Laserfiche WebLink
Article 220 - Service/Feeder calculation for (address):Job Code <br />2007 N Westwood Ave Santa Ana CA USA 92706 109R-007GONZ <br />Section 220.83 Existing Dwelling Unit <br />Part #1 - Section 220.83(B)(1) General Lighting/Receptacles @ 3 VA per sq ft: <br />Building Square Footage VA (watts)Amps <br />House 2502 7506 31.27 <br />Amps Box A (VA) <br />31.27 7506Total for Part #1: <br />Part #2 - Section 220.83(B)(2),(4) a, b, c, d - Appliances and Dedicated Circuits: <br />Dedicated Circuit Size in VA Dedicated Circuit Size in VA <br />Range 9600 N/A <br />Water Heater 3840 N/A <br />Cooktop 3840 N/A <br />Disposal 600 N/A <br />Refrigerator 1000 N/A <br />Laundry 1500 N/A <br />Appliance Circuit(s)3000 N/A <br />N/A N/A <br />N/A N/A <br />N/A Amps Box B (VA) <br />N/A 23380 97.42Total for Part #2: <br />Total VA from Parts #1 and #2 combined:Box A + Box B = 7603.42 <br />Total VA 30886 <br />First 8000 VA @ 100% 8000 Remaining VA @ 40% <br />Remaining VA = 22886 22886 x 40% = 9154.4 VA <br />Adding First 8,000 VA 8000 VA <br />17154.4 VA <br />71.48 Amps <br />Total VA for Gen. Lights/Recep, Appliances & Dedicated circuits: <br />Total AMP for Gen. Lights/Recep, Appliances & Dedicated circuits: <br />Part #3 - Section 220.83(B) Heating and A/C loads: <br />100% of all the Heating or A/C loads in VA: 10512 VA <br />100% of all the Heating or A/C loads in Amps: 43.8 A <br />*Combine the larger loads of either the Heating or the A/C loads togther <br />Totals from all Parts#EStamp <br />VA Volts Amps <br />Parts #1 & #2 17154.4 240 71.48 <br />Part #3 10512 240 43.8 <br />Total VA for all Parts: 27666.4 <br />Totals Service/Feeder Load 115.28