My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1411 N Durant St - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Durant St
>
1411 N Durant St
>
1411 N Durant St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2026 5:00:12 AM
Creation date
3/17/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
20186767
20188156
101124832
Full Address
1411 N Durant St
1411 N Durant St Unit# MET01
Street Number
1411
Street Direction
N
Street Name
Durant
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Project: Ross Durant I -- Job #: 2025-04579 <br />Date: 7/29/2025 Engineer: DF <br />Number of PV Modules: 100 Modules <br />Number of Bays: 148 Bays <br />Number of Positive Attachments: 18 attachments <br />Number of ballast blocks: 112 blocks <br />Block type: 4x8x16 (Nominal) CMU Cap Block <br />Block weight, W =32.5 lb <br />Weight of PV Modules & racking: 6,003 lb Area covered by PV system: 2,762 Sq. ft <br />Weight of Ballast: 3,640 lb Average PV system dead load: 3.5 psf <br />Total weight of PV system: 9,643 lb <br />Summary by Roof: <br />Roof Name # of <br />Modules <br /># of <br />Bays <br /># of <br />Blocks N/A # of <br />Attachments <br />PV Area <br />(Sq. ft) <br />Average <br />Weight (psf) <br />Max Bay <br />Weight (lb) <br />Roof 1 52 76 58 0 9 1,436.2 3.5 85.8 <br />Roof 2 48 72 54 0 9 1,325.7 3.5 85.8 <br />Summary by Section: <br />Section Name # of <br />Modules <br /># of <br />Bays <br /># of <br />Blocks N/A # of <br />Attachments <br />Array Area <br />(Sq. ft) <br />Average <br />Weight (psf) <br />Max Bay <br />Weight (lb) <br />Roof 1 Arr 1 52 76 58 0 9 1,436.2 3.5 85.8 <br />Roof 2 Arr 1 48 72 54 0 9 1,325.7 3.5 85.8 <br />Totals: 100 148 112 0 18 2,762 <br />1 2 3 <br />Summary of Ballast Calculations: <br />The block weight is a critical component of these calculations. If the actual block weight(s) differ from that shown here, these <br />calculations shall be considered invalid. Please contact PZSE so that accurate ballast counts may be provided. <br />Note: Print order for large array calculations is "RIGHT THEN DOWN" <br />4 5 6 <br />7 8 9 <br />Page 8 of 29
The URL can be used to link to this page
Your browser does not support the video tag.