My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SD40 - 730 S Van Ness Ave - Plan
PBA
>
Building
>
ProjectDox
>
V
>
Van Ness Ave
>
730 S Van Ness Ave
>
SD40 - 730 S Van Ness Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/19/2026 5:00:12 AM
Creation date
3/19/2026 5:00:06 AM
Metadata
Fields
Template:
Plan
Permit Number
101124976
Full Address
730 S Van Ness Ave
Street Number
730
Street Direction
S
Street Name
Van Ness
Street Suffix
Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
125
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CITY OF SANTA ANA <br />Planning and Building Agency <br />2022 Single -Family Residential Mandatory Requirements S <br />NOTE: Single-family residential buildings subject to the Energy Codes must comply with all applicable mandatory measures, rE <br />used. Review the respective section for more information. <br />(04/2022) <br />Building Envelope: <br />mmaryApproved <br />rrdli TLPMM�W, ANCE <br />Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage t <br />3 M per square foot or <br />Na- <br />§ 110.6(a)1: <br />less when tested per NFRC-400, ASTM E283, or AAMA/WDMA/CSA 101/I.S.2/A440-2011. ' <br />e: <br />§ 110.6(a)5: <br />Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 1 <br />Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from <br />§ 110.6(b): <br />Tables 110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped. <br />Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be <br />§ 110.7: <br />caulked, gasketed, or weather stripped. <br />§ 110.8(a): <br />Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs. Bureau of Household <br />Goods and Services BHGS . <br />§ 110.8(g): <br />Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g). <br />Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the <br />§ 110.8(i): <br />roofing material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified <br />on the CF1 R. <br />§ 110.80): <br />Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer <br />Affairs. <br />Roof Deck, Ceiling and Rafter Roof Insulation. Roof decks in newly constructed attics in climate zones 4 and 8-16 area -weighted <br />average U-factor not exceeding U-0.184. Ceiling and rafter roofs minimum R-22 insulation in wood -frame ceiling; or area -weighted average <br />§ 150.0(a): <br />U-factor must not exceed 0.043. Rafter roof alterations minimum R-19 or area -weighted average U-factor of 0.054 or less. Attic access <br />doors must have permanently attached insulation using adhesive or mechanical fasteners. The attic access must be gasketed to <br />prevent air leakage. Insulation must be installed in direct contact with a roof or ceiling which is sealed to limit infiltration and exfiltration <br />asspecified in § 110.7, including but not limited to placing insulation either above or below the roof deck or on top of a drywall ceiling. r <br />§ 150.0(b): <br />Loose -fill Insulation. Loose fill insulation must meet the manufacturer's required density for the labeled R-value. <br />Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood <br />§ 150.0(c): <br />framing or have a U-factor of 0.071 or less. Opaque non -framed assemblies must have an overall assembly U-factor not exceeding 0.102. <br />Masonry walls must meet Tables 150.1-A or B. <br />§ 150.0(d): <br />Raised -floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor. ; <br />Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone <br />§ 150.0(f): <br />without facings, no greater than 0.3 percent: have a water vapor permeance no greater than 2.0 perm per inch; be protected from <br />physical damage and UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g), <br />Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II <br />§ 150.0(g)l: <br />vapor retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to <br />150.0 d . <br />Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of <br />§ 150.0(g)2: <br />all insulation in all exterior walls, vented attics, and unvented attics with air -permeable insulation. <br />Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have <br />§ 150.0(q): <br />a maximum U-factor of 0.45; or area -weighted average U-factor of all fenestration must not exceed 0.45. <br />Fireplaces, Decorative Gas Appliances, and Gas Log: <br />§ 110.5(e) <br />Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces. <br />§ 150.0(e)l: <br />Closable Doors. Masonry or factory -built fireplaces must have a closable metal or glass door covering the entire opening of the firebox. <br />§ 150.0(e)2: <br />Combustion Intake. Masonry or factory -built fireplaces must have a combustion outside air intake, which is at least six square inches in <br />area and is equipped with a readily accessible, operable, and fight -fitting damper or combustion -air control device. <br />§ 150.0(e)3: <br />Flue Damper. Masonry or factory -built fireplaces must have a flue damper with a readily accessible control. <br />Space Conditioning, Water Heating, and Plumbing System: <br />Certification. Heating, ventilation, and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other <br />§ 110.0-§ 110.3: <br />regulated appliances must be certified by the manufacturer to the California Energy Commission. <br />§ 110.2(a): <br />HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-N. <br />Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance <br />§ 110.2(b): <br />heaters must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; <br />and in which the cut -on temperature for compression heating is higher than the cut -on temperature for supplementary heating, and <br />the cut-off temperature for compression heating is higher than the cut-off temperature for supplementary heating. <br />Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a <br />§ 110.2(c): <br />setback thermostat. <br />Insulation. Unfired service water heater storage tanks and solar water -heating backup tanks must have adequate insulation, or tank <br />110.3 c 3: <br />surface heat loss rating. <br />Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with <br />§ 110.3(c)6: <br />hose bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed. <br />5/6/22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.