Laserfiche WebLink
3'-0" x 7'-0"1 3/4"EXISTING <br />ACCESSIBLE SIGNAGE KEY NOTES <br />MAIN EXIT DOOR SHALL PROVIDED WITH A DURABLE SIGN OF ONE (1") LETTERS <br />ON CONTRASTING BACKGROUND INDICATING ( THESE DOORS SHALL REMAIN <br />UNLOCKED WHEN THIS SPACE IS OCCUPIED) PER SEC. 1008.1.9.3 <br />1 <br />TACTILE EXIT SIGN W./ WORDS "EXIT" (1011.1, 1011.4.9(4))2 <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGNAGE.3 <br />THIS TABLE TO BE OPEN AT ALL TIMES FOR CUSTOMER WITH DISABILITIES <br />CLEAR FOR ACCESSIBLE AT COUNTER MAX. 34" HIGH AND 36" WIDE4 <br />INDICATES TOTAL CAPACITY POSTED "MAXIMUM <br />OCCUPANT LOAD 13 PERSON"5 <br />6 <br />ALL EXTERIORS ARE SELF-CLOSING, <br />TIGHT-FITTING RODENT-PROOF7 <br />RESTROOM VENTILATION IS LIGHT SWITCH <br />ACTIVATED MECHANICAL EX. FAN8 <br />EXIT SIGNAGE TO COMPLY PER CBC SECTION 1013 <br />9 <br />(E.) FIXED EXTERIOR GLAZING BEHIND <br />(E.) EXTERIOR NON-BEARING WALLS NO CHANGE <br />(E) INTERIOR NON-BEARING PARTITION TO BE REMAIN <br />(E.) & (N.) FLOOR PLAN WALL LEGEND: <br />FLOOR PLAN NOTES: <br />1.WALL AND CEILING MATERIALS SHALL NOT EXCEED THE FLAME SPREAD CLASSIFICATIONS IN CBC TABLE 803.9 <br />2.DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR <br />EFFORT IN CBC TABLE 1008.1.9) <br />3.ALL CABINETS MILLWORKS DRAWING AND INSTALLATION BY OTHER <br />4.ALL BASE CABINETS SHALL BE @ 34" MAX. HEIGHT <br />5.NO HAZARDOUS MATERIALS WILL BE STORED AND/ OR USED WITHIN THE BUILDING,WHICH WILL EXCEED THE QUANTITIES LISTED <br />IN CBC 414.2.5(1) <br />6.THERE WILL NOT BE ANY DIAMOND PLATE ON THE WALK IN UNIT DOORS OR WALLS. <br />EXISTING FLOOR PLAN <br />SCALE: 1/4" = 1' 0" <br />2 <br />(E) ENTRY <br />(E <br />) <br />FI <br />X <br />E <br />D <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />60 <br />x <br />7 <br />2 <br /> <br />C <br />L <br />R <br />. <br />(E)FIXED WINDOW <br />(E) <br />(N) <br />ALL GENDER <br />RESTROOM <br />(E) <br />(E) <br />(E) SUB-PANEL <br />(E) SUB-PANEL <br />(E <br />) <br />FI <br />X <br />E <br />D <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E)FIXED WINDOW(E)FIXED WINDOW(E)FIXED WINDOW(E)FIXED WINDOW <br />16 <br />4 <br />1 <br /> <br />E <br />, <br /> <br />1 <br />7 <br />t <br />h <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br /> <br /># <br />A <br />, <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />De <br />s <br />i <br />g <br />n <br />10 <br />4 <br />9 <br />2 <br /> <br />T <br />R <br />A <br />S <br />K <br /> <br />A <br />V <br />E <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />B <br />Ga <br />r <br />d <br />e <br />n <br /> <br />G <br />r <br />o <br />v <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />8 <br />4 <br />3 <br />Ph <br />o <br />n <br />e <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br />4 <br />1 <br />7 <br />- <br />1 <br />8 <br />3 <br />9 <br /> <br />- <br /> <br />( <br />6 <br />5 <br />7 <br />) <br />7 <br />2 <br />0 <br />- <br />8 <br />5 <br />5 <br />5 <br />ki <br />m <br />k <br />h <br />u <br />e <br />. <br />n <br />g <br />u <br />y <br />e <br />n <br />2 <br />0 <br />1 <br />8 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />ar <br />t <br />. <br />d <br />e <br />s <br />i <br />g <br />n <br />. <br />g <br />r <br />o <br />u <br />p <br />2 <br />0 <br />2 <br />2 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />. <br />A <br />P <br />R <br />O <br />J <br />E <br />C <br />T <br /> <br />F <br />O <br />R <br />TE <br />N <br />A <br />N <br />T <br /> <br />I <br />M <br />P <br />R <br />O <br />V <br />E <br />M <br />E <br />N <br />T <br />DATE: <br />09.08.25 <br />EXISTING FLOOR PLAN <br />PROPOSED FLOOR PLAN <br />A1 <br />REVISION <br />DA <br />T <br />E <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />WA <br />T <br />E <br />R <br /> <br />S <br />T <br />O <br />R <br />E <br />PROPOSED FLOOR PLAN <br />SCALE: 1/4" = 1' 0" <br />1 <br />(E) ENTRY <br />(E <br />) <br />FI <br />X <br />E <br />D <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E)FIXED WINDOW <br />(E) <br />ALL GENDER <br />RESTROOM <br />(E <br />) <br />(E <br />) <br />FI <br />X <br />E <br />D <br /> <br />W <br />I <br />N <br />D <br />O <br />W <br />(E)FIXED WINDOW(E)FIXED WINDOW <br />WATER TANK <br />550 GAL <br />RECEPTION <br />8 <br />F <br />A <br />U <br />C <br />E <br />T <br />S <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />8 <br />F <br />A <br />U <br />C <br />E <br />T <br />S <br /> <br />D <br />I <br />S <br />P <br />E <br />N <br />S <br />E <br />R <br />FILTER SYSTEM <br />WITH 3 MOTORS <br />FILTER ROOM <br />STORE <br />ROOM <br />ICE MERCHANDISER <br />ICE MACHINE <br />24 HRS <br />DISPENSER <br />24 HRS <br />DISPENSER <br />24 HRS <br />DISPENSER <br />8 FAUCETS DISPENSER <br />(E) EXIT <br />(E) ENTRY <br />1 <br />2 2 <br />333 <br />4 <br />5 67 <br />77 <br />9 <br />10 <br />EXISTING NON-BEARING WALL TO BE REMOVED <br />EXISTING NON-BEARING WALL TO BE REMOVED <br />EXISTING NON-BEARING WALL TO BE REMOVED <br />EXISTING NON-BEARING WALL TO BE REMOVED <br />OBSTRUCTION <br />10" MAX <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br />MI <br />N <br />. <br />OBSTRUCTED SIDE REACH <br />OBSTRUCTION <br />10" MAX30" <br />34 <br />" <br /> <br />M <br />A <br />X <br />ACCESSIBLE @ COUNTER SIDE REACH <br />ACCESSIBLE REACH RANGES <br />1/4" max. <br />1/ <br />2 <br />" <br /> <br />m <br />a <br />x <br />. <br />THRESHOLDTRANSITION BETWEEN FLOOR FINISHES <br />COMPRESSED CARPET 1/4" MAX. BELOW <br />THRESHOLD <br />FINISH FLOOR EVEN <br />THRESHOLD <br />THESE DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS OF <br />THESE REGULATIONS AND ARE INTENDED ONLY AS AN AID FOR <br />BUILDING DESIGN AND CONSTRUCTION. <br />TYP. THRESHOLD DETAIL <br />ACCESSIBLE SINK 5 <br />7 <br />EXIT <br />ACCESSIBLE <br />RESTROOM <br />60" MAX. A.F.F <br />48" MIN. A.F.F 18" MIN. <br />18 <br />" <br /> <br />M <br />I <br />N <br />. <br />LETTERS AND NUMBERS: <br />1.WIDTH TO HEIGHT RATIO BETWEEN 3 : 5 AND 1 : 1. <br />2.STROKE WIDTH TO HEIGHT BETWEEN 1 : 5 AND 1 : 10. <br />3.CONTRAST CHARACTERS AND SYMBOLS WITH <br />BACKGROUND (70% CONTRAST). <br />4.SANS SERIF CHARACTERS. <br />REQUIREMENTS. <br />ALL SIGNAGE SHALL CONFORM THE STATE <br />BUT NOT LIMITED TO PROPORTION, COLOR <br />OF CALIFORNIA TITLE 24 GUIDELINES, INCLUDING <br />CONTRAST AND RELIEF AND GRADE 2 BRAILLE <br />NOTE: <br />ADHESIVE MOUNTED <br />PLASTIC NAME RATED <br />ANSI APPROVED E.S. <br />WALL SIGN <br />SELF EXTINGUISHING <br />BACKGROUND <br />BLUE <br />SYMBOL <br />WHITE <br />58 <br />" <br /> <br />M <br />I <br />N <br />. <br />TO <br /> <br />6 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />LETTERING RAISED <br />1/32" <br />UPPERCASE <br />CHARACTERS CORRESPONDING <br />GRADE II BRAILLE <br />BRAILLE TO BE <br />LOCATED DIRECTLY <br />BELOW & FLUSH LEFT <br />OR CENTERED ON <br />RAISED CHARACTERS <br />Door mounted signage <br />per (CBC 11B-703) <br />WALL MOUNTED SIGNAGE TO BE <br />LOCATED ON LATCH SIDE OF <br />DOOR CLEAR OF DOOR-SWING. <br />MOUNT AT 60" TO CENTERLINE OF <br />SIGN FROM FLOOR. <br />48 <br />" <br /> <br />M <br />I <br />N <br />. <br />A. <br />F <br />. <br />F <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />58 <br />" <br /> <br />M <br />I <br />N <br />. <br /> <br />T <br />O <br /> <br />6 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />ALL GENDER <br />PLASTIC LAMINATE SECURED TO <br />CENTER OF DOOR FACE +60" A.F.F. <br />DOOR SIGN <br />CONTRAST OF THE DOOR. <br />ADHESIVE TO MOUNT. <br />USE NAME RATED SELF-EXTINGUISHING <br />70% CONTRAST FROM COLOR AND <br />COLOR AND CONTRAST SHALL BE <br />A. <br />F <br />. <br />F <br />. <br />44 <br />" <br /> <br />M <br />A <br />X <br />. <br />10" MIN. <br />KICK PLATE <br />AFF. <br /> ACCESSIBLE SIGNAGE 3 <br />ITEM QTY.DESCRIPTION MANUF.MODEL#REMARKS <br />1 <br />2 <br />3 <br />1 <br />1 <br />1 <br />1 <br />EQUIPMENT SCHEDULE <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />8 <br />9 <br />10 <br />7 <br />ICE BIN. Manitowoc D970 <br />FILTER SYSTEM WITH 3 MOTORS EU1502US MOTORS <br />WATER TANK 550 GAL <br />24 HRS DISPENSER <br />ICE MERCHANDISER.750CWGPP0LAR TEMP <br />ICE MAKER.Manitowoc ID1492N-261 <br />CUSTOM MADEALLSTRONG8 FAUCETS DISPENSER <br />CUSTOM MADERECEPTION <br />3 <br />1 <br />1 <br />EXISTING ELECTRICAL PANEL <br />ALL EQUIPMENT SHALL BE ANSI/NSF CERTIFIED <br />208V <br />COSTER <br />4 <br />6 <br />CTV 200 SINGLE WINDOW VENDING MACHINE <br />8 <br />CUSTOM MADE <br />EXISTING ELECTRICAL PANEL <br />#Q.SIZE DESCRIPTION DOOR FINISH FRAME M.F.LOCATION REMARKSTHICK <br />1 3/4"ALUM. <br />DOOR HARDWARE/ HINGERS <br />LOCK, SEALS, DOOR BOTTOM& THRESHOLD <br />1 <br />EXISTING AND NEW DOOR SCHEDULE <br />TEMP. GLASS <br />MAIN EXIT DOOR SHALL PROVIDED WITH A DURABLE SIGN OF ONE (1") <br />LETTERS ON CONTRASTING BACKGROUND INDICATING (THERE DOOR TO <br />REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED) <br />PUSH - PULL <br />FRONT <br />EXTERIOR DOOR <br />FRONT ENTRANCE <br />DOOREXISTING <br />1 <br />101A <br />SURFACE CLOSER-P404 1 EDA-695-LCN. <br />KICK PLATE-8400 10"x2" LDW-613-IVES <br />LOCK GUARD-LG1-600 <br />101B <br />3'-0" x 7'-0"1 3/4" <br />INTERIOR WD. SOLID <br />CORE <br />SELF-CLOSING <br />LEVER TYPE <br />PAINT SEMI <br />GLOSS <br />WD. <br />6'-0" x 7'-0" <br />101C <br />EXISTING <br />1 <br />All means of egress doors shall comply with the requirements of Section 1010.1. <br />a. Means of egress doors shall be readily distinguishable from the adjacent construction and finishes <br />with no mirrors, curtains, drapes, decorations, or similar materials. <br />b. Required exit doors shall have not less than 32-in. clear width, 80-in. clear height, and shall be <br />capable of opening 90 degrees. The maximum swinging door leaf width is 48-in. nominal. <br />c. Egress doors shall be of the pivoted or side-hinged swinging type. <br />d. The force for pushing or pulling open interior swinging egress doors, other than fire doors, shall not <br />exceed 5 pounds. For other swinging doors, as well as sliding and folding doors, the door latch shall <br />release when subjected to a 15-pound force. The door shall be set in motion when subjected to <br />a 30-pound force. The door shall swing to a fullopen position when subjected to a 15-pound <br />force. Revolving and sliding doors maybe used in other than Group H occupancies as egress doors <br />only if all of the requirements of Section 1010.1.4.1 and Section 1010.1.4.3, respectively, are met. <br />DOORS WITH CLOSER TO BE ADJUSTED TO HAVE A MAXIMUM OPENING FORCE OF 5 LBS AT <br />INTERIOR AND 5 LBS AT EXTERIOR DOORS <br />18" HIGH STAINLESS KICKPLATES ON BOTH SIDES <br />a/ ALL DOOR HARDWARE TO MEET ADA CODE, b/ VERIFY EXISTING DOORS TO MEET CODE <br />1.ALL EXIT DOORS SHALL PROVIDE FOR DISABLED ACCESS PER CBC <br />11B-404.2.7. <br />2.HAND-ACTIVATED DOOR OPENING HARDWARE MUST BE CENTERED <br />BETWEEN 34 AND 44 INCHES ABOVE FINISH FLOOR.(2022 CBC 11B-404.2.7) <br />3.ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE <br />USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT IN <br />ACCORDANCE WITH THE CBC. DOOR HARDWARE SHALL BE OPERABLE <br />WITH A SINGLE EFFORT WITHOUT REQUIRING THE ABILITY TO GRASP <br />THE HARDWARE (LEVER OR PUSH TYPE IS ACCEPTABLE) PER CBC <br />11B-404.2.7. <br />4.PER CBC 11B-4-4.2.9, THE MAXIMUM EFFORT TO OPERATE DOORS SHALL <br />NOT EXCEED 5 FOR EXTERIOR AND INTERIOR DOORS, SUCH PULL OR <br />PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO HINGED DOORS AND <br />AT THE CENTER PLACE OF SLIDING OR FOLDING DOORS. COMPENSATING <br />DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED TO MEET <br />THE ABOVE STANDARDS. <br />5.PANIC HARDWARE SHALL COMPLY WITH CBC 1010.1.10 <br />6.THE LOWER 10" OF THE DOOR SHALL BE A SMOOTH AND PLANE <br />SURFACE. (NO RECESS OR TRAP). <br />7.MODIFY WIDTH OF DOOR STOP TO ACCOMMODATE TOTAL DOOR <br />THICKNESS, INCLUDING VENEER. <br />8.2022 CBC 11B-404.2.8.1: DOOR CLOSER SHALL BE ADJUSTED SO THAT <br />FROM AN OPEN POSITION OF 90 DEGREES, THE TIME REQUIRED TO <br />MOVE THE DOOR TO A POSITION OF 12 DEGREES FROM THE LATCH IS 5 <br />SECONDS MINIMUM . <br />9.LEVEL LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS. <br />LANDINGS SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE <br />DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF <br />THE DOOR AND A LENGTH MEASURED IN THE DIRECTION OF TRAVEL OF <br />NOT LESS THAN 44 INCHES PER CBC 1010.1.5, 1010.1.6. THE WIDTH OF <br />THE LEVEL AREA ON THE SIDE TO WHICH THE DOOR SWINGS SHALL <br />EXTEND 24" PAST THE STRIKE EDGE OF THE EXTERIOR DOORS AND 18" <br />FOR INTERIOR DOORS. <br />10.THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2" LOWER THAN <br />THE THRESHOLD OF THE DOORWAY. BEVEL 1:2 MAX. SLOPE, WHERE <br />THRESHOLD EXCEEDS 1/4" IN HEIGHT. <br />11.EXTERIOR LEVEL LANDING MAY SLOPE UP TO 1/4" PER FOOT IN ANY <br />DIRECTION FOR SURFACE DRAINAGE. SEE CIVIL DRAWINGS FOR GRADE <br />ELEVATIONS. <br />12.WHERE NOTED AND/OR REQUIRED, A DURABLE SIGN WITH LETTERING <br />ON A CONTRASTING BACKGROUND WILL BE PLACED OVER EXIT DOORS <br />STATING "THIS DOOR TO REMAIN UNLOCKED WHEN THE BUILDING IS <br />OCCUPIED" PER CBC 1010.1.9.3. PROVIDE INTERNATIONAL SYMBOL OF <br />ACCESSIBILITY AT ALL ACCESSIBLE ENTRANCES PER CBC 11B-216.1 & <br />11B-703.1 <br />13.PROVIDE CBC COMPLIANT WALL AND DOOR SIGNAGE AT ALL <br />ACCESSIBLE RESTROOMS. <br />11B-305.3 Size: The clear floor or ground space shall be 30 inches minimum by 48 <br />inches minimum. <br />11B-305.6 Approach <br />One full unobstructed side of the clear floor or ground space shall adjoin an <br />accessible route or adjoin another clear floor or ground space. Clear floor or ground <br />space may overlap an accessible route, unless specifically prohibited elsewhere in <br />this chapter. <br />11B-305.7 Maneuvering clearance <br />Where a clear floor or ground space is located in an alcove or otherwise confined on <br />all or part of three sides, additional maneuvering clearance shall be provided in <br />accordance with Sections 11B-305.7.1 and 11B-305.7.2. <br />11B-305.7.1 Forward approach Alcoves shall be 36 inches wide minimum where the <br />depth exceeds 24" <br />(11B-305.7.2 Parallel approach <br />Alcoves shall be 60 inches wide minimum where the depth exceeds 15 inches) <br />11B-611.2 Clear floor space <br />A clear floor or ground space complying with Section 11B-305 positioned for parallel <br />approach shall be provided. The clear floor or ground space shall be centered on the <br />appliance. <br />11B-611.3 Operable parts <br />Operable parts, including doors, lint screens, and detergent and bleach <br />compartments shall comply with Section 11B-309. <br />11B-611.4 Height <br />Top loading machines shall have the door to the laundry compartment located 36 <br />inches (914 mm) maximum above the finish floor. Front loading machines shall have <br />the bottom of the opening to the laundry compartment located 15 inches minimum <br />and 36 inches maximum above the finish floor. <br />11B-504.2 Treads and risers <br />All steps on a flight of stairs shall have uniform riser heights and uniform tread <br />depths. Risers shall be 4 inches (102 mm) high minimum and 7 inches (178 mm) <br />high maximum. Treads shall be 11 inches (279 mm) deep minimum. <br />DOOR NOTES <br />ACCESSIBILITY NOTES <br />101A <br />(N) INTERIOR NON-BEARING PARTITION <br />(E) INTERIOR NON-BEARING PARTITION TO BE REMOVED <br />PUSH - PULL <br />PANIC EXIT DEVICE <br />BACK <br />EXTERIOR DOOR <br />MTL. PAINT <br />SEMI GLOSS MTL.EXIT DOOR <br />SELF-CLOSING <br />LEVER TYPE <br />101D <br />1 7 <br />23 <br />4 <br />7 <br />A-1 <br />5 <br />6 <br />6 <br />PANIC HARDWARE <br />7 9 <br />101C <br />8 <br />1 7 <br />1 3'-0" x 7'-0" <br />10 <br />1 <br />B <br />101D <br />10 <br />1 <br />D <br />NEW <br />10 <br />1 <br />E <br />ALUM.TEMP. GLASS NEW FILTER ROOM SLIDING DOOR <br />RESTROOM ROOM <br />STORE ROOM <br />SIDE DOOR <br />SLIDING DOOR16'-0" x 7'-0"1 3/4"101E <br />(E) EXIT <br />111 <br />12 <br />THREE COMP. SINK <br />W/2 DRAIN BOARDS. W/PRE-RISER <br />2 SPOUT FAUCETS <br />HAND SINK WITH SIDE SPLASH GUARD 600SH-12SPREGENCY112 <br />13 1 ELECTRIC TANK TYPE WATER HEATER RHEEM <br />A <br />1s <br />t <br /> <br />H <br />E <br />A <br />L <br />T <br />H <br /> <br />C <br />O <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />1 <br />1s <br />t <br /> <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />C <br />O <br />R <br />R <br />E <br />C <br />T <br />I <br />O <br />N <br />A <br />114 <br />14 <br />JANITORIAL SINK <br />1.The janitorial sink must be securely attached to the wall. Support legs must be of smooth, easily cleanable construction. L angle type legs are not acceptable. <br />2.The rim of the sink must be no more than 30 inches above the floor. <br />3.The flooring in the janitorial sink area must be continuous in design extending up walls/toe kicks at least four (4) inches, forming a minimum 3/8" radius coved base as an integral unit. <br />4.The mixing valve faucet at the janitorial sink shall be equipped with a backflow prevention device. <br />A <br />6" LEGS <br />USE THE THE FILTERED WATER FROM <br />THE FILTER SYSTEM IN FILTER ROOM. <br />1 WORKING TABLE15 REGENCY <br />15 <br />DRY SHELVES STORAGE REGENCY 460EC1848K75 6" LEGS48 ln16 <br />6" LEGS <br />A <br />16 <br />16 <br />16 <br />600TB2448G <br />A <br />13 <br />REGENCY <br />11 <br />522S31818LRC <br />ELDS52-(F)TB 81 GPH @ 60°F RISE, 12KW. ABOVE MOP SINK <br />B-B <br />A-2 <br />A-A <br />A-2 <br />ON 4 INCH <br />CONCRETE CURB <br />ON 4 INCH CONCRETE CURB <br />SELF-CLOSING <br />LEVER TYPE <br />A <br />117 EMPLOYEE LOCKER, 6 BOX LOCKERS GSW EL-5DR W/6" LEGS <br />MOP SINK, WALL FAUCET & MOP RACK MUSTEE <br />w/1 drain boards. <br />Indirect to floor sink <br />63M, <br />#63.600A & #65.600 <br />C-C <br />A-2 <br />17 <br />AIR CURTAIN WITH 2389 FPM MARS NH236-1U WITH MICRO SWITCH & <br />HARD WIRE <br />18 <br />118