />A <br />R <br />C <br />H <br />_ <br />W <br />ES <br />T <br />_ <br />R <br />2 <br />0 <br />. <br />r <br />v <br />t <br />R1.A6.210 <br />GYP CEILING DETAILS <br />07.3757.400 <br />3rd & Broadway Residential <br />Tower Core & Shell <br />301 N. Broadway, Santa Ana, CA <br />SCALE:3" = 1'-0" <br />TYP GYP BD CLG CONTROL JOINT01 <br />SCALE:3" = 1'-0" <br />GYP BD RETURN AIR SLOT02 <br />SCALE:3" = 1'-0" <br />RETURN AIR SLOT W GYP BD03 <br />SCALE:3" = 1'-0" <br />FLOW BAR DIFFUSER @ Gyp Bd05 <br />SCALE:3" = 1'-0" <br />CEILING SOFFIT / FASCIA 106 <br />SCALE:3" = 1'-0" <br />CEILING TRANSITION 307 <br />03 CERTAINTEED CEILING - 300C - LINEAR PLANK – <br />EXTERIOR <br />SCALE:3" = 1'-0" <br />300C - SYSTEM VERTICAL SUPPORT04 <br />SCALE:1 1/2" = 1'-0" <br />FIRE RATED CEILING DETAIL09 <br />SCALE:3" = 1'-0" <br />TYP. CEILING COVE LIGHT08SCALE:3" = 1'-0" <br />TYP. CEILING COVE LIGHT - ACT11 <br />SCALE:1 1/2" = 1'-0" <br />TYP. WALL W/ ALCOVE ABOVE LOBBY12 09/21/2021 Issue for Plan Check <br />A 12/10/2021 Reissue for Plan Check <br />B 01/18/2022 Reissue for Plan Check <br />H 06/17/2024 Revision to PermitH <br />1/7/25
The URL can be used to link to this page
Your browser does not support the video tag.