My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2007 & 2007 1%2 N Westwood Ave - Plan
PBA
>
Building
>
ProjectDox
>
W
>
Westwood Ave
>
2007 N Westwood Ave
>
2007 & 2007 1%2 N Westwood Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2026 5:00:16 AM
Creation date
3/11/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20187016
20188029
101125203
101126609
Full Address
2007 N Westwood Ave
2007 1/2 N Westwood Ave
Street Number
2007
Partial
1/2
Street Direction
N
Street Name
Westwood
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE <br />REV: C1 2/3/2026 <br />OSCAR GONZALEZ <br />2007 N WESTWOOD AVE, <br />SANTA ANA, CA, 92706 <br />2007 1/2 N WESTWOOD AVE. <br />PROJECT NUMBER: <br /> 109R-007GONZ PR-3004301289 <br />SHEET <br />DESIGNER: <br />HIMANSHU VASHIST <br />CUSTOMER RESIDENCE: <br />ADU ADRESS <br />TEL. (714) 222-8870APN: 399-071-01 <br />(415) 580-6920 ex3 <br />PV-5.0 <br />#ESTAMP#SSTAMP <br />2500 WHITE RD. SUITE A, IRVINE CA 92614 <br />PHONE 805.540.7603 <br />FAX 949.215.7778 <br />CA CL #750184 <br />GILBERT CORREIA, C10, C46 <br />SIGNAGE <br />NOMINAL ESS VOLTAGE VAC <br />LABEL LOCATION: <br />ENERGY STORAGE SYSTEM <br />PER CODE(S): CEC 2022: 706.15(C) <br />120/240 <br />ENERGY STORAGE SYSTEM DISCONNECT <br />ENERGY STORAGE SYSTEM <br />CAUTION! <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 706.15(C) <br />LABEL LOCATION: <br />AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF <br />INTERCONNECTION. <br />PER CODE(S): CEC 2022: 690.54 <br />PV SYSTEM DISCONNECT <br />WARNING! <br />DO NOT RELOCATE THIS <br />OVERCURRENT DEVICE <br />LABEL LOCATION: <br />ADJACENT TO PV BREAKER AND ESS <br />OCPD (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 705.12(B)(3)(2) <br />NOTES AND SPECIFICATIONS: <br />·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE CEC 2022 ARTICLE <br />110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR <br />IF REQUESTED BY THE LOCAL AHJ. <br />·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE <br />WORDS, COLORS AND SYMBOLS. <br />·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING <br />METHOD AND SHALL NOT BE HAND WRITTEN. <br />·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED. <br />·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY <br />SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. <br />·DO NOT COVER EXISTING MANUFACTURER LABELS. <br />SOLAR <br />ELECTRIC PV <br />PANELS <br />LABEL LOCATION: <br />ON OR NO MORE THAT 1 M (3 FT) FROM THE SERVICE <br />DISCONNECTING MEANS TO WHICH THE PV SYSTEMS <br />ARE CONNECTED. <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN PV <br />SYSTEM AND REDUCE SHOCK <br />HAZARD IN THE ARRAY. <br />4" <br />3" <br />PER CODE(S): NEC 2020: 690.56(C), CEC 2022: 690.56(C) <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />LABEL LOCATION: <br />INVERTER(S), AC/DC DISCONNECT(S), <br />AC COMBINER PANEL (IF APPLICABLE). <br />PER CODE(S): CEC 2022: 690.13(B) <br />! <br />INVERTER 1 <br />PHOTOVOLTAIC DC DISCONNECT <br />MAXIMUM SYSTEM VOLTAGE:VDC550 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S). <br />PER CODE(S): CEC 2022: 690.53 <br />LABEL LOCATION: <br />INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, <br />AT EACH TURN, ABOVE AND BELOW PENETRATIONS, <br />ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. <br />PER CODE(S): CEC 2022: 690.31(D)(2) <br />LABEL LOCATION: <br />INSTALLED WITHIN 3' OF RAPID SHUT DOWN <br />SWITCH PER CODE(S): CEC 2022: 690.56(C)(2), IFC <br />2018: 1204.5.3 <br />WARNING! <br />SOURCES: UTILITY GRID, <br />BATTERY AND PV SOLAR <br />ELECTRIC SYSTEM <br />THREE POWER SUPPLY <br />LABEL LOCATION: <br />UTILITY SERVICE METER AND MAIN <br />SERVICE PANEL. <br />PER CODE(S): CEC 2022: 705.12(C) <br />THIS EQUIPMENT FED BY <br />MULTIPLE SOURCES. TOTAL <br />RATING OF ALL OVERCURRENT <br />DEVICES EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE <br />SHALL NOT EXCEED AMPACITY OF <br />BUSBAR <br />WARNING! <br />LABEL LOCATION: <br />PV LOAD CENTER (IF APPLICABLE) AND <br />ANY PANEL THAT UTILIZES "THE SUM <br />OF BREAKERS RULE". <br />PER CODE(S): CEC 2022: 705.12 (B)(3)(3) <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />WARNING: THIS SENSOR IS PART <br />OF A POWER CONTROL SYSTEM. <br />DO NOT REMOVE. REPLACE ONLY <br />WITH THE SAME TYPE AND RATING. <br />REQUIREMENT: UL 1741, SECTION 206.3 <br />LOCATION: AROUND THE CT WIRE BY CLAMP <br />SIZE 4.25" X 0.75" <br />INVERTER 1&2 <br />LABEL LOCATION: <br />REQUIREMENT: UL 1741, SECTION 206.1 AND 206.4 <br />LOCATION: MAIN PANEL <br />SIZE: 4.25" X 1.25" <br />PCS CONTROLLED CURRENT SETTING: 180 A <br />THE MAXIMUM OUTPUT CURRENT FROM THIS <br />SYSTEM IS CONTROLLED ELECTRONICALLY. <br />REFER TO THE MANUFACTURER'S <br />INSTRUCTIONS FOR MORE INFORMATION. <br />LABEL LOCATION: <br />BACKED UP LOADS PANEL <br />C1
The URL can be used to link to this page
Your browser does not support the video tag.