Laserfiche WebLink
Monika Stamp <br />EVERGREEN SOLAR <br />AND HOME BATTERY INC <br />Address:11278 LOS ALAMITOS BLVD, <br />SUITE 707,LOS ALAMITOS, CA 90720 <br />Phone: (562) 666-7174 <br />State License number: 1102899 <br />Expire Date: 03/31/25 <br />License Class: C-46 <br />Email: bryan@evergreen-solar.net <br />Workers Comp: ACCREDITED SURETY <br />AND CASUALTY COMPANY INC <br />Policy Number:1AUICA160143417700 <br />Expire Date: 03/20/2024 <br />License holder-Bryan Amburgey <br />1009 W River Ln Unit #2 <br />Santa Ana, CA 92706 <br />Date: JANUARY 15, 2026 <br />Project Information <br />PV-1 <br />SHEET INDEX <br />PV-2.1 <br />PV-2.2 <br />PV-3 <br />PV-4 <br />From <br />Page 6 <br />Plot Plan <br />Stringing <br />Single line diagram <br />Array Layout <br />Signage <br />Additional Information <br />Data sheets, <br />Certifications... <br />DC SIZE <br />AC SIZE <br />3.22KW <br />2.68KW <br />SYSTEM SIZE <br />EXISTING <br />100A <br />100A <br />7 <br />7 <br />REC460AA PURE-RX <br />IQ8X-80-M-US <br />COVER <br />PROJECT NOTES <br />PROJECT MAP (N.T.S.) <br />1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED <br />AND IDENTIFIED UL 1703. <br />2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS <br />3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. <br />4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT <br />PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. <br />5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT <br />THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE <br />PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. <br />6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM <br />ANY PHYSICAL DAMAGE. <br />7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND <br />SHALL NOT BE <br />ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. <br />8 .INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT <br />PROTECTION <br />9. ALL CONDUCTORS SHALL BE COPPER AND 75 DEG RATED <br />10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING <br />LABORATORY OR APPROVED BY THE DEPARTMENT. <br />11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS <br />12.ALL WORK SHALL BE IN ACCORD WITH THE 2022 CBC, 2022 CEC <br />13. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE <br />CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING <br />MEANS AS PER 230.82(6) <br />14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE <br />FUNCTIONS OF DC GROUNDING, AC GROUNDING <br />AND BONDING BETWEEN AC AND DC SYSTEMS AS PER CEC 250.122 <br />15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. <br />16. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE <br />EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS <br />GENERAL NOTES: <br />THIS INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: <br />2025 California Administrative Code (CAC) <br />2025 California Building Code (CBC) <br />2025 California Residential Code (CRC) <br />2025 California Electrical Code (CEC) <br />2025 California Mechanical Code (CMC) <br />2025 California Plumbing Code (CPC) <br />2025 California Energy Code (CEnC) <br />2025 California Wildland-Urban Interface Code (CWUI) <br />2025 California Historical Building Code (CHBC) <br />2025 California Fire Code (CFC) <br />2025 California Existing Building Code (CEBC) <br />2025 California Green Building Standards Code (CALGreen) <br />2025 California Reference Standards Code <br />code summary <br />additional notes space (if needed) <br />N <br />FROM JUNCTION BOX TO ROOF EAVE <br />EMT TYPE CONDUIT WILL RUN OVER <br />THE ROOF AT 3 1/2" HEIGHT, THEN <br />UNDER THE EAVE TO PV EQUIPMENT <br />project description <br />DC SOLAR PHOTOVOLTAIC SYSTEM <br />MAIN SERVICE PANEL <br />CONDUCTORS TYPE <br />CONDUITS TYPE ON ROOF <br />CONDUITS TYPE FROM EQUIPMENT <br />ROOF TYPE <br />ROOF RAFTERS <br />additional system info <br />AC SOLAR SYSTEM SIZE <br />NUMBER OF SOLAR MODULES <br />NUMBER OF INVERTERS <br />SOLAR PANEL MODEL NUMBER <br />INVERTERS MODEL NUMBER <br />ADDITIONAL DC OPTIMIZER <br />MAIN SERVICE PANEL BUS <br />MAIN SERVICE PANEL MAIN C/B <br />NUMBER OF ROOF STORY <br />PROPERTY DETAILS <br />APN <br />LIVING AREA <br />PROPERTY TYPE <br />OCCUPANCY GROUP <br />1 <br />THWN-2 <br />EMT <br />EMT <br />00123105 <br />976 sqft <br />RESIDENTIAL <br />R-3 <br />20ATOTAL PV SIZE <br />2x10" 12" O/C <br />SHINGLE <br />IRONRIDGEMOUNTING SYSTEM <br />N/A <br />3.22KW 2.68KW <br />AHJ City of Santa Ana <br />CONSTRUCTION TYPE V-B <br />SIGNED ON: <br />Structural Only <br />02/14/2026