Laserfiche WebLink
FOUNDATION TRACK <br />3. <br />4. <br />5. <br />14. <br />13. <br />6. <br />7. <br />8. <br />9. <br />10. <br />FLOOR SLAB SHALL BE POURED LEVEL TO 1/8" IN 10'. <br />12. <br />15. <br />11. <br />ADMIXTURES IN CONCRETE MIX. CONTAINING CALCIUM CHLORIDES SHALL NOT BE USED. <br />16. <br />18. <br />17. <br />19. <br />a. DO NOT WALK ON SLAB UNTIL 24 HOURS AFTER CONCRETE HAS BEEN POURED. <br />b. BEGIN WALL FRAMING 4-5 DAYS AFTER CONCRETE POURED. <br />c. BEGIN ROOF/FLOOR FRAMING 7-10 DAYS AFTER CONCRETE POURED. <br />d. DO NOT LOAD ROOF PRIOR TO 14 DAYS AFTER CONCRETE POURED. <br />FOR INTERIOR NON-SHEAR WALLS USE SIMPSON PDPA SERIES 0.157"Ø PINS WITH A <br />PENETRATION OF 1 1/4" INTO SLAB AT 24" O.C. TO BE INSTALLED IN ACCORDANCE WITH <br />ICC ESR-2138. ACTUAL SLAB THICKNESS TO BE MINIMUM 4". ALL INTERIOR SHEAR WALLS <br />TO HAVE A.BS. PER FOUNDATION PLAN. <br />ALL HOLDOWNS AND POST ANCHORS TO BE INSTALLED ACCORDING TO MOST CURRENT <br />SIMPSON STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICC-ER REPORTS & SHALL <br />BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. DIMENSIONS ARE NOT FURNISHED <br />TO SIMPSON HOLDOWNS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR'S <br />SUPERINTENDENT, THE FRAMING CONTRACTOR AND THE CONCRETE CONTRACTOR TO <br />LOCATE THESE ANCHORS IN THE EXACT LOCATION. REFER TO DETAILS FOR PROPER <br />INSTALLATION. <br />MIN. CONCRETE WIDTH TO BE 8" FOR RECEIVING PA, HPA & STHD'S. VERIFY LOCATIONS OF <br />HOLDOWNS AND ANCHOR BOLTS WITH ROUGH FRAMING TO ASSURE ACCURATE <br />INSTALLATION. <br />PROVIDE #3 X 24" DOWEL AT 24" O.C. AND 12" FROM THE CORNER AT ALL CONCRETE <br />STOOPS AND PORCHES. <br />PROVIDE MIN. (1) #4 REINFORCING FOR ELECTRICAL GROUND, LOCATION TO BE VERIFIED <br />WITH THE ELECTRICAL CONTRACTOR. <br />VERIFY MIN. FOUNDATION DEPTH, WIDTH, REINFORCING STEEL AND ADDITIONAL <br />EXPANSIVE SOIL REQUIREMENTS WITH VALID SOILS REPORT AND IF MORE STRINGENT, <br />THEY SHALL SUPERSEDE THE ABOVE MINIMUM REQUIREMENTS. SEE NOTE #8 UNDER <br />REINFORCED CONCRETE FOR CONCRETE STRENGTH. <br />PLACEMENT SHALL BE IN ONE CONTINUOUS OPERATION UNLESS OTHERWISE SPECIFIED. <br />SLAB SURFACE SHALL BE CURED WITH 'HUNTS' COMPOUND OR EQUAL OR CURED WITH <br />OTHER METHODS IN ACCORDANCE WITH GOOD CONSTRUCTION PRACTICE AT <br />CONTRACTOR'S OPTION. <br />CONTRACTOR SHALL DAMPEN SLAB UNDERLAYMENT OF SAND/MEMBRANE JUST PRIOR TO <br />CONCRETE PLACEMENT TO ASSIST UNIFORM CONCRETE CURING. SLABS MUST NOT BE <br />POURED DURING OR IMMEDIATELY AFTER RAINSTORMS. THE SPECIFIED SAND OVER <br />VISQUEEN SHOULD NOT BE SATURATED AT THE TIME OF THE CONCRETE POUR. ANY FREE <br />WATER TRAPPED IN THE SAND LAYER MUST BE REMOVED PRIOR TO THE CONCRETE POUR. <br />THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE LEVEL, CLEAN AND FREE OF LOOSE <br />MATERIAL OR WATER WHEN CONCRETE IS PLACED. OVER EXCAVATION SHALL BE FILLED <br />WITH CONCRETE OR PROPERLY COMPACTED FILL THAT HAS BEEN TESTED AND APPROVED <br />BY THE SOILS ENGINEER. BACKFILL SHALL NOT BE PLACED UNTIL SUPPORTING <br />FOUNDATIONS, WALLS AND SLAB HAVE ATTAINED SUFFICIENT STRENGTH TO SUPPORT <br />LATERAL SOIL PRESSURE. <br />CONCRETE PLACEMENT SHALL BE MONOLITHIC IN ONE CONTINUOUS OPERATION <br />UNIFORMLY PLACED AND MUST BE VIBRATED AND WELL CONSOLIDATED UNLESS SHOWN <br />OTHERWISE ON PLANS. DUAL POUR IS DEFINED BY ACI AS TO WHEN 1ST. & 2ND. POUR CAN <br />NOT BE VIBRATED TOGETHER. <br />FINISH GRADE AROUND THE PERIMETER OF SLAB SHALL BE CONSTRUCTED SUCH THAT <br />RAIN AND IRRIGATION WATER IS DRAINED AWAY FROM THE SLAB. <br />FOUNDATION DRAWINGS PREPARED BY E.O.R. REFLECT THE STRUCTURAL REQUIREMENTS. <br />REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS, DEPRESSIONS, SLOPE, SHELVES, <br />PATIOS, STOOPS AND PORCHES NOT SHOWN IN FOUNDATION DRAWINGS. ACCURACY OF THE <br />DIMENSIONS AND FINAL FIT OF THE BUILDING SHALL BE REVIEWED BY THE ARCHITECT <br />AND THE CONTRACTOR PRIOR TO CONSTRUCTION. <br />WAITING PERIOD FOR CONCRETE SLABS-ON-GRADE PRIOR TO START OF CONSTRUCTION IS <br />AS FOLLOWS: <br />NO PIPES OR CONDUITS SHALL EXTEND UNDER ISOLATED COLUMN FOOTING OR UNDER <br />CONTINUOUS WALL FOOTINGS UNLESS SPECIFICALLY DETAILED OR APPROVED BY THE <br />ARCHITECT, STRUCTURAL ENGINEER AND THE BUILDING OFFICIAL. <br />3a. <br />ALL CONTINUOUS FOOTINGS TO HAVE 5/8"DIA. X MIN. 12" ANCHOR BOLTS, MIN. 7" <br />EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. UNLESS NOTED OTHERWISE ON PLANS. <br />ONE ANCHOR BOLT SHOULD BE LOCATED MAX. 12" AWAY AND MIN. 9 3/8" FROM THE END <br />OF THE BOTTOM TRACK. MIN. (2) A.BS. PER BOTTOM TRACK/SHEAR PANEL. BOTTOM <br />TRACK UNDER SHEAR WALLS OF UP TO 8'-0" IN LENGTH MUST BE CONTINUOUS. SEE NOTE <br />2 FOR BOTTOM TRACK FASTENERS AT INTERIOR NON-SHEAR WALLS. <br />ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS OF <br />SIMPSON BP5/8-3 OR BPS5/8-3 BETWEEN TRACK AND NUT. ANCHOR BLOTS SHALL <br />HAVE A MINIMUM 1 3/4" EDGE DISTANCE FROM CONCRETE STEM WALL/FOUNDATION <br />FACE AS SHOWN BELOW. <br />TYPICAL BP INSTALLED WITH A BOTTOM TRACK ANCHOR BOLT <br />7" <br /> <br />M <br />I <br />N <br />I <br />M <br />U <br />M <br /> <br />E <br />M <br />B <br />E <br />D <br />M <br />E <br />N <br />T <br />SIMPSON BP/BPS <br />1 3/4" Min <br />FOOTINGS SHALL BEAR ON NATIVE SOIL <br />THE CBC CHAPTER 18 SHALL BE FOLLOWED AND SHALL BE CONSIDERED MINIMUM <br />REQUIREMENTS UNLESS MORE STRINGENT REQUIREMENTS ARE PRESENTED IN THE <br />SPECIFICATIONS OR ON THE DRAWINGS. <br />1. <br />2. <br />THE CONTRACTOR SHALL CONFORM TO ALL STATE AND LOCAL LAWS GOVERNING THE <br />WORK AND OBTAIN ALL NECESSARY LICENSES AND PERMITS. <br />1. <br />2.ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST <br />ARCHITECTURAL DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE OMITTED <br />OR NOT CLEAR, CONTACT THE ARCHITECT OR STRUCTURAL ENGINEER OF RECORD FOR <br />CLARIFICATIONS. <br />THE CONTRACTOR SHALL COMPARE THE STRUCTURAL DRAWINGS WITH ARCHITECTURAL, <br />PLUMPING, MECHANICAL, CIVIL AND ELECTRICAL DRAWINGS AS TO ALL LAYOUTS, <br />DIMENSIONS AND ELEVATIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE <br />ARCHITECT FOR PROPER ADJUSTMENT BEFORE PROCEEDING WITH THE WORK. <br />3. <br />SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL DRAWINGS <br />MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR GREATER CAPACITY AND <br />PERFORMANCE. CURRENT EVALUATION REPORTS AND PRODUCT INFORMATION SHALL BE <br />PROVIDED TO THE STRUCTURAL ENGINEER DEMONSTRATING THE REQUIRED CAPACITY <br />AND PERFORMANCE OF THE MATERIAL TO BE SUBSTITUTED. WRITTEN APPROVAL FROM <br />THE E.O.R SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF ANY MATERIAL <br />SPECIFIED ON THE STRUCTURAL CONSTRUCTION DOCUMENTS. <br />4. <br />ANY DEVIATION, MODIFICATION & SUBSTITUTION FROM THE APPROVED SET OF <br />STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR <br />REVIEW/APPROVAL PRIOR TO ITS USE OR INCLUSION ON THE SHOP DRAWINGS & PRIOR TO <br />PROCEEDING WITH THE WORK. <br />5. <br />EXISTING CONDITIONS AS SHOWN ON THESE PLANS ARE FOR REFERENCE ONLY. <br />CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO <br />CONSTRUCTION. CONTRACTOR SHALL REPORT CONDITIONS THAT CONFLICT WITH THE <br />CONTRACT DOCUMENTS TO THE OWNER'S REPRESENTATIVE. DO NOT DEVIATE FROM THE <br />CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE OWNER'S <br />REPRESENTATIVE. <br />6. <br />THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD <br />IMPOSED UPON THE STRUCTURE. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN <br />CAPACITY OF THE STRUCTURE AT THE TIME THE LOADS ARE IMPOSED. <br />7. <br />SPECIFICATIONS RELATED TO WATERPROOFING, INCLUDING BUT NOT LIMITED TO <br />MEMBRANES, WATERSTOPS, SEALANTS, FLASHING, VAPOR BARRIER, ARE AS SPECIFIED BY <br />ARCHITECT/WATER PROOFING CONSULTANT. <br />8. <br />FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL AND SHALL APPLY GENERALLY <br />THROUGHOUT SIMILAR CONDITIONS. ALL DETAILS REFERENCED, AND DETAILS NOT <br />REFERENCED ON PLANS, SHALL BE CONSIDERED TYPICAL AND APPLY TO ALL SIMILAR <br />CONDITIONS OF THE CONSTRUCTION. <br />9. <br />UNLESS SHOWN OTHERWISE, DETAILS SHOWN ON "TYPICAL DETAIL" SHEETS SHALL BE <br />USED WHEREVER APPLICABLE. SPECIFIC DETAILS ON THE STRUCTURAL DRAWINGS TAKE <br />PRECEDENCE OVER "TYPICAL DETAILS". SPECIFIC NOTES ON STRUCTURAL DRAWINGS <br />TAKE PRECEDENCE OVER NOTES SHOWN IN "GENERAL NOTES". <br />10. <br />THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED <br />STRUCTURE, UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF <br />CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO <br />PROTECT THE CONSTRUCTION AND ALL ADJACENT PROPERTIES DURING CONSTRUCTION. <br />SUCH MEASURES SHALL INCLUDE BUT ARE NOT LIMITED TO BRACING, SHORING OF LOADS <br />DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE <br />ARCHITECT OR E.O.R SHALL NOT INCLUDE OBSERVATION OF THE ABOVE ITEMS. <br />11. <br />GENERAL NOTES <br />CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST EDITION <br />OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION DOCUMENTS. <br />PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II, U.N.O. <br />THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), f'c: <br />a. ALL LOCATIONS, U.N.O: MIN 2500 PSI, (W/C = 0.45) SPECIAL INSPECTION IS REQUIRED <br />WHEN f'c > 2500 PSI. <br />b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.1% BY <br /> WEIGHT: 4000 PSI, SPECIAL INSPECTION IS NOT REQUIRED. <br />c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.2% BY <br /> WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. <br />1. <br />AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR LOW <br />SHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE FOR LIGHTWEIGHT <br />CONCRETE SHALL CONFORM TO ASTM C-330. <br />DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIXING <br />CONCRETE SHALL CONFORM WITH ASTM C1602. <br />CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT <br />VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY REPLACE UP <br />TO 20% PORTLAND CEMENT BY VOLUME. <br />CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND <br />SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. <br />ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS SHALL BE <br />WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />CONCRETE <br />TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE WITH <br />ASTM C94. <br />10.CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI 305R <br />AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. <br />11.CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF CURING <br />HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB CURING, <br />CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF CURING <br />COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY WORK. <br />MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADMIXTURES/PLACITIZERS HAVE BEEN <br />ADDED IN THE MIX DESIGN TO IMPROVE FLOWABILITY/WORKABILITY. THE SLUMP LIMIT <br />SHALL BE BASED ON ADMIXTURE MANUFACTURER'S RECOMMENDATIONS. <br />12. <br />FASTENING SCHEDULE :(AS PER AISI LATEST EDITION ) <br />CONNECTION NUMBER AND SIZE <br />OF FASTENERS <br />SPACING OF FASTENERS <br />FLOOR JOIST TO TRACK OF AN <br />INTERIOR LOAD BEARING WALL. <br />SUBFLOOR SHEATHING TO FLOOR JOIST <br />2-#10 SCREWS EACH JOIST <br />2-#10 SCREWS ONE PER FLANGE OR TWO <br />PER BEARING STIFFENER <br />#10 SCREWS2 <br />1 <br />6" ON CENTER ON EDGES <br />AND 10" ON CENTER AT <br />INTERMEDIATE SUPPORTS <br />STUD TO TOP OR BOTTOM TRACK 2-#10 SCREWS EACH END OF STUD, <br />ONE PER FLANGE <br />STRUCTURAL SHEATHING( ORIENTED <br />STRAND BOARD OR PLYWOOD) <br />TO FRAMING <br />6" ON EDGES & 12" ON <br /> INTERMEDIATE SUPPORTS#10 SCREWS2 <br />1/2" GYPSUM WALL BOARD TO FRAMING #10 SCREWS 12" O.C. <br />CEILING JOIST TO TOP TRACK OF LOAD <br />BEARING WALL.2-#10 SCREWS EACH JOIST <br />ROOF SHEATHING( ORIENTED STRAND <br />BOARD OR PLYWOOD) TO RAFTERS #10 SCREWS 6" ON CENTER ON EDGES <br />AND 12" ON CENTER AT <br />INTERIOR SUPPORTS <br />RAFTER/TRUSS TO BEARING WALL 2-#10 SCREWS EACH RAFTER/TRUSSES3 <br />GABLE END TRUSS/RAFTERS TO <br />ENDWALL TOP TRACK #10 SCREWS 12" O.C. <br />RAFTER TO CEILING JOIST OR <br />RIDGE MEMBER MIN. #10 SCREWS SEE NOTE NO.4 <br />NOTES: <br /> 1. SCREW SIZES SHOWN ARE MINIMUM. UNLESS OTHERWISE NOTED. <br /> 2. HEAD STYLE SHALL BE BUGLE-HEAD, FLAT HEAD OR SIMILAR HEAD WITH MINIMUM <br /> HEAD DIAMETER OF 0.29" <br /> 3. SCREWS SHALL BE APPLIED THROUGH THE FLANGE OF THE RAFTER/TRUSS OR CEILING <br /> JOIST OR A 16 GAUGE CLIP ANGLE SHALL BE USED WITH 2 #10 SCREWS IN EACH LEG. <br /> 4. NUMBER OF SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR RAFTER TO RIDGE <br /> MEMBER CONNECTION <br />(See Table footnotes in Next column) <br />FLOOR JOIST TO TRACK AT END OF <br />JOIST <br />COLD FORMED METAL FRAMING <br />10.PROVIDE MINIMUM YIELD STRESS, FY , OF 50 KSI FOR 16 GAUGE (54 MIL) AND THICKER AND <br />33 KSI FOR 18 GAUGE (43 MIL) AND THINNER. <br />11.COLD-FORMED STEEL JOISTS SHALL HAVE PUNCHED ENLARGED SERVICE HOLES WITH <br />STIFFENED FLANGES. <br />12.EXTERIOR WALL STUDS SHALL BE 600S162-43 (18 GAUGE) @24" O.C. AND SATISFYING THE <br />REQUIREMENTS OF LOAD BEARING STUD WALLS PER TABLE OF NOTE 13 BELOW <br />(WHICHEVER IS GREATER).UNLESS NOTED OTHERWISE ON PLANS. WALLS SHALL BE <br />PROVIDED WITH MANUFACTURER'S STANDARD BRIDGING ( EITHER WELDED 2 1/2"X18 GAUGE <br />STUD OR CLIPPED COLD-ROLLED CHANNEL 1 1/2"X16" GAUGE). PROVIDE BRIDGING AT 4'-0" <br />O.C. MAXIMUM FOR LOAD BEARING WALLS AND EXTERIOR WALLS. <br />13. <br />EXCEPTION: WHERE FULL HEIGHT SHEATHING OR GYP BOARD OCCURS ON BOTH SIDE OF <br />WALL STUDS, BRIDGING IS ALLOWED TO BE OMITTED <br />14.ALL KNEE WALL STUDS OVER THE FOOTING STEMS SHALL BE 600S162-54 <br />(16 GAUGE) @ 24" O.C. UON. <br />1.ALL COLD-FORMED METAL FRAMING SHALL CONFIRM TO AISI STANDARD S100-16 "NORTH <br />AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL <br />MEMBERS''. <br />2.SHALL MEET ALL THE REQUIREMENT AISI 2022 LATEST EDITION. <br />3.CONTRACTOR SHALL PROVIDE EFFECTIVE, FULL TIME QUALITY CONTROL OVER ALL <br />FABRICATION AND ERECTION COMPLYING WITH THE PERTINENT CODES AND REGULATIONS <br />OF GOVERMENT AGENCIES HAVING JURISDICTION. <br />4.PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT LIMITED TO, TRACKS, CLIPS WEB <br />STIFFENERS, ANCHORS, FASTENING DEVICES, RESILIENT CLIPS, AND OTHER ACCESSORIES <br />REQUIRED FOR A COMPLETE AND PROPER INSTALLATION, AND AS RECOMMENDED BY THE <br />MANUFACTURER FOR THE STEEL MEMBERS USED. <br />5.FASTENING OF COMPONENTS SHALL BE WITH ICC APPROVED SELF-DRILLING SCREWS OR <br />WELDING, SCREWS OR WELDS SHALL BE OF SUFFICIENT SIZE TO INSURE THE STRENGTH <br />OF THE CONNECTION ALL WELDS OF GALVANIZED STEEL SHALL BE TOUCHED UP WITH A <br />ZIN-RICH PAINT. ALL WELDS OF CARBON SHEET STEEL SHALL BE TOUCHED UP WITH <br />PAINT. WIRE TYING OF COMPONENTS SHALL NOT BE PERMITTED. <br />6.UNIFORM AND LEVEL JOIST BEARING SHALL BE PROVIDES AT FOUNDATION WALLS BY <br />MEANS OF SHIMS AND/OR NON-SETTING GROUT. <br />7.ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO AISI "SPECIFICATION FOR THE <br />DESIGN OF COLD FORMED STEEL'', LATEST EDITION. <br />8.ALL WELDING SHALL BE DONE BY CERTIFIED WELDERS IN FULL COMPLIANCE WITH AWS D1.3 <br />9.UNLESS NOTED OTHERWISE ON THE DRAWINGS, SCREWS SHALL BE #10-16 SELF DRILLING, <br />SELF TAPPING HEX HEAD SCREWS WITH HEAD DIAMETER OF 0.333 IN. <br />ALL WALL STUD FRAMING SHALL SATISFY THE REQUIREMENTS OF TABLE BELOW. PROVIDE <br />BRIDGING AT 4'-0" O.C. MAXIMUM FOR LOAD BEARING WALLS. WHERE FULL HEIGHT <br />SHEATHING OR GYP BOARD OCCURS ON BOTH SIDE OF WALL STUDS, BRIDGING IS ALLOWED <br />TO BE OMITTED. <br />STUD SIZE <br />MAXIMUM SPACING WHEN SUPPORTING <br />ONE FLOOR <br />ROOF & <br />CL'G <br />TWO FLOOR <br />ROOF & <br />CL'G <br />STUD <br />HEIGHT <br />BEARING WALLS <br />(inches) <br />600S162-54 <br />24 <br />600S162-43 <br />362S162-43 24 <br />24 -- <br />(feet) <br />9 <br />NON-BEARING WALLS <br />STUD <br />HEIGHT <br />(inches) <br />24 <br />(feet) <br />16'-0" <br />9 <br />9 24 24 24 <br />MAXIMUM SPACING <br />(inches) (inches) <br />ROOF & <br />CL'G ONLY <br />24 <br />-- <br />2424'-0" <br />2426'-0" <br />362S162-54 24 249 2416'-0"24 <br />1. <br />DESIGN CRITERIA <br />SOILS <br />3. <br />LATERAL LOADS:2. <br />TOTAL = 40 PSF <br />LIVE LOAD = 20 PSF <br />DEAD LOAD = 20 PSF <br />ROOF LOAD <br />DESIGN LOADS: <br />C <br />110WIND SPEED: <br />WIND EXPOSURE: <br />SITE CLASS = <br />RISK CATEGORY:II <br />D-DEFAULT <br />1.307 <br />0.466 <br />1.046 <br />0.570 <br />SEISMIC DESIGN CATEGORY: D <br />SEISMIC IMPORTANCE FACTOR (I) = 1.0 <br />0.11 <br />6 <br />TOTAL DESIGN BASE SHEAR: <br />BASIC SEISMIC FORCE RESISTING SYSTEM: <br />ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE <br />0.11W 0.11W <br />PLYWOOD SHEAR WALLS <br />0.11 <br />6S1 :SD1 : <br />SDS :SS : <br />RY : <br />0.7XCSY : <br />RX : <br />0.7XCSX : <br />; VX =VY = <br />SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF <br />SHEET INDEX <br />- GENERAL NOTES & REQUIREMENTS.SN-1 <br />- FRAMING PLANS-1.0 <br />REVISIONS <br />AS INDICATED <br />12/16/2025 <br />2567 <br />NA <br />JOB NO.: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />L <br />O <br />C <br />A <br />T <br />I <br />O <br />N <br />SCALE: <br />DATE: <br />DESIGNER: <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />T <br />I <br />T <br />L <br />E <br />Owner: <br />LJN ENGINEERING <br />THIS DRAWING AND DESIGN CONCEPTS <br />ARE PROPRIETARY TO LJN ENGINEERING. <br />THE DRAWING OR DESIGN CONCEPTS <br />SHALL NOT BE USED OR REPRODUCED IN <br />THE PART OR IN WHOLE WITHOUT THE <br />WRITTEN PERMISSION BY LJN <br />ENGINEERING. <br />Phone: <br />Email: <br />DESCRIPTIONDATENO. <br />SHEET NAME: <br />SHEET NUMBER: <br />WA <br />T <br />E <br />R <br /> <br />S <br />T <br />O <br />R <br />E <br />16 <br />4 <br />1 <br /> <br />E <br />, <br /> <br />1 <br />7 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br /> <br /># <br />A <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />*CIVIL ENGINEERING, STRUCTURAL SERVICES <br />*RESIDENTIAL - COMMERCIAL - INDUSTRIAL <br />* QUALITY - SAVING TIME - SAVING BUDGET <br />Add : 7138 TIARA AVE, HIGHLAND, CA 92346 <br />Tel : (840) 266 - 5063 <br />Email : ljnengineering2022@gmail.com <br />SN-1 <br /> <br /> <br /> <br /> <br />GENERAL DETAILS <br />& NOTES